SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

Extended End Plate Moment Connection Design to AS 4100

To design an extended end plate moment connection to AS 4100, you turn the beam end moment into a tension and compression force pair at the flanges, then follow the tension flange force through the flange welds, the end plate and the tension bolts into the column flange, and the compression flange force into the column web. The shear goes through the web welds and the bolts. The end plate and the column flange are made thick enough that the bolts take no prying force.

This page works through one example from start to finish: a 410 UB 53.7 beam joined to the flange of a 310 UC 158 column with a 28 mm Grade 250 end plate and eight M24 8.8/TB bolts, designed to AS 4100:2020 for a moment of 158 kNm, a shear of 49 kN and an axial compression of 15 kN. Every equation is written out with its numbers, in the same order as the calculation report that the SkyCiv Connection Design module produces for it. The scope and conventions of the AS 4100 module are on the design of steel connections using AS 4100:2020 page.

What is an extended end plate moment connection?

An extended end plate moment connection has a plate fillet welded to the end of the beam in the shop and bolted to the column flange on site. The plate extends beyond the tension flange so that bolts can sit on both sides of it. It is a rigid connection: the moment passes through the plate and the tension bolts, the compression flange bears on the column through the plate, and the shear is carried by the bolts.

This example uses the four-bolt extended, unstiffened form, 4E: one row of two bolts outside each flange and one row inside each flange. It is one of the moment connections in the AS 4100 module, and you can check this one directly in the end plate connection calculator.

Extended end plate elevation: 410 UB 53.7 welded to a 28 mm end plate bolted to a 310 UC 158 flange

Elevation of the example connection. The flanges and the web are welded to the end plate with 8 mm fillets on both sides.

Section A-A of the extended end plate: 28 mm Gr.250 plate, form 4E, eight M24 8.8/TB bolts at a 130 mm gauge

Section A-A through the end plate, showing the four-bolt extended, unstiffened layout.

SkyCiv Connection Design 3D view of the extended end plate moment connection, 410 UB 53.7 to 310 UC 158

The same connection in the 3D view of SkyCiv Connection Design.

Extended end plate moment connection design: the steps at a glance

  1. Check the detailing limits: gauge, pitch, edge distances, plate width and weld size.
  2. Set the design moment, not less than the Clause 9.1.4 minimum, find the flange forces, and check the flange welds.
  3. Check the web welds in tension and in shear.
  4. Check the tension bolts, then the bolt group in shear and in bearing.
  5. Check the end plate in bending and its extension in shear.
  6. Check the column flange in bending at the tension flange.
  7. Check the column web at both flanges: yield, bearing yield, crippling and bearing buckling.
  8. Check the column web panel in shear.

Design inputs for this example

The design code is AS 4100:2020, with section properties from the Australian section database. The yield strength of each part follows its grade and thickness (Table 2.1): 320 MPa for the 10.9 mm flanges of the beam, 280 MPa for the 25 mm column flange, 300 MPa for the 15.7 mm column web, and 250 MPa for the 28 mm end plate.

