To design an apex end plate connection to AS 4100, you treat the ridge of a portal frame as a splice in a flexural member. Each sloping rafter is welded to an end plate cut square to the ridge line, and the two plates are bolted face to face. Because the rafters slope, the vertical shear and the axial force in the rafters both have a part along the plate and a part across it. Those parts change the force on the flange welds, the bolts in tension and the bolts in shear. Clause 9.1.4 also sets minimum design actions for the splice, and at a lightly loaded apex the minimums are often larger than the analysis results.
This page works through one example from start to finish: two 410 UB 53.7 rafters of Grade 300 at a 15° slope, joined by two stiffened 25 mm Grade 250 end plates with eight M24 8.8/TB bolts in the four bolt extended stiffened (4ES) form, for a design bending moment of 121 kNm, a design shear of 22 kN and a design axial compression of 16 kN, designed to AS 4100:2020. Every equation is written out with its numbers, in the same order as the calculation report that the SkyCiv Connection Design module produces for it. The scope and conventions of the AS 4100 module are on the design of steel connections using AS 4100:2020 page.
What is an apex end plate connection?
An apex end plate connection joins the two rafters of a pitched portal frame at the ridge. Each rafter end is cut to the roof slope and fillet welded all round to an end plate. The two plates meet on the vertical centreline of the frame and are bolted together, so the frame can be shipped in pieces and bolted up on site. The plates are extended past the bottom flange, which is the tension flange under the gravity moment at the ridge, so a bolt row can sit outside it. Here they are also extended past the top flange, so the joint can take a moment in either direction.
The rafter meets its end plate at 90° minus the slope on one side of each flange and 90° plus the slope on the other. The flange fillet welds are therefore skewed fillets: the module sizes an equivalent straight fillet and gives the leg sizes that keep the same throat on the acute and obtuse sides. In this example the extensions are stiffened with triangular plates on the web line, which makes the plate stronger in bending. You can also try it in the beam splice calculator.

Elevation of the example apex, with the design actions as entered. Each extension carries a 10 mm stiffener on the web line.

Section A-A. The 4ES form has one bolt row 65 mm outside each flange and one 65 mm inside it, with the stiffener between the outer bolts.

The same apex in SkyCiv Connection Design, with the end plate selected on the Assembly tab.
Apex end plate connection design: the steps at a glance
First find the design actions, not less than the Clause 9.1.4 minimums for a splice, and resolve them along and across the end plate. Then:
- Check the connection detailing limits: gauge, pitch, edge distances, bolt clearances at the sloping flange, plate width and minimum weld sizes.
- Check the beam flange welds, with the flange force from the moment, the axial compression and the shear.
- Check the beam web welds on the tension side for the yield capacity of the web.
- Check the beam web welds on the compression side for the shear along the plate.
- Check the bolts at the tension flange for the design moment.
- Check the bolt group in shear.
- Check the bolt group in bearing on the end plates.
- Check the end plate in bending, by yield lines.
- Check the stiffener welds to the end plate.
- Check the stiffener welds to the beam flange.
Design inputs for this example
The design code is AS 4100:2020, with section properties from the Australian section database. The yield strength of each part follows its grade and thickness: the 10.9 mm rafter flange gives 320 MPa for the Grade 300 section, the 25 mm Grade 250 end plate gives 250 MPa and the 10 mm Grade 250 stiffener gives 260 MPa. In the program the loads are entered as Fx (axial), Fy (shear) and Mz (moment), as for every code; the 16 kN axial load is entered as compression.
