Documentação SkyCiv

Seu guia para o software SkyCiv - tutoriais, guias de instruções e artigos técnicos

SkyCiv Member Design

  1. Casa
  2. SkyCiv Member Design
  3. Verificação de Código
  4. Verificação de código CSA S16

Verificação de código CSA S16

CSA S16-14 Design Code Verification

CSA S16-14 Manual

Verificação do Designer de Seção Geral SkyCiv para Seções RC. All examples are taken from:

  1. Limit States Design in Structural (authors G.L. Kulak, G.Y. Grondin)
  2. Handbook of Steel Construction CISC

Exemplo 4.1 página 80 (1). Determine the factored compressive resistance.

Caso de Design Manual SkyCiv
Factored compressive resistance Cr, kN 2880.00 2878.03

 

Exemplo 4.2 página 81 (1). Determine the factored compressive resistance.

Caso de Design Manual SkyCiv
Factored compressive resistance Cr, kN 529.00 526.36

 

Exemplo 4.6 página 87 (1). Determine the factored compressive resistance.

Caso de Design Manual SkyCiv
Factored compressive resistance Cr, kN 15700.00 15664.05

 

Exemplo 5.5 página 126 (1). Determine the factored moment resistance.

Caso de Design Manual SkyCiv
Factored moment resistance Mrz, kN-m 100.00 100.23

 

Exemplo 5.6 página 127 (1). Determine the factored moment resistance.

Caso de Design Manual SkyCiv
Factored moment resistance Mrz, kN-m 297.00 296.51

 

Exemplo 5.7 página 130 (1). Determine the factored moment resistance.

Caso de Design Manual SkyCiv
Factored moment resistance Mrz, kN-m 649.00 648.90

 

Exemplo 8.7 página 253 (1). Design of Members for Combined Forces.

Caso de Design Manual SkyCiv
Nominal section moment capacity Cr, kN 2200.00 2217.12
Nominal section moment capacity Mrz, kN-m 310.00 310.28
Interaction ratio of combined axial compression and bending resistance 0.930 0.926

 

Example page 4-115 (2). Design of Members for Combined Forces

Caso de Design Manual SkyCiv
Nominal section moment capacity Cr, kN 4240.00 4241.90
Nominal section moment capacity Mrz, kN-m 671.00 670.68
Nominal section moment capacity Mry, kN-m 308.00 307.71
Interaction ratio of combined axial compression and bending resistance 0.990 1.030
Este artigo foi útil para você?
sim Não

Como podemos ajudar?

Vá para o topo