ItemSymbolValue
Shear (Fy)[mathin] V^{*} [mathin]49 kN
Axial (Fx), compression[mathin] N^{*}_{c} [mathin]15 kN
Major axis moment (Mz)[mathin] M^{*}_{x} [mathin]158 kNm
Beam410 UB 53.7, AS/NZS 3679.1 Gr.300
Depth / web thickness[mathin] d_{bm},\ t_{wb} [mathin]403 mm / 7.6 mm
Flange width / thickness[mathin] b_{fb},\ t_{fb} [mathin]178 mm / 10.9 mm
Root radius / plastic section modulus[mathin] r_{b},\ S_{x} [mathin]11.4 mm / 1.06 x 10⁶ mm³
Yield / tensile strength[mathin] f_{yb},\ f_{ub} [mathin]320 MPa / 440 MPa
Column310 UC 158, AS/NZS 3679.1 Gr.300
Column depth / web thickness[mathin] d_{sup},\ t_{ws} [mathin]327 mm / 15.7 mm
Column flange width / thickness[mathin] b_{fs},\ t_{fs} [mathin]311 mm / 25 mm
Column root radius[mathin] r_{s} [mathin]16.5 mm
Column flange / web yield strength[mathin] f_{ycf},\ f_{ycw} [mathin]280 MPa / 300 MPa
Column tensile strength / elastic modulus[mathin] f_{us},\ E [mathin]440 MPa / 200000 MPa
End plate, bolts and weldsSymbolValue
End platePL 28 x 220 x 624.54, AS/NZS 3678 Gr.250
Plate thickness / width / depth[mathin] t_{i},\ b_{i},\ d_{i} [mathin]28 mm / 220 mm / 624.54 mm
Plate yield / tensile strength[mathin] f_{yi},\ f_{ui} [mathin]250 MPa / 410 MPa
Bolts8 x M24 8.8/TB, threads included in the shear plane
Bolt diameter / minimum tensile strength[mathin] d_{f},\ f_{uf} [mathin]24 mm / 830 MPa
Holes in plate and column flange[mathin] d_{h} [mathin]Nominal, 26 mm
LayoutForm 4E: one row outside and one row inside each flange, 2 bolts per row
Bolt gauge[mathin] s_{g} [mathin]130 mm
Bolt row to flange face[mathin] s_{po} [mathin]65 mm
End plate edge distances (vertical / horizontal)[mathin] a_{e},\ l_{eh\_ep} [mathin]45.77 mm / 45 mm
Flange and web welds8 mm fillets both sides, E49XX, SP
Weld size / weld metal strength[mathin] t_{wf},\ t_{ww},\ f_{uw} [mathin]8 mm / 8 mm / 490 MPa

The end plate depth, 624.54 mm, follows from the beam depth, the 65 mm from each flange face to its outer bolt row, and the 45.77 mm vertical edge distance beyond it.

Step 1: Connection detailing limitations (AS 4100 Clause 9.5)

The bolt layout has to be buildable and match the assumptions behind the capacity equations. For M24 bolts the minimum edge distance is 42 mm, 1.75 times the bolt diameter (Table 9.5.2), and the minimum pitch is 2.5 times the diameter, 60 mm (Clause 9.5.1). The minimum fillet weld size for the parts joined is 6 mm (Table 9.6.3.2). The wrench clearance, flange to bolt row and end plate width limits are the software’s limits for this layout.

Detailing limitLimit (mm)Actual (mm)DCRResult
Minimum bolt gauge60.000130.0000.462PASS
Maximum bolt gauge178.000130.0000.730PASS
Minimum bolt pitch across the tension flange60.000140.9000.426PASS
Minimum vertical edge distance on end plate42.00045.7700.918PASS
Minimum horizontal edge distance on end plate42.00045.0000.933PASS
Minimum horizontal edge distance on column flange42.00090.5000.464PASS
Maximum edge distance150.00045.7700.305PASS
Minimum bolt gauge for wrench clearance73.600130.0000.566PASS
Minimum flange to bolt row distance33.00065.0000.508PASS
Minimum end plate width198.000220.0000.900PASS
Maximum end plate width331.000220.0000.665PASS
Minimum fillet weld size at beam flange to end plate6.0008.0000.750PASS
Minimum fillet weld size at beam web to end plate6.0008.0000.750PASS

For a minimum limit the ratio is limit over actual, and for a maximum it is actual over limit. The governing row is the horizontal edge distance on the end plate:

[math] DCR = \frac{42\ \text{mm}}{45\ \text{mm}} = 0.933 [math]

DCR = 0.933 ≤ 1.0, OK

Step 2: Beam flange welds (AS 4100 Clauses 9.1.4, 9.6.3.10)

Design moment and flange forces

The connection is rigid, so Clause 9.1.4 sets the design moment at not less than half the design section moment capacity of the beam:

[math] M^{*} = \max\left( M^{*}_{x},\ 0.5\, \phi\, f_{yb}\, S_{x} \right) = \max\left( 158\ \text{kNm},\ 0.5 \times 0.9 \times (320\ \text{MPa}) \times (1.06 \times 10^{6}\ \text{mm}^{3}) \right) = \max\left( 158\ \text{kNm},\ 152.64\ \text{kNm} \right) = 158\ \text{kNm} [math]

The 158 kNm from the analysis is above the minimum, so it is used. The flange force from the moment acts over the distance between the flange centres:

[math] N^{*}_{tm} = \frac{M^{*}}{d_{bm} – t_{fb}} = \frac{158\ \text{kNm}}{403\ \text{mm} – 10.9\ \text{mm}} = 402.96\ \text{kN} [math]

The flange welds take the flange force plus half the axial compression:

[math] N^{*}_{fw} = N^{*}_{tm} + 0.5\, N^{*}_{c} = 402.96\ \text{kN} + 0.5 \times (15\ \text{kN}) = 410.46\ \text{kN} [math]

Weld capacity

The welds are Structural Purpose (SP), so the capacity factor is 0.8 from Table 3.4:

[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{wf} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (8\ \text{mm}) = 1.3305\ \text{kN/mm} [math]

The flange welds run along both faces of the flange, less the web and the root radii:

[math] L_{wf} = 2\, b_{fb} – t_{wb} – 2\, r_{b} = 2 \times (178\ \text{mm}) – 7.6\ \text{mm} – 2 \times (11.4\ \text{mm}) = 325.6\ \text{mm} [math]

[math] \phi N_{w} = \phi v_{w}\, L_{wf} = (1.3305\ \text{kN/mm}) \times (325.6\ \text{mm}) = 433.21\ \text{kN} [math]

[math] N^{*}_{fw} = 410.46\ \text{kN} \le \phi N_{w} = 433.21\ \text{kN} [math]

DCR = 410.46 kN / 433.21 kN = 0.947 ≤ 1.0, OK

This is the governing strength check. The flange weld length is fixed by the flange width, so the way to add capacity is a larger fillet or a complete penetration butt weld.

Step 3: Beam web welds in tension (AS 4100 Clauses 7.2, 9.6.3.10)

The web welds on the tension side of the neutral axis are designed to develop the design yield capacity of that part of the web, so that the web can yield before the welds fail. The weld length on the tension side runs from mid-depth to the root radius:

[math] L_{wt} = 0.5\, d_{bm} – t_{fb} – r_{b} = 0.5 \times (403\ \text{mm}) – 10.9\ \text{mm} – 11.4\ \text{mm} = 179.2\ \text{mm} [math]

[math] \phi N_{wt} = \phi\, f_{ywb}\, t_{wb}\, L_{wt} = (0.9) \times (320\ \text{MPa}) \times (7.6\ \text{mm}) \times (179.2\ \text{mm}) = 392.23\ \text{kN} [math]

[math] \phi V_{wt} = 2\, \phi v_{w}\, L_{wt} = 2 \times (1.3305\ \text{kN/mm}) \times (179.2\ \text{mm}) = 476.85\ \text{kN} [math]

DCR = 392.23 kN / 476.85 kN = 0.823 ≤ 1.0, OK

The demand here is the web’s own yield capacity, not a force from the analysis, so the ratio does not change with the loads.

