SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

Flange Plate Moment Connection Design to AS 4100

To design a bolted flange plate moment connection to AS 4100, you turn the beam end moment into a tension and compression force pair at the flanges, then follow each flange force from the beam flange, through the bolts and the flange plate, into the weld and the column. The web side plate is a separate shear connection that carries the vertical shear. Both are checked against their detailing limits first.

This page works through one example from start to finish: a 460 UB 74.6 beam joined to the flange of a 310 UC 158 column with 25 mm Grade 300 flange plates, eight M20 8.8/S bolts per flange and a 10 mm web side plate. It is designed to AS 4100:2020 for a moment of 70 kNm, a shear of 80 kN and an axial envelope of 60 kN tension and 90 kN compression. Every equation is written out with its numbers, in the same order as the calculation report that the SkyCiv Connection Design module produces for it. The scope and conventions of the AS 4100 module are on the design of steel connections using AS 4100:2020 page.

What is a flange plate moment connection?

A flange plate moment connection has a plate on the top and bottom flanges of the beam. Each plate is fillet welded to the column flange in the shop and bolted to the beam flange on site, so the flange forces from the moment pass through the plates in tension or compression. A web side plate, welded to the column and bolted to the beam web, carries the shear. Because the field joint is bolted, the beam can be erected without site welding.

It is a rigid connection, so AS 4100 Clause 9.1.4 asks for a minimum design moment as well as the design actions from the analysis. The other AS 4100 moment connections in the module do the same job with an end plate welded to the beam. You can check this one directly in the flange plate connection calculator.

In this example each flange plate has four rows of two bolts, with a 75 mm pitch along the beam and a 110 mm gauge across it.

Flange plate moment connection elevation: 460 UB 74.6 bolted to 25 mm flange plates welded to a 310 UC 158 flange

Elevation of the example connection. The flange plates are welded to the column flange with 10 mm fillets, and the web side plate carries the shear.

Section A-A plan of the 25 mm Gr.300 flange plate with eight M20 8.8/S bolts at 75 mm pitch and 110 mm gauge

Section A-A, a plan of the flange plate. The first bolt row is 70 mm from the face of the column.

SkyCiv Connection Design 3D view of the flange plate moment connection between a 460 UB 74.6 and a 310 UC 158

The same connection in the 3D view of SkyCiv Connection Design.

Flange plate moment connection design: the steps at a glance

  1. Check the flange plate detailing limits: pitch, gauge, edge distances and weld size.
  2. Set the design moment, not less than the Clause 9.1.4 minimum, find the flange forces, and check the bolts in shear.
  3. Check the bolts in bearing on the flange plate and the beam flange.
  4. Check the weld of the flange plate to the column.
  5. Check block shear of the flange plate and of the beam flange.
  6. Check the flange plate in tension and in compression, and the beam flange in tension.
  7. Check the section moment capacity of the beam at the flange bolt holes.
  8. Check the column flange and web at the flange plate.
  9. Check the web side plate shear connection: detailing, weld, bolts, plate and beam web.

Design inputs for this example

The design code is AS 4100:2020, with section properties from the Australian section database. The yield strength of each part follows its grade and thickness: 300 MPa for the beam, 280 MPa for the column with its 25 mm flange, 280 MPa for the 25 mm flange plate and 310 MPa for the 10 mm web side plate.

