The development length of reinforcement is a critical parameter in structural concrete design, ensuring that reinforcing bars can adequately transfer stresses between the concrete and steel. Ενότητα 8.4 ή ΚΑΙ 1992-1-1 provides the method for calculating development length to achieve proper anchorage of reinforcement. This ensures structural integrity, ασφάλεια, and serviceability under various loading conditions. The development length is influenced by bar size, αντοχή σκυροδέματος, bond conditions, κάλυμμα, απόσταση, and whether the bar is in tension or compression.
The latest SkyCiv Foundation Design update supports standard hooked reinforcements, enabling precise development length checks. Users can now customize footing bar ends as straight bars, 90° hooks, or 180° hooks, ensuring flexibility for various design needs. This guide outlines the step-by-step process for determining the required anchorage length for pad footings following EN 1992-1-1 Ενότητα 8.4, considering relevant influencing factors to comply with code requirements.
Column Anchorage Length Check
Dowel bars in pad footings ensure a strong connection between the footing and columns, effectively transferring loads and maintaining structural integrity. Τυπικά, column pedestals are subjected to compression loads, and the required development length is calculated using the provisions under Section 8.4.
Ενότητα 8.4.3: Basic anchorage length (μεγάλοσι,rqd)
Ενότητα 8.4.4: Design anchorage length (μεγάλοbd)
φάbd = Ultimate bond stress (MPa)
σsd = Design stress of the bar at the position from where the anchorage is measured from (MPa)
ρεσι = Dowel bar diameter (χιλ)
Available depth (μεγάλο)
The available depth should be greater than or equal to the calculated required embedment of the dowel bars. This depth is checked using Equations 2, then compared to the computed development length for the utility ratio.
\(l = t – (κάλυμμα + ρε_{σι,Χ} + ρε_{σι,με}) \) (Εξ. 3)
Οπου:
t = Footing Thickness (χιλ)
cover = Bottom concrete cover (χιλ)
ρεσι,Χ, ρεσι,με = Footing bar size in the x and z directions (χιλ)
Anchorage Length Check For Footing Reinforcements
The SkyCiv Foundation Design module allows users to specify bar end configurations as straight or hooked bars (90° or 180°).
Calculating the required development length for footing reinforcements directly influences the footing’s dimensions, ensuring they are adequate to anchor the reinforcement against tensile forces. Ενότητα 9.8.2.2 provides a guide on determining this tensile force which is then used in the calculation of anchorage length.
Similar to what was presented in Equations 1 και 2, the tension anchorage length check uses the same formula but with varying influencing factors.
Available Anchorage Length
\(μεγάλο_{σι} = x – κάλυμμα \) (Εξ. 4)
\(μεγάλο_{σι} \geq l_{bd}\) (Εξ. 5)
Θέλετε να δοκιμάσετε το λογισμικό Foundation Design του SkyCiv? Το δωρεάν εργαλείο μας επιτρέπει στους χρήστες να αποδίδουν συγκεκριμένοι υπολογισμοί βάσης χωρίς να κατεβάσετε ή να εγκαταστήσετε τίποτα!
Προγραμματιστής προϊόντος
BSc, ΜΕΝ (Εμφύλιος)