| Item | Symbol | Value |
|---|---|---|
| Design bending moment (load entered as Mz) | [mathin] M_{x}^{*} [mathin] | 121 kNm |
| Design shear (load entered as Fy) | [mathin] V^{*} [mathin] | 22 kN |
| Design axial compression (load entered as Fx) | [mathin] N_{c}^{*} [mathin] | 16 kN |
| Rafters, both sides of the apex | 410 UB 53.7, AS/NZS 3679.1 Gr.300 | |
| Rafter slope at the end plate | [mathin] \theta [mathin] | 15° |
| Beam depth / web thickness | [mathin] d_{bm},\ t_{wb} [mathin] | 403 mm / 7.6 mm |
| Beam flange width / thickness | [mathin] b_{fb},\ t_{fb} [mathin] | 178 mm / 10.9 mm |
| Beam root radius | [mathin] r_{b} [mathin] | 11.4 mm |
| Beam area / plastic section modulus | [mathin] A_{bm},\ S_{x} [mathin] | 6890 mm² / 1.06 x 10⁶ mm³ |
| Beam yield / tensile strength | [mathin] f_{yb},\ f_{ub} [mathin] | 320 MPa / 440 MPa |
| Elastic modulus | [mathin] E [mathin] | 200000 MPa |
| Item | Symbol | Value |
|---|---|---|
| End plates (two, face to face) | PL 25 x 230 x 637.22, AS/NZS 3678 Gr.250 | |
| End plate thickness / width / depth | [mathin] t_{i},\ b_{i},\ d_{i} [mathin] | 25 mm / 230 mm / 637.22 mm |
| End plate yield / tensile strength | [mathin] f_{yi},\ f_{ui} [mathin] | 250 MPa / 410 MPa |
| End plate stiffeners | 10 mm Gr.250, 110 mm high x 185 mm long, 17 mm clip | |
| Stiffener thickness / yield strength | [mathin] t_{s},\ f_{ys} [mathin] | 10 mm / 260 MPa |
| Bolts | 8 x M24 8.8/TB, threads included in the shear plane | |
| Bolt diameter / minimum tensile strength | [mathin] d_{f},\ f_{uf} [mathin] | 24 mm / 830 MPa |
| Bolt tensile stress area / core area | [mathin] A_{s},\ A_{c} [mathin] | 353 mm² / 324 mm² |
| Holes in the end plates | [mathin] d_{h} [mathin] | Nominal, 26 mm |
| Beam flange to end plate welds | 12 mm fillet equivalent: 11 mm acute side, 14 mm obtuse side, E49XX, SP | |
| Beam web to end plate welds | 10 mm fillet both sides, E49XX, SP | |
| Stiffener welds | 8 mm to the end plate, 6 mm to the beam flange, both sides | |
| Weld metal strength | [mathin] f_{uw} [mathin] | 490 MPa |
| Geometry | Symbol | Value |
|---|---|---|
| End plate form | 4ES, four bolt extended, stiffened | |
| Bolt rows outside each flange / between the flanges | [mathin] n_{po},\ n_{p} [mathin] | 1 / 2 |
| Bolt columns | [mathin] n_{g} [mathin] | 2 |
| Bolt gauge | [mathin] s_{g} [mathin] | 140 mm |
| Bolt row to the beam flange face | [mathin] s_{po} [mathin] | 65 mm |
| Vertical edge distance on end plate | [mathin] a_{e} [mathin] | 45.002 mm |
| Horizontal edge distance on end plate | [mathin] l_{eh\_ep} [mathin] | 45 mm |
Design actions (AS 4100 Clause 9.1.4)
The design shear is not taken less than the larger of 0.15 times the design shear capacity of the uncoped beam (Clause 5.11.2) and 40 kN:
[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (320\ \text{MPa}) \times (403\ \text{mm}) \times (7.6\ \text{mm}) = 529.25\ \text{kN} [math]
[math] V^{*}_{min} = \max\left( 0.15\, \phi V_{vo},\ 40\ \text{kN} \right) = \max\left( 0.15 \times (529.25\ \text{kN}),\ 40\ \text{kN} \right) = 79.388\ \text{kN} [math]
[math] V^{*} = \max\left( V^{*},\ V^{*}_{min} \right) = \max\left( 22\ \text{kN},\ 79.388\ \text{kN} \right) = 79.388\ \text{kN} [math]
The end plates are not taken as prepared for full contact, so under Clause 9.1.4(b)(v) the splice is designed for at least 0.3 times the design capacity in compression, taken as the section capacity [mathin] \phi A_{bm} f_{yb} [mathin]:
[math] N_{c}^{*} = \max\left( N_{c}^{*},\ 0.3\, \phi\, A_{bm}\, f_{yb} \right) = \max\left( 16\ \text{kN},\ 0.3 \times (0.9) \times (6890\ \text{mm}^{2}) \times (320\ \text{MPa}) \right) = 595.3\ \text{kN} [math]
The apex joins the two rafters in line, so under Clause 9.1.4(b)(vi) it is also a splice in a flexural member, and the design bending moment is not taken less than 0.3 times the design section moment capacity:
[math] M^{*} = \max\left( M_{x}^{*},\ 0.3\, \phi\, f_{yb}\, S_{x} \right) = \max\left( 121\ \text{kNm},\ 0.3 \times (0.9) \times (320\ \text{MPa}) \times (1.06 \times 10^{6}\ \text{mm}^{3}) \right) = 121\ \text{kNm} [math]
Over the lever arm between the flange centres, the moment gives the flange force:
[math] N^{*}_{tm} = \frac{M^{*}}{d_{bm} – t_{fb}} = \frac{121\ \text{kNm}}{(403\ \text{mm}) – (10.9\ \text{mm})} = 308.59\ \text{kN} [math]
Both minimums govern here: the shear goes from 22 kN to 79.388 kN and the axial compression from 16 kN to 595.3 kN. The 121 kNm moment is above its minimum and is used as entered.
