SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

Single Angle Cleat Connection Design to AS 4100

To design a single angle cleat connection to AS 4100, you check both legs of the angle separately: the outstanding leg bolted to the support, and the leg bolted to the beam web. Each leg has its own bolt group in shear and bearing, both loaded eccentrically, and the angle is checked in shear, bending and block shear at each leg. Then the beam is checked in shear at the connection.

This page works through one example from start to finish: an uncoped 460 UB 82.1 beam framing into the flange of a 310 UC 158 column through one 100×6 equal angle, 300 mm long, with a design shear of 150 kN and M20 8.8/S bolts, designed to AS 4100:2020. Every equation is written out with its numbers, in the same order as the calculation report that the SkyCiv Connection Design module produces for it. It uses the same beam, column and design shear as the web side plate example, and the same angle size as the double angle cleat example. The scope and conventions of the AS 4100 module are on the design of steel connections using AS 4100:2020 page.

What is a single angle cleat connection?

A single angle cleat connection is one angle, bolted to the beam web through one leg and to the supporting member through the other. It is a simple connection: the angle is thin and bolted on both legs, so the beam end can rotate and the joint carries the end shear with almost no moment. With an angle on one side only, it is quick to fit, and it is useful where there is no room for a second cleat on the other side of the web.

The report names the legs by their position. The NSL (near side leg) is the leg against the beam web, and the OSL (outstanding leg) is the leg against the support. In this example both legs are 100 mm wide, and each has one line of four bolts at 75 mm pitch. In the AS 4100 module this connection sits beside the web side plate, the flexible end plate and the double angle cleat.

Single angle cleat elevation: 460 UB 82.1 bolted through one 100x6 EA angle to a 310 UC 158 column flange

Elevation of the example connection. The beam stops 12 mm short of the column flange; four bolts in each leg at 75 mm pitch.

Section A-A: one 100x6 EA angle on the beam web, four M20 8.8/S bolts at 75 mm pitch in the outstanding leg

Section A-A, looking at the outstanding leg. Four bolts at 75 mm pitch, 60 mm from the centreline of the beam web.

SkyCiv Connection Design Assembly tab: single angle 100x6 EA, 300 mm long, AS/NZS 3679.1 Gr.300, shown in the 3D view

The same connection in SkyCiv Connection Design, with the angle selected on the Assembly tab.

Single angle connection design: the steps at a glance

  1. Check the connection detailing limits at the outstanding leg (OSL).
  2. Check the bolt group in shear at the OSL, by the instantaneous centre of rotation.
  3. Check the bolt group in bearing on the angle and the column flange at the OSL.
  4. Check the angle in shear, bending and block shear at the OSL.
  5. Check the connection detailing limits at the near side leg (NSL).
  6. Check the bolt group in shear at the NSL.
  7. Check the bolt group in bearing on the angle and the beam web at the NSL.
  8. Check the angle in shear, bending and block shear at the NSL.
  9. Check the beam in shear.

Design inputs for this example

The design code is AS 4100:2020, with section properties from the Australian section database. The yield strength of each part follows its grade and thickness: 300 MPa for the beam, 280 MPa for the column with its 25 mm flange, and 320 MPa for the 6 mm angle.

