This example designs a single plate connection, also called a shear tab, to AISC 360-16 LRFD in SI units. The bolts, the plate and the weld are each checked against the factored beam reaction: bolt shear, bolt bearing and tear-out, block shear, plate shear and flexure, and weld strength, plus the detailing and ductility limits that let the connection rotate as a simple support.
The connection is a W18x35 beam framing into the flange of a W14x90 column with a 142 kN factored reaction, three M20 A325-N bolts and a 10 mm A36M plate, designed to AISC 360-16 and the AISC Manual 15th Edition. All dimensions are in millimetres, forces in kN and stresses in MPa. Every equation is written out with its numbers, in the same order as the AISC calc sheet the SkyCiv Connection Design module produces for it. The same connection type in US customary units is worked in the LRFD version.
What is a single plate connection?
A single plate connection is a steel plate shop-welded to the supporting member and field-bolted to the web of the supported beam. It transfers the beam’s end shear, and it is classified as a simple connection under AISC 360-16 B3.4, so it is detailed to rotate rather than resist moment.
It is the most common shear connection in US steel buildings because it needs one plate, one weld and one line of bolts. The alternatives for the same job are the double angle connection, the single angle connection and the shear end plate connection. You can check this one directly in the single plate connection calculator.

Elevation of the example connection. The plate is welded to the column flange and bolted to the beam web, with the bolt line 52 mm from the weld.

Section A-A. The plate has horizontal short-slotted holes and an 8 mm fillet weld on both sides.

The same connection in the SkyCiv Connection Design 3D view.
How do you design a single plate connection? The steps at a glance
- Check the detailing limits at the beam: bolt spacing, edge distances, plate depth.
- Find the bolt group shear strength with the instantaneous center of rotation.
- Check plate ductility, or confirm the check does not apply.
- Check bolt bearing and tear-out on the plate.
- Check bolt bearing and tear-out on the beam web.
- Combine shear, bearing and tear-out per bolt for the effective group strength.
- Check block shear of the plate.
- Check shear yielding and shear rupture of the plate.
- Check plate flexure using the double coped beam procedure.
- Check shear and flexure interaction for yielding.
- Check shear and flexure interaction for rupture.
- Check the detailing limit at the support.
- Size the weld to develop the plate.
- Check the weld strength to the column flange.
Design inputs for this example
The design code is AISC 360-16 LRFD, so the load is the factored reaction and each strength is multiplied by its resistance factor, φ. The sections are the AISC W shapes, with their dimensions converted to millimetres.
| Item | Symbol | Value |
|---|---|---|
| Factored vertical shear | [mathin] V_{u} [mathin] | 142 kN |
| Beam | W18x35, A992M | |
| Beam depth / web thickness | [mathin] d_{bm},\ t_{wb} [mathin] | 449.58 mm / 7.62 mm |
| Beam flange width / thickness | [mathin] b_{fb},\ t_{fb} [mathin] | 152.4 mm / 10.795 mm |
| Beam yield / tensile stress | [mathin] F_{yb},\ F_{ub} [mathin] | 345 MPa / 450 MPa |
| Column | W14x90, A992M | |
| Column flange thickness | [mathin] t_{fs} [mathin] | 18.034 mm |
| Column yield / tensile stress | [mathin] F_{ys},\ F_{us} [mathin] | 345 MPa / 450 MPa |
| Modulus of elasticity | [mathin] E [mathin] | 200000 MPa |
| Item | Symbol | Value |
|---|---|---|
| Plate (single plate) | PL 10 x 92 x 230, A36M | |
| Plate width / depth / thickness | [mathin] b_{p},\ d_{p},\ t_{p} [mathin] | 92 mm / 230 mm / 10 mm |
| Plate yield / tensile stress | [mathin] F_{yp},\ F_{up} [mathin] | 250 MPa / 400 MPa |
| Bolts | M20 A325-N, single shear | |
| Bolt diameter | [mathin] d_{b} [mathin] | 20 mm |
| Bolt nominal tensile / shear stress | [mathin] F_{nt},\ F_{nv} [mathin] | 620 MPa / 372 MPa |
| Shear planes | [mathin] N_{s} [mathin] | 1 |
| Holes in plate / beam | Short-slotted horizontal (HSSL) / standard (STD) | |
| Weld | 8 mm fillet, both sides, E70XX | |
| Weld size / filler strength | [mathin] W,\ F_{EXX} [mathin] | 8 mm / 480 MPa |
| Geometry | Symbol | Value |
|---|---|---|
| Bolt rows / row spacing | [mathin] n_{r},\ s_{r} [mathin] | 3 / 75 mm |
| Bolt columns / column spacing | [mathin] n_{c},\ s_{c} [mathin] | 1 / 0 mm |
| Beam web clearance to column | [mathin] clr [mathin] | 12 mm |
| Horizontal edge distance on beam web | [mathin] L_{eh,bm} [mathin] | 40 mm |
| Horizontal edge distance on plate | [mathin] L_{eh,pl} [mathin] | 40 mm |
| Vertical edge distance on plate | [mathin] L_{ev,pl} [mathin] | 40 mm |
| Weld line to bolt line | [mathin] a = e [mathin] | 52 mm |
Step 1: Detailing limits at the beam side (AISC 360-16 J3.3, J3.4, J3.5)
Before any strength check, the bolt layout has to be buildable and match the assumptions behind the strength equations. Bolts that are too close tear between the holes, edges that are too close tear out, and a plate that is too short or too deep changes how the connection rotates.