Step 4: Beam web welds in shear (AS 4100 Clauses 9.1.4, 9.6.3.10)

Clause 9.1.4 also sets a minimum design shear: the lesser of 0.15 times the beam shear capacity, [mathin] 0.15 \times 529.25\ \text{kN} [mathin], and 40 kN, which is 40 kN. The 49 kN shear is larger and is used. The web welds on the compression side of the neutral axis carry the shear:

[math] V^{*}_{vw} = V^{*} = 49\ \text{kN}, \qquad L_{wc} = 0.5\, d_{bm} – t_{fb} – r_{b} = 179.2\ \text{mm} [math]

[math] \phi V_{wc} = 2\, \phi v_{w}\, L_{wc} = 2 \times (1.3305\ \text{kN/mm}) \times (179.2\ \text{mm}) = 476.85\ \text{kN} [math]

DCR = 49 kN / 476.85 kN = 0.103 ≤ 1.0, OK

Step 5: Bolts at the tension flange (AS 4100 Clauses 9.1.8, 9.2.2.2, 9.3.2)

In the 4E form, two rows of two bolts take the tension: the row outside the tension flange and the row inside it. Their lever arms are measured to the centre of the compression flange: [mathin] d_{10} = 462.55\ \text{mm} [mathin] for the outer row and [mathin] d_{11} = 321.65\ \text{mm} [mathin] for the inner row, so [mathin] \Sigma d_{i} = 784.2\ \text{mm} [mathin].

The design tension capacity of one bolt, with the tensile stress area [mathin] A_{s} = 353\ \text{mm}^{2} [mathin] and a capacity factor of 0.8:

[math] \phi N_{tf} = \phi\, A_{s}\, f_{uf} = (0.8) \times (353\ \text{mm}^{2}) \times (830\ \text{MPa}) = 234.39\ \text{kN} [math]

The end plate and the column flange are made thick enough to keep the bolts free of prying (Clause 9.1.8, checked in Steps 8 and 11), so every tension bolt reaches its full capacity:

[math] \phi M_{bt} = 2\, \phi N_{tf}\, \Sigma d_{i} = 2 \times (234.39\ \text{kN}) \times (784.2\ \text{mm}) = 367.62\ \text{kNm} [math]

[math] M^{*} = 158\ \text{kNm} \le \phi M_{bt} = 367.62\ \text{kNm} [math]

DCR = 158 kNm / 367.62 kNm = 0.430 ≤ 1.0, OK

Step 6: Bolt group in shear (AS 4100 Clause 9.2.2.1)

The bolts on the compression side of the neutral axis take the shear, so four of the eight bolts are counted. With the threads in the shear plane, the core area is used:

[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, A_{c} = (0.8) \times 0.62 \times (830\ \text{MPa}) \times (324\ \text{mm}^{2}) = 133.38\ \text{kN} [math]

[math] \phi V_{fb} = n_{cw}\, \phi V_{f} = 4 \times (133.38\ \text{kN}) = 533.54\ \text{kN} [math]

DCR = 49 kN / 533.54 kN = 0.092 ≤ 1.0, OK

Step 7: Bolt group in bearing on the end plate and the column flange (AS 4100 Clause 9.2.2.4)

On the end plate the bolt row nearest the edge governs, with [mathin] d_{h} = 26\ \text{mm} [mathin] (Clause 14.3.2):

[math] a_{e1} = a_{e} – \frac{d_{h}}{2} + \frac{d_{f}}{2} = 45.77\ \text{mm} – 13\ \text{mm} + 12\ \text{mm} = 44.77\ \text{mm} [math]

[math] \phi V_{bi} = \phi \min\left( 3.2\, d_{f}\, t_{i}\, f_{ui},\ a_{e1}\, t_{i}\, f_{ui} \right) = (0.9) \times \min\left( 3.2 \times (24)(28)(410),\ (44.77)(28)(410) \right) \times 10^{-3} = 462.56\ \text{kN} [math]

On the column flange the tear-out is to the next hole, with the least pitch from a shear row to the next row [mathin] s_{pv} = 140.9\ \text{mm} [mathin]:

[math] a_{e2} = s_{pv} – d_{h} + \frac{d_{f}}{2} = 140.9\ \text{mm} – 26\ \text{mm} + 12\ \text{mm} = 126.9\ \text{mm} [math]

[math] \phi V_{bc} = \phi \min\left( 3.2\, d_{f}\, t_{fs}\, f_{us},\ a_{e2}\, t_{fs}\, f_{us} \right) = 760.32\ \text{kN} [math]