ItemSymbolValue
Design shear (design action effect)[mathin] V^{*} [mathin]150 kN
Beam460 UB 82.1, AS/NZS 3679.1 Gr.300, uncoped
Beam depth / web thickness[mathin] d_{bm},\ t_{wb} [mathin]460 mm / 9.9 mm
Beam yield / tensile strength[mathin] f_{yb},\ f_{ub} [mathin]300 MPa / 440 MPa
Column310 UC 158, AS/NZS 3679.1 Gr.300
Column flange width / thickness[mathin] b_{fs},\ t_{fs} [mathin]311 mm / 25 mm
Column yield / tensile strength[mathin] f_{ys},\ f_{us} [mathin]280 MPa / 440 MPa
ItemSymbolValue
Angle cleat100×6 EA, AS/NZS 3679.1 Gr.300
Angle length (depth) / thickness[mathin] d_{i},\ t_{i} [mathin]300 mm / 6 mm
Leg widths at beam (NSL) / column (OSL)[mathin] b_{iNSL},\ b_{iOSL} [mathin]100 mm / 100 mm
Angle yield / tensile strength[mathin] f_{ya},\ f_{ua} [mathin]320 MPa / 440 MPa
BoltsM20 8.8/S, threads included in the shear plane
Bolt diameter / minimum tensile strength[mathin] d_{fw},\ f_{uf} [mathin]20 mm / 830 MPa
Holes in angle, beam web and column flange[mathin] d_{h} [mathin]Nominal, 22 mm
Beam end clearance to column flange[mathin] clr [mathin]12 mm
GeometryAt beam web (NSL)At column flange (OSL)
Bolt rows / row pitch4 / 75 mm4 / 75 mm
Bolt columns11
Gauge[mathin] g_{1} = 62\ \text{mm} [mathin] from the column face[mathin] g_{2} = 55.05\ \text{mm} [mathin] from the heel
Vertical edge distance on angle[mathin] l_{ev\_NSL} = 37.5\ \text{mm} [mathin][mathin] l_{ev\_OSL} = 37.5\ \text{mm} [mathin]
Bolt eccentricity[mathin] e_{b} = 62\ \text{mm} [mathin][mathin] e_{b} = 60\ \text{mm} [mathin]

The gauge at the OSL is measured from the heel of the angle. Adding half the beam web thickness gives the distance from the centreline of the web to the bolts, 55.05 + 4.95 = 60 mm, which is the bolt gauge on the column flange in Step 1 and the 60 mm bolt eccentricity at the OSL. The horizontal edge on the outstanding leg is 100 – 55.05 = 44.95 mm. At the beam web, the 62 mm gauge from the column face leaves 100 – 62 = 38 mm to the toe of the angle, and 62 – 12 = 50 mm to the end of the beam.

Design shear (AS 4100 Clause 9.1.4)

AS 4100 Clause 9.1.4 sets a minimum design action for a simple connection. The design shear is not taken less than the lesser of 0.15 times the design shear capacity of the uncoped beam (Clause 5.11.2) and 40 kN:

[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (460\ \text{mm}) \times (9.9\ \text{mm}) = 737.75\ \text{kN} [math]

[math] V^{*}_{min} = \min\left( 0.15\, \phi V_{vo},\ 40\ \text{kN} \right) = \min\left( 0.15 \times (737.75\ \text{kN}),\ 40\ \text{kN} \right) = 40\ \text{kN} [math]

[math] V^{*} = \max\left( V^{*},\ V^{*}_{min} \right) = \max\left( 150\ \text{kN},\ 40\ \text{kN} \right) = 150\ \text{kN} [math]

The 150 kN entered is above the minimum, so it is the design action effect for every check below.

Step 1: Connection detailing limitations at the OSL (AS 4100 Clause 9.5)

The minimum pitch is [mathin] 2.5\, d_{f} = 2.5 \times 20\ \text{mm} = 50\ \text{mm} [mathin] (Clause 9.5.1). The minimum edge distance for an M20 bolt is 35 mm, [mathin] 1.75\, d_{f} [mathin] from Table 9.5.2. The maximum edge distance is 12 times the angle thickness, [mathin] 12 \times 6\ \text{mm} = 72\ \text{mm} [mathin]. The 124 mm maximum pitch and the 44.35 mm minimum bolt gauge on the column flange are the limits the module applies for this angle and support. The edge on the column flange is [mathin] 311 / 2 – 60 = 95.5\ \text{mm} [mathin].

Detailing limit (OSL)Limit (mm)Actual (mm)DCRResult
Minimum bolt row pitch50.00075.0000.667PASS
Maximum bolt row pitch124.00075.0000.605PASS
Minimum vertical edge distance on angle35.00037.5000.933PASS
Minimum horizontal edge distance on angle35.00044.9500.779PASS
Minimum horizontal edge distance on column flange35.00095.5000.366PASS
Minimum bolt gauge on column flange44.35060.0000.739PASS
Maximum edge distance72.00044.9500.624PASS

For a minimum limit the ratio is limit over actual, and for a maximum it is actual over limit. The governing row is the vertical edge distance at the top and bottom of the 300 mm angle:

[math] DCR = \frac{35\ \text{mm}}{37.5\ \text{mm}} = 0.93333 [math]

DCR = 0.933 ≤ 1.0, OK

This is the highest ratio in the report, but it is a detailing limit, not a strength check: the 37.5 mm end distances are only 2.5 mm above the minimum.