The minimum bolt spacing is 2 2/3 times the bolt diameter (J3.3). The minimum edge distance for an M20 bolt is 26 mm from Table J3.4M. On the plate the horizontal edge is measured across the short slot, so the Table J3.5M increment raises it to 29 mm. The plate must be at least half the beam’s T dimension deep, 196.85 mm for a W18x35. The maximum spacing and the maximum connection depth are the software’s limits for this bolt and beam.
[math] s_{min} = 2\tfrac{2}{3}\, d_{b} = 2.667 \times (20\ \text{mm}) = 53.333\ \text{mm} [math]
| Detailing limit | Limit (mm) | Actual (mm) | DCR | Result |
|---|---|---|---|---|
| Minimum bolt row spacing | 53.333 | 75.000 | 0.711 | PASS |
| Maximum bolt row spacing | 152.400 | 75.000 | 0.492 | PASS |
| Plate minimum vertical edge distance | 26.000 | 40.000 | 0.650 | PASS |
| Plate minimum horizontal edge distance | 29.000 | 40.000 | 0.725 | PASS |
| Beam minimum horizontal edge distance | 26.000 | 40.000 | 0.650 | PASS |
| Minimum connection depth | 196.850 | 230.000 | 0.856 | PASS |
| Maximum connection depth | 406.400 | 230.000 | 0.566 | PASS |
For a minimum limit the ratio is limit over actual, and for a maximum it is actual over limit. The governing row is the minimum connection depth:
[math] DCR = \frac{196.85\ \text{mm}}{230\ \text{mm}} = 0.856 [math]
DCR = 0.856 < 1.0, OK
Step 2: Bolt group shear strength by the instantaneous center of rotation (AISC 360-16 J3.6)
The beam reaction acts away from the bolt line, so the bolts carry a small moment as well as the shear. The instantaneous center of rotation (ICOR) method finds the point the bolt group rotates about and turns that into a coefficient C, the number of bolts’ worth of shear strength the group delivers.
Design eccentricity
The bolt line is 52 mm from the weld, but AISC Manual Table 10-9 sets the design eccentricity for a conventional single plate connection, and for this bolt count and hole type it is half the weld-to-bolt distance:
[math] e = \frac{a}{2} = \frac{52\ \text{mm}}{2} = 26\ \text{mm} [math]
Strength of one bolt
[math] \phi r_{v} = \phi\, F_{nv}\, \frac{\pi}{4} d_{b}^{2}\, N_{s}\, h_{f} [math]
[math] \phi r_{v} = (0.75) \times (372\ \text{MPa}) \times \frac{\pi}{4} (20\ \text{mm})^{2} \times (1) \times (1) [math]
[math] \phi r_{v} = 87.65\ \text{kN} [math]
Here [mathin] h_{f} = 1 [mathin] because there are no fillers (AISC 360-16 J5.2(a)). In SI units the filler expression is:
[math] h_{f} = 1 – 0.015748 \left( t – 6.35\ \text{mm} \right) = 1 – 0.015748 \left( 0\ \text{mm} – 6.35\ \text{mm} \right) \le 1 \;\Rightarrow\; h_{f} = 1 [math]
Locating the instantaneous center
Bolt 1 is at the bottom of the line, with the coordinates below. The IC is found by iteration, using the load-deformation curve of AISC Manual Equation (7-1) on pages 7-6 to 7-8. The bolt group calculation using ICOR walks through that iteration in full.