ItemSymbolValue
Shear (Fy)[mathin] V^{*} [mathin]80 kN
Axial (Fx), envelope[mathin] N^{*}_{t},\ N^{*}_{c} [mathin]60 kN tension / 90 kN compression
Major axis moment (Mz)[mathin] M^{*}_{x} [mathin]70 kNm
Beam460 UB 74.6, AS/NZS 3679.1 Gr.300
Beam depth / web thickness[mathin] d_{bm},\ t_{wb} [mathin]457 mm / 9.1 mm
Beam flange width / thickness[mathin] b_{fb},\ t_{fb} [mathin]190 mm / 14.5 mm
Beam area / plastic section modulus[mathin] A_{bm},\ S_{x} [mathin]9520 mm² / 1.66 x 10⁶ mm³
Beam yield / tensile strength[mathin] f_{yb},\ f_{ub} [mathin]300 MPa / 440 MPa
Column310 UC 158, AS/NZS 3679.1 Gr.300
Column depth / web thickness[mathin] d_{sup},\ t_{ws} [mathin]327 mm / 15.7 mm
Column flange width / thickness[mathin] b_{fs},\ t_{fs} [mathin]311 mm / 25 mm
Column root radius[mathin] r_{s} [mathin]16.5 mm
Column yield / tensile strength[mathin] f_{ys},\ f_{us} [mathin]280 MPa / 440 MPa
Elastic modulus[mathin] E [mathin]200000 MPa
Flange plates (top and bottom)SymbolValue
Flange platePL 25 x 210 x 345, AS/NZS 3678 Gr.300
Plate width / length / thickness[mathin] b_{p},\ l_{p},\ t_{p} [mathin]210 mm / 345 mm / 25 mm
Plate yield / tensile strength[mathin] f_{yp},\ f_{up} [mathin]280 MPa / 430 MPa
Bolts to the beam flangeM20 8.8/S, threads included in the shear plane
Bolt diameter / minimum tensile strength[mathin] d_{ff},\ f_{uf} [mathin]20 mm / 830 MPa
Holes in plate and beam flange[mathin] d_{h} [mathin]Nominal, 22 mm
Bolt rows / row pitch[mathin] n_{p},\ s_{p} [mathin]4 / 75 mm
Bolt columns / gauge[mathin] n_{g},\ s_{g} [mathin]2 / 110 mm
Support face to first bolt row[mathin] l [mathin]70 mm
Edge distances on plate (end / side)[mathin] l_{ev\_fp},\ l_{eh\_fp} [mathin]50 mm / 50 mm
Edge distances on beam flange (end / side)[mathin] l_{ev\_f},\ l_{eh\_f} [mathin]40 mm / 50 mm
Weld to column flange10 mm fillet, E49XX, SP
Weld size / weld metal strength[mathin] t_{wf},\ f_{uw} [mathin]10 mm / 490 MPa
Web side plateSymbolValue
Web side platePL 10 x 120 x 325, AS/NZS 3678 Gr.300
Plate yield / tensile strength[mathin] f_{yp},\ f_{up} [mathin]310 MPa / 430 MPa
Bolts4 x M20 8.8/S in one column, 75 mm pitch
Edge distances on plate / on beam web[mathin] l_{ev\_wp},\ l_{eh\_wp},\ l_{eh\_w} [mathin]50 mm / 50 mm / 50 mm
Beam end clearance / first bolt column[mathin] clr,\ l [mathin]20 mm / 70 mm
Bolt group eccentricity[mathin] e_{b} [mathin]70 mm
Weld to column flange10 mm fillet both sides, E49XX, SP

The axial load is entered as an envelope, 60 kN in tension and 90 kN in compression. The two are separate cases, so the tension checks use the tension and the compression checks use the compression, and neither relieves the other.

Step 1: Flange plate detailing limitations (AS 4100 Clause 9.5)

The bolt layout on the flange plate and the beam flange has to be buildable and match the assumptions behind the capacity equations. The minimum pitch is [mathin] 2.5\, d_{f} = 2.5 \times 20\ \text{mm} = 50\ \text{mm} [mathin] (Clause 9.5.1), and the minimum edge distance for an M20 bolt is 35 mm, [mathin] 1.75\, d_{f} [mathin] from Table 9.5.2. The minimum fillet weld for the 25 mm plate on the 25 mm column flange is 6 mm (Table 9.6.3.2).

Detailing limitLimit (mm)Actual (mm)DCRResult
Minimum bolt row pitch on flange plate50.00075.0000.667PASS
Maximum bolt row pitch on flange plate158.00075.0000.475PASS
Minimum bolt column pitch on flange plate50.000110.0000.455PASS
Maximum bolt column pitch on flange plate200.000110.0000.550PASS
Minimum bolt gauge on beam flange71.900110.0000.654PASS
Minimum vertical edge distance on flange plate35.00050.0000.700PASS
Minimum vertical edge distance on beam flange35.00040.0000.875PASS
Minimum horizontal edge distance on flange plate35.00050.0000.700PASS
Minimum horizontal edge distance on beam flange35.00050.0000.700PASS
Maximum edge distance150.00050.0000.333PASS
Minimum fillet weld size at flange plate to column flange6.00010.0000.600PASS

For a minimum limit the ratio is limit over actual, and for a maximum it is actual over limit. The governing row is the end distance on the beam flange, from the last bolt row to the end of the beam:

[math] DCR = \frac{35\ \text{mm}}{40\ \text{mm}} = 0.875 [math]

DCR = 0.875 ≤ 1.0, OK

Step 2: Bolt group in shear (AS 4100 Clauses 9.1.4, 9.2.2.1, 9.3.1)

Design moment and flange forces

The connection is rigid, so Clause 9.1.4 sets the design moment at not less than half the design section moment capacity of the beam:

[math] M^{*} = \max\left( M^{*}_{x},\ 0.5\, \phi\, f_{yb}\, S_{x} \right) = \max\left( 70\ \text{kNm},\ 0.5 \times 0.9 \times (300\ \text{MPa}) \times (1.66 \times 10^{6}\ \text{mm}^{3}) \right) = 224.1\ \text{kNm} [math]

The 70 kNm from the analysis is below the minimum, so 224.1 kNm is used for every flange check. The moment is split into a flange force pair over the distance between the flange centres, and half the axial load is added to each flange:

[math] N^{*}_{f} = \frac{M^{*}}{d_{bm} – t_{fb}} + \frac{\max\left( N^{*}_{t},\ N^{*}_{c} \right)}{2} = \frac{224.1\ \text{kNm}}{457\ \text{mm} – 14.5\ \text{mm}} + \frac{90\ \text{kN}}{2} = 551.44\ \text{kN} [math]

With the envelope taken case by case, the force in the tension flange is [mathin] N^{*}_{ft} = 536.44\ \text{kN} [mathin] (with the 60 kN tension) and the force in the compression flange is [mathin] N^{*}_{fc} = 551.44\ \text{kN} [mathin] (with the 90 kN compression). The bolts, welds and block shear take the larger force, 551.44 kN.

Bolt capacity

The bolted length along the force is [mathin] l_{j} = (n_{p} – 1)\, s_{p} = 3 \times 75\ \text{mm} = 225\ \text{mm} [mathin], less than 300 mm, so the lap connection factor [mathin] k_{r} = 1 [mathin] (Clause 9.2.2.1). The threads are in the single shear plane, so the core area is used:

[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, k_{rd}\, k_{r}\, \left( n_{n} A_{c} + n_{x} A_{o} \right) [math]

[math] \phi V_{f} = (0.8) \times 0.62 \times (830\ \text{MPa}) \times (1) \times (1) \times \left( (1)(225\ \text{mm}^{2}) + (0)(314.16\ \text{mm}^{2}) \right) = 92.628\ \text{kN} [math]

The flange force is concentric with the bolt group, so all eight bolts share it (Clause 9.3.1):

[math] \phi V_{df} = n_{b}\, \phi V_{f} = 8 \times (92.628\ \text{kN}) = 741.02\ \text{kN} [math]

[math] N^{*}_{f} = 551.44\ \text{kN} \le \phi V_{df} = 741.02\ \text{kN} [math]

DCR = 551.44 kN / 741.02 kN = 0.744 ≤ 1.0, OK

Step 3: Bolt group in bearing on the flange plate and the beam flange (AS 4100 Clause 9.2.2.4)

Each bolt bears on the flange plate and on the beam flange. The end bolts are limited by the distance to the end of the ply, and the inner bolts by the distance to the next hole. For the flange plate, with [mathin] d_{h} = 22\ \text{mm} [mathin]:

[math] a_{e1} = l_{eh\_fp} – 0.5\, d_{h} + 0.5\, d_{f} = (50\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 49\ \text{mm} [math]

[math] a_{e2} = s_{p} – d_{h} + 0.5\, d_{f} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

The bearing capacity of a ply, with a capacity factor of 0.9:

[math] \phi V_{b} = \phi \min\left( 3.2\, d_{f}\, t_{p}\, f_{up},\ a_{e}\, t_{p}\, f_{up} \right) [math]

For the 25 mm plate this gives 474.07 kN at each end bolt and 609.52 kN at each inner bolt. Each bolt column has one end bolt and three inner bolts:

[math] \phi V_{b,pl} = 2 \left[ 474.07\ \text{kN} + 3 \times (609.52\ \text{kN}) \right] = 4605.3\ \text{kN} [math]

The 14.5 mm beam flange, with its 440 MPa tensile strength, gives 281.36 kN at each end bolt and 361.75 kN at each inner bolt:

[math] \phi V_{b,beam} = 2 \left[ 281.36\ \text{kN} + 3 \times (361.75\ \text{kN}) \right] = 2733.2\ \text{kN} [math]

[math] \phi V_{b} = \min\left( 4605.3\ \text{kN},\ 2733.2\ \text{kN} \right) = 2733.2\ \text{kN} [math]

DCR = 551.44 kN / 2733.2 kN = 0.202 ≤ 1.0, OK

Step 4: Weld of the flange plate to the column (AS 4100 Clause 9.6.3.10)

The flange force passes from the plate into the column flange through the fillet welds across the plate width. The weld is Structural Purpose (SP), so the capacity factor is 0.8 from Table 3.4:

[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{wf}\, k_{r} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (10\ \text{mm}) \times (1) = 1.6631\ \text{kN/mm} [math]

The weld length is the plate width, not more than the column flange width: [mathin] l_{w} = \min\left( b_{p},\ b_{fs} \right) = \min\left( 210\ \text{mm},\ 311\ \text{mm} \right) = 210\ \text{mm} [mathin]. The plate is welded on both faces:

[math] \phi N_{w} = 2\, l_{w}\, \phi v_{w} = 2 \times (210\ \text{mm}) \times (1.6631\ \text{kN/mm}) = 698.51\ \text{kN} [math]

[math] N^{*}_{f} = 551.44\ \text{kN} \le \phi N_{w} = 698.51\ \text{kN} [math]

DCR = 551.44 kN / 698.51 kN = 0.789 ≤ 1.0, OK

This is the governing strength check. The weld length is set by the plate width, so a larger fillet or a wider plate is the way to add capacity here.