Step 1: Connection detailing limitations (AS 4100 Clauses 9.5, 9.6.3.2)
The bolt layout has to be buildable and match the assumptions behind the capacity equations. At a sloping flange the bolt next to the flange also needs room for its length and its head, measured square to the plate, which is why there are two flange to bolt row limits.
The report lists each limit next to the value it is compared with, without a derivation, so the limits below are the software’s limits for this connection. Several match AS 4100 directly: the 60 mm minimum gauge and pitch is [mathin] 2.5\, d_{f} = 2.5 \times 24\ \text{mm} [mathin] (Clause 9.5.1), the 42 mm minimum edge distance is [mathin] 1.75\, d_{f} [mathin] (Clause 9.5.2, Table 9.5.2), the 150 mm maximum edge distance is the Clause 9.5.3 cap, and the minimum fillet weld sizes follow Table 9.6.3.2 for the thicker part joined: 6 mm at the 25 mm end plate and 5 mm for the stiffener to the 10.9 mm flange.
| Detailing limit | Limit (mm) | Actual (mm) | DCR | Result |
|---|---|---|---|---|
| Minimum Bolt Gauge | 60.000 | 140.000 | 0.429 | PASS |
| Maximum Bolt Gauge | 178.000 | 140.000 | 0.787 | PASS |
| Minimum Bolt Pitch across the Tension Flange | 60.000 | 141.285 | 0.425 | PASS |
| Minimum Vertical Edge Distance on End Plate | 42.000 | 45.002 | 0.933 | PASS |
| Minimum Horizontal Edge Distance on End Plate | 42.000 | 45.000 | 0.933 | PASS |
| Maximum Edge Distance | 150.000 | 45.002 | 0.300 | PASS |
| Minimum Bolt Gauge for Wrench Clearance | 77.600 | 140.000 | 0.554 | PASS |
| Minimum Flange to Bolt Row Distance | 39.000 | 65.000 | 0.600 | PASS |
| Minimum Flange to Bolt Row Distance for the Bolt Length at a Sloping Flange | 51.545 | 65.000 | 0.793 | PASS |
| Minimum End Plate Width | 198.000 | 230.000 | 0.861 | PASS |
| Minimum Fillet Weld Size at Beam Flange to End Plate (Acute Side) | 6.000 | 11.000 | 0.545 | PASS |
| Minimum Fillet Weld Size at Beam Web to End Plate | 6.000 | 10.000 | 0.600 | PASS |
| Minimum Fillet Weld Size at End Plate Stiffener to End Plate | 6.000 | 8.000 | 0.750 | PASS |
| Minimum Fillet Weld Size at End Plate Stiffener to Beam Flange | 5.000 | 6.000 | 0.833 | PASS |
For a minimum limit the ratio is limit over actual, and for a maximum it is actual over limit. The governing rows are the vertical and horizontal edge distances on the end plate:
[math] DCR = \frac{42\ \text{mm}}{45\ \text{mm}} = 0.933 [math]
DCR = 0.933 ≤ 1.0, OK
Step 2: Design capacity of the beam flange welds (AS 4100 Clauses 9.6.3.1, 9.6.3.4, 9.6.3.10)
Design force on the flange welds
The flange welds carry the flange force from the moment, half the axial compression, and the flange share of the shear component that acts across the plate. With [mathin] \sin\theta = -0.25882 [mathin] for the 15° slope as the report signs it:
[math] N^{*}_{fw} = N^{*}_{tm} + 0.5\, N_{c}^{*} + 0.5\, V^{*} \left| \sin\theta \right| [math]
[math] N^{*}_{fw} = (308.59\ \text{kN}) + 0.5 \times (595.3\ \text{kN}) + 0.5 \times (79.388\ \text{kN}) \times \left| -0.25882 \right| = 616.52\ \text{kN} [math]
Half of the 595.3 kN minimum compression goes into this force, so it is close to half of the total.