| Bolt | x (mm) | y (mm) |
|---|---|---|
| 1 | 0.00 | 0.00 |
| 2 | 0.00 | 75.00 |
| 3 | 0.00 | 150.00 |
The iteration converges with the IC at:
[math] x_{ic} = -138.32\ \text{mm}, \qquad y_{ic} = 75\ \text{mm} [math]
The bolt reactions at that location are:
| Bolt | R (kN) | Rx (kN) | Ry (kN) | Mn (kN-mm) |
|---|---|---|---|---|
| 1 | 86.03 | 41.01 | 75.63 | 13536.48 |
| 2 | 85.20 | 0.00 | 85.20 | 11784.59 |
| 3 | 86.03 | -41.01 | 75.63 | 13536.48 |
That gives the two coefficients the calc sheet reports:
[math] C = 2.7 \qquad C’ = 147.23\ \text{mm} [math]
C = 2.7 for three bolts means the 26 mm eccentricity costs the group 10% of its concentric strength. C’ is the coefficient for moment alone.
Bolt group strength
[math] \phi R_{n} = \phi\, F_{nv}\, \frac{\pi}{4} d_{b}^{2}\, N_{s}\, C\, h_{f} [math]
[math] \phi R_{n} = (0.75) \times (372\ \text{MPa}) \times \frac{\pi}{4} (20\ \text{mm})^{2} \times (1) \times (2.7) \times (1) [math]
[math] \phi R_{n} = 236.66\ \text{kN} [math]
DCR = 142 kN / 236.66 kN = 0.600 < 1.0, OK
Step 3: Plate ductility (AISC Manual page 10-90)
A shear tab has to rotate as the beam deflects, and the plate must yield before the bolts break. The AISC Manual gives a maximum plate thickness for that, but for a conventional single plate connection the check is not needed when both horizontal edge distances are at least twice the bolt diameter.
[math] 2 d_{b} = 2 \times (20\ \text{mm}) = 40\ \text{mm} \qquad L_{eh,pl} = 40\ \text{mm} \ge 2 d_{b}, \quad L_{eh,bm} = 40\ \text{mm} \ge 2 d_{b} [math]
Both edge distances meet the limit, so the calc sheet reports the ductility check as not applicable and there is no DCR for this step.
Step 4: Bolt bearing and tear-out on the single plate (AISC 360-16 J3.10)
Each bolt pushes down on the edge of its hole in the plate. The plate either deforms at the hole (bearing, capped at 2.4 d t Fu) or tears a strip out to the next hole or to the bottom edge (tear-out, 1.2 lc t Fu). The bottom bolt has the shortest clear distance, so it is the weak one.
Clear distance for the edge bolt, with [mathin] d_{h} = 22\ \text{mm} [mathin], the hole dimension across the member length:
[math] l_{c1} = L_{ev,pl} – \frac{d_{h}}{2} = 40\ \text{mm} – \frac{22\ \text{mm}}{2} = 29\ \text{mm} [math]
Clear distance between bolts:
[math] l_{c2} = s_{r} – d_{h} = 75\ \text{mm} – 22\ \text{mm} = 53\ \text{mm} [math]
The bearing and tear-out strength of the group, scaled by C / n for the eccentricity:
[math] \phi R_{n} = \phi\, \left[ \min\left(1.2\, l_{c1},\, 2.4\, d_{b}\right) t_{p} F_{up} + \min\left(1.2\, l_{c2},\, 2.4\, d_{b}\right) t_{p} F_{up} \left( n_{r} – 1 \right) \right] \frac{C}{n_{r}} [math]
[math] \phi R_{n} = (0.75) \times \left[ \min\left(34.8,\, 48\right)(10)(400) + \min\left(63.6,\, 48\right)(10)(400)(3 – 1) \right] \times \frac{2.7}{3} [math]
[math] \phi R_{n} = 353.16\ \text{kN} [math]
DCR = 142 kN / 353.16 kN = 0.402 < 1.0, OK
Step 5: Bolt bearing and tear-out on the beam web (AISC 360-16 J3.10)
The same check applies to the beam web. The beam is not coped, so there is no edge for the bolts to tear out to, and every bolt bears like an inner bolt with the clear distance between holes.
