Double plate connection design to AISC 360 follows the beam reaction from the beam web, through bolts in double shear, into two plates and down their welds to the support. The bolts are checked for shear by the instantaneous center of rotation method and for bearing and tear-out on both plates and on the beam web. The plates are checked for block shear, shear, flexure and the interaction of shear and flexure, the coped beam for shear and flexure, and each plate’s weld for strength and for the size needed to develop the plate. Detailing limits on both sides of the connection come first.
This page works one example from start to finish: a W12x14 beam with a 3 1/2 in by 3/4 in bottom cope, framing into the flange of a W14x90 column, with a factored end shear of 12 kip (LRFD). Two 3/4 in A325N bolts pass through the beam web and two 3/8 in A36 plates, one on each side of the web. The design is to AISC 360-16 and the AISC Manual 15th Edition. Every equation is written out with its numbers, in the same order as the calc sheet that the SkyCiv Connection Design module produces for this connection.
What is a double plate connection?
A double plate connection is a shear connection made of two plates, each fillet welded to the support, that sandwich the beam web. The bolts pass through both plates and the web, so each bolt works in double shear. It is detailed as a simple connection: it carries the beam end shear and is not designed for an end moment.
Compared with a single plate connection, the second plate doubles the number of shear planes per bolt and puts plate material on both faces of the web, so the load path is symmetric about the web. You can see the other shear connection types on the shear connections page.
In this example the plates are welded to the flange of the column, with short-slotted holes in the plates and standard holes in the beam web. Plate 1 is welded on both faces with 1/4 in fillets, and plate 2 on its outer face with a 1/2 in fillet. Section A-A shows a 1/8 in gap between each plate and the beam web, with shim plates as required.

Elevation of the example connection. The beam stops 1/2 in short of the column flange, and the bolt line is 2 in from the face of the support.

Section A-A. Plate 1 has an E70XX 1/4 in fillet weld on both faces, and plate 2 a single 1/2 in fillet weld on its outer face.

The same connection in SkyCiv Connection Design, with the double plate on the Assembly tab.
Double plate connection design: the steps at a glance
- Check the detailing limits at the beam side: bolt spacing, edge distances, connection depth and cope depth.
- Check the bolt group in shear by the instantaneous center of rotation.
- Check whether the plate ductility check applies.
- Check bolt bearing and tear-out on the double plate.
- Check bolt bearing and tear-out on the beam web.
- Check the effective strength of the bolt group, bolt by bolt.
- Check the double plate in block shear.
- Check the double plate in shear.
- Check the double plate in flexure.
- Check the shear and moment interaction of the double plate.
- Check the shear and flexure interaction of the double plate for rupture.
- Check the coped beam in shear.
- Check the coped beam in flexure.
- Check the detailing limits at the support side.
- Check the plate 1 weld to the column flange.
- Check the plate 2 weld to the column flange.
- Check that each weld can develop its plate.
Design inputs for this example
The design code is AISC 360-16 LRFD. Section properties are from the AISC Manual.
| Item | Symbol | Value |
|---|---|---|
| Factored shear | [mathin] V_{u} [mathin] | 12 kip |
| Beam | W12x14, A992 | |
| Beam depth / web thickness | [mathin] d_{bm},\ t_{wb} [mathin] | 11.9 in / 0.2 in |
| Beam flange width / thickness | [mathin] b_{fb},\ t_{fb} [mathin] | 3.97 in / 0.225 in |
| Bottom cope length / depth | [mathin] L_{cb},\ D_{cb} [mathin] | 3.5 in / 0.75 in |
| Column | W14x90, A992 | |
| Column depth / web thickness | [mathin] d_{sup},\ t_{ws} [mathin] | 14 in / 0.44 in |
| Column flange width / thickness | [mathin] b_{fs},\ t_{fs} [mathin] | 14.5 in / 0.71 in |
| Beam and column yield / tensile stress | [mathin] F_{y},\ F_{u} [mathin] | 50 ksi / 65 ksi |
| Modulus of elasticity | [mathin] E [mathin] | 29000 ksi |
| Item | Symbol | Value |
|---|---|---|
| Double plate | 2-PL 3/8 x 3 1/2 x 6, A36 | |