Skewed fillet legs
The rafter meets the end plate at the slope, so on each flange one fillet is on the acute side of the joint (included angle 90° – θ) and the other on the obtuse side (90° + θ), as in Figure 9.6.3.1(d) and (e). Each is sized to give the same throat as a 12 mm equal leg straight fillet:
[math] t_{w,a} = \frac{t_{wf} \cos 45^{\circ}}{\cos\left( \frac{90^{\circ} – \theta}{2} \right)} = \frac{(12\ \text{mm}) \cos 45^{\circ}}{\cos\left( \frac{90^{\circ} – 15^{\circ}}{2} \right)} = 10.695\ \text{mm} [math]
[math] t_{w,o} = \frac{t_{wf} \cos 45^{\circ}}{\cos\left( \frac{90^{\circ} + \theta}{2} \right)} = \frac{(12\ \text{mm}) \cos 45^{\circ}}{\cos\left( \frac{90^{\circ} + 15^{\circ}}{2} \right)} = 13.939\ \text{mm} [math]
Rounded up to a whole millimetre, the specified legs are 11 mm on the acute side and 14 mm on the obtuse side (Clause 9.6.3.1).
Weld capacity
The welds are Structural Purpose (SP), so the capacity factor is 0.8 from Table 3.4. The capacity per unit length is that of the 12 mm straight fillet:
[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{wf} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (12\ \text{mm}) = 1.9957\ \text{kN/mm} [math]
[math] L_{wf} = 2\, b_{fb} – t_{wb} – 2\, r_{b} = 2 \times (178\ \text{mm}) – (7.6\ \text{mm}) – 2 \times (11.4\ \text{mm}) = 325.6\ \text{mm} [math]
[math] \phi N_{w} = \phi v_{w}\, L_{wf} = (1.9957\ \text{kN/mm}) \times (325.6\ \text{mm}) = 649.81\ \text{kN} [math]
[math] N^{*}_{fw} = 616.52\ \text{kN} \le \phi N_{w} = 649.81\ \text{kN} [math]
DCR = 616.52 kN / 649.81 kN = 0.949 ≤ 1.0, OK
This is the governing strength check of the apex.
Step 3: Beam web welds in tension (AS 4100 Clauses 7.2, 9.6.3.10)
The web welds on the tension side of the neutral axis are designed to develop the design yield capacity of the web. The web is cut on the slope, so its weld length is the square length divided by [mathin] \cos\theta = 0.96593 [mathin]:
[math] L_{wt} = \frac{0.5\, d_{bm} – t_{fb} – r_{b}}{\cos\theta} = \frac{0.5 \times (403\ \text{mm}) – (10.9\ \text{mm}) – (11.4\ \text{mm})}{0.96593} = 185.52\ \text{mm} [math]
[math] \phi N_{wt} = \phi\, f_{ywb}\, t_{wb}\, L_{wt} = (0.9) \times (320\ \text{MPa}) \times (7.6\ \text{mm}) \times (185.52\ \text{mm}) = 406.07\ \text{kN} [math]
[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{ww} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (10\ \text{mm}) = 1.6631\ \text{kN/mm} [math]
[math] \phi V_{wt} = 2\, \phi v_{w}\, L_{wt} = 2 \times (1.6631\ \text{kN/mm}) \times (185.52\ \text{mm}) = 617.09\ \text{kN} [math]
[math] \phi N_{wt} = 406.07\ \text{kN} \le \phi V_{wt} = 617.09\ \text{kN} [math]
DCR = 406.07 kN / 617.09 kN = 0.658 ≤ 1.0, OK
Step 4: Beam web welds in shear (AS 4100 Clause 9.6.3.10)
Only the component of the shear along the end plate is taken by the web welds on the compression side:
[math] V^{*}_{vw} = V^{*} \cos\theta = (79.388\ \text{kN}) \times (0.96593) = 76.683\ \text{kN} [math]
