To design an extended end plate beam splice to AS 4100, you follow the bending moment and the shear across the joint. Each beam is welded to its own end plate in the shop, and the two plates are bolted face to face on site. The moment becomes a couple of flange forces: the tension flange pulls its end plate away from the other one, the plate bends between the bolts, and the bolts on both sides of that flange carry the tension across the joint. The compression flange pushes the plates together, and the shear is taken by the bolts on the compression side. A splice also has to carry the minimum design actions of Clause 9.1.4, whatever the analysis gives.
This page works through one example from start to finish: two 410 UB 53.7 beams of Grade 300 joined by two 28 mm Grade 250 end plates, with eight M24 8.8/TB bolts in the four bolt extended (4E) form, for a design bending moment of 192 kNm and a design shear of 35 kN, designed to AS 4100:2020. Every equation is written out with its numbers, in the same order as the calculation report that the SkyCiv Connection Design module produces for it. The scope and conventions of the AS 4100 module are on the design of steel connections using AS 4100:2020 page.
What is an extended end plate beam splice?
An extended end plate beam splice joins two lengths of beam end to end with a moment connection. Each beam end is cut square and fillet welded all round to a plate that is wider and deeper than the beam. The plates are then bolted together, so the splice can be made on site with bolts only. "Extended" means the plates project past the beam flanges, so a row of bolts can sit outside the tension flange as well as inside it. That outer row has a longer lever arm and adds a lot to the moment the bolts can carry.
The splice is used where a beam is too long to transport or erect in one piece, or where a frame is split into parts that are bolted up on site. In the AS 4100 module the same card covers the level splice, and the sloped version at the ridge of a portal frame is the Apex End Plate card. You can also try it in the beam splice calculator.
In this example the plates are unstiffened, with one bolt row outside each flange and two rows between the flanges, so there are eight bolts in four rows of two on a 140 mm gauge.

Elevation of the example splice, with the design actions as entered. The flanges and the web are welded to the end plates with 10 mm fillet welds on both sides.

Section A-A. The 4E form has one bolt row 65 mm outside each flange and one 65 mm inside it, with 45 mm edge distances on the plate.

The same splice in SkyCiv Connection Design, with the end plate selected on the Assembly tab.
Extended end plate beam splice design: the steps at a glance
First find the design actions, not less than the Clause 9.1.4 minimums for a splice. Then:
- Check the connection detailing limits: gauge, pitch, edge distances, plate width and minimum weld sizes.
- Check the beam flange welds for the flange force.
- Check the beam web welds on the tension side for the yield capacity of the web.
- Check the beam web welds on the compression side for the design shear.
- Check the bolts at the tension flange for the design moment.
- Check the bolt group in shear.
- Check the bolt group in bearing on the end plates.
- Check the end plate in bending, by yield lines.
- Check the end plate extension in shear yield.
- Check the end plate extension in shear rupture.
Design inputs for this example
The design code is AS 4100:2020, with section properties from the Australian section database. The yield strength of each part follows its grade and thickness: the 10.9 mm beam flange gives 320 MPa for the Grade 300 beam, and the 28 mm Grade 250 end plate gives 250 MPa. In the program the loads are entered as Fy (shear) and Mz (moment), as for every code.