[math] l_{c2} = s_{r} – d_{h} = 75\ \text{mm} – 22\ \text{mm} = 53\ \text{mm} [math]
[math] \phi R_{n} = \phi\, \min\left(1.2\, l_{c2},\, 2.4\, d_{b}\right) t_{wb} F_{ub}\, C [math]
[math] \phi R_{n} = (0.75) \times \min\left(1.2 \times 53\ \text{mm},\, 2.4 \times 20\ \text{mm}\right) \times (7.62\ \text{mm}) \times (450\ \text{MPa}) \times (2.7) [math]
[math] \phi R_{n} = 333.3\ \text{kN} [math]
DCR = 142 kN / 333.3 kN = 0.426 < 1.0, OK
The 7.62 mm beam web is thinner than the 10 mm plate, so even with its higher tensile strength (450 MPa against 400 MPa) the web has the lower bearing capacity. Here the 2.4 d t Fu bearing cap governs, not tear-out.
Step 6: Effective strength of the bolt group (AISC 360-16 J3.6 Commentary)
Bolt shear, bearing and tear-out are not really separate checks. Each bolt delivers the least of its shear strength and its bearing or tear-out strength in each ply it passes through, and the group strength is the sum of those per-bolt values, scaled by C / n.
The per-bolt bearing and tear-out strengths, for the plate edge bolt, a plate inner bolt and the beam web:
[math] \phi r_{n1e} = \phi\, \min\left(1.2\, l_{c1},\, 2.4\, d_{b}\right) t_{p} F_{up} = (0.75) \times \min\left(34.8\ \text{mm},\, 48\ \text{mm}\right) \times (10\ \text{mm}) \times (400\ \text{MPa}) = 104.4\ \text{kN} [math]
[math] \phi r_{n1i} = \phi\, \min\left(1.2\, l_{c2},\, 2.4\, d_{b}\right) t_{p} F_{up} = (0.75) \times \min\left(63.6\ \text{mm},\, 48\ \text{mm}\right) \times (10\ \text{mm}) \times (400\ \text{MPa}) = 144\ \text{kN} [math]
[math] \phi r_{n2} = \phi\, \min\left(1.2\, l_{c2},\, 2.4\, d_{b}\right) t_{wb} F_{ub} = (0.75) \times \min\left(63.6\ \text{mm},\, 48\ \text{mm}\right) \times (7.62\ \text{mm}) \times (450\ \text{MPa}) = 123.44\ \text{kN} [math]
Bolts are numbered from the top of the line here, so bolt 3 is the edge bolt on the plate. Bolt shear is 87.65 kN per bolt from Step 2:
| Bolt | Bolt shear (kN) | Bearing / tear-out on the plate (kN) | Bearing on the beam web (kN) | Effective strength (kN) |
|---|---|---|---|---|
| 1, 2 | 87.65 | 144 | 123.44 | 87.65 |
| 3 | 87.65 | 104.4 | 123.44 | 87.65 |
[math] \sum \phi r_{eff} = n_{1}\, \phi r_{eff,1} + n_{2}\, \phi r_{eff,2} = (2) \times (87.65\ \text{kN}) + (1) \times (87.65\ \text{kN}) = 262.95\ \text{kN} [math]
[math] \phi R_{n,eff} = \frac{C}{n_{r}} \sum \phi r_{eff} = \frac{2.7}{3} \times (262.95\ \text{kN}) = 236.66\ \text{kN} [math]
DCR = 142 kN / 236.66 kN = 0.600 < 1.0, OK
All three bolts are limited by bolt shear, 87.65 kN each, so this check gives the same 236.66 kN as Step 2.
Step 7: Block shear of the single plate (AISC 360-16 J4.3)
A block of the plate can tear out along the bolt line: shear down the line of holes plus tension across the short leg to the plate’s free edge. With one bolt column this is an L-shaped block.
