SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

Channel to Channel Directly Welded Web Connection Design

To design a directly welded web connection between two channels to AISC 360, you check the fillet welds that join the beam web to the girder web against the beam end reaction. There is no plate and there are no bolts, so the design comes down to two things: a weld group that fits on the flat of the beam web and is at least the minimum size, and a weld that is strong enough once the base metal on both sides of it is accounted for.

This page works through one example from start to finish: a C10x20 beam framing into the back of a C15x50 girder channel, with a 25 kip LRFD reaction carried by 1/4 in E70XX fillet welds on both sides of the beam web, designed to AISC 360-16 and the AISC Manual 15th Edition. Every equation is written out with its numbers, in the same order as the AISC calc sheet the SkyCiv Connection Design module produces for it.

What is a channel to channel directly welded web connection?

It is a shear connection in which the end of a channel beam is welded straight to a channel girder, with no connecting element in between. The beam web butts against the girder and a fillet weld runs down each side of the beam web. It suits shop-assembled frames, platforms and secondary framing where channels are used for both members and a bolted field joint is not needed.

This example uses the BBC orientation, beam to back of channel. The beam frames to the flat back of the girder’s web, on the side away from its flanges, so the beam needs no cope to clear them. The other orientation, BFC (beam to front of channel), puts the beam between the girder’s flanges.

Elevation of a C10x20 beam welded to the back of a C15x50 channel with 1/4 in E70XX fillet welds on both sides

Elevation from the calculation report: C10x20 beam welded to the back of a C15x50 girder channel

3D view of a C10x20 channel beam directly welded to the web of a C15x50 channel girder

3D view of the connection in SkyCiv Connection Design

Directly welded web connection design: the steps at a glance

  1. Detailing limits: check the minimum fillet weld size and that the welded depth fits on the flat of the beam web.
  2. Weld strength: find the largest weld the base metal can develop, the effective weld length, and the design strength of the two fillet welds.

Design inputs for this example

ItemSymbolValue
Required shear strength (LRFD)[mathin] V_{u} [mathin]25 kip
BeamC10x20, ASTM A36
Beam depth / web thickness[mathin] d_{bm},\ t_{wb} [mathin]10 in / 0.379 in
Beam flange width / thickness[mathin] b_{fb},\ t_{fb} [mathin]2.74 in / 0.436 in
Beam area[mathin] A_{bm} [mathin]10 in²
Beam yield / tensile stress[mathin] F_{yb},\ F_{ub} [mathin]36 ksi / 58 ksi
GirderC15x50, ASTM A36
Girder depth / web thickness[mathin] d_{sup},\ t_{ws} [mathin]15 in / 0.716 in
Girder flange width / thickness[mathin] b_{fs},\ t_{fs} [mathin]3.72 in / 0.65 in
Girder area[mathin] A_{sup} [mathin]14.7 in²
Girder yield / tensile stress[mathin] F_{ys},\ F_{us} [mathin]36 ksi / 58 ksi
Modulus of elasticity[mathin] E [mathin]29000 ksi
WeldSymbolValue
ElectrodeE70XX
Filler metal classification strength[mathin] F_{EXX} [mathin]70 ksi
Fillet weld size, both sides of the beam web[mathin] W [mathin]1/4 in (0.25 in)
Welded depth[mathin] L_{d} [mathin]8 in

Step 1: Connection detailing limitations (AISC 360-16 J2.2b)

The weld has to stay on the flat part of the beam web, clear of the flange-to-web fillets. The program takes the web lost at each flange as the larger of the design k distance and the cope depth. This beam has no copes, so each is 1 in.

[math] D_{max} = d_{det\_bm} – c_{t} – c_{b} = (10\ \text{in}) – (1\ \text{in}) – (1\ \text{in}) = 8\ \text{in} [math]

The welded depth of 8 in uses the full flat depth. The minimum fillet weld size of 3/16 in is the AISC 360-16 Table J2.4 value for the thinner part joined, the 0.379 in beam web. The 4 in minimum connection depth is the software’s limit.

Detailing limitLimit (in)Actual (in)DCRResult
Minimum fillet weld size0.1880.2500.750PASS
Minimum connection depth4.0008.0000.500PASS
Maximum connection depth8.0008.0001.000PASS

DCR = 8 / 8 = 1.000 ≤ 1.0, OK

Step 2: Design capacity of the weld (AISC 360-16 J2.4)

Base metal limit on weld size (AISC Manual Eq. 9-2)

A fillet weld can be no stronger than the metal it is fused to. On the girder side the weld sits on the 0.716 in girder web. On the beam side the beam web carries a weld on each face, so each weld gets half of the 0.379 in web, 0.1895 in. The smaller of the two products governs, expressed as a weld size in sixteenths of an inch:

[math] D_{max} = \frac{\min\left(t_{ws} F_{us},\ \frac{t_{wb}}{2} F_{ub}\right)}{3.09\ \text{kip/in} \times F_{EXX}/F_{E70XX}} = \frac{\min\left((0.716\ \text{in})(58\ \text{ksi}),\ (0.1895\ \text{in})(58\ \text{ksi})\right)}{(3.09\ \text{kip/in}) \times (1)} = 3.557 [math]

The beam web governs. A weld of 3.557 sixteenths is [mathin] 3.557/16 = 0.222 [mathin] in, which is smaller than the 1/4 in weld, so the strength equation below uses the 0.222 in size the beam web can develop.