| Plate width / depth / thickness | [mathin] b_{p},\ d_{p},\ t_{p} [mathin] | 3.5 in / 6 in / 0.375 in |
| Plate yield / tensile stress | [mathin] F_{yp},\ F_{up} [mathin] | 36 ksi / 58 ksi |
| Bolts | 3/4 in A325N | |
| Bolt diameter | [mathin] d_{b} [mathin] | 0.75 in |
| Nominal tensile / shear strength | [mathin] F_{nt},\ F_{nv} [mathin] | 90 ksi / 54 ksi |
| Shear planes | [mathin] N_{s} [mathin] | 2 |
| Holes in plates / beam web | Short-slotted (HSSL) / standard (STD) | |
| Welds to column flange | E70XX, plate 1: 1/4 in both faces; plate 2: 1/2 in one face | |
| Filler metal strength | [mathin] F_{EXX} [mathin] | 70 ksi |
| Geometry | Symbol | Value |
|---|---|---|
| Bolt rows / row spacing | [mathin] n_{r},\ s_{r} [mathin] | 2 / 3 in |
| Bolt columns | [mathin] n_{c} [mathin] | 1 |
| Beam web clearance to column flange | [mathin] clr [mathin] | 0.5 in |
| Horizontal edge distance on beam web | [mathin] L_{eh} [mathin] | 1.5 in |
| Vertical edge distance on beam web | [mathin] L_{ev} [mathin] | 3.7 in |
| Vertical / horizontal edge distance on plates | [mathin] L_{ev},\ L_{eh} [mathin] | 1.5 in / 1.5 in |
| Bolt group eccentricity | [mathin] e [mathin] | 2 in |
Step 1: Connection detailing limits at the beam side (AISC 360-16 J3.3, J3.4)
Before any strength check, the bolt layout has to be buildable and match the assumptions behind the strength equations. The minimum bolt spacing is 2 2/3 times the bolt diameter (J3.3), 2 in for a 3/4 in bolt, and the minimum edge distance for a 3/4 in bolt is 1 in (Table J3.4). The minimum horizontal edge distance on the plates is larger, 1.125 in, because the plates have slotted holes. The connection depth and the bottom cope depth are checked against the limits the software sets for this beam.
| Detailing limit | Limit (in) | Actual (in) | DCR | Result |
|---|---|---|---|---|
| Minimum bolt row spacing | 2.000 | 3.000 | 0.667 | PASS |
| Maximum bolt row spacing | 6.000 | 3.000 | 0.500 | PASS |
| Plate minimum vertical edge distance | 1.000 | 1.500 | 0.667 | PASS |
| Plate minimum horizontal edge distance | 1.125 | 1.500 | 0.750 | PASS |
| Beam minimum vertical edge distance | 1.000 | 3.700 | 0.270 | PASS |
| Beam minimum horizontal edge distance | 1.000 | 1.500 | 0.667 | PASS |
| Minimum connection depth | 5.188 | 6.000 | 0.865 | PASS |
| Maximum connection depth | 10.750 | 6.000 | 0.558 | PASS |
| Minimum bottom cope depth | 0.750 | 0.750 | 1.000 | PASS |
For a minimum limit the ratio is limit over actual, and for a maximum it is actual over limit. The governing row is the bottom cope depth:
[math] DCR = \frac{0.75\ \text{in}}{0.75\ \text{in}} = 1 [math]
DCR = 1.000 ≤ 1.0, OK
A ratio of exactly 1.000 here is not a strength problem. The 3/4 in cope was cut at the minimum depth, so the check sits on its limit.
Step 2: Bolt group in shear (AISC 360-16 J3.6, AISC Manual Part 7)
The shear acts at the face of the support, 2 in from the bolt line, so the two bolts carry a moment as well as the shear. The report uses the full eccentricity here, and notes that the Manual Table 10-9 reduction to half the distance applies to a single plate only. The instantaneous center of rotation method turns the eccentric group into a bolt group coefficient C.
| Bolt | x (in) | y (in) | R (kip) | Rx (kip) | Ry (kip) | Mn (kip-in) |
|---|---|---|---|---|---|---|
| 1 | 0.00 | 0.00 | 35.12 | 28.10 | 21.07 | 65.85 |
| 2 | 0.00 | 3.00 | 35.12 | -28.10 | 21.07 | 65.85 |
Bolt 1 is at the bottom of the line. The iteration converges with the instantaneous center, measured from bolt 1, at:
[math] x_{ic} = -1.125\ \text{in}, \qquad y_{ic} = 1.5\ \text{in} [math]
[math] C = 1.18, \qquad C’ = 2.9445\ \text{in} [math]
The bolts are in double shear, [mathin] N_{s} = 2 [mathin]. The filler factor of J5.2(a) is taken with [mathin] t = 0.25\ \text{in} [mathin]:
[math] h_{f} = 1 – 0.4\left( t – 0.25\ \text{in} \right) = 1 – 0.4 \times \left( 0.25\ \text{in} – 0.25\ \text{in} \right) = 1 [math]
[math] \phi R_{n} = \phi\, F_{nv}\, \frac{\pi}{4} d_{b}^{2}\, N_{s}\, C\, h_{f} = (0.75) \times (54\ \text{ksi}) \times \frac{\pi}{4} \times (0.75\ \text{in})^{2} \times (2) \times (1.18) \times (1) = 42.226\ \text{kip} [math]
DCR = 12 kip / 42.226 kip = 0.284 < 1.0, OK
With two bolts, the 2 in eccentricity costs the group 41% of its concentric strength: C = 1.18 instead of 2.
