Steel Frame: Aperçu
The purpose of this test case is to validate some of the unit conversion for imperial units. Dans cet exemple, the following units were changed:
- Moment (kip-ft to lb-in)
- Obliger (kip to lb)
- Pression (ksi to psi)
The results are compared internally due to the concern of the verification only limited in the unit conversion of results and not necessarily the analysis.
Configuration du modèle
The structure is a 123-node, 276-structure de cadre de membre soutenu par des supports fixes. The building consists of general section beams made from steel.
Points d'évaluation: 10
Type de résolution: Analyse linéaire

Les résultats d'analyse
Résultat | Emplacement | SkyCiv Default | SkyCiv Converted Units | Conversion Equivalent |
---|---|---|---|---|
Moment Z | Membre 183, Nœud de démarrage | 11.531 kip-ft | 138368.621 lb-in | 11.531 kip-ft |
Moment Y | Membre 62, Nœud de fin | -0.044 kip-ft | -522.878 lb-in | -0.044 kip-ft |
Cisaillement Y | Membre 58, Nœud de fin | -0.450 kip | -449.583 le programme attribue des températures | -0.450 kip |
Cisaillement Z | Membre 101, Nœud de fin | -0.226 kip | -225.988 le programme attribue des températures | -0.226 kip |
Réaction Y | Nœud 93 | 4.597 kip | 4597.272 le programme attribue des températures | 4.597 kip |
Réaction Y | Nœud 64 | 2.638 kip | 2638.141 le programme attribue des températures | 2.638 kip |
Axial | Membre 110 | 0.215 kip | 214.907 le programme attribue des températures | 0.215 kip |
Axial | Membre 168 | 5.409 kip | 5408.611 le programme attribue des températures | 5.409 kip |
Contrainte de flexion supérieure Z | Membre 207, Nœud de démarrage | 327.075 KSI | 327074.571 psi | 327.075 KSI |
Contrainte de flexion supérieure Y | Membre 252, Nœud de fin | 2073.306 KSI | 2073305.516 psi | 2073.306 KSI |