| Item | Symbol | Value |
|---|---|---|
| Design bending moment (load entered as Mz) | [mathin] M_{x}^{*} [mathin] | 192 kNm |
| Design shear (load entered as Fy) | [mathin] V^{*} [mathin] | 35 kN |
| Beams, both sides of the splice | 410 UB 53.7, AS/NZS 3679.1 Gr.300 | |
| Beam depth / web thickness | [mathin] d_{bm},\ t_{wb} [mathin] | 403 mm / 7.6 mm |
| Beam flange width / thickness | [mathin] b_{fb},\ t_{fb} [mathin] | 178 mm / 10.9 mm |
| Beam root radius | [mathin] r_{b} [mathin] | 11.4 mm |
| Beam area / plastic section modulus | [mathin] A_{bm},\ S_{x} [mathin] | 6890 mm² / 1.06 x 10⁶ mm³ |
| Beam yield / tensile strength | [mathin] f_{yb},\ f_{ub} [mathin] | 320 MPa / 440 MPa |
| Elastic modulus | [mathin] E [mathin] | 200000 MPa |
| Item | Symbol | Value |
|---|---|---|
| End plates (two, face to face) | PL 28 x 230 x 623, AS/NZS 3678 Gr.250 | |
| End plate thickness / width / depth | [mathin] t_{i},\ b_{i},\ d_{i} [mathin] | 28 mm / 230 mm / 623 mm |
| End plate yield / tensile strength | [mathin] f_{yi},\ f_{ui} [mathin] | 250 MPa / 410 MPa |
| Bolts | 8 x M24 8.8/TB, threads included in the shear plane | |
| Bolt diameter / minimum tensile strength | [mathin] d_{f},\ f_{uf} [mathin] | 24 mm / 830 MPa |
| Bolt tensile stress area / core area | [mathin] A_{s},\ A_{c} [mathin] | 353 mm² / 324 mm² |
| Holes in the end plates | [mathin] d_{h} [mathin] | Nominal, 26 mm |
| Beam flange to end plate welds | 10 mm fillet both sides, E49XX, SP | |
| Beam web to end plate welds | 10 mm fillet both sides, E49XX, SP | |
| Weld metal strength | [mathin] f_{uw} [mathin] | 490 MPa |
| Geometry | Symbol | Value |
|---|---|---|
| End plate form | 4E, four bolt extended, unstiffened | |
| Bolt rows outside each flange / between the flanges | [mathin] n_{po},\ n_{p} [mathin] | 1 / 2 |
| Bolt columns | [mathin] n_{g} [mathin] | 2 |
| Bolt gauge | [mathin] s_{g} [mathin] | 140 mm |
| Bolt row to the beam flange face | [mathin] s_{po} [mathin] | 65 mm |
| Vertical edge distance on end plate | [mathin] a_{e} [mathin] | 45 mm |
| Horizontal edge distance on end plate | [mathin] l_{eh\_ep} [mathin] | 45 mm |
The end plate depth is the beam depth plus, at each end, the 65 mm to the outer bolt row and the 45 mm edge distance: 403 + 2 x 110 = 623 mm.
Design actions (AS 4100 Clause 9.1.4)
Clause 9.1.4 sets minimum design actions for a splice in a flexural member. The design bending moment is not taken less than 0.3 times the design section moment capacity of the beam:
[math] M^{*} = \max\left( M_{x}^{*},\ 0.3\, \phi\, f_{yb}\, S_{x} \right) = \max\left( (192\ \text{kNm}),\ 0.3 \times (0.9) \times (320\ \text{MPa}) \times (1.06 \times 10^{6}\ \text{mm}^{3}) \right) = 192\ \text{kNm} [math]
The 192 kNm entered is larger than the minimum, so it is used as is. Over the lever arm between the flange centres, it gives the flange force:
[math] N^{*}_{tm} = \frac{M^{*}}{d_{bm} – t_{fb}} = \frac{192\ \text{kNm}}{(403\ \text{mm}) – (10.9\ \text{mm})} = 489.67\ \text{kN} [math]
The design shear is not taken less than the larger of 0.15 times the design shear capacity of the uncoped beam (Clause 5.11.2) and 40 kN:
[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (320\ \text{MPa}) \times (403\ \text{mm}) \times (7.6\ \text{mm}) = 529.25\ \text{kN} [math]
[math] V^{*}_{min} = \max\left( 0.15\, \phi V_{vo},\ 40\ \text{kN} \right) = \max\left( 0.15 \times (529.25\ \text{kN}),\ 40\ \text{kN} \right) = 79.388\ \text{kN} [math]
[math] V^{*} = \max\left( V^{*},\ V^{*}_{min} \right) = \max\left( 35\ \text{kN},\ 79.388\ \text{kN} \right) = 79.388\ \text{kN} [math]
Here the minimum governs, so every shear check below uses 79.388 kN, not the 35 kN entered.
Step 1: Connection detailing limitations (AS 4100 Clauses 9.5, 9.6.3.2)
Before any capacity check, the bolt layout has to be buildable and match the assumptions behind the capacity equations. The bolts need room for a wrench, the edges must be far enough from the holes, and the welds must be big enough for the parts they join.