Step 2: Bolt group in shear at the OSL (AS 4100 Clauses 9.2.2.1, 9.3.1)

The four bolts in the outstanding leg take the design shear 60 mm away from their line, so the group carries a moment as well as the shear. Clause 9.3.1 allows the bolt forces to be found by an analysis of the group, and the module uses the instantaneous centre of rotation (ICOR) method, which turns the eccentric group into a bolt group coefficient C.

Design shear capacity of one bolt

The threads are in the single shear plane, so the core area is used: [mathin] n_{n} = 1,\ A_{c} = 225\ \text{mm}^{2} [mathin] and [mathin] n_{x} = 0 [mathin]. The capacity factor for a bolt in shear is 0.8, and the reduction factors [mathin] k_{rd} [mathin] and [mathin] k_{r,bolt} [mathin] are both 1:

[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, k_{rd}\, k_{r,bolt}\, \left( n_{n} A_{c} + n_{x} A_{o} \right) [math]

[math] \phi V_{f} = (0.8) \times 0.62 \times (830\ \text{MPa}) \times (1) \times (1) \times \left( (1)(225\ \text{mm}^{2}) + (0)(314.16\ \text{mm}^{2}) \right) = 92.628\ \text{kN} [math]

Locating the instantaneous centre

Bolt 1 is at the bottom of the line. The instantaneous centre is found by iteration, as described on the AS 4100 module page.

Boltx (mm)y (mm)
10.000.00
20.0075.00
30.00150.00
40.00225.00

The iteration converges with the instantaneous centre, measured from bolt 1, at:

[math] x_{ic} = -103.32\ \text{mm}, \qquad y_{ic} = 112.5\ \text{mm} [math]

The bolt reactions at that point are:

BoltR (kN)Rx (kN)Ry (kN)Mn (kN-mm)
190.9166.9661.5013886.64
288.1330.0782.849686.28
388.13-30.0782.849686.28
490.91-66.9661.5013886.64

Bolt group capacity

The reactions give a bolt group coefficient of C = 3.12, so the eccentric group of four bolts works like 3.12 bolts loaded directly:

[math] \phi V_{df} = \phi V_{f}\, C = (92.628\ \text{kN}) \times (3.12) = 289\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{df} = 289\ \text{kN} [math]

DCR = 150 kN / 289 kN = 0.519 ≤ 1.0, OK

Step 3: Bolt group in bearing at the OSL (AS 4100 Clause 9.2.2.4)

Each bolt bears on its hole in the angle and in the column flange. A ply can fail by crushing at the hole, capped at [mathin] 3.2\, d_{fw}\, t_{p}\, f_{up} [mathin], or by tearing out to an edge or to the next hole, which depends on [mathin] a_{e} [mathin]. Under ICOR the bolt forces act in different directions, so the least distance in any direction governs each ply.

Bearing on the angle

[math] a_{e1} = l_{ev\_OSL} – 0.5\, d_{h} + 0.5\, d_{fw} = (37.5\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 36.5\ \text{mm} [math]

[math] a_{e2} = s_{p} – d_{h} + 0.5\, d_{fw} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

[math] a_{e3} = l_{eh\_OSL} – 0.5\, d_{h} + 0.5\, d_{fw} = (44.95\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 43.95\ \text{mm} [math]

[math] a_{e} = \min\left( 36.5,\ 63,\ 43.95 \right)\ \text{mm} = 36.5\ \text{mm} [math]

The capacity factor for a ply in bearing is 0.9:

[math] \phi V_{b} = \phi \min\left( 3.2\, d_{fw}\, t_{i}\, f_{ua},\ a_{e}\, t_{i}\, f_{ua} \right) [math]

