La Fondation SkyCiv conçoit des semelles isolées, also called pad or spread footings, with a Finite Element Analysis (FEA) of the footing slab, soil pressure and Wood-Armer moment contours, diagrammes de cisaillement et de moment, and design checks to ACI 318, AS 3600, Eurocode 2 et CSA A23.3. This page gives an overview of these features.
Un isolé, ou semelle à un seul poteau, est utilisé pour supporter la charge d'une seule colonne. Ce sont les semelles les plus courantes, en particulier lorsque les charges sont relativement faibles et les colonnes ne sont pas étroitement espacées¹.

Figure 1. Semelle isolée
Isolated Footing Design Features
SkyCiv Foundation has the following features when designing isolated footings:
- Intuitive user interface with easy input, and a 3D view of the model and results
- Soil pressure analysis based on Finite Element Analysis (FEA), including bi-axial eccentricity
- Wood-Armer moments from the FEA results, for the top and bottom reinforcement in both directions
- Diagrammes de cisaillement et de moment, with plan views of the one-way shear critical sections and the punching shear critical perimeter
- Summary table of design check values and utility ratios
- Détaillé, rapport de calcul étape par étape (Téléchargement PDF ou HTML), including the FEA contours, the shear and moment diagrams and the critical section figures
It supports the following capabilities:
- Contrôles de conception selon ACI 318-14, ACI 318-19, AS 3600-2009, AS 3600-2018, EN 1992 (Eurocode 2) and CSA A23.3-14
- Eccentric footing design, with the column offset from the footing center in both plan directions
- Overturning moment and sliding factor of safety calculations
- Multiple load cases such as Dead, Habitent, Earthquake and Wind, combined into service (SLS) and ultimate (ULS) combinaisons de charges
- Personnalisation des charges, les matériaux, critères de renforcement et de conception, including factors of safety
For a tab-by-tab guide to the interface, voir le isolated footing User Manual.
Finite Element Analysis of the Footing
SkyCiv Foundation models the footing as a meshed plate on the soil and solves it with FEA. The soil pressure under the footing and the bending moments in the slab come from this analysis, which accounts for the column position, the load eccentricity and the parts of the footing that lift off the soil.
Maillage
The mesh is set under Maillage dans le Géométrie languette:
- Mesh Size: the size of the plate elements. A smaller mesh gives more detailed contours and results, at the cost of a longer solve time (paid feature).
- Show Mesh Preview: shows the mesh on the footing before you run the design. Allumer Mesh ID Label to show the number of each element. Hide Mesh Model returns to the 3D model.
Soil Pressure and Wood-Armer Contours
After running the design, l' Résultats tab shows the FEA results as contours on the footing. Use the buttons on the right of the 3D view to switch between them:
- Pression du sol: the bearing pressure under the footing. It shows how the pressure varies across the footing under eccentric loads and bi-axial moments, and where the footing lifts off.
- Armeur de bois: the Wood-Armer moments used to design the reinforcement. They combine the bending and twisting moments of the slab into the design moment for each layer and direction.
Le View Options panel sets what the contours show:
- Cas: Un service (SLS) ou Utilisez l'outil stylo pour ajouter rapidement des nœuds et des membres (ULS) combinaisons de charges.
- Combinaison de charge: a single load combination, or the envelope (Enveloppe Absolute Max, Enveloppe Max ou Enveloppe Min). The info button next to it lists the load combinations.
- Couche: Haut, Bas ou Les deux reinforcement layers (Wood-Armer moments only).
- Direction: Le long de X ou Along Z (Wood-Armer moments only).
To learn how eccentric loads change the pressure under a footing, voir pressure distribution under a rectangular footing.
Shear and Moment Diagrams
Le Diagrammes button on the right of the 3D view opens the shear and moment diagrams of the footing, built from the FEA results (paid feature). Pick what to show at the top of the window:
- Cas: service or ultimate load combinations.
- Diagramme:
- Cisaillement unidirectionnel: the shear diagram along the footing, next to a plan view of the one-way shear critical sections.
- Poinçonnage Cisaillement: a plan view of the punching shear critical perimeter around the column, with its dimensions.
- Moment: the moment diagram along the footing.
- Combinaison de charge, Couche (Top or Bottom) et Direction (Along X or Along Z), where they apply to the selected diagram.
The diagrams and the critical section figures are also included in the calculation report, next to the one-way shear, punching shear and flexure checks.
Design Settings for FEA Results
Modifier les paramètres de conception, dans le Détails languette, controls how the FEA results are used in the design checks (paid feature). The settings shown depend on the design code.
- Inclure le poids du sol et de la semelle: inclut le poids propre de la semelle et du sol au-dessus dans le SLS et ULS combinaisons de charges, and in the stability (STA) combinations for AS 3600. It can help counteract uplift.
- Punching Shear Demand Calculation: how the soil pressure force on the critical shear area is calculated. Mesh-based Method sums the force on each mesh element within the area, from the average soil pressure of each element. Corner-based Method uses the average soil pressure at the four corners of the area.
- Méthode de calcul du cisaillement au poinçonnement β (Eurocode): Simplifié, the recommended β values of EN 1992-1-1 Figure 6.21N, ou Répartition du cisaillement entièrement plastique.
- Calcul de la demande de moment: Méthode Peak Wood-Armer uses the maximum Wood-Armer moment for a conservative design. Méthode de moyenne par bande divides the footing into strips and calculates the moment as if each strip acts as a beam in its direction. This setting is not available for ACI 318-14.
- Use rule of two-thirds for bending moments (CSA A23.3, strip average method only).
The design settings also turn the one-way shear, load transfer and development length checks on or off.
Learn More About Footings
Pour en savoir plus sur les semelles, check out these articles:
- Qu'est-ce qu'une fondation
- Types de fondation et leurs utilisations
- Quel est le processus de conception d'une semelle de fondation?
Références:
- McCormac, Jack C., et Russell H. Brown. Conception du béton armé ACI 318-11 Édition de code. Wiley, 2014.