The report lists each limit next to the value it is compared with, without a derivation, so the limits below are the software’s limits for this connection. Several match AS 4100 directly: the 60 mm minimum gauge and pitch is [mathin] 2.5\, d_{f} = 2.5 \times 24\ \text{mm} [mathin] (Clause 9.5.1), the 42 mm minimum edge distance is [mathin] 1.75\, d_{f} [mathin] (Clause 9.5.2, Table 9.5.2), the 150 mm maximum edge distance is the Clause 9.5.3 cap, and the 6 mm minimum fillet weld is the Table 9.6.3.2 size for the thicker part joined, the 28 mm end plate.
| Detailing limit | Limit (mm) | Actual (mm) | DCR | Result |
|---|---|---|---|---|
| Minimum Bolt Gauge | 60.000 | 140.000 | 0.429 | PASS |
| Maximum Bolt Gauge | 178.000 | 140.000 | 0.787 | PASS |
| Minimum Bolt Pitch across the Tension Flange | 60.000 | 140.900 | 0.426 | PASS |
| Minimum Vertical Edge Distance on End Plate | 42.000 | 45.000 | 0.933 | PASS |
| Minimum Horizontal Edge Distance on End Plate | 42.000 | 45.000 | 0.933 | PASS |
| Maximum Edge Distance | 150.000 | 45.000 | 0.300 | PASS |
| Minimum Bolt Gauge for Wrench Clearance | 77.600 | 140.000 | 0.554 | PASS |
| Minimum Flange to Bolt Row Distance | 35.000 | 65.000 | 0.538 | PASS |
| Minimum End Plate Width | 198.000 | 230.000 | 0.861 | PASS |
| Minimum Fillet Weld Size at Beam Flange to End Plate | 6.000 | 10.000 | 0.600 | PASS |
| Minimum Fillet Weld Size at Beam Web to End Plate | 6.000 | 10.000 | 0.600 | PASS |
For a minimum limit the ratio is limit over actual, and for a maximum it is actual over limit. The governing rows are the vertical and horizontal edge distances on the end plate:
[math] DCR = \frac{42\ \text{mm}}{45\ \text{mm}} = 0.933 [math]
DCR = 0.933 ≤ 1.0, OK
Step 2: Design capacity of the beam flange welds (AS 4100 Clause 9.6.3.10)
The fillet welds round the tension flange carry the whole flange force into the end plate. The design force on them is the flange force from the design moment, [mathin] N^{*}_{fw} = N^{*}_{tm} = 489.67\ \text{kN} [mathin]. The welds are Structural Purpose (SP), so the capacity factor is 0.8 from Table 3.4. The design capacity per unit length of an equal-leg fillet weld:
[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{wf} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (10\ \text{mm}) = 1.6631\ \text{kN/mm} [math]
The welds run across the outside of the flange and along the inside on both sides of the web, stopping at the root radii:
[math] L_{wf} = 2\, b_{fb} – t_{wb} – 2\, r_{b} = 2 \times (178\ \text{mm}) – (7.6\ \text{mm}) – 2 \times (11.4\ \text{mm}) = 325.6\ \text{mm} [math]
[math] \phi N_{w} = \phi v_{w}\, L_{wf} = (1.6631\ \text{kN/mm}) \times (325.6\ \text{mm}) = 541.51\ \text{kN} [math]
[math] N^{*}_{fw} = 489.67\ \text{kN} \le \phi N_{w} = 541.51\ \text{kN} [math]
DCR = 489.67 kN / 541.51 kN = 0.904 ≤ 1.0, OK
This is the governing strength check of the splice.