[math] \phi V_{b,pl} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (6\ \text{mm}) \times (440\ \text{MPa}),\ (36.5\ \text{mm}) \times (6\ \text{mm}) \times (440\ \text{MPa}) \right) = 86.724\ \text{kN} [math]

Bearing on the column flange

[math] a_{e4} = s_{p} – d_{h} + 0.5\, d_{fw} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

[math] a_{e5} = l_{eh\_fs} – 0.5\, d_{h} + 0.5\, d_{fw} = (95.5\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 94.5\ \text{mm} [math]

[math] \phi V_{b,sup} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (25\ \text{mm}) \times (440\ \text{MPa}),\ (63\ \text{mm}) \times (25\ \text{mm}) \times (440\ \text{MPa}) \right) = 623.7\ \text{kN} [math]

Bolt group bearing capacity

The weaker ply per bolt, scaled by the bolt group coefficient from Step 2:

[math] \phi V_{b} = \min\left( \phi V_{b,pl},\ \phi V_{b,sup} \right) C = \min\left( 86.724\ \text{kN},\ 623.7\ \text{kN} \right) \times (3.12) = 270.58\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{b} = 270.58\ \text{kN} [math]

DCR = 150 kN / 270.58 kN = 0.554 ≤ 1.0, OK

The 6 mm angle is the weak ply, by a wide margin over the 25 mm column flange, and its 37.5 mm end distance sets the tear-out capacity.

Step 4: Angle in shear at the OSL (AS 4100 Clause 5.11.3)

The full design shear passes down the leg of the angle as vertical shear. The leg is a rectangle, so Clause 5.11.3 gives 0.5 fy on the gross area:

[math] \phi V_{v} = \phi\, 0.5\, f_{ya}\, d_{i}\, t_{i} [math]

[math] \phi V_{v} = (0.9) \times 0.5 \times (320\ \text{MPa}) \times (300\ \text{mm}) \times (6\ \text{mm}) = 259.2\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{v} = 259.2\ \text{kN} [math]

DCR = 150 kN / 259.2 kN = 0.579 ≤ 1.0, OK

This is the governing strength check of the connection, tied with the same check at the NSL in Step 10. One 6 mm angle carries all the shear, so gross shear in the leg comes before any bolt check.

Step 5: Angle in bending at the OSL (AS 4100 Clause 5.2.1)

The design shear acts 60 mm from the bolt line, so the leg bends about its strong axis. The design section moment capacity of the leg, using its plastic section modulus:

[math] \phi M_{s} = \phi\, \frac{f_{ya}\, t_{i}\, d_{i}^{2}}{4} [math]

[math] \phi M_{s} = (0.9) \times \frac{(320\ \text{MPa}) \times (6\ \text{mm}) \times (300\ \text{mm})^{2}}{4} = 38.88\ \text{kNm} [math]

Expressed as the shear it can carry at the bolt eccentricity:

[math] \phi V_{n} = \frac{\phi M_{s}}{e_{b}} = \frac{38.88\ \text{kNm}}{60\ \text{mm}} = 648\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{n} = 648\ \text{kN} [math]

DCR = 150 kN / 648 kN = 0.231 ≤ 1.0, OK

Step 6: Angle in block shear at the OSL (AS 4100 Clause 9.1.9)

A block of the outstanding leg can tear out: shear down the bolt line to the bottom of the angle, plus tension across to the free edge of the leg.

[math] A_{nt} = \left[ l_{eh\_OSL} – 0.5\, d_{h} \right] t_{i} = \left[ (44.95\ \text{mm}) – 0.5 \times (22\ \text{mm}) \right] \times (6\ \text{mm}) = 203.7\ \text{mm}^{2} [math]

[math] A_{gv} = \left[ l_{ev\_OSL} + (n_{p} – 1)\, s_{p} \right] t_{i} = \left[ (37.5\ \text{mm}) + (4 – 1)(75\ \text{mm}) \right] \times (6\ \text{mm}) = 1575\ \text{mm}^{2} [math]