The net tension area uses the hole dimension along the member length, [mathin] d_{h} = 26\ \text{mm} [mathin], because the slots run horizontally. Each hole adds 2 mm for damage during punching (B4.3):
[math] A_{nt} = t_{p} \left[ (n_{c}-1)\, s_{c} + L_{eh,pl} – (n_{c} – 0.5)\left( d_{h} + 2\ \text{mm} \right) \right] = (10\ \text{mm}) \times \left[ 40\ \text{mm} – (0.5)(26\ \text{mm} + 2\ \text{mm}) \right] = 260\ \text{mm}^{2} [math]
Gross and net shear areas, with [mathin] d_{h} = 22\ \text{mm} [mathin] across the member length:
[math] A_{gv} = t_{p} \left[ L_{ev,pl} + (n_{r}-1)\, s_{r} \right] = (10\ \text{mm}) \times \left[ 40\ \text{mm} + (2)(75\ \text{mm}) \right] = 1900\ \text{mm}^{2} [math]
[math] A_{nv} = t_{p} \left[ d_{p} – L_{ev,pl} – (n_{r} – 0.5)\left( d_{h} + 2\ \text{mm} \right) \right] = (10\ \text{mm}) \times \left[ 230\ \text{mm} – 40\ \text{mm} – (2.5)(24\ \text{mm}) \right] = 1300\ \text{mm}^{2} [math]
Block shear strength, with [mathin] U_{bs} = 1 [mathin] for uniform tension:
[math] \phi R_{n} = \phi\, \left[ \min\left( 0.6\, F_{up} A_{nv},\; 0.6\, F_{yp} A_{gv} \right) + U_{bs} F_{up} A_{nt} \right] [math]
[math] \phi R_{n} = (0.75) \times \left[ \min\left( 0.6 \times 400 \times 1300,\; 0.6 \times 250 \times 1900 \right) + 1 \times 400 \times 260 \right] [math]
[math] \phi R_{n} = 291.75\ \text{kN} [math]
DCR = 142 kN / 291.75 kN = 0.487 < 1.0, OK
Shear yielding on the gross area (285 kN before the resistance factor) is lower than shear rupture on the net area, so the yielding branch sets the block shear strength.
Step 8: Shear yielding and shear rupture of the single plate (AISC 360-16 J4.2)
The full reaction passes through the plate as vertical shear. The gross section must not yield, and the net section through the bolt holes must not rupture.
Shear yielding (Eq. J4-3)
[math] A_{gv} = d_{p}\, t_{p} = (230\ \text{mm}) \times (10\ \text{mm}) = 2300\ \text{mm}^{2} [math]
[math] \phi R_{n,sy} = \phi\, 0.6\, F_{yp} A_{gv} = (1.00) \times 0.6 \times (250\ \text{MPa}) \times (2300\ \text{mm}^{2}) = 345\ \text{kN} [math]
Shear rupture (Eq. J4-4)
[math] A_{nv} = t_{p} \left[ d_{p} – n_{r}\left( d_{h} + 2\ \text{mm} \right) \right] = (10\ \text{mm}) \times \left[ 230\ \text{mm} – 3 \times (24\ \text{mm}) \right] = 1580\ \text{mm}^{2} [math]
[math] \phi R_{n,sr} = \phi\, 0.6\, F_{up} A_{nv} = (0.75) \times 0.6 \times (400\ \text{MPa}) \times (1580\ \text{mm}^{2}) = 284.4\ \text{kN} [math]
[math] \phi R_{n} = \min\left( 345\ \text{kN},\, 284.4\ \text{kN} \right) = 284.4\ \text{kN} [math]
DCR = 142 kN / 284.4 kN = 0.499 < 1.0, OK
Step 9: Plate flexure using the double coped beam procedure (AISC 360-16 F11.2)
The reaction acts 52 mm from the weld, so the plate is a short cantilever in bending. A deep, thin plate can buckle sideways before it yields. The AISC Manual handles this with the procedure for a beam coped at both flanges, treating the plate like a beam web with the flanges cut away. The unbraced length is the weld-to-bolt distance, [mathin] L_{b} = 52\ \text{mm} [mathin].