Step 3: Beam web welds in tension (AS 4100 Clauses 7.2, 9.6.3.10)
The web welds on the tension side of the neutral axis are designed to develop the design yield capacity of the web, not just the share of the moment the web carries. That keeps the welds from being the weak link if the web yields. The weld length on the tension side runs from mid-depth to the root radius:
[math] L_{wt} = 0.5\, d_{bm} – t_{fb} – r_{b} = 0.5 \times (403\ \text{mm}) – (10.9\ \text{mm}) – (11.4\ \text{mm}) = 179.2\ \text{mm} [math]
[math] \phi N_{wt} = \phi\, f_{ywb}\, t_{wb}\, L_{wt} = (0.9) \times (320\ \text{MPa}) \times (7.6\ \text{mm}) \times (179.2\ \text{mm}) = 392.23\ \text{kN} [math]
The 10 mm web welds have the same capacity per unit length as the flange welds, 1.6631 kN/mm, on both sides of the web:
[math] \phi V_{wt} = 2\, \phi v_{w}\, L_{wt} = 2 \times (1.6631\ \text{kN/mm}) \times (179.2\ \text{mm}) = 596.06\ \text{kN} [math]
[math] \phi N_{wt} = 392.23\ \text{kN} \le \phi V_{wt} = 596.06\ \text{kN} [math]
DCR = 392.23 kN / 596.06 kN = 0.658 ≤ 1.0, OK
Step 4: Beam web welds in shear (AS 4100 Clause 9.6.3.10)
The design shear is taken by the web welds on the compression side of the neutral axis, [mathin] V^{*}_{vw} = V^{*} = 79.388\ \text{kN} [mathin]. Their length is the same as on the tension side:
[math] L_{wc} = 0.5\, d_{bm} – t_{fb} – r_{b} = 0.5 \times (403\ \text{mm}) – (10.9\ \text{mm}) – (11.4\ \text{mm}) = 179.2\ \text{mm} [math]
[math] \phi V_{wc} = 2\, \phi v_{w}\, L_{wc} = 2 \times (1.6631\ \text{kN/mm}) \times (179.2\ \text{mm}) = 596.06\ \text{kN} [math]
[math] V^{*}_{vw} = 79.388\ \text{kN} \le \phi V_{wc} = 596.06\ \text{kN} [math]
DCR = 79.388 kN / 596.06 kN = 0.133 ≤ 1.0, OK
Step 5: Design capacity of the bolts at the tension flange (AS 4100 Clauses 9.2.2.2, 9.3.2)
In the 4E form the two bolt rows next to the tension flange, one outside and one inside, take the tension, two bolts per row. The bolts rotate about the centre of the compression flange, so each row’s lever arm is measured from there:
[math] d_{10} = 462.55\ \text{mm}, \qquad d_{11} = 321.65\ \text{mm} [math]
[math] \Sigma d_{i} = d_{10} + d_{11} = (462.55\ \text{mm}) + (321.65\ \text{mm}) = 784.2\ \text{mm} [math]
The design capacity of one bolt in tension, with a capacity factor of 0.8:
[math] \phi N_{tf} = \phi\, A_{s}\, f_{uf} = (0.8) \times (353\ \text{mm}^{2}) \times (830\ \text{MPa}) = 234.39\ \text{kN} [math]
The end plates are made thick enough to keep the bolts free of prying (Clause 9.1.8, checked in Step 8), so every tension bolt can reach [mathin] \phi N_{tf} [mathin]:
[math] \phi M_{bt} = 2\, \phi N_{tf}\, \Sigma d_{i} = 2 \times (234.39\ \text{kN}) \times (784.2\ \text{mm}) = 367.62\ \text{kNm} [math]
[math] M^{*} = 192\ \text{kNm} \le \phi M_{bt} = 367.62\ \text{kNm} [math]
DCR = 192 kNm / 367.62 kNm = 0.522 ≤ 1.0, OK
Step 6: Design capacity of the bolt group in shear (AS 4100 Clause 9.2.2.1)
The design shear is taken by the bolts on the compression side of the neutral axis, [mathin] n_{cw} = 4 [mathin], because the tension bolts are already working in tension. The threads are in the shear plane, so the core area is used, and [mathin] k_{r} = k_{rd} = 1.0 [mathin]:
[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, A_{c} = (0.8) \times 0.62 \times (830\ \text{MPa}) \times (324\ \text{mm}^{2}) = 133.38\ \text{kN} [math]
[math] \phi V_{fb} = n_{cw}\, \phi V_{f} = (4) \times (133.38\ \text{kN}) = 533.54\ \text{kN} [math]