[math] A_{nv} = \left[ l_{ev\_OSL} + (n_{p} – 1)\, s_{p} – (n_{p} – 0.5)\, d_{h} \right] t_{i} = \left[ (262.5\ \text{mm}) – (3.5)(22\ \text{mm}) \right] \times (6\ \text{mm}) = 1113\ \text{mm}^{2} [math]

The tension stress is uniform, so [mathin] k_{bs} = 1 [mathin], and the capacity factor for block shear is 0.75:

[math] \phi R_{bs} = \phi \min\left( 0.6\, f_{ua}\, A_{nv} + k_{bs}\, f_{ua}\, A_{nt},\ 0.6\, f_{ya}\, A_{gv} + k_{bs}\, f_{ua}\, A_{nt} \right) [math]

[math] \phi R_{bs} = (0.75) \times \min\left( 0.6 \times (440)(1113) + (1)(440)(203.7),\ 0.6 \times (320)(1575) + (1)(440)(203.7) \right) \times 10^{-3} = 287.6\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi R_{bs} = 287.6\ \text{kN} [math]

DCR = 150 kN / 287.6 kN = 0.522 ≤ 1.0, OK

Step 7: Connection detailing limitations at the NSL (AS 4100 Clause 9.5)

The same pitch and edge limits apply to the leg on the beam web. The angle depth is also checked against the 230 mm minimum and the 405.2 mm maximum the module applies for this beam.

Detailing limit (NSL)Limit (mm)Actual (mm)DCRResult
Minimum bolt row pitch50.00075.0000.667PASS
Maximum bolt row pitch124.00075.0000.605PASS
Minimum vertical edge distance on angle35.00037.5000.933PASS
Minimum horizontal edge distance on angle35.00038.0000.921PASS
Minimum horizontal edge distance on beam web35.00050.0000.700PASS
Minimum angle depth230.000300.0000.767PASS
Maximum angle depth405.200300.0000.740PASS
Maximum edge distance72.00050.0000.694PASS

The governing row is again the 37.5 mm vertical edge distance on the angle:

[math] DCR = \frac{35\ \text{mm}}{37.5\ \text{mm}} = 0.93333 [math]

DCR = 0.933 ≤ 1.0, OK

Step 8: Bolt group in shear at the NSL (AS 4100 Clauses 9.2.2.1, 9.3.1)

The four bolts in the beam web are in single shear through the angle and the web, with the same 92.628 kN capacity as Step 2. They are 62 mm from the column face, so the group is loaded eccentrically and ICOR is used again, with the same bolt coordinates as Step 2.

[math] x_{ic} = -99.375\ \text{mm}, \qquad y_{ic} = 112.5\ \text{mm} [math]

BoltR (kN)Rx (kN)Ry (kN)Mn (kN-mm)
190.9168.1460.1913646.66
287.9431.0582.289340.66
387.94-31.0582.289340.66
490.91-68.1460.1913646.66

The reactions give C = 3.08 for the four bolts:

[math] \phi V_{df} = \phi V_{f}\, C = (92.628\ \text{kN}) \times (3.08) = 285.29\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{df} = 285.29\ \text{kN} [math]

DCR = 150 kN / 285.29 kN = 0.526 ≤ 1.0, OK

The 2 mm larger eccentricity at the beam web gives a slightly lower coefficient than the 3.12 at the column.

Step 9: Bolt group in bearing at the NSL (AS 4100 Clause 9.2.2.4)

Bearing on the angle

[math] a_{e1} = l_{ev\_NSL} – 0.5\, d_{h} + 0.5\, d_{fw} = (37.5\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 36.5\ \text{mm} [math]

[math] a_{e2} = s_{p} – d_{h} + 0.5\, d_{fw} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

[math] a_{e3} = l_{eh\_NSL} – 0.5\, d_{h} + 0.5\, d_{fw} = (38\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 37\ \text{mm} [math]

[math] \phi V_{b,pl} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (6\ \text{mm}) \times (440\ \text{MPa}),\ (36.5\ \text{mm}) \times (6\ \text{mm}) \times (440\ \text{MPa}) \right) = 86.724\ \text{kN} [math]

