SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

Flange Plate Moment Connection to HSS Column Design

To design a bolted flange plate moment connection to a rectangular HSS column to AISC 360-16, you turn the beam moment into a tension and compression force in each flange, check the flange plates, bolts and beam flanges for that force, and then check what the force does to the tube: the weld to the HSS face, local yielding of the plate on a flexible wall, and local yielding of the HSS sidewalls. A single plate on the beam web carries the shear.

This page works through one example: a W18x50 beam framing into the 4 in face of an HSS8x4x1/2 column, with 38 kip-ft moment, 19 kip shear and 66 kip axial under LRFD, 3/4 in Grade 50 flange plates on four 1 in A490-SC bolts each, and a 3/8 in A36 shear plate. Every equation is written out with its numbers, in the same order as the calc sheet the SkyCiv Connection Design module produces for it.

What is a flange plate moment connection to an HSS column?

A flange plate moment connection has one plate on the top flange and one on the bottom flange of the beam. Each plate is shop-welded to the column and field-bolted to the beam flange, so the moment passes through the plates as a tension and compression couple. A shear plate on the web takes the beam reaction. For a W-shape column the plates weld to the column flange, as in How to Design a Flange Plate Moment Connection.

On an HSS column the plates weld straight onto the tube wall, which is much more flexible than a column flange. A plate pulling on the middle of a thin wall cannot spread its force evenly across its width, so AISC reduces the plate to an effective width, and the sidewalls of the tube are checked for the force coming in from the corners. Those HSS checks are the part of the design this page adds to the W-shape example.

You can run this connection in the flange plate connection calculator.

Elevation: W18x50 beam with bolted top and bottom flange plates and a shear plate, welded to an HSS8x4x1/2 column

Elevation of the example connection. The flange plates are welded to the HSS face and bolted to the beam flanges; the shear plate carries the reaction.

Plan section A-A of the 3/4 in x 6 1/2 in flange plate with four 1 in A490-SC bolts, welded to the 4 in HSS face

Section A-A, a plan cut through the top flange plate, showing the four bolts at a 3 5/8 in gage and the plate against the 4 in HSS face.

3D view of the flange plate moment connection: W18x50 beam framing into a rectangular HSS8x4x1/2 column

3D view of the connection in SkyCiv Connection Design.

How do you design a flange plate moment connection to an HSS column? The steps at a glance

The report has two sections: the flange plates (Steps 1 to 14) and the shear plate (Steps 15 to 24).

  1. Detailing limits at the beam flange.
  2. Flange bolts in slip under the flange force.
  3. Bolt bearing on the flange plate.
  4. Bolt bearing on the beam flange.
  5. Block shear of the flange plate.
  6. Block shear of the beam flange.
  7. Tension yielding and rupture of the flange plate.
  8. Tension rupture of the beam flange.
  9. Flexural rupture of the beam at the flange bolt holes.
  10. Compression of the flange plate.
  11. Detailing limit at the HSS face.
  12. Fillet weld from the flange plate to the HSS face.
  13. Local yielding of the flange plate on the HSS wall.
  14. Local yielding of the HSS sidewalls.
  15. Detailing limits of the shear plate at the beam.
  16. Shear plate bolt group.
  17. Bearing on the shear plate.
  18. Bearing on the beam web.
  19. Effective strength of the web bolt group.
  20. Block shear of the shear plate.
  21. Shear yielding and rupture of the shear plate.
  22. Detailing limits of the shear plate at the HSS wall.
  23. Weld from the shear plate to the HSS wall.
  24. HSS wall punching.

Design inputs for this example

The design code is AISC 360-16 LRFD. Section properties are from the AISC Manual. How the loads are entered is explained in loads and load combinations.