[math] V^{*}_{v} = 79.388\ \text{kN} \le \phi V_{fb} = 533.54\ \text{kN} [math]
DCR = 79.388 kN / 533.54 kN = 0.149 ≤ 1.0, OK
Step 7: Bolt group in bearing on the end plates (AS 4100 Clause 9.2.2.4)
Each shear bolt bears on its hole in the end plate. The ply can crush at the hole, capped at [mathin] 3.2\, d_{f}\, t_{i}\, f_{ui} [mathin], or tear out to the plate edge or to the next hole. With [mathin] d_{h} = 26\ \text{mm} [mathin]:
[math] a_{e1} = a_{e} – \frac{d_{h}}{2} + \frac{d_{f}}{2} = (45\ \text{mm}) – \frac{26\ \text{mm}}{2} + \frac{24\ \text{mm}}{2} = 44\ \text{mm} [math]
The least pitch from a shear bolt row to the next row is 140.9 mm, the distance across the flange from the outer row to the inner row:
[math] a_{e2} = s_{pv} – d_{h} + \frac{d_{f}}{2} = (140.9\ \text{mm}) – (26\ \text{mm}) + \frac{24\ \text{mm}}{2} = 126.9\ \text{mm} [math]
The capacity factor for a ply in bearing is 0.9:
[math] \phi V_{bi} = \phi \min\left( 3.2\, d_{f}\, t_{i}\, f_{ui},\ a_{e1}\, t_{i}\, f_{ui},\ a_{e2}\, t_{i}\, f_{ui} \right) [math]
[math] \phi V_{bi} = (0.9) \times \min\left( 3.2 \times (24)(28)(410),\ (44)(28)(410),\ (126.9)(28)(410) \right) \times 10^{-3} = 454.61\ \text{kN} [math]
[math] \phi V_{b} = n_{cw}\, \phi V_{bi} = (4) \times (454.61\ \text{kN}) = 1818.4\ \text{kN} [math]
[math] V^{*}_{v} = 79.388\ \text{kN} \le \phi V_{b} = 1818.4\ \text{kN} [math]
DCR = 79.388 kN / 1818.4 kN = 0.044 ≤ 1.0, OK
The edge distance term governs each bolt, but a 28 mm plate leaves bearing far from critical.
Step 8: Design bending capacity of the end plate (AS 4100 Clauses 9.1.8, 9.3.2)
The end plate bends between the tension flange, the web and the bolts. Its capacity is found from a yield line pattern, and it is compared with a required capacity rather than with the design moment: Clause 9.1.8 asks for prying to be allowed for, and the module removes it by making the plate at least 1.11 times as strong as the tension bolts or as the beam, whichever is less. A plate that strong stays thick enough that the bolts carry only their direct tension.
The design section moment capacity of the beam:
[math] \phi M_{s} = \phi\, f_{yb}\, S_{x} = (0.9) \times (320\ \text{MPa}) \times (1.06 \times 10^{6}\ \text{mm}^{3}) = 305.28\ \text{kNm} [math]
[math] M^{*}_{p} = \min\left( 1.11\, \phi M_{bt},\ 1.11\, \phi M_{s} \right) = \min\left( 1.11 \times (367.62\ \text{kNm}),\ 1.11 \times (305.28\ \text{kNm}) \right) = 338.86\ \text{kNm} [math]
Yield line factor
The width of plate that takes part in the yield lines is limited to the flange width plus 25 mm:
[math] b_{i,e} = \min\left( b_{i},\ b_{fb} + 25 \right) = \min\left( 230\ \text{mm},\ (178\ \text{mm}) + (25\ \text{mm}) \right) = 203\ \text{mm} [math]
[math] a_{h} = 0.5 \sqrt{b_{i,e}\, s_{g}} = 0.5 \sqrt{(203\ \text{mm}) \times (140\ \text{mm})} = 84.291\ \text{mm} [math]
[math] s_{pi} = \min\left( s_{po},\ a_{h} \right) = \min\left( 65\ \text{mm},\ 84.291\ \text{mm} \right) = 65\ \text{mm} [math]
For the 4E form the yield line factor is:
[math] Y_{p} = 0.5\, b_{i,e} \left[ d_{11} \left( \frac{1}{s_{pi}} + \frac{1}{a_{h}} \right) + \frac{d_{10}}{s_{po}} – 0.5 \right] + \frac{2}{s_{g}}\, d_{11} \left( s_{pi} + a_{h} \right) = 2247.1\ \text{mm} [math]
with [mathin] b_{i,e} = 203\ \text{mm} [mathin], [mathin] s_{g} = 140\ \text{mm} [mathin], [mathin] d_{10} = 462.55\ \text{mm} [mathin], [mathin] d_{11} = 321.65\ \text{mm} [mathin], [mathin] s_{pi} = s_{po} = 65\ \text{mm} [mathin] and [mathin] a_{h} = 84.291\ \text{mm} [mathin].