[math] \phi V_{b} = n_{cw} \min\left( \phi V_{bi},\ \phi V_{bc} \right) = 4 \times (462.56\ \text{kN}) = 1850.3\ \text{kN} [math]

DCR = 49 kN / 1850.3 kN = 0.026 ≤ 1.0, OK

Step 8: End plate in bending (AS 4100 Clauses 9.1.8, 9.3.2)

The end plate bends about yield lines around the tension bolts. Its capacity is the plate’s plastic moment per unit length times a yield line factor for the 4E layout. The effective width in the yield lines and the yield line distance are:

[math] b_{i,e} = \min\left( b_{i},\ b_{fb} + 25\ \text{mm} \right) = \min\left( 220\ \text{mm},\ 203\ \text{mm} \right) = 203\ \text{mm}, \qquad a_{h} = 0.5 \sqrt{b_{i,e}\, s_{g}} = 0.5 \sqrt{(203)(130)}\ \text{mm} = 81.225\ \text{mm} [math]

The inner bolt row is taken at not more than the yield line distance from the flange, [mathin] s_{pi} = \min(s_{po},\ a_{h}) = 65\ \text{mm} [mathin]:

[math] Y_{p} = 0.5\, b_{i,e} \left[ d_{11} \left( \frac{1}{s_{pi}} + \frac{1}{a_{h}} \right) + \frac{d_{10}}{s_{po}} – 0.5 \right] + \frac{2}{s_{g}}\, d_{11} \left( s_{pi} + a_{h} \right) [math]

[math] Y_{p} = 2299.3\ \text{mm}, \qquad \phi M_{pt} = \phi\, f_{yi}\, t_{i}^{2}\, Y_{p} = (0.9) \times (250\ \text{MPa}) \times (28\ \text{mm})^{2} \times (2299.3\ \text{mm}) = 405.6\ \text{kNm} [math]

To keep the bolts free of prying, the plate is made at least 1.11 times as strong as the tension bolts, or as the beam (Clause 9.1.8). The beam’s design section moment capacity is [mathin] \phi M_{s} = \phi\, f_{yb}\, S_{x} = 305.28\ \text{kNm} [mathin]:

[math] M^{*}_{p} = \min\left( 1.11\, \phi M_{bt},\ 1.11\, \phi M_{s} \right) = \min\left( 1.11 \times 367.62,\ 1.11 \times 305.28 \right)\ \text{kNm} = 338.86\ \text{kNm} [math]

DCR = 338.86 kNm / 405.6 kNm = 0.835 ≤ 1.0, OK

This required capacity does not depend on the applied moment. It makes sure the plate stays thick enough for the bolts to reach their full tension without prying.

Step 9: End plate extension in shear yield

The tension flange force at the end plate is the flange force from the moment, [mathin] N^{*}_{ft} = N^{*}_{tm} = 402.96\ \text{kN} [mathin].

Two bolt rows share it, so the extension of the plate beyond the flange carries half of it as shear:

[math] V^{*}_{p} = \frac{N^{*}_{ft}}{n_{bp}} = \frac{402.96\ \text{kN}}{2} = 201.48\ \text{kN} [math]

[math] \phi V_{pe} = \phi\, 0.5\, f_{yi}\, b_{i}\, t_{i} = (0.9) \times 0.5 \times (250\ \text{MPa}) \times (220\ \text{mm}) \times (28\ \text{mm}) = 693\ \text{kN} [math]

DCR = 201.48 kN / 693 kN = 0.291 ≤ 1.0, OK

Step 10: End plate extension in shear rupture

The net section of the extension through the two bolt holes:

[math] \phi V_{pu} = \phi\, 0.6\, f_{ui} \left( b_{i} – 2\, d_{h} \right) t_{i} = (0.9) \times 0.6 \times (410\ \text{MPa}) \times (220\ \text{mm} – 52\ \text{mm}) \times (28\ \text{mm}) = 1041.5\ \text{kN} [math]