Step 3: Plate ductility check (AISC Manual p. 10-90)
The Manual’s ductility check makes sure the plate strength does not exceed the bolt group strength. The report finds it does not apply here, because the horizontal edge distance on both the plates and the beam web is at least twice the bolt diameter: [mathin] L_{eh} = 1.5\ \text{in} \ge 2 d_{b} = 1.5\ \text{in} [mathin]. It does not appear in the summary of checks.
Step 4: Bolt bearing and tear-out on the double plate (AISC 360-16 J3.10)
Each bolt bears on both plates, so the combined thickness [mathin] 2t_{p} = 0.75\ \text{in} [mathin] is used. The hole dimension along the line of force is [mathin] d_{h} = 0.8125\ \text{in} [mathin]. The clear distance of the edge bolt to the plate edge, and of the inner bolt to the next hole:
[math] l_{c1} = L_{ev} – \frac{d_{h}}{2} = 1.5\ \text{in} – \frac{0.8125\ \text{in}}{2} = 1.0938\ \text{in} [math]
[math] l_{c2} = s_{r} – d_{h} = 3\ \text{in} – 0.8125\ \text{in} = 2.1875\ \text{in} [math]
Tear-out (Eq. J3-6c) and bearing (Eq. J3-6a) are summed over the bolts and scaled by C over the number of rows, so the result is the strength of the eccentric group:
[math] \phi R_{n} = \phi \left[ \min\left( 1.2\, l_{c1},\ 2.4\, d_{b} \right) (2t_{p}) F_{up} + \min\left( 1.2\, l_{c2},\ 2.4\, d_{b} \right) (2t_{p}) F_{up} \left( n_{r} – 1 \right) \right] \left( \frac{C}{n_{r}} \right) [math]
[math] \phi R_{n} = (0.75) \left[ \min\left( 1.2 \times 1.0938,\ 2.4 \times 0.75 \right) (0.75)(58) + \min\left( 1.2 \times 2.1875,\ 2.4 \times 0.75 \right) (0.75)(58)(2 – 1) \right] \left( \frac{1.18}{2} \right) = 59.912\ \text{kip} [math]
DCR = 12 kip / 59.912 kip = 0.200 < 1.0, OK
Step 5: Bolt bearing and tear-out on the beam web (AISC 360-16 J3.10)
The beam web is 0.2 in thick, much thinner than the two plates together. Both bolts use the clear distance between holes, 2.1875 in, which is more than enough to reach the bearing limit:
[math] \phi R_{n} = \phi \min\left( 1.2\, l_{c2},\ 2.4\, d_{b} \right) t_{wb}\, F_{ub}\, C = (0.75) \times \min\left( 1.2 \times 2.1875\ \text{in},\ 2.4 \times 0.75\ \text{in} \right) \times (0.2\ \text{in}) \times (65\ \text{ksi}) \times (1.18) = 20.709\ \text{kip} [math]
DCR = 12 kip / 20.709 kip = 0.579 < 1.0, OK
Step 6: Effective strength of the bolt group (AISC 360-16 J3.6 Commentary)
Each bolt carries the lesser of its shear strength and the bearing or tear-out strength at its holes in every ply it passes through. The group strength is the sum of these per-bolt strengths, scaled by C over the number of rows for the eccentricity.