[math] L_{wc} = \frac{0.5\, d_{bm} – t_{fb} – r_{b}}{\cos\theta} = 185.52\ \text{mm} [math]
[math] \phi V_{wc} = 2\, \phi v_{w}\, L_{wc} = 2 \times (1.6631\ \text{kN/mm}) \times (185.52\ \text{mm}) = 617.09\ \text{kN} [math]
[math] V^{*}_{vw} = 76.683\ \text{kN} \le \phi V_{wc} = 617.09\ \text{kN} [math]
DCR = 76.683 kN / 617.09 kN = 0.124 ≤ 1.0, OK
Step 5: Design capacity of the bolts at the tension flange (AS 4100 Clauses 9.1.8, 9.2.2.2, 9.3.2)
The shear component across the plate adds a tension flange force, which the module takes as a moment on the bolts:
[math] N^{*}_{fr} = 0.5\, V^{*} \left| \sin\theta \right| = 0.5 \times (79.388\ \text{kN}) \times \left| -0.25882 \right| = 10.274\ \text{kN} [math]
In the 4ES form two bolt rows of two bolts take the tension. Their lever arms about the centre of the compression flange are:
[math] \Sigma d_{i} = d_{10} + d_{11} = (476.57\ \text{mm}) + (335.29\ \text{mm}) = 811.86\ \text{mm} [math]
[math] \phi N_{tf} = \phi\, A_{s}\, f_{uf} = (0.8) \times (353\ \text{mm}^{2}) \times (830\ \text{MPa}) = 234.39\ \text{kN} [math]
The end plates are made thick enough to keep the bolts free of prying (Clause 9.1.8, checked in Step 8), so every tension bolt can reach [mathin] \phi N_{tf} [mathin]:
[math] \phi M_{bt} = 2\, \phi N_{tf}\, \Sigma d_{i} = 2 \times (234.39\ \text{kN}) \times (811.86\ \text{mm}) = 380.59\ \text{kNm} [math]
[math] M^{*}_{axial} = N^{*}_{fr} \left( d_{bm} – t_{fb} \right) = (10.274\ \text{kN}) \times \left( (403\ \text{mm}) – (10.9\ \text{mm}) \right) = 4.0283\ \text{kNm} [math]
The design moment is taken not less than four times this moment, and the moment itself is added on top:
[math] M^{*}_{bt} = \max\left( M^{*},\ 4\, M^{*}_{axial} \right) + M^{*}_{axial} = \max\left( 121\ \text{kNm},\ 4 \times (4.0283\ \text{kNm}) \right) + (4.0283\ \text{kNm}) = 125.03\ \text{kNm} [math]
[math] M^{*}_{bt} = 125.03\ \text{kNm} \le \phi M_{bt} = 380.59\ \text{kNm} [math]
DCR = 125.03 kNm / 380.59 kNm = 0.329 ≤ 1.0, OK
Step 6: Design capacity of the bolt group in shear (AS 4100 Clause 9.2.2.1)
The shear on the bolts is the force along the plate: the shear component along it plus the axial compression component along it. With the 595.3 kN minimum compression, the second term is the larger one:
[math] V^{*}_{v} = V^{*} \cos\theta + N_{c}^{*} \left| \sin\theta \right| = (79.388\ \text{kN}) \times (0.96593) + (595.3\ \text{kN}) \times \left| -0.25882 \right| = 230.76\ \text{kN} [math]
It is taken by the four bolts on the compression side of the neutral axis, [mathin] n_{cw} = 4 [mathin]. The threads are in the shear plane, so the core area is used, with [mathin] k_{r} = k_{rd} = 1.0 [mathin]:
[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, A_{c} = (0.8) \times 0.62 \times (830\ \text{MPa}) \times (324\ \text{mm}^{2}) = 133.38\ \text{kN} [math]
[math] \phi V_{fb} = n_{cw}\, \phi V_{f} = (4) \times (133.38\ \text{kN}) = 533.54\ \text{kN} [math]
