以下是错误代码及其可能原因的列表. 当用户尝试解决无法解决的结构时,这些错误将显示在我们的 FEA 软件中. 下表显示了此类问题的可能原因和解决方案:
错误代码 | 信息 | 可能的问题 | 可能的解决方案 |
---|---|---|---|
1 | 时间到 – 服务器无法使用. |
|
|
2 | 时间到 – 解决方案花了太长时间. |
|
|
3 | 服务器错误 |
|
|
101 | 越权存取 |
|
|
102 | 请添加会员 |
|
|
103 | 请添加负载 |
|
|
104 | 请添加支持 |
|
|
105 | 请添加一个部分 |
|
|
106 – 109, 116, 117 | (*属性名称*) 的部分 ## 不能为零 |
|
|
110 | 结构不受限制 |
|
|
111 | 请删除断开连接的节点 # X |
|
|
112 | 请删除断开连接的元素 (会员) # X |
|
|
113 | 结构不受限制 |
|
|
114, 115, 118 | 解决错误 |
|
|
119 | 桁架结构不稳定 (仅SkyCiv桁架) |
|
|
181 | Member ID cannot be used for a support since it is the slave node (节点B) of the rigid link. |
|
|
182 | Node #ID is the master node (节点A) of Member #ID rigid link and cannot be used as the slave node (节点B) of another rigid link member. |
|
|
183 | Node #ID is the slave node of Member #ID but it is already used as a slave in another rigid link member. A slave node cannot be constrained to more than one master node. |
|
|
300, 301 | 非线性静态分析无法收敛 |
|
|
302 | 屈曲分析无法运行 |
|
|
303 | 动态频率分析无法运行 |
|
|
304, 305 | 响应谱分析未能运行 |
|
List of Warnings
Below are a list of warning messages that may not cause the solver to error, but could be adjustments or comments from the solving process:
信息 | 细节 |
---|---|
Continuous Member x has a problem with straightness as its internal members are using different local axes. Please check the nodes along this member form a straight line |
|
Load Combo y: 会员(s) x were removed from the model during the tension/compression only analysis over 1 迭代. | This is a warning regarding the iterative analysis when the model contains tension or compression members. The iterative analysis will remove compression members that are in tension (反之亦然). It will resolve, however in each iteration it checks if removed tension-members may have possibly reversed back to tension and compression-members have reversed back to compression. If the member gets removed and re-added from the model too many times (即. it reversed too much) then it just gets permanently removed as it’s deemed problematic for the iterative analysis to complete. |
Node x has been removed from the model because it is not used in any members or plates. | Solver detected an unused node and removed it during the analysis process |
Support #x for Node #y was ignored because the node was unused or does not exist. | Solver detected an unused support and removed it during the analysis process |
Load Combo #x: 1 iterations and y% convergence error | During a non-linear analysis the results will try to converge to a certain percentage (this can be adjusted in the software settings). This message is just notifying the user of that convergence error. |