Flexural yielding and lateral-torsional buckling
First, confirm the plate is in the range where Eq. F11-2 applies:
[math] \frac{L_{b} d}{t^{2}} = \frac{(52\ \text{mm})(230\ \text{mm})}{(10\ \text{mm})^{2}} = 119.6 [math]
[math] \frac{0.08 E}{F_{y}} = \frac{0.08 \times 200000\ \text{MPa}}{250\ \text{MPa}} = 64 \lt 119.6 \le \frac{1.9 E}{F_{y}} = \frac{1.9 \times 200000\ \text{MPa}}{250\ \text{MPa}} = 1520 [math]
Section moduli of the plate:
[math] Z = \frac{t_{p} d_{p}^{2}}{4} = \frac{(10\ \text{mm})(230\ \text{mm})^{2}}{4} = 132250\ \text{mm}^{3} \qquad S = \frac{t_{p} d_{p}^{2}}{6} = \frac{(10\ \text{mm})(230\ \text{mm})^{2}}{6} = 88167\ \text{mm}^{3} [math]
Lateral-torsional buckling modification factor, AISC Manual Eq. (9-15), with no cope ([mathin] d_{ct} = 0 [mathin]):
[math] C_{b} = \left[ 3 + \ln\left( \frac{L_{b}}{d_{p}} \right) \right] \left( 1 – \frac{d_{ct}}{d_{p}} \right) \ge 1.84 [math]
[math] C_{b} = \left[ 3 + \ln\left( \frac{52\ \text{mm}}{230\ \text{mm}} \right) \right] \times \left( 1 – \frac{0\ \text{mm}}{230\ \text{mm}} \right) \ge 1.84 \;\Rightarrow\; C_{b} = 1.84 [math]
[math] \phi M_{n} = \phi\, \min\left\{ C_{b} \left[ 1.52 – 0.274 \left( \frac{L_{b} d}{t^{2}} \right) \left( \frac{F_{yp}}{E} \right) \right] F_{yp} S,\; F_{yp} Z \right\} [math]
[math] \phi M_{n} = (0.9) \times \min\left\{ (1.84) \left[ 1.52 – 0.274 \times (119.6) \times \frac{250}{200000} \right] (250)(88167),\; (250)(132250) \right\} [math]
[math] \phi M_{n} = 29.756\ \text{kN-m} [math]
The plastic moment cap governs, so the plate does not buckle sideways at this depth and thickness. As an equivalent shear at the bolt line:
[math] \phi V_{n,y} = \frac{\phi M_{n}}{L_{b}} = \frac{29.756\ \text{kN-m}}{52\ \text{mm}} = 572.24\ \text{kN} [math]
Flexural rupture on the net section
The net plastic section modulus through the holes, from AISC Manual Part 15 Table 15-3:
[math] Z_{net} = \frac{t_{p} d_{p}^{2}}{4} – t_{p}\left( d_{h} + 2\ \text{mm} \right) s_{r} \left\lfloor \frac{n_{r}^{2}}{4} \right\rfloor – \left[ n_{r}\ \text{odd} \right] \frac{t_{p}\left( d_{h} + 2\ \text{mm} \right)^{2}}{4} [math]
[math] Z_{net} = \frac{(10)(230)^{2}}{4} – (10)(24)(75) \left\lfloor \frac{9}{4} \right\rfloor – (1) \frac{(10)(24)^{2}}{4} = 94810\ \text{mm}^{3} [math]
[math] \phi M_{n} = \phi\, F_{up} Z_{net} = (0.75) \times (400\ \text{MPa}) \times (94810\ \text{mm}^{3}) = 28.443\ \text{kN-m} [math]
[math] \phi V_{n,r} = \frac{28.443\ \text{kN-m}}{52\ \text{mm}} = 546.98\ \text{kN} [math]
[math] \phi V_{n} = \min\left( 572.24\ \text{kN},\, 546.98\ \text{kN} \right) = 546.98\ \text{kN} [math]
DCR = 142 kN / 546.98 kN = 0.260 < 1.0, OK
Step 10: Shear and flexure interaction of the single plate, yielding (AISC Manual Part 10)
The plate carries shear and bending at the same section at the same time, so the two are checked together. The Manual uses a circular interaction, done once with the yielding strengths and once with the rupture strengths.
[math] \left( \frac{V_{u}}{\phi V_{n,y}} \right)^{2} + \left( \frac{V_{u}}{\phi R_{n,sy}} \right)^{2} = \left( \frac{142\ \text{kN}}{572.24\ \text{kN}} \right)^{2} + \left( \frac{142\ \text{kN}}{345\ \text{kN}} \right)^{2} = 0.231 [math]
DCR = 0.231 < 1.0, OK
Step 11: Shear and flexure interaction of the single plate, rupture (AISC Manual Part 10)
[math] \left( \frac{V_{u}}{\phi V_{n,r}} \right)^{2} + \left( \frac{V_{u}}{\phi R_{n,sr}} \right)^{2} = \left( \frac{142\ \text{kN}}{546.98\ \text{kN}} \right)^{2} + \left( \frac{142\ \text{kN}}{284.4\ \text{kN}} \right)^{2} = 0.317 [math]
DCR = 0.317 < 1.0, OK
Step 12: Detailing limit at the support side
The fillet weld sits in the gap between the column flange and the end of the beam, so the weld cannot be larger than the beam clearance or the beam will not fit.