Bearing on the beam web

[math] a_{e4} = s_{p} – d_{h} + 0.5\, d_{fw} = 63\ \text{mm}, \qquad a_{e5} = l_{eh\_w} – 0.5\, d_{h} + 0.5\, d_{fw} = (50\ \text{mm}) – 11\ \text{mm} + 10\ \text{mm} = 49\ \text{mm} [math]

[math] \phi V_{b,beam} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (9.9\ \text{mm}) \times (440\ \text{MPa}),\ (49\ \text{mm}) \times (9.9\ \text{mm}) \times (440\ \text{MPa}) \right) = 192.1\ \text{kN} [math]

Bolt group bearing capacity

[math] \phi V_{b} = \min\left( \phi V_{b,pl},\ \phi V_{b,beam} \right) C = \min\left( 86.724\ \text{kN},\ 192.1\ \text{kN} \right) \times (3.08) = 267.11\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{b} = 267.11\ \text{kN} [math]

DCR = 150 kN / 267.11 kN = 0.562 ≤ 1.0, OK

Step 10: Angle in shear at the NSL (AS 4100 Clause 5.11.3)

The leg on the beam web has the same depth and thickness as the outstanding leg, so the shear capacity is the same:

[math] \phi V_{v} = \phi\, 0.5\, f_{ya}\, d_{i}\, t_{i} = (0.9) \times 0.5 \times (320\ \text{MPa}) \times (300\ \text{mm}) \times (6\ \text{mm}) = 259.2\ \text{kN} [math]

DCR = 150 kN / 259.2 kN = 0.579 ≤ 1.0, OK

Step 11: Angle in bending at the NSL (AS 4100 Clause 5.2.1)

At the beam web the lever arm is the 62 mm bolt eccentricity:

[math] \phi V_{n} = \frac{\phi M_{s}}{e_{b}} = \frac{38.88\ \text{kNm}}{62\ \text{mm}} = 627.1\ \text{kN} [math]

DCR = 150 kN / 627.1 kN = 0.239 ≤ 1.0, OK

Step 12: Angle in block shear at the NSL (AS 4100 Clause 9.1.9)

[math] A_{nt} = \left[ l_{eh\_NSL} – 0.5\, d_{h} \right] t_{i} = \left[ (38\ \text{mm}) – 0.5 \times (22\ \text{mm}) \right] \times (6\ \text{mm}) = 162\ \text{mm}^{2} [math]

[math] A_{gv} = \left[ (37.5\ \text{mm}) + (4 – 1)(75\ \text{mm}) \right] \times (6\ \text{mm}) = 1575\ \text{mm}^{2}, \qquad A_{nv} = \left[ (262.5\ \text{mm}) – (3.5)(22\ \text{mm}) \right] \times (6\ \text{mm}) = 1113\ \text{mm}^{2} [math]

[math] \phi R_{bs} = (0.75) \times \min\left( 0.6 \times (440)(1113) + (1)(440)(162),\ 0.6 \times (320)(1575) + (1)(440)(162) \right) \times 10^{-3} = 273.83\ \text{kN} [math]

DCR = 150 kN / 273.83 kN = 0.548 ≤ 1.0, OK

Step 13: Supported member in shear (AS 4100 Clause 5.11.2)

The beam is uncoped, so its full web carries the shear. Clause 5.11.2 allows the uniform shear capacity when the web is stocky enough not to buckle in shear:

[math] \frac{d_{p}}{t_{w}} = 43.232 \le \frac{82}{\sqrt{f_{y} / 250}} = 74.855 [math]

[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (460\ \text{mm}) \times (9.9\ \text{mm}) = 737.75\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{vo} = 737.75\ \text{kN} [math]