ItemSymbolValue
Factored moment (strong axis)[mathin] M_{ux} [mathin]38 kip-ft
Factored shear[mathin] V_{u} [mathin]19 kip
Factored axial tension / compression[mathin] T_{u},\ C_{u} [mathin]66 kip / 66 kip
BeamW18x50, ASTM A992
Beam depth / web thickness[mathin] d_{bm},\ t_{wb} [mathin]18 in / 0.355 in
Beam flange width / thickness[mathin] b_{fb},\ t_{fb} [mathin]7.5 in / 0.57 in
Beam area / yield / tensile strength[mathin] A,\ F_{yb},\ F_{ub} [mathin]14.7 in² / 50 ksi / 65 ksi
ColumnHSS8x4x1/2, ASTM A500 Gr. C
Width of the HSS face the plates weld to[mathin] b [mathin]4 in
HSS depth / design wall thickness[mathin] h,\ t [mathin]8 in / 0.465 in
Workable flat of the face[mathin] W_{flat} [mathin]2.875 in
Column yield / tensile strength[mathin] F_{ys},\ F_{us} [mathin]50 ksi / 62 ksi
Flange plate itemSymbolValue
Flange platesPL 3/4 x 6 1/2 x 6 1/2, ASTM A572 Gr. 50 (50 / 65 ksi)
Plate width / length / thickness[mathin] b_{fp},\ L_{fp},\ t_{fp} [mathin]6.5 in / 6.5 in / 0.75 in
Flange bolts1 in A490-SC, Class A, 1 shear plane
HolesFlange plate: oversized (OVS). Beam flange: standard (STD)
Bolt lines / gage[mathin] n_{r},\ g_{a} [mathin]2 / 3.625 in
Bolts per line / spacing[mathin] n_{c},\ s_{c} [mathin]2 / 3 in
Plate edge distances, across / along the beam[mathin] L_{ev\_fp},\ L_{eh\_fp} [mathin]1.4375 in / 1.5 in
Beam flange edge distances, across / along[mathin] L_{ev\_bf},\ L_{eh\_bf} [mathin]1.9375 in / 1.5 in
Erection gap1/4 in
Weld to HSS face1/2 in fillet, E70XX
Shear plate itemSymbolValue
Shear platePL 3/8 x 3 1/2 x 9, ASTM A36 (36 / 58 ksi)
Web bolts1 in A490-N, threads included
HolesPlate: horizontal short-slotted (HSSL). Beam web: standard (STD)
Bolt rows / spacing / columns[mathin] n_{r},\ s_{r},\ n_{c} [mathin]3 / 3 in / 1
Edge distances / weld to bolt line[mathin] L_{e},\ a [mathin]1.5 in / 2 in
Weld to HSS face3/16 in fillet both sides, E70XX

Flange plate section

Step 1: Detailing limits at the beam flange (AISC 360-16 J3.3, J3.4)

The bolt gage across the flange, the spacing along it and the edge distances on both the plate and the beam flange are checked against the J3.3 and Table J3.4 limits for a 1 in bolt, with the oversized-hole increment on the plate.

Detailing limitLimit (in)Actual (in)DCRResult
Minimum gage3.6253.6251.000PASS
Minimum bolt column spacing2.6673.0000.889PASS
Maximum bolt column spacing6.0003.0000.500PASS
Plate minimum vertical edge distance1.3751.4380.956PASS
Plate minimum horizontal edge distance1.3751.5000.917PASS
Beam flange minimum vertical edge distance1.2501.9380.645PASS
Beam flange minimum horizontal edge distance1.2501.5000.833PASS

The gage equals the module’s minimum gage, so that row sits at exactly 1.000:

[math] DCR = \frac{3.625\,in}{3.625\,in} = 1.000 [math]

DCR = 1.000, OK

Step 2: Flange bolts in slip under the flange force (AISC 360-16 J3.8)

The moment becomes a force in each flange over the distance between flange centers, and half the axial force is added to it:

[math] P_{uF} = \frac{M_{ux}}{d_{bm} – t_{fb}} + \frac{P_{u}}{2} = \frac{38\,kip\text{-}ft}{18\,in – 0.57\,in} + \frac{66\,kip}{2} = 59.162\,kip [math]

This flange force is the demand for every check in the flange plate section. The four bolts are slip-critical, Eq. J3-4, with the report’s filler factor of 0.85:

[math] \phi R_{n} = \phi\, \mu\, D_{u}\, h_{f}\, T_{b}\, N_{s}\, n_{r}\, n_{c} = (0.85) \times (0.3) \times (1.13) \times (0.85) \times (64\,kip) \times (1) \times (2) \times (2) = 62.701\,kip [math]

DCR = 59.162 kip / 62.701 kip = 0.944 < 1.0, OK

Step 3: Bolt bearing on the flange plate (AISC 360-16 J3.10)

The force runs along the beam, so the bolts bear toward the plate end. With the 1.25 in oversized hole:

[math] l_{c1} = 1.5 – \frac{1.25}{2} = 0.875\,in, \qquad l_{c2} = 3 – 1.25 = 1.75\,in [math]

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.875, 2.4) \times 0.75 \times 65 \times 2 + \min(1.2 \times 1.75, 2.4) \times 0.75 \times 65 \times 2 \times 1 \right] = 230.34\,kip [math]

DCR = 59.162 kip / 230.34 kip = 0.257 < 1.0, OK

Step 4: Bolt bearing on the beam flange (AISC 360-16 J3.10)

[math] l_{c1} = 1.5 – \frac{1.125}{2} = 0.9375\,in, \qquad l_{c2} = 1.875\,in [math]

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.57 \times 65 \times 2 + \min(1.2 \times 1.875, 2.4) \times 0.57 \times 65 \times 2 \times 1 \right] = 187.57\,kip [math]

DCR = 59.162 kip / 187.57 kip = 0.315 < 1.0, OK

Step 5: Block shear of the flange plate (AISC 360-16 J4.3)

Three tear-out shapes are checked, all with [mathin] U_{bs} = 1 [mathin] and Eq. J4-5:

[math] \phi R_{n} = \phi \left( 0.6 F_{up} A_{nv} + U_{bs} F_{up} A_{nt} \le 0.6 F_{yp} A_{gv} + U_{bs} F_{up} A_{nt} \right) [math]

PatternAgv (in²)Anv (in²)Ant (in²)phi Rn (kip)
L: one shear plane, tension across the bolts to one edge3.3751.89842.3203168.64
U: two shear planes, tension between the bolt lines6.753.79691.7344195.61
2L: two shear planes, tension from each bolt line to its edge6.753.79691.1719168.19

For the governing 2L pattern:

[math] A_{nt} = 2 \times 0.75 \left[ 1.4375 – 0.5 \times (1.25 + 0.0625) \right] = 1.1719\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.7969 + 65 \times 1.1719 \le 0.6 \times 50 \times 6.75 + 65 \times 1.1719 \right) = 168.19\,kip [math]

DCR = 59.162 kip / 168.19 kip = 0.352 < 1.0, OK

Step 6: Block shear of the beam flange (AISC 360-16 J4.3)

The beam flange tears out as two outer strips:

[math] A_{nt} = 0.57 \left[ 7.5 – 3.625 – 1 \times (1.1875) \right] = 1.5319\,in^{2} [math]

[math] A_{gv} = 2 \times 0.57 \left[ 1.5 + 3 \right] = 5.13\,in^{2}, \qquad A_{nv} = 2 \times 0.57 \left( 4.5 – 1.5 \times 1.1875 \right) = 3.0994\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.0994 + 65 \times 1.5319 \le 0.6 \times 50 \times 5.13 + 65 \times 1.5319 \right) = 165.34\,kip [math]

DCR = 59.162 kip / 165.34 kip = 0.358 < 1.0, OK

Step 7: Tension yielding and rupture of the flange plate (AISC 360-16 J4.1)