Step 5: Flange plate in block shear (AS 4100 Clause 9.1.9)

A block of the flange plate can tear out around the bolts: shear along the bolt lines plus tension across them. Three patterns are checked. The capacity factor is 0.75 and the tension stress is uniform, so [mathin] k_{bs} = 1 [mathin]:

[math] \phi R_{bs} = \phi \min\left( 0.6\, f_{up}\, A_{nv} + k_{bs}\, f_{up}\, A_{nt},\ 0.6\, f_{yp}\, A_{gv} + k_{bs}\, f_{up}\, A_{nt} \right) [math]

Patterns 1 and 2 shear along both bolt columns:

[math] A_{gv} = 2 \left[ l_{eh} + (n_{p} – 1)\, s_{p} \right] t_{p} = 13750\ \text{mm}^{2}, \qquad A_{nv} = 2 \left[ l_{eh} + (n_{p} – 1)\, s_{p} – (n_{p} – 0.5)\, d_{h} \right] t_{p} = 9900\ \text{mm}^{2} [math]

Pattern 1 tears across between the bolt columns, [mathin] A_{nt} = \left[ s_{g} – (n_{g} – 1)\, d_{h} \right] t_{p} = 2200\ \text{mm}^{2} [mathin], giving 2442 kN. Pattern 2 tears out to both side edges, [mathin] A_{nt} = (2\, l_{ev} – d_{h})\, t_{p} = 1950\ \text{mm}^{2} [mathin], giving 2361.4 kN. Pattern 3 is an L-shaped block along one bolt column and out to one side edge:

[math] A_{nt} = \left[ l_{ev} + (n_{g} – 1)\, s_{g} – (n_{g} – 0.5)\, d_{h} \right] t_{p} = 3175\ \text{mm}^{2}, \qquad A_{gv} = 6875\ \text{mm}^{2}, \qquad A_{nv} = 4950\ \text{mm}^{2} [math]

[math] \phi R_{bs} = \min\left( 2442\ \text{kN},\ 2361.4\ \text{kN},\ 1890.2\ \text{kN} \right) = 1890.2\ \text{kN} [math]

DCR = 551.44 kN / 1890.2 kN = 0.292 ≤ 1.0, OK

Step 6: Beam flange in block shear (AS 4100 Clause 9.1.9)

On the beam flange, the block tears out along both bolt columns to the end of the beam and across to the two flange edges:

[math] A_{nt} = (2\, l_{ev\_f} – d_{h})\, t_{fb} = 841\ \text{mm}^{2}, \qquad A_{gv} = 2 \left[ 50\ \text{mm} + 3 \times 75\ \text{mm} \right] \times 14.5\ \text{mm} = 7975\ \text{mm}^{2}, \qquad A_{nv} = 5742\ \text{mm}^{2} [math]

[math] \phi R_{bs} = 1354.2\ \text{kN} [math]

DCR = 551.44 kN / 1354.2 kN = 0.407 ≤ 1.0, OK

Step 7: Flange plate in tension (AS 4100 Clauses 9.1.10, 7.2, 7.3)

The tension flange plate carries the tension flange force. Its design section capacity is the lesser of yield on the gross area and fracture on the net area across a bolt row:

[math] A_{g} = b_{p}\, t_{p} = 5250\ \text{mm}^{2}, \qquad A_{n} = (b_{p} – n_{g}\, d_{h})\, t_{p} = 4150\ \text{mm}^{2} [math]

[math] \phi N_{t} = \phi \min\left( A_{g}\, f_{y},\ 0.85\, k_{t}\, A_{n}\, f_{u} \right) = 1323\ \text{kN} [math]

DCR = 536.44 kN / 1323 kN = 0.405 ≤ 1.0, OK

Step 8: Flange plate in compression (AS 4100 Clauses 6.2.1, 6.2.2)

The compression flange plate carries the compression flange force. The bolt holes are filled by the bolts, so no reduction is made for them:

[math] \phi N_{s} = \phi\, k_{f}\, A_{g}\, f_{y} = 1323\ \text{kN} [math]

DCR = 551.44 kN / 1323 kN = 0.417 ≤ 1.0, OK

Step 9: Beam flange in tension (AS 4100 Clauses 7.2, 7.3)

The beam flange itself carries the tension flange force into the bolts. With two holes across the flange:

[math] A_{g} = 2755\ \text{mm}^{2}, \qquad A_{n} = 2117\ \text{mm}^{2}, \qquad \phi N_{t} = 712.58\ \text{kN} [math]

DCR = 536.44 kN / 712.58 kN = 0.753 ≤ 1.0, OK

This is the second-highest strength ratio. The beam flange is thinner than the flange plate and loses two 22 mm holes from its 190 mm width.

