To design a bolted beam splice to AS 4100, you first raise the design actions to the minimums of Clause 9.1.4, share them between the flanges and the web, and then check each load path: the flange plates and their bolts for the flange forces in tension and in compression, the web plates and their bolts for the shear and the web share of the axial force, and the beam itself at the bolt holes. The detailing limits on pitch and edge distance come first, because the capacity equations assume a layout that can be built.
This page works through one example from start to finish: a 460 UB 74.6 beam spliced to another 460 UB 74.6 with a 12 mm gap, 16 mm flange plates on six M24 8.8/S bolts each side of the joint and two 10 mm web plates, designed to AS 4100:2020. Every equation is written out with its numbers, in the same order as the calculation report that the SkyCiv Connection Design module produces for it. The scope and conventions of the AS 4100 module are on the design of steel connections using AS 4100:2020 page.
What is a bolted beam splice?
A beam splice joins two lengths of beam along the span, so that a long member can be transported and erected in pieces, or so that a cantilever or continuous beam can be broken at a convenient point. In this bolted form, a cover plate on the outside of each flange and a pair of plates on the web are bolted through to both beams. The flange plates carry the flange forces from the bending moment and the axial force, and the web plates carry the shear and the web share of the axial force.
The beam ends are not in contact: there is a 12 mm gap between them, so compression as well as tension passes through the plates and bolts. That is why this splice has compression checks on the flange plates, the beam flanges and the web plates. You can check a splice of your own directly in the beam splice calculator.
In this example both beams are 460 UB 74.6. Each flange plate has two lines of three bolts on each side of the joint, and each web plate has one line of three bolts on each side.

Plan view of the example splice. The 16 mm flange plate has three bolt rows at 75 mm on a 90 mm gauge each side of the 12 mm gap.

Section A-A, a side view along the beams. A 10 mm web plate sits on each side of the web, with three bolts at 75 mm each side of the gap.

The same splice in SkyCiv Connection Design, with the flange plate selected.
Beam splice design: the steps at a glance
- Raise the design actions to the Clause 9.1.4 minimums and share them between the flanges and the web (Clause 9.1.3).
- Check the flange plate detailing limits.
- Check the flange bolt group in shear and in bearing.
- Check the flange plate and the beam flange in block shear.
- Check the flange plate and the beam flange in tension and in compression.
- Check the section moment capacity of the beam at the flange holes, reduced for axial force.
- Check the web plate detailing limits.
- Check the web bolt group in shear, by the instantaneous centre of rotation, and in bearing.
- Check the web plates in tension, compression, bending, shear and block shear.
- Check the beam web in block shear under axial tension.
The report runs the same checks for the left and the right beam. Both are 460 UB 74.6 with the same bolts and distances, so the results are identical and this page shows the left beam.
Design inputs for this example
The design code is AS 4100:2020, with section properties from the Australian section database. The yield strength of each part follows its grade and thickness: the 14.5 mm beam flange gives 300 MPa, the 16 mm flange plate 300 MPa and the 10 mm web plates 310 MPa.
| Item | Symbol | Value |
|---|---|---|
| Left and right beam | 460 UB 74.6, AS/NZS 3679.1 Gr.300 | |
| Beam depth / web thickness | [mathin] d_{b},\ t_{wb} [mathin] | 457 mm / 9.1 mm |
| Beam flange width / thickness | [mathin] b_{fb},\ t_{fb} [mathin] | 190 mm / 14.5 mm |
| Beam gross area | [mathin] A_{g} [mathin] | 9520 mm² |
| Plastic section modulus (major axis) | [mathin] S_{x} [mathin] | 1.66 x 10⁶ mm³ |
| Beam yield / tensile strength | [mathin] f_{yb},\ f_{ub} [mathin] | 300 MPa / 440 MPa |
| Gap between the beam ends | [mathin] c [mathin] | 12 mm |
| Item | Symbol | Value |
|---|---|---|
| Flange plates (one on each flange) | PL 16 x 180 x 492, AS/NZS 3678 Gr.300 | |
| Flange plate width / length / thickness | [mathin] b_{p},\ l_{p},\ t_{p} [mathin] | 180 mm / 492 mm / 16 mm |
| Flange plate yield / tensile strength | [mathin] f_{yp},\ f_{up} [mathin] | 300 MPa / 430 MPa |
| Web plates (one on each side of the web) | 2 x PL 10 x 192 x 240, AS/NZS 3678 Gr.300 | |
| Web plate width / depth / thickness | [mathin] b_{i},\ d_{i},\ t_{i} [mathin] | 192 mm / 240 mm / 10 mm |
| Web plate yield / tensile strength | [mathin] f_{yp},\ f_{up} [mathin] | 310 MPa / 430 MPa |
| Bolts | M24 8.8/S, threads included in the shear plane | |
| Bolt diameter / minimum tensile strength | [mathin] d_{f},\ f_{uf} [mathin] | 24 mm / 830 MPa |
| Bolt core / shank area | [mathin] A_{c},\ A_{o} [mathin] | 324 mm² / 452.39 mm² |
| Holes | [mathin] d_{h} [mathin] | Nominal, 26 mm |
| Geometry (each beam) | Symbol | Value |
|---|---|---|
| Flange bolts: rows / row pitch | [mathin] n_{p},\ s_{p} [mathin] | 3 / 75 mm |
| Flange bolts: columns / gauge | [mathin] n_{g},\ s_{g} [mathin] | 2 / 90 mm |
| Flange bolts per beam, per flange | [mathin] n_{b} [mathin] | 6 |
| End distance on the beam flange (to the beam end) | [mathin] l_{eh\_f} [mathin] | 45 mm |
| End distance on the flange plate | [mathin] l_{eh\_fp} [mathin] | 45 mm |
| Edge distance on the flange plate | [mathin] l_{ev\_fp} [mathin] | 45 mm |
| Edge distance on the beam flange | [mathin] l_{ev\_f} [mathin] | 50 mm |
| Web bolts: rows / row pitch | [mathin] n_{p},\ s_{p} [mathin] | 3 / 75 mm |
| Web bolts: columns | [mathin] n_{g} [mathin] | 1 |
| End distance on the beam web (to the beam end) | [mathin] l_{eh\_w} [mathin] | 45 mm |
| Edge distances on the web plate | [mathin] l_{eh\_wp},\ l_{ev\_wp} [mathin] | 45 mm / 45 mm |
The design actions entered are a shear of 150 kN, an axial tension and an axial compression of 450 kN, and a major axis bending moment of 80 kN m. In the SkyCiv load combination these are Fy = 150 kN, Fx = 450 kN in tension and in compression, and Mz = 80 kN m.