[math] DCR = \frac{W}{clr} = \frac{8\ \text{mm}}{12\ \text{mm}} = 0.667 [math]
DCR = 0.667 < 1.0, OK
Step 13: Weld required to develop the single plate (AISC Manual page 10-87)
The plate is meant to yield before anything brittle happens, and that only works if the weld does not fail first. Two fillet welds, each at least 5/8 of the plate thickness, develop the plate’s strength.
[math] W_{duc} = \frac{5}{8}\, t_{p} = \frac{5}{8} \times (10\ \text{mm}) = 6.25\ \text{mm} [math]
DCR = 6.25 mm / 8 mm = 0.781 < 1.0, OK
Step 14: Fillet weld strength to the column flange (AISC 360-16 J2.4)
Last, the welds have to carry the reaction itself. Their strength depends on size, length and load direction. The base metal on either side of the weld, here the plate and the column flange, can also limit how much of the weld size counts.
Base metal limit on weld size (AISC Manual Eq. 9-2)
The largest weld size, in sixteenths of an inch, that the thinner connected part can support. The plate is welded both sides, so half its thickness is available to each weld:
[math] D_{max} = \frac{ \min\left( \frac{t_{p}}{2} F_{up},\; t_{fs} F_{us} \right) }{0.54114\ \text{kN/mm} \times \left( F_{EXX} / F_{E70XX} \right)} = \frac{ \min\left( (5\ \text{mm})(400\ \text{MPa}),\; (18.034\ \text{mm})(450\ \text{MPa}) \right) }{(0.54114\ \text{kN/mm})(1)} = 3.6959 [math]
The 0.54114 kN/mm is the 3.09 kip/in of the Manual equation in SI units, so [mathin] D_{max} [mathin] is still in sixteenths of an inch. Dividing it by 0.62992 (16/25.4) turns it into millimetres: 3.6959 / 0.62992 = 5.867 mm. Only that much of the 8 mm weld size counts, so the 10 mm A36M plate, not the weld, limits the weld strength.
Effective length
Two lines of weld, each reduced by 2W at the ends:
[math] L_{w} = 2 \left( d_{p} – 2W \right) = 2 \times \left[ 230\ \text{mm} – 2 \times (8\ \text{mm}) \right] = 428\ \text{mm} [math]
Weld strength
The load runs parallel to the welds, so [mathin] \theta = 0 [mathin] and there is no directional increase:
[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left( W,\, \frac{D_{max}}{0.62992} \right) \left[ 1 + 0.5 \sin^{1.5}\theta \right] L_{w} [math]
[math] \phi R_{n} = (0.75) \times 0.6 \times (480\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (5.867\ \text{mm}) \times \left[ 1 + 0.5 \sin^{1.5}(0) \right] \times (428\ \text{mm}) [math]
[math] \phi R_{n} = 383.54\ \text{kN} [math]
DCR = 142 kN / 383.54 kN = 0.370 < 1.0, OK
Summary of design checks
| Design check | Demand | Design strength | DCR | Result |
|---|---|---|---|---|
| 1. Detailing limits at the beam side | 196.85 mm | 230 mm | 0.856 | PASS |
| **2. Bolt group shear (ICOR)** | **142 kN** | **236.66 kN** | **0.600** | **PASS** |
| 3. Plate ductility | Not applicable | |||
| 4. Bearing and tear-out on the plate | 142 kN | 353.16 kN | 0.402 | PASS |
| 5. Bearing and tear-out on the beam web | 142 kN | 333.30 kN | 0.426 | PASS |
| 6. Effective strength of the bolt group | 142 kN | 236.66 kN | 0.600 | PASS |
| 7. Block shear of the plate | 142 kN | 291.75 kN | 0.487 | PASS |
| 8. Shear yielding and rupture of the plate | 142 kN | 284.40 kN | 0.499 | PASS |
| 9. Plate flexure | 142 kN | 546.98 kN | 0.260 | PASS |
| 10. Shear and flexure interaction, yielding | 0.231 | 1.000 | 0.231 | PASS |
| 11. Shear and flexure interaction, rupture | 0.317 | 1.000 | 0.317 | PASS |
| 12. Detailing limit at the support side | 8 mm | 12 mm | 0.667 | PASS |
| 13. Weld to develop the plate | 6.25 mm | 8 mm | 0.781 | PASS |
| 14. Weld to the column flange | 142 kN | 383.54 kN | 0.370 | PASS |
The connection passes every check. Bolt shear governs the strength checks at 0.600, and the effective bolt group strength in Step 6 lands on the same value because all three bolts are limited by bolt shear. Plate shear rupture (0.499) and block shear (0.487) come next. The minimum connection depth is the highest ratio on the page at 0.856, and the weld to develop the plate is 0.781, which compares weld size with plate thickness rather than load with capacity.