Step 10: Section moment capacity of the beam at the flange holes (AS 4100 Clauses 5.2.6, 5.2, 8.3.2)

The bolt holes in the beam flanges reduce the beam section at the bolts. Clause 5.2.6 allows the holes to be ignored only when they remove a small enough part of the flange. Here they do not:

[math] \Delta A_{f} = \frac{100\, n_{g}\, d_{h}}{b_{fb}} = 23.158 > \Delta A_{lim} = 19.786 [math]

So the section moduli are reduced by the ratio of the net area to the gross area. The net area deducts the flange holes:

[math] A_{n} = A – 2\, n_{g}\, d_{h}\, t_{fb} = 8244\ \text{mm}^{2} [math]

The section is compact under Clause 5.2.2 ([mathin] \lambda_{ef} = 6.8333 [mathin], [mathin] \lambda_{ew} = 51.522 [mathin]), so the effective section modulus is the reduced plastic modulus, capped at 1.5 times the reduced elastic modulus:

[math] S_{n} = \frac{A_{n}}{A} S_{x} = 1.4375 \times 10^{6}\ \text{mm}^{3}, \qquad Z_{n} = \frac{A_{n}}{A} Z_{x} = 1.2479 \times 10^{6}\ \text{mm}^{3} [math]

[math] Z_{e} = \min\left( S_{n},\ 1.5\, Z_{n} \right) = 1.4375 \times 10^{6}\ \text{mm}^{3}, \qquad \phi M_{s} = \phi\, f_{y}\, Z_{e} = 388.13\ \text{kNm} [math]

The axial load reduces the moment capacity (Clause 8.3.2). In tension, the net area also deducts the holes of the nearest web bolt column, [mathin] A_{nw} = 7443.2\ \text{mm}^{2} [mathin], giving [mathin] \phi N_{t} = 2505.4\ \text{kN} [mathin], and the reduced capacity stays at 388.13 kNm. In compression, the effective area for local buckling is [mathin] A_{e} = 9027\ \text{mm}^{2} [mathin], so [mathin] k_{f} = 0.94821 [mathin] and [mathin] \phi N_{s} = 2437.3\ \text{kN} [mathin]. The 90 kN compression governs:

[math] \phi M_{rx} = \phi M_{s} \left( 1 – \frac{N^{*}_{c}}{\phi N_{s}} \right) = (388.13\ \text{kNm}) \times \left( 1 – \frac{90\ \text{kN}}{2437.3\ \text{kN}} \right) = 373.79\ \text{kNm} [math]

[math] M^{*} = 224.1\ \text{kNm} \le \phi M_{rx} = 373.79\ \text{kNm} [math]

DCR = 224.1 kNm / 373.79 kNm = 0.600 ≤ 1.0, OK

Step 11: Supporting member at the flange plate (AS 4100 Clauses 5.11, 5.13)

Each flange plate delivers its force to one side of the column flange, so the column flange and web are checked locally. The flange plate is taken as at least [mathin] 10\, t_{fs} [mathin] from the column end, so no capacity is halved. The stiff bearing length is the plate thickness plus a weld leg each side, dispersed 1:1 through the welds (Clause 5.13.1): [mathin] b_{s} = t_{p} + 2\, t_{wf} = 25\ \text{mm} + 2 \times 10\ \text{mm} = 45\ \text{mm} [mathin].

Column flange in local bending, at the tension flange plate:

[math] \phi R_{fb} = \phi\, 6.25\, t_{fs}^{2}\, f_{ys} = 984.38\ \text{kN} [math]

Column web in local yielding, at the tension flange plate:

[math] \phi R_{wy} = \phi\, f_{ys}\, t_{ws} \left[ 5 (t_{fs} + r_{s}) + b_{s} \right] = 999\ \text{kN} [math]

Column web in bearing yield, at the compression flange plate (Clause 5.13.3), with the bearing width dispersed through the column flange on both sides, [mathin] b_{bf} = b_{s} + 5\, t_{fs} = 170\ \text{mm} [mathin]:

[math] \phi R_{by} = \phi\, 1.25\, b_{bf}\, t_{ws}\, f_{ys} = 840.74\ \text{kN} [math]

Column web in crippling, with [mathin] \phi = 0.75 [mathin]:

[math] \phi R_{wc} = \phi\, 0.8\, t_{ws}^{2} \left[ 1 + 3 \frac{b_{s}}{d_{sup}} \left( \frac{t_{ws}}{t_{fs}} \right)^{1.5} \right] \sqrt{\frac{E\, f_{ys}\, t_{fs}}{t_{ws}}} = 1683.5\ \text{kN} [math]

