The development length of reinforcement is a critical parameter in structural concrete design, ensuring that reinforcing bars can adequately transfer stresses between the concrete and steel. Sección de 12.2 y 12.3 of CSA A23.3-14 provides the requirements and methodologies for calculating development length to achieve proper anchorage of reinforcement. This ensures structural integrity, la seguridad, and serviceability under various loading conditions. The development length is influenced by bar size, resistencia del concreto, bond conditions, cubrir, espaciado, and whether the bar is in tension or compression. The provision covers basic development lengths for straight bars, adjustments for epoxy coatings, confinement effects, and conditions where bars are hooked or bundled.

The latest SkyCiv Foundation Design update supports standard hooked reinforcements, enabling precise development length checks. Users can now customize footing bar ends as straight bars, 90° hooks, or 180° hooks, ensuring flexibility for various design needs. This guide outlines the step-by-step process for determining the required development length for pad footings following CSA A23.3-14 Section 12, considering relevant modification factors to comply with code requirements.

¿Quieres probar el software de diseño de la fundación SkyCiv?? Nuestra herramienta gratuita permite a los usuarios realizar cálculos de zapatas de concreto sin descargar ni instalar nada!

 

Development Length Check for Dowel Bars

Dowel bars in pad footings ensure a strong connection between the footing and columns, effectively transferring loads and maintaining structural integrity. Factors such as bar diameter, grado de acero, and concrete strength determine the required embedment. Ensure the embedment meets or exceeds the calculated length for safe load transfer and anchorage. Típicamente, column pedestals are subjected to compression loads, and the required development length is calculated using the provisions under Section 12.3.

 

Sección de 12.3.2: Basic compression development length (ldb)

\(l_{db} = MAX \left[ 0.24 \veces d_{b} \frac{ F_{y} }{\sqrt{F'_{c}}}, 0.044 D_{b} F_{y}, 200mm \right]\) Eq.1
Dónde:

Fy = Rebar yield strength (MPa)
F’c = Concrete strength (MPa)
db = Dowel bar diameter (mm)

 

The SkyCiv Foundation Design module checks each load combination to determine if the column is subjected to tensile forces. Si es así, the required development length is calculated following Section 12.5.

Available depth (l)

The available depth should be greater than or equal to the calculated required embedment of the dowel bars. This depth is checked using Equations 2, then compared to the computed development length for the utility ratio.

 

\(l = t – (cubrir + D_{b,x} + D_{b,z}) \) (Eq. 2)

Dónde:

t = Footing Thickness (mm)
cover = Bottom concrete cover (mm)
db,x, db,z = Footing bar size in the x and z directions (mm)

 

Development Length Check For Footing Reinforcements

The SkyCiv Foundation Design module allows users to specify bar end configurations as straight or hooked bars (90° or 180°).

 

Calculating the required development length for footing reinforcements directly influences the footing’s dimensions, ensuring they are adequate to anchor the reinforcement against tensile forces. Sección de 12.2 y 12.5 provides a guide on determining the required development length for footing reinforcements.

Straight bars (Sección de 12.2.3)

\(l_{d} = MAX \left[ 0.45 \times k1 \times k2 \times k3 \times k4 \times \frac{ F_{y} } {\sqrt{ F'_{c}}}\veces d_{b}, 300mm \right]\)
(Eq. 3)
 

\(l_{d} = MAX \left[ 0.6 \times k1 \times k2 \times k3 \times k4 \times \frac{ F_{y} } {\sqrt{ F'_{c}}}\veces d_{b}, 300mm \right]\)
(Eq. 4)

Dónde:

Sección de 12.2.4: Modification factors

Standard hooked bars (Sección de 12.5)

\(l_{hb} = frac{100 D_{b}}{\sqrt{F'_{c}}} \) (Eq. 5)
 

\(l_{dh} = MAX \left[ l_{hb}, 8D_{b}, 150 mm \right]\) (Eq. 6)

The basic development length, lhb, shall be multiplied by applicable modification factors:

Sección de 12.5.3: Factors modifying hook development length

 

Available Development Length

The SkyCiv Foundation Design module assesses the anchorage length on both the left and right sides of each column face. Each anchorage length must meet or exceed the greater of the required development length or the minimum extension length.

\(l_{provided} \geq l_{d,req’d}\) (Eq. 7)

 

Verificación de Detalles: Verification of Footing Thickness (t):

The SkyCiv Foundation Design module checks whether the footing thickness is adequate based on bar configuration and concrete cover. If it is insufficient or the bars protrude, it issues a warning instead of a design failure. The module evaluates the footing thickness at each end of the longitudinal and transverse reinforcements in both the top and bottom layers.

\(\izquierda(\texto{h + cubrir}\verdad) \leq t\) (Eq. 8)

 

¿Quieres probar el software de diseño de la fundación SkyCiv?? Nuestra herramienta gratuita permite a los usuarios realizar cálculos de zapatas de concreto sin descargar ni instalar nada!

 

Desarrollador de productos Wilross Papaya
diseño de análisis de pandeo lateral y diseño de acero conformado en frío
Desarrollador de producto
licenciatura, MEng (Civil)
LinkedIn
¿Te resultó útil este artículo?
Si No

¿Cómo podemos ayudarle?

Ve arriba