[math] V^{*}_{v} = 230.76\ \text{kN} \le \phi V_{fb} = 533.54\ \text{kN} [math]
DCR = 230.76 kN / 533.54 kN = 0.433 ≤ 1.0, OK
Step 7: Bolt group in bearing on the end plates (AS 4100 Clause 9.2.2.4)
Each shear bolt bears on its hole in the 25 mm end plate. With the 26 mm hole (Clause 14.3.2):
[math] a_{e1} = a_{e} – \frac{d_{h}}{2} + \frac{d_{f}}{2} = (45.002\ \text{mm}) – \frac{26\ \text{mm}}{2} + \frac{24\ \text{mm}}{2} = 44.002\ \text{mm} [math]
[math] a_{e2} = s_{pv} – d_{h} + \frac{d_{f}}{2} = (141.28\ \text{mm}) – (26\ \text{mm}) + \frac{24\ \text{mm}}{2} = 127.28\ \text{mm} [math]
[math] \phi V_{bi} = \phi \min\left( 3.2\, d_{f}\, t_{i}\, f_{ui},\ a_{e1}\, t_{i}\, f_{ui},\ a_{e2}\, t_{i}\, f_{ui} \right) [math]
[math] \phi V_{bi} = (0.9) \times \min\left( 3.2 \times (24)(25)(410),\ (44.002)(25)(410),\ (127.28)(25)(410) \right) \times 10^{-3} = 405.92\ \text{kN} [math]
[math] \phi V_{b} = n_{cw}\, \phi V_{bi} = (4) \times (405.92\ \text{kN}) = 1623.7\ \text{kN} [math]
[math] V^{*}_{v} = 230.76\ \text{kN} \le \phi V_{b} = 1623.7\ \text{kN} [math]
DCR = 230.76 kN / 1623.7 kN = 0.142 ≤ 1.0, OK
Step 8: Design bending capacity of the end plate (AS 4100 Clauses 9.1.8, 9.3.2)
As for a level splice, the end plate is compared with a required capacity rather than the design moment. To keep the bolts free of prying under Clause 9.1.8, the plate is made at least 1.11 times as strong as the tension bolts or as the beam, whichever is less:
[math] \phi M_{s} = \phi\, f_{yb}\, S_{x} = (0.9) \times (320\ \text{MPa}) \times (1.06 \times 10^{6}\ \text{mm}^{3}) = 305.28\ \text{kNm} [math]
[math] M^{*}_{p} = \min\left( 1.11\, \phi M_{bt},\ 1.11\, \phi M_{s} \right) = \min\left( 1.11 \times (380.59\ \text{kNm}),\ 1.11 \times (305.28\ \text{kNm}) \right) = 338.86\ \text{kNm} [math]
Yield line factor
[math] b_{i,e} = \min\left( b_{i},\ b_{fb} + 25 \right) = \min\left( 230\ \text{mm},\ (178\ \text{mm}) + (25\ \text{mm}) \right) = 203\ \text{mm} [math]
[math] a_{h} = 0.5 \sqrt{b_{i,e}\, s_{g}} = 0.5 \sqrt{(203\ \text{mm}) \times (140\ \text{mm})} = 84.291\ \text{mm} [math]
[math] s_{pi} = \min\left( s_{po},\ a_{h} \right) = \min\left( 65\ \text{mm},\ 84.291\ \text{mm} \right) = 65\ \text{mm} [math]
Here [mathin] a_{e} \le a_{h} [mathin], so the yield lines at the plate end cross the extension (case 1). For the stiffened 4ES form the yield line factor is:
[math] Y_{p} = 0.5\, b_{i,e} \left[ d_{11} \left( \frac{1}{s_{pi}} + \frac{1}{a_{h}} \right) + d_{10} \left( \frac{1}{s_{po}} + \frac{1}{2 a_{h}} \right) \right] + \frac{2}{s_{g}} \left[ d_{11} \left( s_{pi} + a_{h} \right) + d_{10} \left( a_{e} + s_{po} \right) \right] = 3422.4\ \text{mm} [math]
with [mathin] b_{i,e} = 203\ \text{mm} [mathin], [mathin] s_{g} = 140\ \text{mm} [mathin], [mathin] d_{10} = 476.57\ \text{mm} [mathin], [mathin] d_{11} = 335.29\ \text{mm} [mathin], [mathin] s_{pi} = s_{po} = 65\ \text{mm} [mathin], [mathin] a_{h} = 84.291\ \text{mm} [mathin] and [mathin] a_{e} = 45.002\ \text{mm} [mathin].