Design actions (AS 4100 Clauses 9.1.4 and 9.1.3)
AS 4100 Clause 9.1.4 sets minimum design actions for splices. For a splice in a flexural member the bending moment is not taken less than 0.3 times the section moment capacity, and under combined actions the axial forces are not taken less than 0.3 times the section axial capacity:
[math] M_{x}^{*} = \max\left( M_{x}^{*},\ 0.3\, \phi\, f_{yb}\, S_{x} \right) = \max\left( 80\ \text{kN m},\ 0.3 \times 0.9 \times (300\ \text{MPa}) \times (1.66 \times 10^{6}\ \text{mm}^{3}) \right) = 134.46\ \text{kN m} [math]
[math] N_{t}^{*} = N_{c}^{*} = \max\left( 450\ \text{kN},\ 0.3 \times 0.9 \times (9520\ \text{mm}^{2}) \times (300\ \text{MPa}) \right) = 771.12\ \text{kN} [math]
Under Clause 9.1.3 the axial force is shared between the flanges and the web in proportion to their areas, and the moment is taken by the flanges as a couple:
[math] A_{w} = \left( d_{b} – 2\, t_{fb} \right) t_{wb} = (457\ \text{mm} – 29\ \text{mm}) \times (9.1\ \text{mm}) = 3894.8\ \text{mm}^{2}, \quad A = 2 \times 190 \times 14.5 + 3894.8 = 9404.8\ \text{mm}^{2} [math]
[math] k_{w} = \frac{A_{w}}{A} = \frac{3894.8}{9404.8} = 0.41413, \quad k_{f} = \frac{1 – k_{w}}{2} = 0.29294 [math]
[math] N_{ft}^{*} = \frac{M_{x}^{*}}{d_{b} – t_{fb}} + k_{f}\, N_{t}^{*} = \frac{134.46\ \text{kN m}}{457\ \text{mm} – 14.5\ \text{mm}} + 0.29294 \times (771.12\ \text{kN}) = 529.75\ \text{kN} [math]
The compression flange force is the same, [mathin] N_{fc}^{*} = 529.75\ \text{kN} [mathin], so [mathin] N_{f}^{*} = 529.75\ \text{kN} [mathin] (529.753 kN in the summary) is the design action effect for every flange check, in tension and in compression. The web checks use the shear and the web share of the axial force, worked out in Step 12.
Step 1: Flange plate detailing limitations (AS 4100 Clause 9.5)
The minimum pitch is [mathin] 2.5\, d_{f} = 2.5 \times 24\ \text{mm} = 60\ \text{mm} [mathin] and the minimum edge distance for an M24 bolt is [mathin] 1.75\, d_{f} = 42\ \text{mm} [mathin] from Table 9.5.2. The maximum edge distance is the lesser of 12 times the thinner ply and 150 mm, and the maximum bolt column pitch is 200 mm. The report lists the 158 mm maximum row pitch as the software’s limit.