Effective weld length (AISC Manual Part 10)

Each of the two welds runs the 8 in welded depth, less two weld sizes for the ends:

[math] L_{w} = 2 \left[ L_{d} – 2W \right] = 2 \times \left[ (8\ \text{in}) – 2 \times (0.25\ \text{in}) \right] = 15\ \text{in} [math]

Weld strength (Eq. J2-4)

With [mathin] \phi = 0.75 [mathin] and the load parallel to the welds ([mathin] \theta_{u} = 0 [mathin]):

[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left(W,\ \frac{D_{max}}{16}\right) \left[1 + 0.5 \left(\sin \theta_{u}\right)^{1.5}\right] L_{w} [math]

[math] \phi R_{n} = (0.75) \times 0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left(0.25\ \text{in},\ \frac{3.557}{16}\right) \times \left[1 + 0.5 \times (\sin 0)^{1.5}\right] \times (15\ \text{in}) = 74.275\ \text{kip} [math]

[math] V_{u} = 25\ \text{kip} \le \phi R_{n} = 74.275\ \text{kip} [math]

DCR = 25 kip / 74.275 kip = 0.337 ≤ 1.0, OK

Summary of checks

CheckDemandCapacityDCRResult
Connection detailing limitations8 in8 in1.000PASS
**Design capacity of weld****25 kip****74.275 kip****0.337****PASS**

The connection passes both checks. The detailing ratio of 1.000 is not a strength ratio: it shows that the 8 in weld uses the whole flat of the C10x20 web, which is the most this beam allows. The weld is the governing strength check at 0.337, and its strength is limited by the thin beam web rather than by the 1/4 in weld itself.

Auto Design is available for the channel to channel directly welded web connection. It changes the connection’s design variables until every check passes, and keeps your members and loads as entered. See the Auto Design page for the preferences it works to.

What to change if a check fails

  • Maximum connection depth: the welded depth cannot be more than the flat of the beam web, here 8 in. If you need more weld, use a deeper beam or a connection with a plate or angles.
  • Minimum fillet weld size: use at least the Table J2.4 minimum for the thinner part joined, here 3/16 in.
  • Weld strength: lengthen the weld up to the maximum depth first. A larger weld only helps until it reaches the base metal limit. In this example the beam web already limits the effective size to 0.222 in, so a 5/16 in weld would add no strength. Past that point, use a beam with a thicker web or a connection with a plate or angles.

Frequently asked questions

Why is the effective weld size 0.222 in when the weld is 1/4 in?

AISC Manual Eq. 9-2 limits the weld to what the base metal can develop in shear. The beam web is 0.379 in thick and has a weld on each face, so each weld is matched against half of it. That half-web can only develop a weld of 3.557 sixteenths, 0.222 in, and the extra size of the 1/4 in weld is not counted.

Why is the weld length 15 in when the welded depth is 8 in?

There are two welds, one on each side of the beam web. Each is 8 in long less two weld sizes for the ends, 7.5 in, so the total effective length is 15 in.

What does BBC mean?

BBC is beam to back of channel. The beam frames to the flat back of the girder channel’s web, away from its flanges. In BFC, beam to front of channel, the beam frames in between the girder’s flanges.

Is the girder web checked?

The girder web enters the design through the base metal check of Step 2, where its 0.716 in thickness is compared with the beam web’s half thickness. In this example the beam web is the weaker of the two, so it sets the weld strength.

How would this change for ASD instead of LRFD?

The equations are the same. The program uses the ASD safety factor in place of the LRFD resistance factor and compares the result with the ASD required strength.

Design a directly welded web connection for free

Every number on this page comes from one solve. Pick the channel to channel category and the directly welded web configuration, enter your beam, girder, weld and reaction, and see each of these checks in your browser. There is nothing to install.

The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every capacity and DCR, for AISC 360-22 and AISC 360-16 (LRFD and ASD) and AS 4100:2020. The weld calculator covers the weld checks on their own.

References

  • AISC 360-16, Specification for Structural Steel Buildings: J2.2b (Table J2.4), J2.4 (Eq. J2-4).
  • AISC Steel Construction Manual, 15th Edition: Part 9, Eq. 9-2; Part 10, effective weld length.
  • Design of steel connections using AISC 360-16
  • Welds in SkyCiv Connection Design
Harold Munalem, Product Manager for SkyCiv Connection Design

Harold Munalem
Product Manager, Connection Design
10+ years in steel connection design
LinkedIn

How can we help?

×

Updated November 24, 2026

Still stuck? Contact us