Plate capacity
[math] \phi M_{pt} = \phi\, f_{yi}\, t_{i}^{2}\, Y_{p} = (0.9) \times (250\ \text{MPa}) \times (28\ \text{mm})^{2} \times (2247.1\ \text{mm}) = 396.39\ \text{kNm} [math]
[math] M^{*}_{p} = 338.86\ \text{kNm} \le \phi M_{pt} = 396.39\ \text{kNm} [math]
DCR = 338.86 kNm / 396.39 kNm = 0.855 ≤ 1.0, OK
Because the requirement is tied to the beam capacity and not to the design moment, this ratio does not change with the load. It is what sets the 28 mm plate thickness.
Step 9: Shear yield of the end plate extension (software check)
The report gives this check without a clause, so it is the software’s check.
The part of the plate outside the tension flange carries the pull of the outer bolt row back to the flange, so it is checked in shear across its full width. The flange force is shared by the two bolt rows at the tension flange, [mathin] n_{bp} = 2 [mathin]:
[math] V^{*}_{p} = \frac{N^{*}_{ft}}{n_{bp}} = \frac{489.67\ \text{kN}}{2} = 244.84\ \text{kN} [math]
[math] \phi V_{pe} = \phi\, 0.5\, f_{yi}\, b_{i}\, t_{i} = (0.9) \times 0.5 \times (250\ \text{MPa}) \times (230\ \text{mm}) \times (28\ \text{mm}) = 724.5\ \text{kN} [math]
[math] V^{*}_{p} = 244.84\ \text{kN} \le \phi V_{pe} = 724.5\ \text{kN} [math]
DCR = 244.84 kN / 724.5 kN = 0.338 ≤ 1.0, OK
Step 10: Shear rupture of the end plate extension (software check, holes to Clause 14.3.2)
This check also has no clause in the report; only the 26 mm hole size is cited, to Clause 14.3.2.
The same section is checked for rupture on its net width, less the two bolt holes:
[math] \phi V_{pu} = \phi\, 0.6\, f_{ui} \left( b_{i} – 2\, d_{h} \right) t_{i} = (0.9) \times 0.6 \times (410\ \text{MPa}) \times \left( (230\ \text{mm}) – 2 \times (26\ \text{mm}) \right) \times (28\ \text{mm}) = 1103.5\ \text{kN} [math]
[math] V^{*}_{p} = 244.84\ \text{kN} \le \phi V_{pu} = 1103.5\ \text{kN} [math]
DCR = 244.84 kN / 1103.5 kN = 0.222 ≤ 1.0, OK
Summary of checks
| Design check | Design action effect | Design capacity | DCR | Result |
|---|---|---|---|---|
| Connection detailing limitations | 42 mm | 45 mm | 0.933 | PASS |
| Beam flange welds | 489.671 kN | 541.51 kN | 0.904 | PASS |
| Beam web welds in tension | 392.233 kN | 596.06 kN | 0.658 | PASS |
| Beam web welds in shear | 79.388 kN | 596.06 kN | 0.133 | PASS |
| Bolts at the tension flange | 192 kNm | 367.62 kNm | 0.522 | PASS |
| Bolt group in shear | 79.388 kN | 533.537 kN | 0.149 | PASS |
| Bolt group in bearing on the end plates | 79.388 kN | 1818.43 kN | 0.044 | PASS |
| End plate in bending | 338.861 kNm | 396.392 kNm | 0.855 | PASS |
| End plate extension, shear yield | 244.835 kN | 724.5 kN | 0.338 | PASS |
| End plate extension, shear rupture | 244.835 kN | 1103.46 kN | 0.222 | PASS |
The splice passes every check. The highest ratio, 0.933, is the detailing check: the 45 mm edge distances on the end plate against the 42 mm minimum for an M24 bolt. Of the strength checks, the beam flange welds govern at 0.904, followed by the end plate in bending at 0.855. The bolts are lightly used in tension (0.522) and in shear (0.149), because the plate was sized to stay thick and the shear is small.