Column web in bearing buckling (Clauses 5.13.4 and 6.3.3). The web is a compression member over its clear depth [mathin] d_{1} = 277\ \text{mm} [mathin], with a bearing width of [mathin] b_{b} = 447\ \text{mm} [mathin] and an area of [mathin] A_{wb} = 7017.9\ \text{mm}^{2} [mathin]. With [mathin] l_{e}/r = 2.5\, d_{1}/t_{ws} = 44.108 [mathin], [mathin] \lambda_{n} = 46.68 [mathin] and [mathin] \alpha_{b} = 0.5 [mathin], the slenderness reduction factor is [mathin] \alpha_{c} = 0.82729 [mathin]:

[math] \phi R_{bb} = \phi\, \alpha_{c}\, k_{f}\, A_{wb}\, f_{ys} = 1463.1\ \text{kN} [math]

Column web panel in shear (Clauses 5.11.2 and 5.11.4). The panel is stocky, [mathin] d_{p}/t_{w} = 17.643 \le 77.483 [mathin], and its shear area is [mathin] A_{ws} = d_{sup}\, t_{ws} = 5133.9\ \text{mm}^{2} [mathin]:

[math] \phi V_{c} = \phi\, 0.6\, f_{ys}\, A_{ws} = (0.9) \times 0.6 \times (280\ \text{MPa}) \times (5133.9\ \text{mm}^{2}) = 776.25\ \text{kN} [math]

[math] \phi R_{n} = \min\left( 984.38,\ 999,\ 840.74,\ 1683.5,\ 1463.1,\ 776.25 \right)\ \text{kN} = 776.25\ \text{kN} [math]

DCR = 551.44 kN / 776.25 kN = 0.710 ≤ 1.0, OK

The panel shear governs the column. The connection is one-sided, so the whole flange force goes into the panel as shear.

Step 12: Web side plate detailing limitations (AS 4100 Clause 9.5)

The web side plate is checked as its own shear connection, for the 80 kN shear. Its layout is one column of four M20 bolts at 75 mm pitch.

Detailing limitLimit (mm)Actual (mm)DCRResult
Minimum bolt row pitch on web side plate50.00075.0000.667PASS
Maximum bolt row pitch on web side plate136.40075.0000.550PASS
Minimum vertical edge distance on web side plate35.00050.0000.700PASS
Minimum horizontal edge distance on web side plate35.00050.0000.700PASS
Minimum horizontal edge distance on beam web35.00050.0000.700PASS
Minimum web side plate depth228.500325.0000.703PASS
Maximum web side plate depth405.200325.0000.802PASS
Minimum clearance20.00020.0001.000PASS
Maximum edge distance109.20050.0000.458PASS

The governing row is the clearance between the beam end and the column flange, which was set at the 20 mm minimum:

DCR = 20 mm / 20 mm = 1.000 ≤ 1.0, OK

Step 13: Minimum weld size of the web side plate (AS 4100 Clause 9.6.3)

The weld of the web side plate to the column is sized to develop the plate, taken by the program as three quarters of the plate thickness:

[math] 0.75\, t_{i} = 0.75 \times (10\ \text{mm}) = 7.5\ \text{mm} \le t_{ww} = 10\ \text{mm} [math]

DCR = 7.5 mm / 10 mm = 0.750 ≤ 1.0, OK

Step 14: Weld of the web side plate to the column (AS 4100 Clauses 9.1.4, 9.6.3.10)

The minimum design shear for the shear connection (Clause 9.1.4) is the lesser of 0.15 times the beam’s shear capacity, [mathin] 0.15 \times 673.71\ \text{kN} [mathin], and 40 kN, so 40 kN. The 80 kN shear is larger and is used. The welds run the full 325 mm plate depth on both sides, with no eccentricity:

[math] \phi v_{w} = 1.6631\ \text{kN/mm}, \qquad \phi V_{w} = 2\, l_{w}\, \phi v_{w} = 2 \times (325\ \text{mm}) \times (1.6631\ \text{kN/mm}) = 1081\ \text{kN} [math]

DCR = 80 kN / 1081 kN = 0.074 ≤ 1.0, OK

Step 15: Web side plate bolt group in shear (AS 4100 Clauses 9.2.2.1, 9.3.1)

The shear acts 70 mm from the bolt line, so the bolt group is analysed by the instantaneous centre of rotation (ICOR) method. The design shear capacity of one bolt is the same as in Step 2, [mathin] \phi V_{f} = 92.628\ \text{kN} [mathin]. The instantaneous centre is at [mathin] x_{ic} = -85.734\ \text{mm} [mathin], [mathin] y_{ic} = 112.5\ \text{mm} [mathin] from bolt 1, at the bottom of the bolt column:

Boltx (mm)y (mm)R (kN)Rx (kN)Ry (kN)
10.000.0090.9172.3155.11
20.0075.0087.1234.9179.81
30.00150.0087.12-34.9179.81
40.00225.0090.91-72.3155.11