| Detailing limit (flange plate) | Limit (mm) | Actual (mm) | DCR | Result |
|---|---|---|---|---|
| Minimum bolt row pitch on flange plate | 60.000 | 75.000 | 0.800 | PASS |
| Maximum bolt row pitch on flange plate | 158.000 | 75.000 | 0.475 | PASS |
| Minimum bolt column pitch on flange plate | 60.000 | 90.000 | 0.667 | PASS |
| Maximum bolt column pitch on flange plate | 200.000 | 90.000 | 0.450 | PASS |
| Minimum vertical edge distance on flange plate | 42.000 | 45.000 | 0.933 | PASS |
| Minimum vertical edge distance on beam flange | 42.000 | 50.000 | 0.840 | PASS |
| Minimum horizontal edge distance on flange plate | 42.000 | 45.000 | 0.933 | PASS |
| Minimum horizontal edge distance on beam flange | 42.000 | 45.000 | 0.933 | PASS |
| Maximum edge distance | 150.000 | 45.000 | 0.300 | PASS |
For a minimum limit the ratio is limit over actual, and for a maximum it is actual over limit. Three rows tie at the governing value, the 45 mm edge distances against the 42 mm minimum:
[math] DCR = \frac{42\ \text{mm}}{45\ \text{mm}} = 0.93333 [math]
DCR = 42 mm / 45 mm = 0.933 ≤ 1.0, OK
Step 2: Flange bolt group in shear (AS 4100 Clauses 9.2.2.1 and 9.3.1)
The flange force passes from the beam flange to the flange plate through the bolts in single shear. The joint is [mathin] l_{j} = (3 – 1) \times 75\ \text{mm} = 150\ \text{mm} [mathin] long, under 300 mm, so [mathin] k_{r} = 1 [mathin]. The threads are included in the one shear plane:
[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, k_{rd}\, k_{r} \left( n_{n} A_{c} + n_{x} A_{o} \right) = 0.8 \times 0.62 \times (830\ \text{MPa}) \times 1 \times 1 \times (1 \times 324\ \text{mm}^{2}) = 133.38\ \text{kN} [math]
[math] \phi V_{df} = n_{b}\, \phi V_{f} = 6 \times (133.38\ \text{kN}) = 800.31\ \text{kN} [math]
DCR = 529.75 kN / 800.31 kN = 0.662 ≤ 1.0, OK
Step 3: Flange bolts in bearing on the flange plate and beam flange (AS 4100 Clause 9.2.2.4)
Each ply is checked at the end bolts, using the distance to the end of the ply, and at the inner bolts, using the distance to the next hole. With [mathin] \phi = 0.9 [mathin], the bearing capacity of a bolt on a ply is:
[math] \phi V_{b} = \phi\, \min\left( 3.2\, d_{f}\, t_{p}\, f_{up},\ a_{e}\, t_{p}\, f_{up} \right) [math]
For the flange plate, with 44 mm at the end bolts and 61 mm at the inner bolts:
[math] \phi V_{b} = 0.9 \min\left( 3.2 \times 24 \times 16 \times 430,\ 44 \times 16 \times 430 \right) = 272.45\ \text{kN}; \quad a_{e2} = 61\ \text{mm}: \ 377.71\ \text{kN} [math]
[math] \phi V_{b,p} = 2 \left[ 272.45\ \text{kN} + 2 \times 377.71\ \text{kN} \right] = 2055.7\ \text{kN} [math]
For the 14.5 mm beam flange:
[math] \phi V_{b} = 0.9 \min\left( 3.2 \times 24 \times 14.5 \times 440,\ 44 \times 14.5 \times 440 \right) = 252.65\ \text{kN}; \quad a_{e} = 61\ \text{mm}: \ 350.26\ \text{kN} [math]
[math] \phi V_{b,f} = 2 \left[ 252.65\ \text{kN} + 2 \times 350.26\ \text{kN} \right] = 1906.3\ \text{kN} [math]
[math] \phi V_{b} = \min\left( 2055.7\ \text{kN},\ 1906.3\ \text{kN} \right) = 1906.3\ \text{kN} [math]
DCR = 529.75 kN / 1906.3 kN = 0.278 ≤ 1.0, OK
Step 4: Flange plate in block shear (AS 4100 Clause 9.1.9)
Three tear-out patterns are checked, with [mathin] \phi = 0.75 [mathin] and [mathin] k_{bs} = 1 [mathin] for a uniform tension stress:
[math] \phi R_{bs} = \phi\, \min\left( 0.6\, f_{u}\, A_{nv} + k_{bs}\, f_{u}\, A_{nt},\ 0.6\, f_{y}\, A_{gv} + k_{bs}\, f_{u}\, A_{nt} \right) [math]
Patterns 1 and 2 shear along both bolt lines:
[math] A_{gv} = 2 \left[ 45\ \text{mm} + 150\ \text{mm} \right] \times 16\ \text{mm} = 6240\ \text{mm}^{2}, \quad A_{nv} = 2 \left[ 45 + 150 – 2.5 \times 26 \right] \times 16 = 4160\ \text{mm}^{2} [math]
[math] A_{nt,1} = \left[ 90 – 26 \right] \times 16 = 1024\ \text{mm}^{2}, \quad A_{nt,2} = \left( 2 \times 45 – 26 \right) \times 16 = 1024\ \text{mm}^{2}, \quad \phi R_{bs,1} = \phi R_{bs,2} = 1135.2\ \text{kN} [math]
Pattern 3 (L pattern) shears along one bolt line and tears across both lines to one edge:
[math] A_{nt,3} = \left[ 45 + 90 – 1.5 \times 26 \right] \times 16 = 1536\ \text{mm}^{2}, \quad A_{gv} = 3120\ \text{mm}^{2}, \quad A_{nv} = 2080\ \text{mm}^{2} [math]
[math] \phi R_{bs,3} = 0.75 \min\left( 0.6 \times 430 \times 2080 + 430 \times 1536,\ 0.6 \times 300 \times 3120 + 430 \times 1536 \right) = 897.84\ \text{kN} [math]
DCR = 529.75 kN / 897.84 kN = 0.590 ≤ 1.0, OK
Step 5: Beam flange in block shear (AS 4100 Clause 9.1.9)
[math] A_{nt} = \left( 2 \times 50\ \text{mm} – 26\ \text{mm} \right) \times 14.5\ \text{mm} = 1073\ \text{mm}^{2}, \quad A_{gv} = 5655\ \text{mm}^{2}, \quad A_{nv} = 3770\ \text{mm}^{2} [math]
[math] \phi R_{bs} = 0.75 \min\left( 0.6 \times 440 \times 3770 + 440 \times 1073,\ 0.6 \times 300 \times 5655 + 440 \times 1073 \right) = 1100.5\ \text{kN} [math]
DCR = 529.75 kN / 1100.5 kN = 0.481 ≤ 1.0, OK
Step 6: Flange plate in tension (AS 4100 Clauses 7.2 and 9.1.10)
[math] A_{g} = 180\ \text{mm} \times 16\ \text{mm} = 2880\ \text{mm}^{2}, \quad A_{n} = \left( 180\ \text{mm} – 2 \times 26\ \text{mm} \right) \times 16\ \text{mm} = 2048\ \text{mm}^{2} [math]
[math] \phi N_{t} = \phi\, \min\left( A_{g}\, f_{yp},\ 0.85\, k_{t}\, A_{n}\, f_{up} \right) = 0.9 \min\left( 2880 \times 300,\ 0.85 \times 1 \times 2048 \times 430 \right) = 673.69\ \text{kN} [math]
DCR = 529.75 kN / 673.69 kN = 0.786 ≤ 1.0, OK
Step 7: Flange plate in compression (AS 4100 Clauses 6.2 and 6.3)
In compression the bolt holes are filled by the bolts, so the gross area is used and no reduction is made for the holes:
[math] \phi N_{s} = \phi\, k_{f}\, A_{g}\, f_{yp} = 0.9 \times 1 \times (2880\ \text{mm}^{2}) \times (300\ \text{MPa}) = 777.6\ \text{kN} [math]
Across the gap the plate acts as a short strut between the bolt rows either side of the splice, [mathin] l = 102\ \text{mm} [mathin], with [mathin] k_{e} = 1.2 [mathin] (Clause 4.6.3.2) and [mathin] r = t_{p} / \sqrt{12} = 4.6188\ \text{mm} [mathin]:
[math] l_{e} = 1.2 \times 102\ \text{mm} = 122.4\ \text{mm}, \quad \lambda_{n} = \frac{122.4}{4.6188} \sqrt{\frac{300}{250}} = 29.03 [math]
With [mathin] \alpha_{a} = 13.319 [mathin] and [mathin] \alpha_{b} = 0.5 [mathin] (Table 6.3.3(A)), Clause 6.3.3 gives:
[math] \lambda = \lambda_{n} + \alpha_{a}\, \alpha_{b} = 29.03 + 13.319 \times 0.5 = 35.689, \quad \eta = 0.00326 \left( 35.689 – 13.5 \right) = 0.072337 [math]
[math] \xi = \frac{\left( \lambda / 90 \right)^{2} + 1 + \eta}{2 \left( \lambda / 90 \right)^{2}} = 3.9097, \quad \alpha_{c} = \xi \left[ 1 – \sqrt{1 – \left( \frac{90}{\xi\, \lambda} \right)^{2}} \right] = 0.922 [math]
[math] \phi N_{c} = \alpha_{c}\, \phi N_{s} = 0.922 \times 777.6\ \text{kN} = 716.94\ \text{kN} [math]
DCR = 529.75 kN / 716.94 kN = 0.739 ≤ 1.0, OK
Step 8: Beam flange in tension (AS 4100 Clauses 7.2 and 9.1.10)
[math] A_{g} = 190\ \text{mm} \times 14.5\ \text{mm} = 2755\ \text{mm}^{2}, \quad A_{n} = \left( 190\ \text{mm} – 52\ \text{mm} \right) \times 14.5\ \text{mm} = 2001\ \text{mm}^{2} [math]
[math] \phi N_{t} = 0.9 \min\left( 2755 \times 300,\ 0.85 \times 2001 \times 440 \right) = 673.54\ \text{kN} [math]
DCR = 529.75 kN / 673.54 kN = 0.787 ≤ 1.0, OK