What to change if a check fails
- Detailing limits: move the bolts to the edge distances and gauge in Step 1, or widen the end plate. A thicker end plate also raises the Table 9.6.3.2 minimum weld size.
- Beam flange welds: increase the fillet weld size. The weld length is fixed by the flange, so a larger weld or a stronger electrode is the only change.
- Beam web welds: increase the web weld size. The tension side is designed for the web’s yield capacity, so a lower moment does not help.
- Bolts at the tension flange: use a larger bolt or a higher grade, move the outer row further from the flange, or add bolt rows.
- Bolt group in shear or bearing: use a larger bolt, or increase the edge distance on the end plate.
- End plate in bending: use a thicker end plate. The capacity grows with the square of the thickness, and the required capacity depends on the bolts and the beam, not on the load.
- End plate extension: use a thicker or wider end plate.
Frequently asked questions
Why is the shear 79.388 kN when 35 kN was entered?
Clause 9.1.4 sets a minimum design shear for a splice in a flexural member. The program takes the larger of 0.15 times the design shear capacity of the uncoped beam and 40 kN. For a 410 UB 53.7 that is 0.15 x 529.25 kN = 79.388 kN, which is more than the 35 kN entered, so the shear checks use 79.388 kN. The moment is treated the same way, but 192 kNm is already above its minimum of 0.3 times the beam’s design section moment capacity.
Why is the end plate checked against 338.86 kNm when the design moment is 192 kNm?
The end plate is designed to be thick enough that the bolts are free of prying, as Clause 9.1.8 requires prying to be allowed for. The module asks for a plate bending capacity of at least 1.11 times the lesser of the tension bolt capacity and the beam’s design section moment capacity. Here that is 1.11 x 305.28 kNm = 338.86 kNm. The bolt check in Step 5 can then use the full bolt tension capacity with no prying force added.
Why do only four bolts take the shear?
The four bolts at the tension flange are already working in tension. The design shear is given to the four bolts on the compression side of the neutral axis, [mathin] n_{cw} = 4 [mathin], where the plates are pressed together.
Why are the web welds checked for 392.23 kN when there is no axial force?
On the tension side the web welds are sized to develop the design yield capacity of the web, not just the share of the moment the web carries. If the beam is loaded to its capacity near the splice, the web can yield before the welds do. The demand is therefore a property of the beam, and the ratio of 0.658 stays the same at any load.
What does form 4E mean?
The drawing notes give the end plate form. 4E is four bolt extended and unstiffened: two bolts in one row outside the tension flange and two in one row inside it, repeated at the other flange so the splice works for a moment in either direction. The lever arms in Step 5 and the yield line factor in Step 8 are the 4E ones.
Why are the bolts 8.8/TB?
The bolting category is chosen in the program. TB means the bolts are fully tensioned and designed as a bearing joint, so the shear and bearing checks of Clauses 9.2.2.1 and 9.2.2.4 apply. Tensioned bolts are usual in an end plate moment splice, because they keep the plates in contact under service loads.
Design an extended end plate beam splice for free
Every number on this page comes from one solve. Pick AS 4100:2020 and the extended end plate beam splice, enter your beams, end plates, bolts and design actions, and see each of these checks in your browser. There is nothing to install.
The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every design capacity and DCR, for AS 4100:2020 shear connections, moment connections and splices. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.
References
- AS 4100:2020, Steel Structures: Clauses 5.11.2, 7.2, 9.1.4, 9.1.8, 9.2.2.1, 9.2.2.2, 9.2.2.4, 9.3.2, 9.5.1, 9.5.2, 9.5.3, 9.6.3.10, 14.3.2; Tables 2.1, 3.4 and 9.6.3.2.
- Design of steel connections using AS 4100:2020
- Loads and load combinations in SkyCiv Connection Design
Harold Munalem
Product Manager, Connection Design
10+ years in steel connection design
LinkedIn