[math] \phi V_{df} = \sqrt{ \left( \sum R_{x} \right)^{2} + \left( \sum R_{y} \right)^{2} } = \sqrt{ (0\ \text{kN})^{2} + (269.84\ \text{kN})^{2} } = 269.84\ \text{kN}, \qquad C = \frac{269.84\ \text{kN}}{92.628\ \text{kN}} = 2.9132 [math]

DCR = 80 kN / 269.84 kN = 0.296 ≤ 1.0, OK

Step 16: Web side plate bolt group in bearing (AS 4100 Clause 9.2.2.4)

The least edge distance governs each ply. On the plate, [mathin] a_{e} = \min(49,\ 63,\ 49)\ \text{mm} = 49\ \text{mm} [mathin], and on the beam web, [mathin] a_{e} = \min(63,\ 49)\ \text{mm} = 49\ \text{mm} [mathin]:

[math] \phi V_{b,pl} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (10\ \text{mm}) \times (430\ \text{MPa}),\ (49\ \text{mm}) \times (10\ \text{mm}) \times (430\ \text{MPa}) \right) = 189.63\ \text{kN} [math]

[math] \phi V_{b,beam} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (9.1\ \text{mm}) \times (440\ \text{MPa}),\ (49\ \text{mm}) \times (9.1\ \text{mm}) \times (440\ \text{MPa}) \right) = 176.58\ \text{kN} [math]

[math] \phi V_{b} = \min\left( 189.63\ \text{kN},\ 176.58\ \text{kN} \right) \times (2.9132) = 514.4\ \text{kN} [math]

DCR = 80 kN / 514.4 kN = 0.156 ≤ 1.0, OK

Step 17: Web side plate in shear (AS 4100 Clause 5.11.3)

[math] \phi V_{v} = \phi\, 0.5\, f_{yp}\, d_{i}\, t_{i} = (0.9) \times 0.5 \times (310\ \text{MPa}) \times (325\ \text{mm}) \times (10\ \text{mm}) = 453.38\ \text{kN} [math]

DCR = 80 kN / 453.38 kN = 0.176 ≤ 1.0, OK

Step 18: Web side plate in bending (AS 4100 Clause 5.2.1)

[math] \phi M_{s} = \phi\, \frac{f_{yp}\, t_{i}\, d_{i}^{2}}{4} = (0.9) \times \frac{(310\ \text{MPa}) \times (10\ \text{mm}) \times (325\ \text{mm})^{2}}{4} = 73.673\ \text{kNm} [math]

[math] \phi V_{n} = \frac{\phi M_{s}}{e_{b}} = \frac{73.673\ \text{kNm}}{70\ \text{mm}} = 1052.5\ \text{kN} [math]

DCR = 80 kN / 1052.5 kN = 0.076 ≤ 1.0, OK

Step 19: Web side plate in block shear (AS 4100 Clause 9.1.9)

An L-shaped block tears out along the bolt column and across to the free edge of the plate:

[math] A_{nt} = 390\ \text{mm}^{2}, \qquad A_{gv} = 2750\ \text{mm}^{2}, \qquad A_{nv} = 1980\ \text{mm}^{2} [math]

[math] \phi R_{bs} = (0.75) \times \min\left( 0.6 \times (430)(1980) + (1)(430)(390),\ 0.6 \times (310)(2750) + (1)(430)(390) \right) \times 10^{-3} = 508.9\ \text{kN} [math]

DCR = 80 kN / 508.9 kN = 0.157 ≤ 1.0, OK

Step 20: Supported member in shear (AS 4100 Clause 5.11.2)

[math] \frac{d_{p}}{t_{w}} = 47.033 \le \frac{82}{\sqrt{f_{y} / 250}} = 74.855 [math]

[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (457\ \text{mm}) \times (9.1\ \text{mm}) = 673.71\ \text{kN} [math]

DCR = 80 kN / 673.71 kN = 0.119 ≤ 1.0, OK

Summary of checks

Design checkDesign action effectDesign capacityDCRResult
Flange plate connection
Connection detailing limitations35 mm40 mm0.875PASS
Bolt group in shear551.441 kN741.024 kN0.744PASS
Bolt group in bearing on flange plate and beam flange551.441 kN2733.19 kN0.202PASS
Weld to supporting member551.441 kN698.508 kN0.789PASS
Flange plate in block shear551.441 kN1890.19 kN0.292PASS
Beam flange in block shear551.441 kN1354.15 kN0.407PASS
Flange plate in tension536.441 kN1323 kN0.405PASS
Flange plate in compression551.441 kN1323 kN0.417PASS
Beam flange in tension536.441 kN712.582 kN0.753PASS
Section moment capacity of beam at flange holes224.1 kNm373.794 kNm0.600PASS
Supporting member (column)551.441 kN776.246 kN0.710PASS
Web side plate connection
Connection detailing limitations20 mm20 mm1.000PASS
Minimum weld size7.5 mm10 mm0.750PASS
Weld to supporting member80 kN1081.02 kN0.074PASS
Bolt group in shear80 kN269.843 kN0.296PASS
Bolt group in bearing on plate and beam web80 kN514.4 kN0.156PASS
Web side plate in shear80 kN453.375 kN0.176PASS
Web side plate in bending80 kN1052.48 kN0.076PASS
Web side plate in block shear80 kN508.905 kN0.157PASS
Supported member in shear80 kN673.709 kN0.119PASS