Step 9: Beam flange in compression (AS 4100 Clauses 6.2.1 and 6.2.2)
[math] \phi N_{s} = \phi\, k_{f}\, A_{g}\, f_{yb} = 0.9 \times 1 \times (2755\ \text{mm}^{2}) \times (300\ \text{MPa}) = 743.85\ \text{kN} [math]
DCR = 529.75 kN / 743.85 kN = 0.712 ≤ 1.0, OK
Step 10: Section moment capacity of the beam at the flange holes (AS 4100 Clauses 5.2 and 8.3.2)
The bolt holes in the beam flanges reduce the section where the splice moment is carried. The elastic section modulus of the beam is [mathin] Z_{x} = 1.441 \times 10^{6}\ \text{mm}^{3} [mathin]. Clause 5.2.6 checks whether the holes reduce the flange enough to matter:
[math] \Delta A_{f} = 100 \times \frac{2 \times 26\ \text{mm}}{190\ \text{mm}} = 27.368 > \Delta A_{lim} = 100 \left( 1 – \frac{300}{0.85 \times 440} \right) = 19.786 [math]
So the section moduli are reduced by the ratio of the net area to the gross area:
[math] A_{n} = 9520 – 4 \times 26 \times 14.5 = 8012\ \text{mm}^{2}, \quad Z_{n} = 1.2128 \times 10^{6}\ \text{mm}^{3}, \quad S_{n} = \frac{8012}{9520} \times 1.66 \times 10^{6} = 1.3971 \times 10^{6}\ \text{mm}^{3} [math]
For the section slenderness (Clause 5.2.2 and Table 5.2), [mathin] \lambda_{ef} = 6.8333 [mathin] and [mathin] \lambda_{ew} = 51.522 [mathin]. The web ratio, 51.52/115 = 0.45, is higher than the flange’s, 6.83/16 = 0.43, so the web sets the section slenderness, and the section is compact (Clause 5.2.3). Then [mathin] Z_{e} = 1.3971 \times 10^{6}\ \text{mm}^{3} [mathin]:
[math] \phi M_{s} = \phi\, f_{yb}\, Z_{e} = 0.9 \times (300\ \text{MPa}) \times (1.3971 \times 10^{6}\ \text{mm}^{3}) = 377.2\ \text{kN m} [math]
The axial tension capacity uses the net section at the flange holes and the nearest line of web holes:
[math] A_{nw} = 8012 – 3 \times 26 \times 9.1 = 7302.2\ \text{mm}^{2}, \quad \phi N_{t} = 0.9 \min\left( 9520 \times 300,\ 0.85 \times 7302.2 \times 440 \right) = 2457.9\ \text{kN} [math]
In compression the holes are filled. The web is slender in compression, [mathin] \lambda_{ew} = 51.522 > \lambda_{wy} = 45 [mathin], so its effective width is [mathin] b_{ew} = (45 / 51.522) \times 428\ \text{mm} = 373.82\ \text{mm} [mathin] (Clause 6.2.4), giving [mathin] A_{e} = 9027\ \text{mm}^{2} [mathin] and [mathin] k_{f} = 0.94821 [mathin]:
[math] \phi N_{s} = 0.9 \times 0.94821 \times (9520\ \text{mm}^{2}) \times (300\ \text{MPa}) = 2437.3\ \text{kN} [math]
Clause 8.3.2 then reduces the moment capacity for the axial tension and, separately, for the axial compression:
[math] \phi M_{rx,t} = \min\left[ 1.18\, \phi M_{s} \left( 1 – \frac{N_{t}^{*}}{\phi N_{t}} \right),\ \phi M_{s} \right] = \min\left[ 1.18 \times 377.2 \times \left( 1 – \frac{771.12}{2457.9} \right),\ 377.2 \right] = 305.46\ \text{kN m} [math]
[math] \phi M_{rx,c} = \phi M_{s} \left( 1 – \frac{N_{c}^{*}}{\phi N_{s}} \right) = 377.2 \times \left( 1 – \frac{771.12}{2437.3} \right) = 257.86\ \text{kN m} [math]
[math] \phi M_{rx} = \min\left( 305.46\ \text{kN m},\ 257.86\ \text{kN m} \right) = 257.86\ \text{kN m} [math]
DCR = 134.46 kN m / 257.86 kN m = 0.521 ≤ 1.0, OK
The report applies the 1.18 factor of Clause 8.3.2 to the tension case only, so the compression case governs here.
Step 11: Web plate detailing limitations (AS 4100 Clause 9.5)
The same 60 mm minimum pitch and 42 mm minimum edge distance apply. The maximum edge distance is 12 times the 10 mm web plate, 120 mm, and the web plates must fit on the flat of the beam web between the root radii, 405.2 mm. The report lists the 136.4 mm maximum row pitch as the software’s limit.
