The development length of reinforcement is a critical parameter in structural concrete design, ensuring that reinforcing bars can adequately transfer stresses between the concrete and steel. セクション 25.4 ACIの 318 provides the requirements and methodologies for calculating development length to achieve proper anchorage of reinforcement. This ensures structural integrity, 安全性, and serviceability under various loading conditions. The development length is influenced by bar size, コンクリートの強度, bond conditions, カバー, 間隔, and whether the bar is in tension or compression. The provision covers basic development lengths for straight bars, adjustments for epoxy coatings, confinement effects, and conditions where bars are hooked or bundled.

The latest SkyCiv Foundation Design update supports standard hooked reinforcements, enabling precise development length checks. Users can now customize footing bar ends as straight bars, 90° hooks, or 180° hooks, ensuring flexibility for various design needs. This guide outlines the step-by-step process for determining the required development length for pad footings following ACI 318 セクション 25.4, considering relevant modification factors to comply with code requirements.

SkyCivのFoundationDesignソフトウェアを試してみたい? 当社の無料ツールを使用すると、ユーザーは次のことを実行できます。 コンクリート基礎の計算 何もダウンロードしたりインストールしたりせずに!

 

Dowel Bar Development Length Check

Dowel bars in pad footings ensure a strong connection between the footing and columns, effectively transferring loads and maintaining structural integrity. Factors such as bar diameter, 鋼種, and concrete strength determine the required embedment. Ensure the embedment meets or exceeds the calculated length for safe load transfer and anchorage. 通常, column pedestals are subjected to compression loads, and the required development length is calculated using the provisions under Sectio 25.4.9 (Development of deformed bars in compression).

 

セクション 25.4.9.2: Compression development length (lDC)

メトリック:

\(l_{DC} = MAX \left[ \フラク{0.24 f_{そして} \psi_{r}}{\lambda \sqrt{f’_{c}}} \SkyCiv Foundationには、オーストラリア規格に準拠した孤立した基礎の設計が含まれています¹{b}, 0.042 f_{そして} \psi_{r} d_{b}, 200mm \right]\) Eq.1
インペリアル:

\(l_{DC} = MAX \left[ \フラク{f_{そして} \psi_{r}}{50 \ラムダ sqrt{f’_{c}}} \SkyCiv Foundationには、オーストラリア規格に準拠した孤立した基礎の設計が含まれています¹{b}, 0.0003 f_{そして} \psi_{r} d_{b}, 8inch \right]\) Eq. 2
どこ:

fそして = Rebar yield strength (MPa, psi)
f’c = Concrete strength (MPa, psi)
db = Dowel bar diameter (んん, に)

テーブル 25.4.9.3: Modification factors for deformed bars or wires in compression

 

The SkyCiv Foundation Design module checks each load combination to determine if the column is subjected to tensile forces. もしそうなら, the required development length is calculated following Section 25.4.2 (Development of bars or wires in tension). A brief explanation of this calculation is provided later in the guide.

Required footing thickness (hreq’d)

The thickness of the footing should be greater than or equal to the calculated required embedment of the dowel bars. The minimum footing thickness is checked by using Equations 3 そして 4.

Minimum Footing Thickness

\(h_{req’d} = cover + d_{b,バツ} + d_{b,と} + d_{b, dowel} + r + l_{d} \) (Eq. 3)

\(h_{req’d} \leq t\) (Eq. 4)

どこ:

t = Footing Thickness (んん, に)
cover = Bottom concrete cover (んん, に)
db,バツ, db,と = Footing bar size in the x and z directions (んん, に)
db,dowel = Dowel bar size (んん, に)
ld = Development length required in compression or tension (んん, に)
r = Minimum bend radius (んん, に)

 

Development Length Check For Footing Reinforcements

The SkyCiv Foundation Design module allows users to specify bar end configurations as straight or hooked bars (90° or 180°).

 

Calculating the required development length for footing reinforcements directly influences the footing’s dimensions, ensuring they are adequate to anchor the reinforcement against tensile forces. セクション 25.4.2 provides a guide on determining the required development length of the footing reinforcements.

Straight bars (セクション 25.4.2.3)

メトリック:

\(l_{d} = MAX \left[ \左( \フラク{f_{そして}}{1.1 \ラムダ sqrt{f’_{c}}} \[object Window]{\psi_{!} \psi_{2} \psi_3}{\左(c_{b} + K_{tr} \正しい) / d_{b}} \正しい)\SkyCiv Foundationには、オーストラリア規格に準拠した孤立した基礎の設計が含まれています¹{b}, 300mm \right]\) (Eq. 5)
インペリアル:

\(l_{d} = MAX \left[ \左( \フラク{3 f_{そして}}{40\ラムダ sqrt{f’_{c}}} \[object Window]{\psi_{!} \psi_{2} \psi_3}{\左(c_{b} + K_{tr} \正しい) / d_{b}} \正しい) \SkyCiv Foundationには、オーストラリア規格に準拠した孤立した基礎の設計が含まれています¹{b}, 12in\right]\) (Eq. 6)

どこ:

テーブル 25.4.2.4: Modification factors for the development of deformed bars and wires in tension

cb = Minimum bar clear distance (んん, に)
Ktr = Transverse reinforcement index (んん, に)
(cb + Ktr) / db ≤ 2.5

Standard hooked bars (セクション 25.4.3.1)

メトリック:

\(l_{d} = MAX \left[ \左( \フラク{0.24 f_{そして} \psi_{e} \psi_{c} \psi_{r}}{\ラムダ sqrt{f’_{c}}} \正しい)\SkyCiv Foundationには、オーストラリア規格に準拠した孤立した基礎の設計が含まれています¹{b}, 8d_{b}, 150 mm \right]\) (Eq. 7)
インペリアル:

\(l_{d} = MAX \left[ \左( \フラク{f_{そして} \psi_{e} \psi_{c} \psi_{r}}{50 \ラムダ sqrt{f’_{c}}} \正しい)\SkyCiv Foundationには、オーストラリア規格に準拠した孤立した基礎の設計が含まれています¹{b}, 8d_{b}, 6 right で]\) (Eq. 8)

どこ:

テーブル 25.4.3.2: Modification factors for the development of hooked bars in tension

 

Minimum Extension Length (7.7.3.3)

Reinforcement shall extend beyond the point at which it is no longer required to resist flexure for a distance at least the greater of d and 12db.

\(l_{ext,分} = MAX \left[d, 12d_{b}\正しい]\) (Eq. 9)

どこ:

d = Effective depth (んん, に)
db = Bar size (んん, に)

 

Anchorage Length Provided

The SkyCiv Foundation Design module assesses the anchorage length on both the left and right sides of each column face. Each anchorage length must meet or exceed the greater of the required development length or the minimum extension length.

\(l_{提供された} \geq MAX \left( l_{d,req’d}, l_{ext, 分} \正しい)\) (Eq. 10)

 

ディテールチェック: Verification of Footing Thickness (t):

The SkyCiv Foundation Design module checks whether the footing thickness is adequate based on bar configuration and concrete cover. If it is insufficient or the bars protrude, it issues a warning instead of a design failure. The module evaluates the footing thickness at each end of the longitudinal and transverse reinforcements in both the top and bottom layers.

\(\左(\テキスト{h + カバー}\正しい) \leq t\) (Eq. 11)

 