[math] \phi R_{n\_ty} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]

[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.75 \left[ 6.5 – 2 \times (1.3125) \right] = 141.68\,kip [math]

DCR = 59.162 kip / 141.68 kip = 0.418 < 1.0, OK

Step 8: Tension rupture of the beam flange (AISC 360-16 D3, J4.1)

The flange force is taken by half the beam’s area, less the two flange holes, with the shear lag factor U = 0.283 from Table D3.1 case 2:

[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.283 \left[ 0.5 \times 14.7 – 2 \times (1.1875) \times 0.57 \right] = 82.726\,kip [math]

DCR = 59.162 kip / 82.726 kip = 0.715 < 1.0, OK

Step 9: Flexural rupture of the beam at the flange bolt holes (AISC 360-16 F13.1)

[math] A_{fg} = 7.5 \times 0.57 = 4.275\,in^{2}, \qquad A_{fn} = 4.275 – 2 \times (1.1875) \times 0.57 = 2.9213\,in^{2} [math]

With Fy / Fu = 0.76923, no more than 0.8, Yt = 1. Then:

[math] F_{u} A_{fn} = 189.88\,kip \lt Y_{t} F_{y} A_{fg} = 213.75\,kip [math]

so the holes reduce the flexural strength and Eq. F13-1 applies, with the beam’s elastic modulus of 89.005 in³:

[math] M_{n} = \frac{F_{ub} A_{fn}}{A_{fg}}\, S_{x} = \frac{65 \times 2.9213}{4.275} \times 89.005 = 329.44\,kip\text{-}ft [math]

[math] \phi R_{n} = \frac{0.9\, M_{n}}{d_{bm} – t_{fb}} = \frac{0.9 \times 329.44\,kip\text{-}ft}{18\,in – 0.57\,in} = 204.13\,kip [math]

DCR = 59.162 kip / 204.13 kip = 0.290 < 1.0, OK

Step 10: Compression of the flange plate (AISC 360-16 J4.4)

KL/r of the plate is no more than 25, so Eq. J4-6 applies with no buckling reduction:

[math] \phi R_{n} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]

DCR = 59.162 kip / 219.38 kip = 0.270 < 1.0, OK

Step 11: Detailing limit at the HSS face

Detailing limitLimit (in)Actual (in)DCRResult
Maximum fillet weld size per beam clearance0.5000.5001.000PASS

The 1/2 in weld exactly fills the available clearance, which is allowed:

DCR = 1.000, OK

Step 12: Fillet weld from the flange plate to the HSS face (AISC 360-16 K1, K5, J2.4)

This is where the HSS changes the design. The base metal limit first, from Manual Eq. 9-2:

[math] D_{max} = \frac{(0.375)(65) \le (0.465)(62)}{3.09} = 7.8883 [math]

The 6.5 in plate is wider than the 4 in HSS face. The report allows that, but only the width over the face delivers load into it:

[math] B_{p,eff} = b_{fp} \le b = \min(6.5\,in, 4\,in) = 4\,in [math]

Eq. K1-1 then reduces it to the effective width:

[math] B_{e} = \left( \frac{10 t}{b} \right) \left( \frac{F_{ys}\, t}{F_{yp}\, t_{fp}} \right) B_{p,eff} \le B_{p,eff} = \left( \frac{10 \times 0.465}{4} \right) \left( \frac{50 \times 0.465}{50 \times 0.75} \right) \times 4 = 2.883\,in [math]

Per K5 the effective weld length is 2Be, and the report also caps Be at the workable flat:

[math] L_{w} = 2 \left( B_{e} \le W_{flat} \right) = 2 \times \min(2.883, 2.875) = 5.75\,in [math]

[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.5, \frac{7.8883}{16}\right) \times 5.75 = 63.144\,kip [math]