| Detailing limit (web plates) | Limit (mm) | Actual (mm) | DCR | Result |
|---|---|---|---|---|
| Minimum bolt row pitch on web plate | 60.000 | 75.000 | 0.800 | PASS |
| Maximum bolt row pitch on web plate | 136.400 | 75.000 | 0.550 | PASS |
| Minimum vertical edge distance on web plate | 42.000 | 45.000 | 0.933 | PASS |
| Minimum horizontal edge distance on web plate | 42.000 | 45.000 | 0.933 | PASS |
| Minimum horizontal edge distance on beam web | 42.000 | 45.000 | 0.933 | PASS |
| Maximum edge distance | 120.000 | 45.000 | 0.375 | PASS |
| Maximum web plate depth | 405.200 | 240.000 | 0.592 | PASS |
[math] DCR = \frac{42\ \text{mm}}{45\ \text{mm}} = 0.93333 [math]
DCR = 42 mm / 45 mm = 0.933 ≤ 1.0, OK
Step 12: Web bolt group in shear (AS 4100 Clauses 9.1.4, 9.1.3, 9.2.2.1 and 9.3.1)
Clause 9.1.4 also sets a minimum design shear for the splice, 0.15 times the shear capacity of the beam, but not less than 40 kN:
[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{b}\, t_{wb} = 0.9 \times 0.6 \times (300\ \text{MPa}) \times (457\ \text{mm}) \times (9.1\ \text{mm}) = 673.71\ \text{kN} [math]
[math] V_{min}^{*} = \max\left( 0.15 \times 673.71\ \text{kN},\ 40\ \text{kN} \right) = 101.06\ \text{kN}, \quad V_{w}^{*} = \max\left( 150\ \text{kN},\ 101.06\ \text{kN} \right) = 150\ \text{kN} [math]
The web takes its share of the axial force, [mathin] k_{w} = 0.41413 [mathin], in tension and in compression:
[math] N_{wt}^{*} = N_{wc}^{*} = 0.41413 \times (771.12\ \text{kN}) = 319.34\ \text{kN} = N_{w}^{*} [math]
[math] R_{w}^{*} = \sqrt{V_{w}^{*2} + N_{w}^{*2}} = \sqrt{150^{2} + 319.34^{2}} = 352.82\ \text{kN} [math]
The resultant acts at 64.84° from the horizontal. Either sense of the axial force gives the same result, as the bolt group is symmetric. Each bolt passes through both web plates, so it is in double shear:
[math] \phi V_{f} = 0.8 \times 0.62 \times (830\ \text{MPa}) \times 1 \times 1 \times \left( 2 \times 324\ \text{mm}^{2} + 0 \right) = 266.77\ \text{kN} [math]
The bolt group capacity is found by the instantaneous centre of rotation method. The resultant acts at the centre of the splice, at [mathin] e_{d} = c/2 + l_{eh\_w} = 12\ \text{mm} / 2 + 45\ \text{mm} = 51\ \text{mm} [mathin] from the line of web bolts. The bolt coordinates:
| Bolt | x (mm) | y (mm) |
|---|---|---|
| 1 | 0.00 | 0.00 |
| 2 | 0.00 | 75.00 |
| 3 | 0.00 | 150.00 |
The instantaneous centre, found by iteration, is at [mathin] x_{ic} = -26.456\ \text{mm} [mathin] and [mathin] y_{ic} = 163.1\ \text{mm} [mathin] from bolt 1. The bolt reactions are:
| Bolt | R (kN) | Rx (kN) | Ry (kN) | Mn (kN-mm) |
|---|---|---|---|---|
| 1 | 261.83 | 258.46 | 41.92 | 43263.59 |
| 2 | 243.85 | 233.55 | 70.14 | 22431.02 |
| 3 | 173.00 | 76.77 | 155.03 | 5107.69 |
[math] \sum R_{x} = 568.78\ \text{kN}, \quad \sum R_{y} = 267.09\ \text{kN}, \quad \phi V_{df} = \sqrt{568.78^{2} + 267.09^{2}} = 628.37\ \text{kN} [math]
[math] C = \frac{\phi V_{df}}{\phi V_{f}} = \frac{628.37}{266.77} = 2.3555 [math]
DCR = 352.82 kN / 628.37 kN = 0.561 ≤ 1.0, OK
Step 13: Web bolts in bearing on the web plates and beam web (AS 4100 Clauses 9.2.2.4 and 9.3.1)
The bolt forces from the ICOR analysis act in different directions, so the least distance in either direction governs each ply. For the web plates the distances are 44 mm to the plate edges, 61 mm to the adjacent hole and 88 mm to the hole across the splice, so 44 mm governs. Each bolt bears on both web plates:
[math] \phi V_{b,wp} = 2 \times 0.9 \min\left( 3.2 \times 24 \times 10 \times 430,\ 44 \times 10 \times 430 \right) = 340.56\ \text{kN} [math]
For the beam web the distances are 44 mm to the beam end and 61 mm to the adjacent hole:
[math] \phi V_{b,w} = 0.9 \min\left( 3.2 \times 24 \times 9.1 \times 440,\ 44 \times 9.1 \times 440 \right) = 158.56\ \text{kN} [math]
[math] \phi V_{b} = \min\left( \phi V_{b,wp},\ \phi V_{b,w} \right) C = 158.56\ \text{kN} \times 2.3555 = 373.48\ \text{kN} [math]
DCR = 352.82 kN / 373.48 kN = 0.945 ≤ 1.0, OK
This is the governing check of the splice. The 9.1 mm beam web is the thinnest ply, and the end distance of 45 mm to the beam end limits its bearing capacity.