What to change if a check fails
- Bolt group shear or effective strength: add a bolt row, which raises C, or use a larger bolt. Moving the bolt line closer to the weld reduces e and raises C.
- Bearing on the beam web: this depends on the web thickness and grade, so add a bolt row or pick a heavier beam.
- Tear-out on the plate: increase the vertical edge distance below the bottom bolt.
- Block shear, shear rupture or flexural rupture: make the plate deeper with another bolt row, or make it thicker.
- Plate ductility: keep both horizontal edge distances at least twice the bolt diameter, or the plate thickness has to be checked against the bolt group’s moment strength.
- Weld to develop the plate: increase the weld to 5/8 of the plate thickness, provided it still fits within the beam clearance.
- Weld strength: a thicker plate or a longer plate raises it. A larger weld only helps up to the base metal limit in Step 14.
Auto Design is available for the single plate connection to a column flange. It changes the connection’s design variables until every check passes, and keeps your members and loads as entered. See the Auto Design page for the preferences it works to.
Frequently asked questions
How does this metric example differ from the LRFD version?
The method is the same AISC 360-16 LRFD design with the same resistance factors. The inputs are in millimetres, kN and MPa, the bolts are M20 and the plate and members use the metric ASTM grades A36M and A992M, so the edge distance limits come from Table J3.4M and the hole damage allowance is 2 mm instead of 1/16 in. The LRFD version works a different connection in US customary units, so its numbers are not a direct conversion of these.
Why is the bolt group designed for a 26 mm eccentricity when the bolts are 52 mm from the weld?
AISC Manual Table 10-9 sets the design eccentricity for a conventional single plate connection based on the number of bolts and the hole type. For this three-bolt connection it is half the distance from the weld line to the bolt line, so 52 mm becomes 26 mm. The weld is then designed for the reaction alone.
Why is there no plate ductility check?
AISC Manual page 10-90 only requires the maximum plate thickness check for a conventional single plate connection when an edge distance is short. Here both the plate and the beam web have horizontal edge distances of at least twice the bolt diameter, so the calc sheet reports the check as not applicable.
Why does the plate use short-slotted holes?
Horizontal short slots in the plate let the beam end rotate and give the erector some fit-up tolerance, both of which suit a simple connection. Because the slots run perpendicular to the vertical load, the bearing and tear-out checks use the hole dimension across the slot, and block shear uses the slot length for the tension area.
Which check usually governs a shear tab?
With high-strength bolts and a reasonably thick beam web, bolt shear often governs, as it does here at 0.600. On lighter beams with thinner webs, bearing on the beam web usually takes over.
Does this example follow the AISC 15th edition or the AISC 16th edition Manual?
It follows AISC 360-16 and the AISC Manual 15th Edition, which is written around that Specification. The AISC 16th Edition Manual pairs with the later 360-22 Specification. The limit states for a single plate connection are the same in both, but clause and page references move, so check them against the edition your project uses.
Design a single plate connection for free
Every number on this page comes from one solve. Pick the single plate configuration, choose AISC 360-16 LRFD with metric units, enter your beam, support, bolts and reaction, and see each of these checks in your browser. There is nothing to install.
The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every capacity and DCR, for AISC 360-22 and AISC 360-16 (LRFD and ASD) and AS 4100:2020. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.
References
- AISC 360-16, Specification for Structural Steel Buildings: B3.4, B4.3, F11.2 (Eq. F11-2), J2.4, J3.3, J3.4 (Table J3.4M), J3.5 (Table J3.5M), J3.6 (Eq. J3-1) and Commentary, J3.10 (Eq. J3-6a, J3-6c), J4.2 (Eq. J4-3, J4-4), J4.3, J5.2(a).
- AISC Steel Construction Manual, 15th Edition: Part 7, pages 7-6 to 7-8 (Eq. 7-1); Part 9, Eq. 9-2, 9-4 and 9-15; Part 10, Table 10-9 and pages 10-87 and 10-90; Part 15, Table 15-3.
- Single plate shear connection design, LRFD version
- Bolt group calculation using ICOR
- Design of steel connections using AISC 360-16
- Bolts and welds in SkyCiv Connection Design
Harold Munalem
Product Manager, Connection Design
10+ years in steel connection design
LinkedIn