[math] \phi r_{v} = \phi\, F_{nv}\, \frac{\pi}{4} d_{b}^{2}\, N_{s}\, h_{f} = (0.75) \times (54\ \text{ksi}) \times \frac{\pi}{4} \times (0.75\ \text{in})^{2} \times (2) \times (1) = 35.785\ \text{kip} [math]
[math] \phi r_{n1e} = \phi \min\left( 1.2\, l_{c1},\ 2.4\, d_{b} \right) (2t_{p}) F_{up} = (0.75) \times \min\left( 1.2 \times 1.0938,\ 2.4 \times 0.75 \right) \times (0.75) \times (58) = 42.82\ \text{kip} [math]
[math] \phi r_{n1i} = \phi \min\left( 1.2\, l_{c2},\ 2.4\, d_{b} \right) (2t_{p}) F_{up} = (0.75) \times \min\left( 1.2 \times 2.1875,\ 2.4 \times 0.75 \right) \times (0.75) \times (58) = 58.725\ \text{kip} [math]
[math] \phi r_{n2} = \phi \min\left( 1.2\, l_{c2},\ 2.4\, d_{b} \right) t_{wb}\, F_{ub} = (0.75) \times \min\left( 1.2 \times 2.1875,\ 2.4 \times 0.75 \right) \times (0.2) \times (65) = 17.55\ \text{kip} [math]
| Bolt | Bolt shear (kip) | On the double plate (kip) | On the beam web (kip) | Effective strength (kip) |
|---|---|---|---|---|
| 1 | 35.78 | 58.73 | 17.55 | 17.55 |
| 2 | 35.78 | 42.82 | 17.55 | 17.55 |
[math] \Sigma \phi r_{eff} = (1)(17.55\ \text{kip}) + (1)(17.55\ \text{kip}) = 35.1\ \text{kip} [math]
[math] \phi R_{n,eff} = \left( \frac{C}{n_{r}} \right) \Sigma \phi r_{eff} = \left( \frac{1.18}{2} \right) \times (35.1\ \text{kip}) = 20.709\ \text{kip} [math]
DCR = 12 kip / 20.709 kip = 0.579 < 1.0, OK
This is the governing strength check. Each bolt is good for 35.785 kip in double shear, but the 0.2 in beam web limits it to 17.55 kip in bearing. The thin web, not the bolts or the plates, sets the strength of the connection.
Step 7: Double plate in block shear (AISC 360-16 J4.3)
A block of the plates can tear out around the bolts: shear along the bolt line to the top edge, and tension across to the free edge. The tension plane runs along the horizontal slots, so its hole dimension is the 1 in slot length, and 1/16 in is added to each hole for the net areas.
[math] A_{nt} = (2t_{p}) \left[ (n_{c} – 1) s_{c} + L_{eh} – (n_{c} – 0.5)(d_{h} + 0.0625\ \text{in}) \right] = (0.75\ \text{in}) \times \left[ 0 + 1.5\ \text{in} – 0.5 \times (1\ \text{in} + 0.0625\ \text{in}) \right] = 0.72656\ \text{in}^{2} [math]
[math] A_{gv} = (2t_{p}) \left[ L_{ev} + (n_{r} – 1) s_{r} \right] = (0.75\ \text{in}) \times \left[ 1.5\ \text{in} + (1)(3\ \text{in}) \right] = 3.375\ \text{in}^{2} [math]
[math] A_{nv} = (2t_{p}) \left[ d_{p} – L_{ev} – (n_{r} – 0.5)(d_{h} + 0.0625\ \text{in}) \right] = (0.75\ \text{in}) \times \left[ 6\ \text{in} – 1.5\ \text{in} – (1.5)(0.8125\ \text{in} + 0.0625\ \text{in}) \right] = 2.3906\ \text{in}^{2} [math]
With [mathin] U_{bs} = 0.5 [mathin], Eq. J4-5 gives:
[math] \phi R_{n} = \phi \min\left( 0.6\, F_{up} A_{nv} + U_{bs} F_{up} A_{nt},\ 0.6\, F_{yp} A_{gv} + U_{bs} F_{up} A_{nt} \right) [math]
[math] \phi R_{n} = (0.75) \times \min\left( 0.6(58)(2.3906) + 0.5(58)(0.72656),\ 0.6(36)(3.375) + 0.5(58)(0.72656) \right) = 70.478\ \text{kip} [math]
DCR = 12 kip / 70.478 kip = 0.170 < 1.0, OK
Step 8: Double plate in shear (AISC 360-16 J4.2)
[math] A_{gv} = d_{p} (2t_{p}) = (6\ \text{in}) \times (0.75\ \text{in}) = 4.5\ \text{in}^{2} [math]
[math] \phi R_{n,sy} = \phi\, 0.6\, F_{yp} A_{gv} = (1) \times 0.6 \times (36\ \text{ksi}) \times (4.5\ \text{in}^{2}) = 97.2\ \text{kip} [math]
[math] A_{nv} = (2t_{p}) \left[ d_{p} – n_{r}(d_{h} + 0.0625\ \text{in}) \right] = (0.75\ \text{in}) \times \left[ 6\ \text{in} – 2 \times (0.8125\ \text{in} + 0.0625\ \text{in}) \right] = 3.1875\ \text{in}^{2} [math]
[math] \phi R_{n,sr} = \phi\, 0.6\, F_{up} A_{nv} = (0.75) \times 0.6 \times (58\ \text{ksi}) \times (3.1875\ \text{in}^{2}) = 83.194\ \text{kip} [math]
[math] \phi R_{n} = \min\left( 97.2\ \text{kip},\ 83.194\ \text{kip} \right) = 83.194\ \text{kip} [math]