Step 14: Web plates in tension (AS 4100 Clauses 7.2 and 9.1.10)
[math] A_{g} = 2 \times 240\ \text{mm} \times 10\ \text{mm} = 4800\ \text{mm}^{2}, \quad A_{n} = 2 \left( 240\ \text{mm} – 3 \times 26\ \text{mm} \right) \times 10\ \text{mm} = 3240\ \text{mm}^{2} [math]
[math] \phi N_{t} = 0.9 \min\left( 4800 \times 310,\ 0.85 \times 1 \times 3240 \times 430 \right) = 1065.8\ \text{kN} [math]
DCR = 319.34 kN / 1065.8 kN = 0.300 ≤ 1.0, OK
Step 15: Web plates in compression (AS 4100 Clauses 6.2 and 6.3)
The bolt holes are filled, so no reduction is made for the holes:
[math] \phi N_{s} = 0.9 \times 1 \times (4800\ \text{mm}^{2}) \times (310\ \text{MPa}) = 1339.2\ \text{kN} [math]
[math] l_{e} = 1.2 \times 102\ \text{mm} = 122.4\ \text{mm}, \quad r = \frac{10\ \text{mm}}{\sqrt{12}} = 2.8868\ \text{mm}, \quad \lambda_{n} = 47.215 [math]
[math] \alpha_{a} = 19.906, \quad \alpha_{b} = 0.5, \quad \lambda = 57.168, \quad \eta = 0.14236, \quad \xi = 1.9156, \quad \alpha_{c} = 0.82421 [math]
[math] \phi N_{c} = \alpha_{c}\, \phi N_{s} = 0.82421 \times 1339.2\ \text{kN} = 1103.8\ \text{kN} [math]
DCR = 319.34 kN / 1103.8 kN = 0.289 ≤ 1.0, OK
Step 16: Web plates in bending (AS 4100 Clauses 9.1.3, 5.2 and 8.3.2)
[math] M_{w}^{*} = V_{w}^{*}\, e_{d} = 150\ \text{kN} \times 51\ \text{mm} = 7.65\ \text{kN m} [math]
[math] S_{i} = \frac{10 \times 240^{2}}{4} = 144000\ \text{mm}^{3}, \quad Z_{i} = \frac{10 \times 240^{2}}{6} = 96000\ \text{mm}^{3} [math]
The plate slenderness is [mathin] \lambda_{s} = 26.725 \le \lambda_{sp} = 82 [mathin], so the plate is compact and [mathin] Z_{ei} = 144000\ \text{mm}^{3} [mathin].
[math] \phi M_{wd} = 2 \times 0.9 \times (310\ \text{MPa}) \times (144000\ \text{mm}^{3}) = 80.352\ \text{kN m} [math]
[math] \phi M_{wr,t} = 80.352 \times \left( 1 – \frac{319.34}{1065.8} \right) = 56.276\ \text{kN m}, \quad \phi M_{wr,c} = 80.352 \times \left( 1 – \frac{319.34}{1339.2} \right) = 61.191\ \text{kN m} [math]
DCR = 7.65 kN m / 56.276 kN m = 0.136 ≤ 1.0, OK
Step 17: Web plates in shear (AS 4100 Clauses 5.11.3 and 5.12.3)
[math] \phi V_{vd} = 2 \times 0.9 \times 0.5 \times (310\ \text{MPa}) \times (240\ \text{mm}) \times (10\ \text{mm}) = 669.6\ \text{kN} [math]
Under Clause 5.12.3, [mathin] M_{w}^{*} = 7.65\ \text{kN m} \le 0.75\, \phi M_{wd} = 60.26\ \text{kN m} [mathin], so the shear capacity is not reduced for bending.
DCR = 150 kN / 669.6 kN = 0.224 ≤ 1.0, OK
Step 18: Web plates in block shear (AS 4100 Clause 9.1.9)
[math] A_{nt} = \left[ 45 – 13 \right] \times 10 = 320\ \text{mm}^{2}, \quad A_{gv} = \left[ 45 + 150 \right] \times 10 = 1950\ \text{mm}^{2}, \quad A_{nv} = \left[ 195 – 65 \right] \times 10 = 1300\ \text{mm}^{2} [math]
[math] \phi R_{bs} = 2 \times 0.75 \min\left( 0.6 \times 430 \times 1300 + 430 \times 320,\ 0.6 \times 310 \times 1950 + 430 \times 320 \right) = 709.5\ \text{kN} [math]
DCR = 150 kN / 709.5 kN = 0.211 ≤ 1.0, OK
Step 19: Web plates in block shear under axial tension (AS 4100 Clause 9.1.9)
[math] A_{gv} = 2 \times 45 \times 10 = 900\ \text{mm}^{2}, \quad A_{nv} = 2 \times 32 \times 10 = 640\ \text{mm}^{2} [math]
[math] A_{nt,1} = \left[ 150 – 52 \right] \times 10 = 980\ \text{mm}^{2}, \quad \phi R_{bs,1} = 879.78\ \text{kN}; \quad A_{nt,2} = \left( 90 – 26 \right) \times 10 = 640\ \text{mm}^{2}, \quad \phi R_{bs,2} = 660.48\ \text{kN} [math]
DCR = 319.34 kN / 660.48 kN = 0.484 ≤ 1.0, OK
Step 20: Beam web in block shear under axial tension (AS 4100 Clause 9.1.9)
[math] A_{gv} = 2 \times 45 \times 9.1 = 819\ \text{mm}^{2}, \quad A_{nv} = 582.4\ \text{mm}^{2}, \quad A_{nt} = \left[ 150 – 52 \right] \times 9.1 = 891.8\ \text{mm}^{2} [math]
[math] \phi R_{bs} = 0.75 \min\left( 0.6 \times 440 \times 582.4 + 440 \times 891.8,\ 0.6 \times 300 \times 819 + 440 \times 891.8 \right) = 404.86\ \text{kN} [math]
DCR = 319.34 kN / 404.86 kN = 0.789 ≤ 1.0, OK
Summary of checks
The results for the left beam are below. The right beam gives the same values.