Plate capacity
[math] \phi M_{pt} = \phi\, f_{yi}\, t_{i}^{2}\, Y_{p} = (0.9) \times (250\ \text{MPa}) \times (25\ \text{mm})^{2} \times (3422.4\ \text{mm}) = 481.28\ \text{kNm} [math]
[math] M^{*}_{p} = 338.86\ \text{kNm} \le \phi M_{pt} = 481.28\ \text{kNm} [math]
DCR = 338.86 kNm / 481.28 kNm = 0.704 ≤ 1.0, OK
The stiffened 4ES plate gives a yield line factor of 3422.4 mm, so a 25 mm plate is enough here.
Step 9: Design capacity of the end plate stiffener welds to the end plate (AS 4100 Clause 9.6.3.10)
The stiffener depth clear of the 17 mm clip, and the minimum stiffener thickness for strength and for local buckling, are computed first:
[math] d_{s} = h_{st} – c_{st} = (110\ \text{mm}) – (17\ \text{mm}) = 93.002\ \text{mm} [math]
[math] t_{s,min1} = t_{wb}\, \frac{f_{ywb}}{f_{ys}} = (7.6\ \text{mm}) \times \frac{320\ \text{MPa}}{260\ \text{MPa}} = 9.3538\ \text{mm} [math]
[math] t_{s,min2} = 1.79\, d_{s} \sqrt{\frac{f_{ys}}{E}} = 1.79 \times (93.002\ \text{mm}) \times \sqrt{\frac{260\ \text{MPa}}{200000\ \text{MPa}}} = 6.0023\ \text{mm} [math]
The 10 mm stiffener is thicker than both. The fillet welds on both sides of the stiffener develop its tension capacity at the end plate:
[math] v^{*}_{s} = \phi\, t_{s}\, f_{ys} = (0.9) \times (10\ \text{mm}) \times (260\ \text{MPa}) = 2.34\ \text{kN/mm} [math]
[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{wsp} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (8\ \text{mm}) = 1.3305\ \text{kN/mm} [math]
[math] 2\, \phi v_{w} = 2 \times (1.3305\ \text{kN/mm}) = 2.661\ \text{kN/mm} [math]
[math] v^{*}_{s} = 2.34\ \text{kN/mm} \le 2\, \phi v_{w} = 2.661\ \text{kN/mm} [math]
DCR = 2.34 kN/mm / 2.661 kN/mm = 0.879 ≤ 1.0, OK
Step 10: Design capacity of the end plate stiffener welds to the beam flange (AS 4100 Clause 9.6.3.10)
The stiffener length clear of the clip, and its minimum length:
[math] b_{s} = L_{st} – c_{st} = (185\ \text{mm}) – (17\ \text{mm}) = 168\ \text{mm} [math]
[math] b_{s,min} = 1.73\, d_{s} = 1.73 \times (93.002\ \text{mm}) = 160.89\ \text{mm} [math]
The 168 mm stiffener is longer than the minimum. Along the beam flange the welds develop the shear capacity of the stiffener, half its tension capacity:
[math] v^{*}_{sb} = \phi\, 0.5\, t_{s}\, f_{ys} = (0.9) \times 0.5 \times (10\ \text{mm}) \times (260\ \text{MPa}) = 1.17\ \text{kN/mm} [math]
[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{wsb} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (6\ \text{mm}) = 0.99787\ \text{kN/mm} [math]
[math] 2\, \phi v_{w} = 2 \times (0.99787\ \text{kN/mm}) = 1.9957\ \text{kN/mm} [math]
[math] v^{*}_{sb} = 1.17\ \text{kN/mm} \le 2\, \phi v_{w} = 1.9957\ \text{kN/mm} [math]
DCR = 1.17 kN/mm / 1.9957 kN/mm = 0.586 ≤ 1.0, OK
Summary of checks
| Design check | Design action effect | Design capacity | DCR | Result |
|---|---|---|---|---|
| Connection detailing limitations | 42 mm | 45 mm | 0.933 | PASS |
| Beam flange welds | 616.516 kN | 649.812 kN | 0.949 | PASS |
| Beam web welds in tension | 406.069 kN | 617.087 kN | 0.658 | PASS |
| Beam web welds in shear | 76.6827 kN | 617.087 kN | 0.124 | PASS |
| Bolts at the tension flange | 125.028 kNm | 380.589 kNm | 0.329 | PASS |
| Bolt group in shear | 230.757 kN | 533.537 kN | 0.433 | PASS |
| Bolt group in bearing on the end plates | 230.757 kN | 1623.67 kN | 0.142 | PASS |
| End plate in bending | 338.861 kNm | 481.279 kNm | 0.704 | PASS |
| End plate stiffener welds to the end plate | 2.34 kN/mm | 2.66098 kN/mm | 0.879 | PASS |
| End plate stiffener welds to the beam flange | 1.17 kN/mm | 1.99574 kN/mm | 0.586 | PASS |
The apex passes every check. Of the strength checks, the beam flange welds govern at 0.949, followed by the stiffener welds to the end plate at 0.879 and the end plate in bending at 0.704. The detailing check is at 0.933, on the 45 mm edge distances against the 42 mm minimum. Most of the flange weld demand comes from the Clause 9.1.4 minimums: the moment alone gives 308.59 kN of the 616.52 kN.