DCR = 201.48 kN / 1041.5 kN = 0.193 ≤ 1.0, OK

Step 11: Column flange in bending at the tension flange (AS 4100 Clause 9.1.8)

The column flange behind the tension bolts bends about its own yield lines. The column continues past the connection and is unstiffened. The yield line distance and the pitch of the bolt rows across the tension flange are:

[math] a_{hc} = 0.5 \sqrt{b_{fs}\, s_{g}} = 0.5 \sqrt{(311)(130)}\ \text{mm} = 100.54\ \text{mm}, \qquad s_{p2} = 2\, s_{po} + t_{fb}’ = 2 \times (65\ \text{mm}) + 10.9\ \text{mm} = 140.9\ \text{mm} [math]

[math] Y_{c} = 0.5\, b_{fs} \left[ \frac{d_{11}}{a_{hc}} + \frac{d_{10}}{a_{hc}} \right] + \frac{2}{s_{g}} \left[ d_{11} \left( a_{hc} + 0.75\, s_{p2} \right) + d_{10} \left( a_{hc} + 0.25\, s_{p2} \right) + 0.5\, s_{p2}^{2} \right] + 0.5\, s_{g} [math]

[math] Y_{c} = 3417.2\ \text{mm}, \qquad \phi M_{ct} = \phi\, f_{ycf}\, t_{fs}^{2}\, Y_{c} = (0.9) \times (280\ \text{MPa}) \times (25\ \text{mm})^{2} \times (3417.2\ \text{mm}) = 538.2\ \text{kNm} [math]

The column flange has to meet the same 1.11 requirement as the end plate, so that the bolts stay free of prying:

DCR = 338.86 kNm / 538.2 kNm = 0.630 ≤ 1.0, OK

Step 12: Column web yield at the tension flange

The tension flange force spreads through the end plate and the column flange into the column web. The stiff bearing length at the column face is the flange plus the two fillet welds, and the column flange plus root radius sets the dispersion:

[math] b_{sc} = t_{fb} + 2\, t_{wf} = 10.9\ \text{mm} + 2 \times (8\ \text{mm}) = 26.9\ \text{mm}, \qquad k_{c} = t_{fs} + r_{s} = 25\ \text{mm} + 16.5\ \text{mm} = 41.5\ \text{mm} [math]

[math] \phi R_{wt} = \phi \left( b_{sc} + 2\, t_{i} + 6\, k_{c} \right) t_{ws}\, f_{ycw} = (0.9) \times (26.9 + 56 + 249)\ \text{mm} \times (15.7\ \text{mm}) \times (300\ \text{MPa}) = 1406.9\ \text{kN} [math]

DCR = 402.96 kN / 1406.9 kN = 0.286 ≤ 1.0, OK

Step 13: Column web bearing yield at the compression flange (AS 4100 Clause 5.13.3)

[math] N^{*}_{fc} = N^{*}_{tm} + 0.5\, N^{*}_{c} = 402.96\ \text{kN} + 0.5 \times (15\ \text{kN}) = 410.46\ \text{kN} [math]

The bearing length at the web is dispersed 1:2.5 through the end plate and the column flange:

[math] b_{bf} = b_{sc} + 5\, t_{i} + 5\, t_{fs} = 26.9\ \text{mm} + 5 \times (28\ \text{mm}) + 5 \times (25\ \text{mm}) = 291.9\ \text{mm} [math]

[math] \phi R_{by} = \phi\, 1.25\, b_{bf}\, t_{ws}\, f_{ycw} = (0.9) \times 1.25 \times (291.9\ \text{mm}) \times (15.7\ \text{mm}) \times (300\ \text{MPa}) = 1546.7\ \text{kN} [math]

