Documentación SkyCiv

Su guía para el software SkyCiv: tutoriales, guías prácticas y artículos técnicos

Beam, Diseño de columna – Ser único

Standalone Reinforced Concrete Beam and Column Design (AS 3600, EN 2, ACI 318)

This page explains how to design reinforced concrete beams and columns with the standalone version of SkyCiv RC Design, where you enter the design forces manually. It walks through each tab of the module (Detalles, Factores y configuraciones, Miembros, Diseños RC, Efectivo, Combinations and Results) para AS 3600, Eurocódigo 2 (EN 2) y ACI 318. To design the members of a SkyCiv Structural 3D model instead, ver beam and column design in Structural 3D.

Detalles

After you choose a design code, the module opens on the Detalles lengüeta, mostrada a continuación. The units are set automatically from the design code: metric for AS 3600 y EN 2, imperial for ACI 318.

Details tab of the standalone SkyCiv RC Design module with the project information fields

On this tab, you can enter the project details:

  • Nombre del proyecto
  • Projecto ID
  • Company name
  • en Hormigón
  • Cliente
  • Any other notes you want to include

This information appears in the design report.

Factores y configuraciones

Analysis Settings

Analysis Settings with the number of iterations and interaction curve points

En Analysis Settings, you set the number of iterations the program uses to find the depth of the compression zone of the section. This depth is then used to calculate the ultimate flexural capacity of the section. The procedure is:

  1. Suponga la profundidad del eje neutro, x (valor inicial d, the effective depth).
  2. Calculate the concrete compression force and the steel tension and compression forces.
  3. Check the equilibrium of the force components.
  4. Repeat until the sum of the compression forces equals the tension forces.
Forces and lever arms in a reinforced concrete section used in the iterative flexure calculation

The same iterative procedure is used to calculate the neutral axis depth at the serviceability limit state, where the compressed concrete has a triangular stress distribution. 40 iterations are generally enough. The ultimate flexural capacity is calculated as \(M_{\text{ult}} = F_{c} \cdot a_{c} + F_{cs} \cdot a_{cs} + F_{s} \cdot a_{s}\). The design report describes these calculations in detail.

For column members under combined axial force and bending, the module uses the N-M interaction curve. To build this curve, the program needs a number of intermediate points. There are three main points: tracción axial máxima, maximum axial compression and the balanced condition. Intermediate points are then added from the balanced condition to maximum tension, and from the balanced condition to maximum compression. Por defecto, the program uses 40 puntos, and you can change this number.

N-M interaction curve of a reinforced concrete column

For axial force with biaxial bending, the program uses 3D N-Mx-My interaction surfaces based on the Bresler load contour method: it calculates a set of N-M curves separately, then generates the 3D surface from them with the load contour method. The design report describes these calculations in detail.

Strength Reduction and Partial Safety Factors

Para AS 3600, select the reinforcement class. It is used to calculate the strength reduction factor φ.

Strength reduction factor settings for AS 3600 with the reinforcement class

Para uno 2, define the partial safety factors. They are used to calculate the ultimate strength forces.

Partial safety factor settings for Eurocode 2 (EN 2)

Creep Parameters

Serviceability limit state checks, such as crack control, need to account for long-term effects in the concrete. En Creep Parameters, you can define the ages at which creep begins and ends, and the relative humidity (EN 2) or arid environment (AS 3600).

Creep Parameters settings for the long-term effects in the concrete

Miembros

In the standalone module, you can define as many members as you need, each as a beam or a column. Enter the clear length of each member. Column members also need an effective length.

Members table with the member type, clear length and effective length
Members tab of the standalone RC design module

Deflection Coefficient (SkyCiv Beam)

En SkyCiv Beam, where all members are beams, you enter a typical deflection coefficient. It is used to calculate the deflection of the beam with a cracked section.

Deflection coefficient input for a beam member

The table below gives typical deflection coefficients for different cases of beam bending.

Table of typical deflection coefficients for different beam bending cases

Diseños RC

For each member to design, define the section, the reinforcement and the material properties:

  • Sección de: choose the section type and enter its dimensions.
  • Reforzamiento: define the longitudinal reinforcement and the shear reinforcement (estribos). You can place bars at any longitudinal and transverse position in the member. If no shear reinforcement is defined, the design check calculates the shear capacity with the longitudinal reinforcement only.
  •  Materiales: enter the strength properties of the concrete and steel, and the crack width limit.
RC Layouts tab of SkyCiv RC Design, reinforced concrete beam and column design software, with the section, reinforcement and material inputs

Una vez que todos los datos están definidos para el miembro, haga clic en Guarde to apply the RC layout. A layout that is not saved is not used in the design check.

Efectivo

In the standalone module, you enter the design forces manually in two tables: one for the ultimate limit state checks and one for the serviceability limit state checks. Forces are defined at sections along the member, with no limit on the number of sections. Haga clic en Agregar nuevo punto to add a section, then enter its position (como porcentaje de la longitud del miembro) and the forces acting at that location.

Ultimate and serviceability limit state force tables with the Add New Point button

En SkyCiv Beam, the forces are taken automatically from the beam analysis, so you only define the number of sections to design and their positions along the member.

Table of design section positions along the member in SkyCiv Beam

Once all the data is defined, haga clic en Guarde, otherwise it is not used in the design check.

Combinaciones de carga

To use load combinations, first define the load type of each load applied to the beam model.

Load type selection for a load applied to the beam

En el Carga Integrada lengüeta, define all the load combinations needed for the strength and serviceability checks. Por defecto, the program generates a set of standard load combinations for the chosen design code, which you can edit and add to. A load type is only included in a combination if its factor in that combination is not zero.

Load combinations table for the strength and serviceability checks

When the table is complete, haga clic en Guarde.

Resultados

Once all the inputs for the concrete member are complete, haga clic en Comprobar diseño to run the design. El Resultados tab shows the design checks and their capacity ratios: each check, como la flexión, Fuerza de corte y control de grietas., has its own ratio. For a closer look at the design calculations, click the report icon at the end of a row to generate a detailed design report of the checks. The report includes every check formula with its parameters, and detailed hand calculations for the design of the reinforced concrete section.

Design checks and capacity ratios in the Results tab of SkyCiv RC Design, software de diseño de hormigón armado

Empezar

¿Quieres probarlo por ti mismo??

Pruebe SkyCiv hoy gratis!

Regístrate gratis

¿Cómo podemos ayudarle?

×

Actualizado noviembre 24, 2026

¿Sigue teniendo problemas? Contáctenos

Ir arriba