DCR = 12 kip / 83.194 kip = 0.144 < 1.0, OK
Step 9: Double plate in flexure (AISC 360-16 F11.2, AISC Manual Part 9 and Part 15)
Each plate is a short, deep cantilever from the face of the support to the bolt line, so the report treats it like a double-coped beam, with the eccentricity as the unbraced length, [mathin] L_{b} = 2\ \text{in} [mathin]. First the slenderness parameter is compared with its limits:
[math] \frac{0.08E}{F_{y}} = 64.444 \lt \frac{L_{b}\, d}{t^{2}} = \frac{(2\ \text{in})(6\ \text{in})}{(0.375\ \text{in})^{2}} = 85.333 \le \frac{1.9E}{F_{y}} = 1530.6 [math]
So the plate is in the inelastic range of Eq. F11-2. The section moduli of one plate:
[math] Z = \frac{t_{p}\, d_{p}^{2}}{4} = \frac{(0.375\ \text{in})(6\ \text{in})^{2}}{4} = 3.375\ \text{in}^{3}, \qquad S = \frac{t_{p}\, d_{p}^{2}}{6} = \frac{(0.375\ \text{in})(6\ \text{in})^{2}}{6} = 2.25\ \text{in}^{3} [math]
The lateral-torsional buckling modification factor from Manual Eq. 9-15, with no top cope on the plate:
[math] C_{b} = \left[ 3 + \ln\left( \frac{L_{b}}{d_{p}} \right) \right] \left( 1 – \frac{d_{ct}}{d_{p}} \right) \ge 1.84 = \left[ 3 + \ln\left( \frac{2}{6} \right) \right] \times (1 – 0) = 1.9014 [math]
The flexural strength of the two plates:
[math] \phi M_{n} = \phi \left[ C_{b} \left( 1.52 – 0.274 \frac{L_{b}\, d}{t^{2}} \frac{F_{yp}}{E} \right) F_{yp} S \le F_{yp} Z \right] \times 2 [math]
[math] \phi M_{n} = (0.9) \left[ (1.9014) \left( 1.52 – 0.274 \times 85.333 \times \frac{36}{29000} \right) (36\ \text{ksi})(2.25\ \text{in}^{3}) \le (36\ \text{ksi})(3.375\ \text{in}^{3}) \right] \times 2 = 18.225\ \text{kip-ft} [math]
The result is the plastic moment cap, 0.9 x 36 ksi x 3.375 in3 x 2, so the plates yield before they buckle. As a shear at the 2 in lever arm:
[math] \phi V_{n,y} = \frac{\phi M_{n}}{L_{b}} = \frac{18.225\ \text{kip-ft}}{2\ \text{in}} = 109.35\ \text{kip} [math]
Flexural rupture uses the net plastic section modulus of both plates (Manual Table 15-3), with the two holes removed:
[math] Z_{net} = \frac{(2t_{p}) d_{p}^{2}}{4} – (2t_{p})(d_{h} + 0.0625\ \text{in})\, s_{r} \left\lfloor \frac{n_{r}^{2}}{4} \right\rfloor = \frac{(0.75)(6)^{2}}{4} – (0.75)(0.875)(3)(1) = 4.7813\ \text{in}^{3} [math]
[math] \phi M_{n} = \phi\, F_{up} Z_{net} = (0.75) \times (58\ \text{ksi}) \times (4.7813\ \text{in}^{3}) = 17.332\ \text{kip-ft} [math]
[math] \phi V_{n,r} = \frac{17.332\ \text{kip-ft}}{2\ \text{in}} = 103.99\ \text{kip} [math]
[math] \phi V_{n} = \min\left( 109.35\ \text{kip},\ 103.99\ \text{kip} \right) = 103.99\ \text{kip} [math]
DCR = 12 kip / 103.99 kip = 0.115 < 1.0, OK
Step 10: Shear and moment interaction of the double plate (AISC Manual Eq. 10-5)
The moment at the bolt line acts together with the shear, so the plate yielding strengths are combined:
[math] M_{r} = V_{r}\, L_{b} = (12\ \text{kip})(2\ \text{in}) = 2\ \text{kip-ft} [math]
[math] I_{nt} = \left( \frac{V_{r}}{\phi V_{n}} \right)^{2} + \left( \frac{M_{r}}{\phi M_{n}} \right)^{2} = \left( \frac{12}{97.2} \right)^{2} + \left( \frac{2}{18.225} \right)^{2} = 0.027284 [math]
DCR = 0.027 < 1.0, OK
Step 11: Shear and flexure interaction of the double plate for rupture
The same interaction with the rupture strengths, flexural rupture from Step 9 and shear rupture from Step 8:
[math] Interaction = \left( \frac{V_{r}}{\phi V_{n}} \right)^{2} + \left( \frac{V_{r}}{\phi R_{n,sr}} \right)^{2} = \left( \frac{12}{103.99} \right)^{2} + \left( \frac{12}{83.194} \right)^{2} = 0.034121 [math]
DCR = 0.034 < 1.0, OK
Step 12: Coped beam in shear (AISC 360-16 J4.2)
The bottom cope leaves [mathin] d_{coped} = 11.15\ \text{in} [mathin] of web at the connection.