DCR = 410.46 kN / 1546.7 kN = 0.265 ≤ 1.0, OK

Step 14: Column web crippling at the compression flange

AS 4100 has no web crippling clause. The software uses the crippling capacity of a web under a concentrated load more than half the column depth from the column end, with [mathin] \phi = 0.75 [mathin]:

[math] \phi R_{wc} = \phi\, 0.8\, t_{ws}^{2} \left[ 1 + 3 \frac{b_{sc}}{d_{sup}} \left( \frac{t_{ws}}{t_{fs}} \right)^{1.5} \right] \sqrt{\frac{E\, f_{ycw}\, t_{fs}}{t_{ws}}} = 1623.1\ \text{kN} [math]

DCR = 410.46 kN / 1623.1 kN = 0.253 ≤ 1.0, OK

Step 15: Column web bearing buckling at the compression flange (AS 4100 Clauses 5.13.4, 6.3.3)

The web is taken as a compression member over its clear depth [mathin] d_{1} = d_{sup} – 2\, t_{fs} = 277\ \text{mm} [mathin] (Clause 5.10.1), with the bearing length dispersed 1:1 to the web centreline each side:

[math] b_{b} = b_{bf} + d_{1} = 291.9\ \text{mm} + 277\ \text{mm} = 568.9\ \text{mm}, \qquad A_{w} = b_{b}\, t_{ws} = 8931.7\ \text{mm}^{2} [math]

With [mathin] k_{f} = 1 [mathin] and [mathin] \alpha_{b} = 0.5 [mathin] (Table 6.3.3(A)), the column curve of Clause 6.3.3 gives:

[math] \lambda_{n} = \frac{2.5\, d_{1}}{t_{ws}} \sqrt{k_{f}} \sqrt{\frac{f_{ycw}}{250}} = 48.318, \qquad \alpha_{a} = \frac{2100 (\lambda_{n} – 13.5)}{\lambda_{n}^{2} – 15.3\, \lambda_{n} + 2050} = 20.058 [math]

[math] \lambda = \lambda_{n} + \alpha_{a} \alpha_{b} = 58.347, \qquad \eta = 0.00326 (\lambda – 13.5) = 0.1462, \qquad \xi = \frac{(\lambda/90)^{2} + 1 + \eta}{2 (\lambda/90)^{2}} = 1.8636 [math]

[math] \alpha_{c} = \xi \left[ 1 – \sqrt{1 – \left( \frac{90}{\xi \lambda} \right)^{2}} \right] = 0.81781 [math]

[math] \phi R_{bb} = \phi\, \alpha_{c}\, k_{f}\, A_{w}\, f_{ycw} = (0.9) \times (0.81781) \times (1) \times (8931.7\ \text{mm}^{2}) \times (300\ \text{MPa}) = 1972.2\ \text{kN} [math]

DCR = 410.46 kN / 1972.2 kN = 0.208 ≤ 1.0, OK

Step 16: Column web panel in shear (AS 4100 Clauses 5.11.2, 5.11.4)

The connection is one-sided, so the column web panel takes the larger flange force as shear, with the column shear taken as zero:

[math] V^{*}_{c} = \max\left( N^{*}_{ft},\ N^{*}_{fc} \right) = \max\left( 402.96\ \text{kN},\ 410.46\ \text{kN} \right) = 410.46\ \text{kN} [math]

[math] \frac{d_{1}}{t_{ws}} \sqrt{\frac{f_{ycw}}{250}} = 19.327 \le 82, \qquad A_{w} = d_{sup}\, t_{ws} = 5133.9\ \text{mm}^{2} [math]

The web is not slender, so it reaches shear yield ([mathin] \alpha_{v} = 1 [mathin]):

[math] \phi V_{c} = \phi\, 0.6\, \alpha_{v}\, f_{ycw}\, A_{w} = (0.9) \times 0.6 \times (1) \times (300\ \text{MPa}) \times (5133.9\ \text{mm}^{2}) = 831.69\ \text{kN} [math]