The connection passes every check. The weld of the flange plate to the column governs the strength checks at 0.789, followed by the beam flange in tension at 0.753 and the bolt group in shear at 0.744. Every flange check uses the 224.1 kNm minimum design moment of Clause 9.1.4, not the 70 kNm from the analysis. The web side plate detailing ratio is 1.000 because the beam end clearance was set at its 20 mm minimum, and that is not a strength check.

Auto Design is available for the flange plate moment connection in the AS 4100 module. It changes the bolts, plates and welds until every check passes, and keeps your members and design actions as entered. See the Auto Design page for the AS 4100 preferences it works to.

What to change if a check fails

  • Detailing limits: adjust the pitch, gauge or edge distances to the limits in Step 1. A short end distance on the beam flange can be fixed by moving the bolts along the plate.
  • Bolts in shear or bearing: add a bolt row, or use a larger bolt. If the beam flange governs bearing, increase its end distance or the pitch.
  • Flange plate weld: increase the fillet size, or widen the plate where the column flange allows.
  • Block shear or plate tension and compression: use a thicker or wider plate, or add a bolt row to lengthen the shear planes.
  • Beam flange in tension or beam section at the holes: use a heavier beam.
  • Column checks: use a heavier column.
  • Web side plate: make the plate deeper or thicker, or add bolts, as for any web side plate shear connection.

Frequently asked questions

Why is the connection designed for 224.1 kNm when the moment is 70 kNm?

AS 4100 Clause 9.1.4 sets a minimum design action for a rigid connection: the design moment is not taken less than half the design section moment capacity of the beam. For a 460 UB 74.6 in Grade 300 that is 0.5 x 0.9 x 300 MPa x 1.66 x 10⁶ mm³ = 224.1 kNm. The 70 kNm from the analysis is below it, so the minimum governs.

How are tension and compression handled when the axial load is an envelope?

The 60 kN tension and the 90 kN compression are taken as separate cases. The tension flange checks add half the tension, and the compression flange checks add half the compression, so neither relieves the other. The bolts, welds and block shear take the larger of the two flange forces, 551.44 kN.

Why are the beam section moduli reduced at the bolt holes?

Clause 5.2.6 lets the holes in a flange be ignored only when they remove less than a set part of the flange area. Two 22 mm holes in a 190 mm flange give 23.158 against a limit of 19.786, so the section moduli are reduced by the ratio of the net area to the gross area.

Why does the column web panel shear govern the column checks?

The beam frames into one side of the column only, so the full flange force enters the column web panel as shear. The 310 UC 158 web is stocky, so the panel reaches shear yield at 776.25 kN, which is lower than the flange bending, web yielding, bearing and crippling capacities at the plate.

Does the web side plate carry any of the moment?

No. The moment is carried by the flange plates as a force pair, and the web side plate is designed as a shear connection for the 80 kN shear, with its own Clause 9.1.4 minimum of 40 kN.

Why is the bearing capacity added up bolt by bolt?

The end bolts and the inner bolts have different tear-out distances. An end bolt tears out to the end of the ply, 49 mm here, and an inner bolt tears out to the next hole, 63 mm. Each bolt column has one end bolt and three inner bolts, so the group capacity is the sum of the two kinds, taken for the weaker ply.

Design a flange plate moment connection for free

Every number on this page comes from one solve. Pick AS 4100:2020 and the flange plate moment connection, enter your beam, column, plates, bolts and loads, and see each of these checks in your browser. There is nothing to install.

The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every design capacity and DCR, for AS 4100:2020 shear connections, moment connections and splices. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.

References

  • AS 4100:2020, Steel Structures: Clauses 5.2, 5.2.6, 5.11.2, 5.11.3, 5.11.4, 5.13, 6.2, 6.3.3, 7.2, 7.3, 8.3.2, 9.1.4, 9.1.9, 9.1.10, 9.2.2.1, 9.2.2.4, 9.3.1, 9.5, 9.6.3.10; Tables 3.4, 9.5.2 and 9.6.3.2.
  • Design of steel connections using AS 4100:2020
  • Auto Design in SkyCiv Connection Design
Harold Munalem, Product Manager for SkyCiv Connection Design

Harold Munalem
Product Manager, Connection Design
10+ years in steel connection design
LinkedIn

How can we help?

×

Updated November 24, 2026

Still stuck? Contact us