[math] \phi R_{n,sy} = \phi\, 0.6\, F_{yb}\, d_{coped}\, t_{wb} = (1) \times 0.6 \times (50\ \text{ksi}) \times (11.15\ \text{in})(0.2\ \text{in}) = 66.9\ \text{kip} [math]
[math] A_{nv} = t_{wb} \left[ d_{coped} – n_{r}(d_{h} + 0.0625\ \text{in}) \right] = (0.2\ \text{in}) \times \left[ 11.15\ \text{in} – 2 \times (0.8125\ \text{in} + 0.0625\ \text{in}) \right] = 1.88\ \text{in}^{2} [math]
[math] \phi R_{n,sr} = \phi\, 0.6\, F_{ub} A_{nv} = (0.75) \times 0.6 \times (65\ \text{ksi}) \times (1.88\ \text{in}^{2}) = 54.99\ \text{kip} [math]
[math] \phi R_{n} = \min\left( 66.9\ \text{kip},\ 54.99\ \text{kip} \right) = 54.99\ \text{kip} [math]
DCR = 12 kip / 54.99 kip = 0.218 < 1.0, OK
Step 13: Coped beam in flexure (AISC Manual Part 9)
At the end of the cope, the reduced beam section carries the shear times the cope eccentricity, [mathin] e_{c} = 4\ \text{in} [mathin]. The report uses the coped section moduli [mathin] S_{x} = 5.8533\ \text{in}^{3} [mathin] and [mathin] Z_{x} = 9.9503\ \text{in}^{3} [mathin] and the Manual’s local web buckling procedure, with the 3.5 in cope length [mathin] c [mathin]:
[math] \lambda = \frac{h_{o}}{t_{wb}} = \frac{11.15\ \text{in}}{0.2\ \text{in}} = 55.75 [math]
[math] f = 2\left( \frac{c}{d_{bm}} \right) = 2 \times \frac{3.5}{11.9} = 0.58824 \qquad \text{(Eq. 9-14a)} [math]
[math] k = 2.2\left( \frac{h_{o}}{c} \right)^{1.65} = 2.2 \times \left( \frac{11.15}{3.5} \right)^{1.65} = 14.884 \qquad \text{(Eq. 9-13a)} [math]
[math] \lambda_{p} = 0.475 \sqrt{\frac{f k\, E}{F_{yb}}} = 0.475 \times \sqrt{\frac{(0.58824)(14.884)(29000\ \text{ksi})}{50\ \text{ksi}}} = 33.849 \qquad \text{(Eq. 9-12)} [math]
Here [mathin] f k \ge 1.61 [mathin], so it is used as is. Since [mathin] \lambda_{p} \lt \lambda \le 2\lambda_{p} [mathin], the strength is interpolated between the plastic and the yield moment (Eq. 9-7):
[math] \phi M_{n} = \phi \left[ F_{yb} Z_{x} – \left( F_{yb} Z_{x} – F_{yb} S_{x} \right) \left( \frac{\lambda}{\lambda_{p}} – 1 \right) \right] [math]
[math] \phi M_{n} = (0.9) \left[ (50)(9.9503) – \left( (50)(9.9503) – (50)(5.8533) \right) \left( \frac{55.75}{33.849} – 1 \right) \right] = 27.373\ \text{kip-ft} [math]
[math] \phi V_{n} = \frac{\phi M_{n}}{e_{c}} = \frac{27.373\ \text{kip-ft}}{4\ \text{in}} = 82.118\ \text{kip} [math]
DCR = 12 kip / 82.118 kip = 0.146 < 1.0, OK
Step 14: Connection detailing limits at the support side
Plate 1 is welded on both faces, so its inner weld sits between the two plates. Its size is limited by the distance between the plates and by the beam clearance:
| Detailing limit | Limit (in) | Actual (in) | DCR | Result |
|---|---|---|---|---|
| Maximum plate 1 weld size per distance between plates | 0.438 | 0.250 | 0.571 | PASS |
| Maximum plate 1 weld size per beam clearance | 0.500 | 0.250 | 0.500 | PASS |
DCR = 0.25 in / 0.438 in = 0.571 < 1.0, OK
Step 15: Plate 1 weld to the column flange (AISC 360-16 J2.4, AISC Manual Part 9)
Each plate takes half the shear, [mathin] 0.5V_{u} = 6\ \text{kip} [mathin]. The weld strength is capped by the base metal it joins (Manual Eq. 9-2). Plate 1 is welded on both faces, so each weld gets half the plate thickness:
[math] D_{max} = \frac{\min\left( \frac{t_{p}}{2} F_{up},\ t_{fs} F_{us} \right)}{3.09\ \text{kip/in}} = \frac{\min\left( (0.1875\ \text{in})(58\ \text{ksi}),\ (0.71\ \text{in})(65\ \text{ksi}) \right)}{3.09\ \text{kip/in}} = 3.5194 [math]
[mathin] D_{max} [mathin] is in sixteenths of an inch, which is less than the 4 sixteenths of the 1/4 in weld, so the report takes the lesser of W and [mathin] D_{max}/16 [mathin]. The effective length deducts twice the weld size at the ends (AISC Manual Part 10), on both faces:
[math] L_{w} = 2\left[ d_{p} – 2W \right] = 2 \times \left[ 6\ \text{in} – 2 \times 0.25\ \text{in} \right] = 11\ \text{in} [math]
[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left( W,\ \frac{D_{max}}{16} \right) L_{w} = (0.75) \times 0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left( 0.25\ \text{in},\ \frac{3.5194}{16} \right) \times (11\ \text{in}) = 53.894\ \text{kip} [math]
DCR = 6 kip / 53.894 kip = 0.111 < 1.0, OK
Step 16: Plate 2 weld to the column flange (AISC 360-16 J2.4, AISC Manual Part 9)
Plate 2 has a single weld, so the full plate thickness counts in the base metal check. Again the plate governs, and 7.0388 sixteenths is a little less than the 1/2 in weld:
[math] D_{max} = \frac{\min\left( t_{p} F_{up},\ t_{fs} F_{us} \right)}{3.09\ \text{kip/in}} = \frac{\min\left( (0.375\ \text{in})(58\ \text{ksi}),\ (0.71\ \text{in})(65\ \text{ksi}) \right)}{3.09\ \text{kip/in}} = 7.0388 [math]
[math] L_{w} = d_{p} – 2W = 6\ \text{in} – 2 \times 0.5\ \text{in} = 5\ \text{in} [math]
[math] \phi R_{n} = (0.75) \times 0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left( 0.5\ \text{in},\ \frac{7.0388}{16} \right) \times (5\ \text{in}) = 48.994\ \text{kip} [math]
DCR = 6 kip / 48.994 kip = 0.122 < 1.0, OK
Step 17: Weld to develop each plate (AISC Manual p. 10-87)
The welds should be strong enough to develop the plates, so that the plate yields before the weld fails. For fillet welds on both faces the Manual asks for 5/8 of the plate thickness, and for a weld on one face only, twice that:
[math] W_{duc,1} = \frac{5}{8} t_{p} = \frac{5}{8} \times 0.375\ \text{in} = 0.23438\ \text{in} \le W = 0.25\ \text{in} [math]
[math] W_{duc,2} = \frac{5}{4} t_{p} = \frac{5}{4} \times 0.375\ \text{in} = 0.46875\ \text{in} \le W = 0.5\ \text{in} [math]
DCR = 0.23438 in / 0.25 in = 0.938 and 0.46875 in / 0.5 in = 0.938, both < 1.0, OK
These ratios compare weld sizes, not a load with a strength. They are high because 1/4 in and 1/2 in are the next sixteenth above the required sizes.
Summary of checks
| Design check | Demand | Capacity | DCR | Result |
|---|---|---|---|---|
| Detailing limits at the beam side | 0.75 in | 0.75 in | 1.000 | PASS |
| Bolt group in shear | 12 kip | 42.226 kip | 0.284 | PASS |
| Bolt bearing and tear-out on the double plate | 12 kip | 59.912 kip | 0.200 | PASS |
| Bolt bearing and tear-out on the beam web | 12 kip | 20.709 kip | 0.579 | PASS |
| Effective strength of the bolt group | 12 kip | 20.709 kip | 0.579 | PASS |
| Double plate in block shear | 12 kip | 70.478 kip | 0.170 | PASS |
| Double plate in shear | 12 kip | 83.194 kip | 0.144 | PASS |
| Double plate in flexure | 12 kip | 103.99 kip | 0.115 | PASS |
| Shear and moment interaction of the double plate | 0.027 | 1 | 0.027 | PASS |
| Shear and flexure interaction, rupture | 0.034 | 1 | 0.034 | PASS |
| Coped beam in shear | 12 kip | 54.99 kip | 0.218 | PASS |
| Coped beam in flexure | 12 kip | 82.118 kip | 0.146 | PASS |
| Detailing limits at the support side | 0.25 in | 0.438 in | 0.571 | PASS |
| Plate 1 weld to the column flange | 6 kip | 53.894 kip | 0.111 | PASS |
| Plate 2 weld to the column flange | 6 kip | 48.994 kip | 0.122 | PASS |
| Weld to develop plate 1 | 0.234 in | 0.25 in | 0.938 | PASS |
| Weld to develop plate 2 | 0.469 in | 0.5 in | 0.938 | PASS |
Every check in this double plate connection design passes. The highest ratios do not compare a load with a strength: the cope depth sits on its 0.75 in minimum at 1.000, and both welds are 0.938 of the size needed to develop the plates. Of the strength checks, bolt bearing on the 0.2 in beam web governs at 0.579, both on its own and in the bolt-by-bolt effective strength. The bolts in double shear come next at 0.284.