DCR = 410.46 kN / 831.69 kN = 0.494 ≤ 1.0, OK

Summary of checks

Design checkDesign action effectDesign capacityDCRResult
Connection detailing limitations42 mm45 mm0.933PASS
Beam flange welds410.46 kN433.21 kN0.947PASS
Beam web welds in tension392.23 kN476.85 kN0.823PASS
Beam web welds in shear49 kN476.85 kN0.103PASS
Bolts at the tension flange158 kNm367.62 kNm0.430PASS
Bolt group in shear49 kN533.54 kN0.092PASS
Bolt group in bearing on end plate and column flange49 kN1850.3 kN0.026PASS
End plate in bending338.86 kNm405.6 kNm0.835PASS
End plate extension, shear yield201.48 kN693 kN0.291PASS
End plate extension, shear rupture201.48 kN1041.5 kN0.193PASS
Column flange in bending at the tension flange338.86 kNm538.2 kNm0.630PASS
Column web yield at the tension flange402.96 kN1406.9 kN0.286PASS
Column web bearing yield at the compression flange410.46 kN1546.7 kN0.265PASS
Column web crippling at the compression flange410.46 kN1623.1 kN0.253PASS
Column web bearing buckling at the compression flange410.46 kN1972.2 kN0.208PASS
Column web panel in shear410.46 kN831.69 kN0.494PASS

The connection passes every check. The beam flange welds govern at 0.947, followed by the end plate in bending at 0.835 and the web welds in tension at 0.823. The last two are set by the capacities of the beam and the bolts, not by the applied loads. The column passes all its local checks without stiffeners, with the web panel in shear highest at 0.494.

What to change if a check fails

  • Detailing limits: adjust the gauge, the bolt rows’ distance from the flanges or the plate edge distances to the limits in Step 1.
  • Flange welds: increase the fillet size. The weld length is fixed by the beam flange.
  • Web welds: increase the web fillet size. The web weld in tension is designed for the web’s own yield capacity.
  • Tension bolts: use a larger bolt, or a stiffened or eight-bolt layout where the module offers one.
  • End plate in bending or extension shear: use a thicker end plate, or a higher grade.
  • Column flange in bending: use a heavier column, with a thicker flange.
  • Column web checks: use a heavier column.

Frequently asked questions

Why are the end plate and column flange checked against 338.86 kNm and not 158 kNm?

Clause 9.1.8 lets the bolts be designed without prying forces only if the plies are stiff enough. The software makes the end plate and the column flange at least 1.11 times as strong as the tension bolts, or as the beam, whichever is less. Here that is 1.11 x 305.28 kNm = 338.86 kNm, so the result does not depend on the applied moment.

Was the Clause 9.1.4 minimum moment used?

No. The minimum for a rigid connection is half the design section moment capacity of the beam, 0.5 x 0.9 x 320 MPa x 1.06 x 10⁶ mm³ = 152.64 kNm. The 158 kNm from the analysis is larger, so it is the design moment.

Why are only four bolts counted for shear?

The bolts on the tension side of the neutral axis are already loaded to their full tension capacity in Step 5. The shear is taken by the four bolts on the compression side, where the plate bears against the column.

Why is the column web yield stress 300 MPa when the flange is 280 MPa?

AS 4100 Table 2.1 gives the yield stress by grade and thickness. The 310 UC 158 has a 25 mm flange and a 15.7 mm web, so its web, being thinner, has the higher yield stress. The column web checks use 300 MPa, and the column flange bending check uses 280 MPa.

Is there a column web crippling clause in AS 4100?

No. The software uses the crippling capacity of a web under a concentrated load more than half the column depth from the column end, with a capacity factor of 0.75. It is well clear of governing in this example.

Design an extended end plate moment connection for free

Every number on this page comes from one solve. Pick AS 4100:2020 and the extended end plate connection, enter your beam, column, plate, bolts and loads, and see each of these checks in your browser. There is nothing to install.

The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every design capacity and DCR, for AS 4100:2020 shear connections, moment connections and splices. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.