DCR = 150 kN / 737.75 kN = 0.203 ≤ 1.0, OK

Summary of checks

Design checkDesign action effectDesign capacityDCRResult
Connection detailing limitations (OSL)35 mm37.5 mm0.933PASS
Bolt group in shear (OSL)150 kN288.999 kN0.519PASS
Bolt group in bearing on angle and support (OSL)150 kN270.579 kN0.554PASS
Angle in shear (OSL)150 kN259.2 kN0.579PASS
Angle in bending (OSL)150 kN648 kN0.231PASS
Angle in block shear (OSL)150 kN287.595 kN0.522PASS
Connection detailing limitations (NSL)35 mm37.5 mm0.933PASS
Bolt group in shear (NSL)150 kN285.294 kN0.526PASS
Bolt group in bearing on angle and beam web (NSL)150 kN267.11 kN0.562PASS
Angle in shear (NSL)150 kN259.2 kN0.579PASS
Angle in bending (NSL)150 kN627.097 kN0.239PASS
Angle in block shear (NSL)150 kN273.834 kN0.548PASS
Supported member in shear150 kN737.748 kN0.203PASS

The connection passes every check. The angle in shear governs the strength at 0.579, the same at both legs: one 6 mm angle has 259.2 kN of gross shear capacity, against about 285 kN for either bolt group. The angle checks all sit between 0.52 and 0.58, so the 100×6 EA is well used at 150 kN. The detailing ratio of 0.933 is higher, but it only says that the 37.5 mm end distances are close to the 35 mm minimum.

Auto Design is available for the single angle cleat in the AS 4100 module. It changes the bolts and the angle until every check passes, and keeps your members and design actions as entered. See the Auto Design page for the AS 4100 preferences it works to.

What to change if a check fails

  • Detailing limits: adjust the pitch, gauge or edge distances to the limits in Steps 1 and 7. A longer angle gives more end distance for the same bolt rows.
  • Angle in shear, bending or block shear: use a thicker or longer angle. Going from 6 mm to 8 mm raises the shear capacity by a third. A second angle on the other side of the web (a double angle cleat) doubles it.
  • Bolt group in shear: add a bolt row, which raises C, or use a larger bolt or a higher bolt grade.
  • Bolt bearing: the thin angle governs here, so a thicker angle or a larger end distance helps most. If the beam web governs, increase the 62 mm gauge so the end of the beam has more edge distance.
  • Supported member in shear: use a heavier beam, or add a web doubler at the connection.

Frequently asked questions

What are the OSL and NSL?

The outstanding leg (OSL) is the leg bolted to the support, here the leg on the column flange. The near side leg (NSL) is the leg bolted to the beam web. The report checks the bolts and the angle at each leg separately, OSL first.

Why are both bolt groups designed for an eccentricity?

The angle is on one side of the beam web, so each line of bolts is offset from the line where the other leg transfers its load. In this example the eccentricity is 60 mm at the column flange (the bolt gauge from the web centreline) and 62 mm at the beam web (the gauge from the column face), and the module uses the instantaneous centre of rotation method for each bolt group.

Why does the angle shear govern rather than the bolts?

A single 6 mm angle has 259.2 kN of gross shear capacity, while each bolt group carries about 285 to 289 kN even after the eccentricity reduction. A thicker angle moves the governing check to the bolts or to bearing.

Why was the 150 kN design shear not increased to the Clause 9.1.4 minimum?

Clause 9.1.4 asks for a simple connection to be designed for at least the lesser of 0.15 times the beam’s design shear capacity and 40 kN. For this 460 UB 82.1 that is 40 kN, and the 150 kN entered is larger, so it is used as is.

What is the 12 mm clearance?

It is the gap between the end of the beam and the face of the column flange, so the beam can be fitted without touching the support. It sets the 50 mm horizontal edge distance on the beam web, which is the 62 mm gauge less the clearance.

Single or double angle cleat?

A single angle is quicker to fit and leaves one side of the web clear, but its beam web bolts are in single shear and the connection is loaded on one side only. A double angle cleat puts the beam web bolts in double shear and doubles the angle capacity: the same beam, column and 100×6 EA angles give a governing ratio of 0.289 in the double angle cleat example, against 0.579 here. Both are in the AS 4100 module.

Design a single angle cleat connection for free

Every number on this page comes from one solve. Pick AS 4100:2020 and the single angle, enter your beam, support, bolts and design shear, and see each of these checks in your browser. There is nothing to install.

The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every design capacity and DCR, for AS 4100:2020 shear connections, moment connections and splices. The bolt calculator covers the bolt group checks on their own.