DCR = 59.162 kip / 63.144 kip = 0.937 < 1.0, OK

Step 13: Local yielding of the flange plate on the HSS wall (AISC 360-16 K1, Design Guide 24)

The same effective width idea limits the force the plate can deliver into the wall. The report uses φ = 0.95 from AISC Design Guide 24, Table 7-2:

[math] \phi R_{n} = \phi \left( \frac{10\, t^{2}\, F_{ys}\, B_{p,eff}}{b} \le F_{yp}\, t_{fp}\, B_{p,eff} \right) = 0.95 \times \min\left( \frac{10 \times 0.465^{2} \times 50 \times 4}{4},\; 50 \times 0.75 \times 4 \right) = 102.71\,kip [math]

DCR = 59.162 kip / 102.71 kip = 0.576 < 1.0, OK

Step 14: Local yielding of the HSS sidewalls

The flange force also reaches the two sidewalls of the tube through the corners. The report checks them with the expression below and φ = 1.0, without citing a clause, so it is the software’s limit for this check:

[math] \phi R_{n} = \phi \times 2 F_{ys}\, t \left[ 5 (1.5 t) + t_{fp} \right] = 1.0 \times 2 \times 50 \times 0.465 \left[ 5 \times (1.5 \times 0.465) + 0.75 \right] = 197.04\,kip [math]

DCR = 59.162 kip / 197.04 kip = 0.300 < 1.0, OK

Shear plate section

The shear plate is a conventional single plate welded to the HSS face and carries the 19 kip reaction. Its checks follow the shear tab procedure, worked in full in How to Design a Single Plate Shear Connection, with the HSS face checks added.

Step 15: Detailing limits of the shear plate at the beam (AISC 360-16 J3.3, J3.4)

Detailing limitLimit (in)Actual (in)DCRResult
Minimum bolt row spacing2.6673.0000.889PASS
Maximum bolt row spacing6.0003.0000.500PASS
Plate minimum vertical edge distance1.2501.5000.833PASS
Plate minimum horizontal edge distance1.3751.5000.917PASS
Beam minimum horizontal edge distance1.2501.5000.833PASS
Minimum connection depth7.7509.0000.861PASS
Maximum connection depth16.0009.0000.563PASS

[math] DCR = \frac{1.375\,in}{1.5\,in} = 0.917 [math]

DCR = 0.917 < 1.0, OK

Step 16: Shear plate bolt group (AISC 360-16 J3.6)

No fillers, so [mathin] h_{f} = 1 [mathin] by J5.2(a). The report uses C = 3 for the three web bolts:

[math] \phi R_{n} = 0.75 \times 68 \times \frac{\pi}{4} (1\,in)^{2} \times (1) \times (3) \times (1) = 120.17\,kip [math]

DCR = 19 kip / 120.17 kip = 0.158 < 1.0, OK

Step 17: Bearing and tear-out on the shear plate (AISC 360-16 J3.10)

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.375 \times 58 + \min(1.2 \times 1.875, 2.4) \times 0.375 \times 58 \times 2 \right] \times \frac{3}{3} = 91.758\,kip [math]

DCR = 19 kip / 91.758 kip = 0.207 < 1.0, OK

Step 18: Bearing and tear-out on the beam web (AISC 360-16 J3.10)

[math] \phi R_{n} = (0.75) \times \min(1.2 \times 1.875, 2.4) \times (0.355\,in) \times (65\,ksi) \times (3) = 116.82\,kip [math]

DCR = 19 kip / 116.82 kip = 0.163 < 1.0, OK

Step 19: Effective strength of the web bolt group (AISC 360-16 J3.6 Commentary)

Per bolt: shear 40.055 kip, plate edge bolt 18.352 kip, plate inner bolt 36.703 kip and beam web 38.939 kip. Bolts 1 and 2 take the inner-bolt value and bolt 3 the edge value:

[math] \Sigma \phi r_{eff} = 2 \times (36.703\,kip) + 18.352\,kip = 91.758\,kip, \qquad \phi R_{n,eff} = 91.758 \times \frac{3}{3} = 91.758\,kip [math]

DCR = 19 kip / 91.758 kip = 0.207 < 1.0, OK

Step 20: Block shear of the shear plate (AISC 360-16 J4.3)

[math] A_{nt} = 0.30469\,in^{2}, \quad A_{gv} = 2.8125\,in^{2}, \quad A_{nv} = 1.6992\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 58 \times 1.6992 + 58 \times 0.30469 \le 0.6 \times 36 \times 2.8125 + 58 \times 0.30469 \right) = 57.604\,kip [math]

DCR = 19 kip / 57.604 kip = 0.330 < 1.0, OK

Step 21: Shear yielding and rupture of the shear plate (AISC 360-16 J4.2)

[math] \phi R_{n\_sy} = 1.0 \times 0.6 \times 36 \times 3.375 = 72.9\,kip, \qquad \phi R_{n\_sr} = 0.75 \times 0.6 \times 58 \times 2.0391 = 53.22\,kip [math]

DCR = 19 kip / 53.22 kip = 0.357 < 1.0, OK

Step 22: Detailing limits of the shear plate at the HSS wall

The workable-flat and slenderness values are the module’s limits for a single plate on an HSS wall.

Detailing limitLimit (in)Actual (in)DCRResult
Maximum fillet weld size per beam clearance0.5000.1880.376PASS
Maximum fillet weld size per HSS workable flat0.8850.1880.212PASS
Maximum HSS wall slenderness b/t33.7165.6020.166PASS

DCR = 0.376 < 1.0, OK

Step 23: Weld from the shear plate to the HSS wall (AISC 360-16 J2.4)

[math] D_{max} = \frac{(0.1875)(58) \le (0.465)(62)}{3.09} = 3.5194, \qquad L_{w} = 2 \left[ 9 – 2 \times 0.1875 \right] = 17.25\,in [math]

[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.1875, \frac{3.5194}{16}\right) \times \left[ 1 + 0.5 \sin^{1.5}(0) \right] \times 17.25 = 72.042\,kip [math]

DCR = 19 kip / 72.042 kip = 0.264 < 1.0, OK

Step 24: HSS wall punching (AISC Manual Eq. 10-7b, page 10-153)

[math] \phi R_{n} = \frac{0.75 \times 62 \times 0.465 \times 9^{2}}{5 \times 2} = 175.14\,kip [math]

DCR = 19 kip / 175.14 kip = 0.108 < 1.0, OK

Summary of design checks

Design checkDemandCapacityDCRResult
Flange: detailing at beam3.625 in gage3.625 in min1.000PASS
Flange bolts in slip59.162 kip62.701 kip0.944PASS
Bearing on flange plate59.162 kip230.34 kip0.257PASS
Bearing on beam flange59.162 kip187.57 kip0.315PASS
Block shear, flange plate59.162 kip168.19 kip0.352PASS
Block shear, beam flange59.162 kip165.34 kip0.358PASS
Flange plate tension59.162 kip141.68 kip0.418PASS
Beam flange tension rupture59.162 kip82.726 kip0.715PASS
Beam flexural rupture at holes59.162 kip204.13 kip0.290PASS
Flange plate compression59.162 kip219.38 kip0.270PASS
Flange: detailing at HSS face0.5 in weld0.5 in max1.000PASS
Flange plate weld to HSS59.162 kip63.144 kip0.937PASS
Flange plate local yielding59.162 kip102.71 kip0.576PASS
HSS sidewall local yielding59.162 kip197.04 kip0.300PASS
Shear plate: detailing at beam1.375 in min1.5 in edge0.917PASS
Shear plate bolt group19 kip120.17 kip0.158PASS
Bearing on shear plate19 kip91.758 kip0.207PASS
Bearing on beam web19 kip116.82 kip0.163PASS
Effective web bolt group strength19 kip91.758 kip0.207PASS
Block shear, shear plate19 kip57.604 kip0.330PASS
Shear yielding and rupture, shear plate19 kip53.22 kip0.357PASS
Shear plate: detailing at HSS wall0.188 in weld0.5 in max0.376PASS
Shear plate weld to HSS19 kip72.042 kip0.264PASS
HSS wall punching19 kip175.14 kip0.108PASS