Auto Design is available for the double plate connection to a column flange. It changes the connection’s design variables until every check passes, and keeps your members and loads as entered. See the Auto Design page for the preferences it works to.
What to change if a check fails
- Bearing on the beam web or effective strength: add a bolt row so each bolt carries less, or use a larger bolt. The web thickness is fixed by the beam, so a heavier beam is the other option.
- Bolt group in shear: add a bolt row, which raises C, or use a larger bolt or a higher bolt grade.
- Plate block shear, shear or flexure: make the plates deeper, or thicker. A thicker plate also raises the weld size needed to develop it.
- Coped beam shear or flexure: make the cope shorter or shallower where the supporting member allows, or use a heavier beam.
- Plate welds: increase the weld size, within the room between the plates for plate 1, or make the plates deeper to lengthen the welds.
- Weld to develop the plate: use at least 5/8 of the plate thickness for a weld on both faces, or 5/4 for a weld on one face.
- Detailing limits: adjust the bolt spacing, edge distances, plate depth or cope depth to the limits in Steps 1 and 14.
Frequently asked questions
Why are the bolts in double shear?
Each bolt passes through plate 1, the beam web and plate 2, so it crosses two shear planes. That doubles its shear strength to 35.785 kip per bolt, which is why bolt shear is far from governing here and the thin beam web limits the connection instead.
Why does the report use the full 2 in eccentricity for the bolts?
The report notes that the Manual Table 10-9 reduction, which lets you take half the distance for a conventional single plate, applies to a single plate only. For the double plate it takes the full distance from the face of the support to the bolt line, 2 in, which is the conservative choice.
Why is the plate checked like a double-coped beam?
Each plate is a short, deep, thin rectangle in bending between the weld and the bolt line. The AISC Manual’s double-coped beam procedure covers a rectangular section like this, so the report uses Eq. F11-2 with the eccentricity as the unbraced length and the plate depth as the depth. Here the plates reach their plastic moment, so buckling does not reduce the strength.
Why is each plate weld designed for half the shear?
The two plates share the beam reaction equally through the bolts, so each plate and its weld take 0.5 Vu, 6 kip here. Plate 1 has welds on both faces and plate 2 on one face, so their effective lengths, base metal limits and required sizes differ.
Why is plate 1’s weld size limited by the distance between the plates?
Plate 1’s inner weld is laid between the two plates, in the space in front of the beam end. The software limits that weld to 0.438 in for the space available and to 0.5 in for the beam clearance, and the 1/4 in weld is within both.
How would this change for AISC ASD instead of LRFD?
The limit states and nominal strengths are the same. With AISC ASD you compare service-level forces against the nominal strength divided by a safety factor: a resistance factor of 0.75 becomes a safety factor of 2.00, 0.90 becomes 1.67, and 1.00 for shear yielding becomes 1.50.
Design a double plate connection for free
Every number on this page comes from one solve. Pick the double plate configuration, enter your beam, support, plates, bolts, welds and shear, and the free calculator runs each of these checks in your browser without anything to install.
The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every capacity and DCR, for AISC 360-22 and AISC 360-16 (LRFD and ASD) and AS 4100:2020. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.
References
- AISC 360-16, Specification for Structural Steel Buildings: F11.2 (Eq. F11-2), J2.4 (Eq. J2-4), J3.3, J3.4 (Table J3.4), J3.6 (Eq. J3-1) and Commentary, J3.10 (Eq. J3-6a, J3-6c), J4.2 (Eq. J4-3, J4-4), J4.3 (Eq. J4-5), J5.2(a).
- AISC Steel Construction Manual, 15th Edition: Part 7 (instantaneous center of rotation, Eq. 7-1), Part 9 (Eq. 9-2, 9-4, 9-7, 9-12, 9-13a, 9-14a, 9-15), Part 10 (Table 10-9, p. 10-87, p. 10-90, Eq. 10-5), Part 15 (Table 15-3).
- Design of steel connections using AISC 360-16
- Auto Design in SkyCiv Connection Design
Harold Munalem
Product Manager, Connection Design
10+ years in steel connection design
LinkedIn
