SkyCiv Documentation

Your guide to SkyCiv software - tutorials, how-to guides and technical articles

SkyCiv Member Design

  1. Home
  2. SkyCiv Member Design
  3. Code Verification
  4. AS 4100 Code Verification

AS 4100 Code Verification

AS 4100-1998 Design Code Verification

AISC 360-10 manual

Information presented on this page is intended to demonstrate the section design convergence that can be achived with SkyCiv. All examples are taken from the Steel Structures Design Manual To AS 4100 (authors Brian Kirke, Iyad Hassan Al-Jamel). Current manual consists description of algorithm of manual calculations.

Example 6.4.3: Sizing an Intermediate Column in a Multistory Building (members subject to axial compression)

Design Case Manual SkyCiv
Nominal section capacity Φs, kN 4410.00 4410.00
Nominal member capacity Φc, kN 3706.61 3704.84

 

Example 7.3.6: Checking a Simply Supported Beam with Overhang (members subject to bending)

Design Case Manual SkyCiv
Nominal section moment capacity Φsz, kN-m: Segment (A-B) & Segment (D-E) 309.96 309.96
Nominal member moment capacity Φb, kN-m: Segment (A-B) & Segment (D-E) 248.46 246.90
Nominal section moment capacity Φsz, kN-m: Segment (A-B) & Segment (B-D) 309.96 309.96
Nominal member moment capacity Φb, kN-m: Segment (A-B) & Segment (B-D) 265.96 263.42

 

Example 7.3.11: Steel Beam Complete Design Check (members subject to bending)

Design Case Manual SkyCiv
Nominal section moment capacity Φsz, kN-m 242.2 241.65
Nominal shear capacity of the web Φvy, kN 449.0 447.95

 

Example 8.3.2: Biaxial Bending Member Capacity

Design Case Manual SkyCiv
Nominal section moment capacity Φsx, kN-m 639.90 639.90
Nominal section moment capacity Φsy, kN-m 92.34 92.49
Nominal member moment capacity Φbx, kN-m 244.50 241.81
Nominal shear capacity of the web Φvy, kN 939.40 939.62
Biaxial bending member capacity 0.98 0.98