Figura 1: Livro 1 (
Information presented on this page is intended to demonstrate the section design convergence of ACI 318-2014 provisions for isolated foundations that can be achieved with SkyCiv. All examples are taken from the following references:
Livro 1: David A. Fanella. Reinforced Concrete Structures Analysis and Design, 2011.
Exemplo # 1 Design of axially loaded Combined footing.
referência: Livro 1, pp.568.
DESCRIÇÃO
A Combined foundation is subjected to two (2) casos de carga estática (Morto e vivo). O cisalhamento resultante , momento, a transferência de carga e o comprimento de desenvolvimento são comparados com cálculos manuais. O modelo de fundação encontra-se no plano X-Z.
GEOMETRY AND MATERIAL PROPERTIES
Figura 2: Footing model and material properties of example #1
CARREGANDO
Three static loads cases are considered:
For Column 1
\( \texto{DL} = 300.00 \texto{ kips} \)
\( \texto{LL} = 115.00 \texto{ kips} \)
For Column 2
\( \texto{DL} =500.00 \text{ kips} \)
\( \texto{LL} = 225.00 \texto{ kips} \)
Os resultados da combinação de serviço e carga fatorial são calculados em referência ao ASCE / SEI 7-10.
ANÁLISE
The analysis is done using the rigid conventional method. See the Combined Footing User Manual for more explanation on using SkyCiv Foundation.
COMPARAÇÃO DE RESULTADOS
Shear and moment values and graph are compared in the figure below:
Figura 3: (1) Shear and Moment Diagram from skyCiv. (2) Taken in Figure 10.29 in Book 1 referência.
Os resultados mais significativos são comparados na tabela abaixo:
Resultados | ||
---|---|---|
Parâmetro | Manual | SkyCiv |
One way shear | ||
Actual Shear at critical | 437.167* | 438.41 |
ΦVc | 445* | 440.89 |
Albert Pamonag
Engenheiro estrutural, Desenvolvimento de Produto
B.S. Engenharia Civil