What to change if a check fails
- Detailing limits: move the bolts to the edge distances and gauge in Step 1, widen the end plate, or move the bolt rows further from the sloping flanges.
- Beam flange welds: increase the equivalent fillet size, which raises both skewed legs. The weld length is fixed by the flange.
- Beam web welds: increase the web weld size. The tension side is designed for the web’s yield capacity, so a lower moment does not help.
- Bolts at the tension flange: use a larger bolt or a higher grade, or move the outer row further from the flange.
- Bolt group in shear or bearing: use a larger bolt or increase the edge distance on the end plate. A flatter roof also reduces the share of the axial compression that acts along the plate.
- End plate in bending: use a thicker end plate, or keep the stiffeners. The capacity grows with the square of the thickness.
- Stiffener welds: increase the stiffener weld sizes. A thicker stiffener needs larger welds, because the welds develop the stiffener’s own capacity.
Frequently asked questions
Why is the axial compression 595.3 kN when 16 kN was entered?
The apex end plates are not taken as prepared for full contact, so Clause 9.1.4(b)(v) asks for the splice to be designed for at least 0.3 times the design capacity in compression. The module takes this as the section capacity: 0.3 x 0.9 x 6890 mm² x 320 MPa = 595.3 kN. Half of it goes into the flange weld demand and its component along the plate goes into the bolt shear, so it has a large effect on both checks.
Why is the shear 79.388 kN when 22 kN was entered?
Clause 9.1.4 also sets a minimum design shear for a splice in a flexural member. The program takes the larger of 0.15 times the design shear capacity of the uncoped beam and 40 kN, which for a 410 UB 53.7 is 79.388 kN.
Why are the flange welds 11 mm on one side and 14 mm on the other?
The rafter meets the end plate at 90° minus the 15° slope on one side of each flange and at 90° plus the slope on the other. The module designs the welds as a 12 mm straight fillet and then finds the skewed leg sizes that give the same throat on each side, 10.695 mm and 13.939 mm, rounded up to 11 mm and 14 mm.
Why is the bolt shear larger than the design shear?
The bolts take the force along the end plate. Because the plate is vertical and the rafter slopes at 15°, the axial compression has a component along the plate, 595.3 kN times 0.25882, which adds to the 76.683 kN component of the shear. The total is 230.76 kN.
What does form 4ES mean?
4ES is four bolt extended and stiffened: two bolts in one row outside the flange and two in one row inside it, with a stiffener on the web line of the extension. The stiffener raises the yield line factor of the plate, and its welds are checked in Steps 9 and 10.
Design an apex end plate connection for free
Every number on this page comes from one solve. Pick AS 4100:2020 and the apex end plate, enter your rafters, slope, end plates, bolts and design actions, and see each of these checks in your browser. There is nothing to install.
The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every design capacity and DCR, for AS 4100:2020 shear connections, moment connections and splices. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.
References
- AS 4100:2020, Steel Structures: Clauses 5.11.2, 7.2, 9.1.4, 9.1.8, 9.2.2.1, 9.2.2.2, 9.2.2.4, 9.3.2, 9.5.1, 9.5.2, 9.5.3, 9.6.3.1, 9.6.3.4, 9.6.3.10, 14.3.2; Figure 9.6.3.1; Tables 2.1, 3.4 and 9.6.3.2.
- Design of steel connections using AS 4100:2020
- Loads and load combinations in SkyCiv Connection Design
Harold Munalem
Product Manager, Connection Design
10+ years in steel connection design