The connection passes every check. The two ratios at 1.000 are detailing limits that the layout meets exactly. Of the strength checks, the flange bolts in slip govern at 0.944, followed closely by the flange plate weld to the HSS face at 0.937. The weld is limited by the HSS: only 2.883 in of the 6.5 in plate counts as effective width, and the weld length is capped at the 2.875 in workable flat of the 4 in face.

What to change if a check fails

  • Flange bolts in slip: add bolts along the beam, use a larger bolt, or a Class B faying surface. A deeper beam lowers the flange force for the same moment.
  • Flange plate weld to the HSS: a thicker HSS wall raises Be, since Be grows with the square of the wall thickness, and a wider tube face gives a longer workable flat. A thicker flange plate lowers Be, so do not thicken the plate to fix this check.
  • Flange plate local yielding or HSS sidewall yielding: use a thicker-walled tube.
  • Beam flange tension rupture or flexural rupture: reduce the holes in the flange or use a heavier beam.
  • Block shear or plate tension: increase the edge distances, the bolt spacing or the plate thickness.
  • Shear plate checks: as for a shear tab, add a bolt row or make the plate deeper.

Auto Design is available for the flange plate moment connection to an HSS column. It changes the bolts, plates and welds until every check passes, and keeps your members and loads as entered. See the Auto Design page for the preferences it works to.

Frequently asked questions

How is this different from a flange plate connection to a W-shape column?

The beam side checks, Steps 1 to 10, are the same as in How to Design a Flange Plate Moment Connection. The difference is at the column. On a W-shape column the plates weld to a thick flange backed by the column web. An HSS face is a thin wall between the corners, so the flange plate is reduced to an effective width for the weld and for plate local yielding, and the tube sidewalls are checked for local yielding.

Why is the 6.5 in flange plate wider than the 4 in HSS face?

The plate is sized to bolt to the 7.5 in beam flange at a 3.625 in gage, which needs more width than the tube face has. The report allows a plate wider than the face, but only the 4 in over the face counts when the force goes into the HSS.

What is the effective width Be?

Eq. K1-1 reduces a plate welded across an HSS face to the width that is effective in carrying load into the wall. It depends on the wall slenderness b/t and on the ratio of wall to plate strength and thickness. Here Be = 2.883 in of the 4 in effective plate width.

Why is the flange force 59.162 kip?

The 38 kip-ft moment is divided by the distance between flange centers, 17.43 in, giving 26.162 kip, and half of the 66 kip axial force is added to each flange. The report uses this one flange force for every check in the flange plate section.

Does this example follow the AISC 15th or 16th edition Manual?

It follows AISC 360-16 with the AISC Manual 15th Edition and AISC Design Guide 24 for the HSS plate local yielding factor. Clause and page references move in the 16th Edition Manual and AISC 360-22, so check them against the edition your project uses.

Design a flange plate moment connection to an HSS column for free

Every number on this page comes from one solve. Pick the flange plate moment connection to an HSS column, enter your beam, tube, plates, bolts and loads, and see each of these checks in your browser. There is nothing to install.

The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every capacity and DCR, for AISC 360-22 and AISC 360-16 (LRFD and ASD) and AS 4100:2020. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.

References

Harold Munalem, Product Manager for SkyCiv Connection Design

Harold Munalem
Product Manager, Connection Design
10+ years in steel connection design
LinkedIn

How can we help?

×

Updated November 24, 2026

Still stuck? Contact us

Go to Top