| Design check | Design action effect | Design capacity | DCR | Result |
|---|---|---|---|---|
| Flange: detailing limitations | 42 mm | 45 mm | 0.933 | PASS |
| Flange: bolt group in shear | 529.753 kN | 800.306 kN | 0.662 | PASS |
| Flange: bolt bearing on flange plate and beam flange | 529.753 kN | 1906.34 kN | 0.278 | PASS |
| Flange plate in block shear | 529.753 kN | 897.84 kN | 0.590 | PASS |
| Beam flange in block shear | 529.753 kN | 1100.55 kN | 0.481 | PASS |
| Flange plate in tension | 529.753 kN | 673.69 kN | 0.786 | PASS |
| Flange plate in compression | 529.753 kN | 716.945 kN | 0.739 | PASS |
| Beam flange in tension | 529.753 kN | 673.537 kN | 0.787 | PASS |
| Beam flange in compression | 529.753 kN | 743.85 kN | 0.712 | PASS |
| Beam section moment capacity at the flange holes | 134.46 kN m | 257.862 kN m | 0.521 | PASS |
| Web: detailing limitations | 42 mm | 45 mm | 0.933 | PASS |
| Web: bolt group in shear | 352.817 kN | 628.371 kN | 0.561 | PASS |
| Web: bolt bearing on web plates and beam web | 352.817 kN | 373.483 kN | 0.945 | PASS |
| Web plates in tension | 319.343 kN | 1065.8 kN | 0.300 | PASS |
| Web plates in compression | 319.343 kN | 1103.78 kN | 0.289 | PASS |
| Web plates in bending | 7.65 kN m | 56.2763 kN m | 0.136 | PASS |
| Web plates in shear | 150 kN | 669.6 kN | 0.224 | PASS |
| Web plates in block shear | 150 kN | 709.5 kN | 0.211 | PASS |
| Web plates in block shear under axial tension | 319.343 kN | 660.48 kN | 0.484 | PASS |
| Beam web in block shear under axial tension | 319.343 kN | 404.859 kN | 0.789 | PASS |
The splice passes every check. The web bolts in bearing on the beam web govern at 0.945, followed by the detailing limits at 0.933 and the beam web in block shear at 0.789. Every flange and web force here comes from the raised Clause 9.1.4 minimums, not the 80 kN m and 450 kN entered.
Auto Design is available for the beam splice with flange and web plates in the AS 4100 module. It changes the bolts and plates until every check passes, and keeps your beams and design actions as entered. See the Auto Design page for the AS 4100 preferences it works to.
What to change if a check fails
- Detailing limits: adjust the pitch, gauge or edge distances to the limits in Steps 1 and 11.
- Web bolt bearing: add a bolt row to the web plates, which raises C, or use a larger bolt. In this example the beam web governs, so thicker web plates alone do not help.
- Flange bolt group: add bolt rows, or use a larger bolt or a higher grade.
- Flange plate in tension, compression or block shear: use a wider or thicker flange plate. A thicker plate also lowers its slenderness across the gap.
- Beam flange or beam web checks, or the moment at the holes: these depend on the beam, so reduce the holes (smaller bolts or fewer per row) or use a heavier section.
- Web plates: use thicker or deeper plates, within the flat of the web.
Frequently asked questions
Why is the design moment 134.46 kN m when 80 kN m was entered?
Clause 9.1.4 asks for a splice in a flexural member to be designed for at least 0.3 times the design section moment capacity. For the 460 UB 74.6 that is 0.3 x 0.9 x 300 MPa x 1.66 x 10⁶ mm³ = 134.46 kN m. The axial forces are raised the same way, from 450 kN to 771.12 kN.
Why are there compression checks on the plates?
The beam ends have a 12 mm gap, so they do not bear on each other. The compression flange force passes through the flange plate, which acts as a short strut across the gap between the bolt rows either side of the splice. The web plates are checked the same way for the web share of the axial compression.
Why are the web bolts designed for a 51 mm eccentricity?
The web shear is taken at the centre of the splice: half the 12 mm gap plus the 45 mm from the beam end to the web bolts. The instantaneous centre method finds a coefficient C of 2.3555 for the three bolts under the combined shear, axial force and moment.
Why does the beam moment capacity use reduced section moduli?
Clause 5.2.6 allows the gross section moduli only when the holes take out a small enough part of the flange. Two 26 mm holes in a 190 mm flange remove 27.4% of it, more than the 19.8% limit for this steel, so the moduli are scaled down by the net-to-gross area ratio.
Design a beam splice for free
Every number on this page comes from one solve. Pick AS 4100:2020 and the beam splice, enter your beams, plates, bolts and design actions, and see each of these checks in your browser. There is nothing to install.
The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every design capacity and DCR, for AS 4100:2020 shear connections, moment connections and splices. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.
References
- AS 4100:2020, Steel Structures: Clauses 4.6.3.2, 5.2.1, 5.2.2, 5.2.3, 5.2.6, 5.11.2, 5.11.3, 5.12.3, 6.2.1, 6.2.2, 6.2.4, 6.3.2, 6.3.3, 7.2, 7.3, 8.3.2, 9.1.3, 9.1.4, 9.1.9, 9.1.10, 9.2.2.1, 9.2.2.4, 9.3.1, 9.5; Tables 5.2, 6.3.3(A) and 9.5.2.
- Design of steel connections using AS 4100:2020
- Auto Design in SkyCiv Connection Design