SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

Auto Design

Auto Design sizes a connection for you. It works on the connection you have open: it keeps your members, member grades, loads and the connection type you chose, and searches the bolts, plates and welds for a design that passes every check and has no clashes. Of the passing designs it finds, it picks the cheapest one under SkyCiv’s fabrication cost model.

Treat the result as a recommendation. It is a starting point that passes the checks, and you still need to apply your own engineering judgement before you sign it off.

Where Auto Design is available

Auto Design runs on AISC 360-16 and AISC 360-22 (LRFD and ASD, Imperial or Metric units) and on AS 4100:2020. The Auto Design button only appears on the Results tab for the connections it supports.

AISC 360-16 and AISC 360-22

  • Shear, I to I: single plate, double plate, single angle, double angle, end plate and directly welded web, to a column flange, a column web or a girder web
  • Shear plus axial, I to I: single plate, double angle, end plate and directly welded web, to a column flange or a column web
  • Moment, I to I: flange plate (column flange or column web), flush end plate and extended end plate (column flange)
  • Splices: beam splice and column splice with flange and web plates
  • Channel to channel, shear: single plate and directly welded web
  • HSS to I: single plate in shear and in shear plus axial, and the flange plate moment connection, to the wide or narrow face of the HSS column
  • Bracing: knee brace and chevron brace with a directly welded gusset plate; vertical brace (lower, upper, or lower and upper) with a single plate, double angle, end plate or directly welded connection to the column flange or web; horizontal brace with a single plate or single angle connection to the support, with or without a column

AS 4100:2020

  • Shear: web side plate, flexible end plate, single angle and double angle, to a column flange, a column web or a girder web
  • Moment: bolted flange plate, to a column flange or a column web
  • Splices: beam splice and column splice with flange and web plates

The AS 4100 extended end plate, knee end plate and apex end plate connections do not have Auto Design.

When you open a supported connection, the Results tab shows the Auto Design button beside Run Design Checks.

Running Auto Design

Set up the connection as usual: the members and their grades on the Assembly tab, bolted or welded on each fixture where you have the choice, and the loads on the Loads tab. Then go to the Results tab.

On a connection Auto Design supports, the Results tab does not run the design checks by itself. You get two actions side by side:

  • Run Design Checks checks the connection exactly as you have detailed it.
  • Auto Design sizes the connection, then runs the design checks on the result.

The gear button next to Auto Design opens the Auto Design Preferences. The first time you run Auto Design on a connection type, the preferences open before the run starts, filled in with defaults. Check them and press Save & Run Auto Design. You are only asked once per connection type; after that, change them with the gear button. Pressing Cancel cancels the run.

Under the buttons you’ll see the note: "Auto Design picks the cheapest passing design under SkyCiv’s cost model. Treat it as a recommendation and apply your own engineering judgement."

Results tab before a run, with Run Design Checks, Auto Design and the preferences gear button

On the free plan, each Auto Design run uses one of your weekly solves, the same allowance your design checks use. The line under the button shows how many runs you have left. A run only counts once it starts solving, so cancelling the preferences dialog costs nothing.

Auto Design Preferences

The preferences are your shop standard: the bolts, holes, grades and minimum sizes Auto Design is allowed to use. They are saved in your browser, separately for each connection type and load type, so a single plate in shear and a single plate in shear plus axial each keep their own set. Reset to defaults puts a set back to SkyCiv’s defaults.

Each design code has its own preference set and its own dialog. Your AISC settings never affect your AS 4100 designs, and the other way round.

AISC (dialog title: Auto Design Preferences)

AISC Auto Design Preferences for a single plate: holes, bolts in order of preference, bolt rows and grades

The dialog only shows what applies to the connection you have open. Depending on the connection, it contains:

  • Holes, for each bolted interface: the hole type In the member and In the connector (for an end plate, In the support and In the end plate; for angles, In the angle). Some hole types take slip-critical bolts only, and while one of those is selected, the bolt grades below only offer slip-critical grades.
  • Bolts, in order of preference: a list of Diameter and Grade. Use Add a bolt option to add more, and the arrows to reorder them. Auto Design tries every bolt you list and picks the cheapest passing design. When two designs come out nearly the same, the bolt higher in the list wins.
  • Bolt detailing: Spacing and Edge distance (named Pitch and Edge on an end plate, and Spacing and Vertical edge on angles), each Flexible or Fixed. Flexible lets Auto Design choose the value for the cheapest design. Fixed uses the value you give for every bolt group. A fixed value is used as given, even below the AISC minimum for the bolt; the detailing check then reports it. On the moment end plates there is also Bolt to flange (pf).
  • Set a minimum number of bolt rows by beam size?: answer Yes to set a minimum number of bolt rows for each beam depth. Where a deep cope leaves no room for the minimum, Auto Design uses the most rows that fit.
  • Angles, in order of preference (angle connections only): the angle sizes Auto Design may use. Use Add an angle to add more. An unequal angle is tried both ways round.
  • Grades: the plate grade Up to a thickness, and the grade for Thicker plates, plus the weld Electrode.
  • Minimum sizes: Minimum plate, Minimum weld and, on the brace connections, Gusset extension (the least distance from the end of each brace to the edge of the gusset).

On a directly welded connection, the only preference is the weld electrode.

AISC Auto Design Preferences for a double angle, with the angles in order of preference and Add an angle

The Take the tour button at the top of the dialog starts the guided tour (see below).

AS 4100 (dialog title: Auto Design Preferences (AS 4100))

Auto Design Preferences (AS 4100) for a web side plate: bolts, bolt holes, materials and weld category

  • Bolts, in order of preference: Diameter (M12 to M36), Bolting category (4.6/S, 8.8/S, 8.8/TB, 8.8/TF, 10.9/S, 10.9/TB, 10.9/TF, or Custom with its fuf) and Threads in shear plane (YES or NO). Auto Design tries the bolts in this order and keeps the cheapest design of the first one that passes.
  • Bolt holes, for each bolt group: Member and Connector, each Nominal, Short-Slotted or Oversized where the connection allows them. An oversize hole, or a short slot not normal to the load, makes the bolts friction type (/TF), as the bolt panels do.
  • Materials: Plate grade, Angle grade (angle cleats), Weld electrode and Weld category (SP or GP).
  • Minimum sizes: Minimum plate thickness and Minimum fillet weld.
  • Bolt detailing: Pitch and Edge distance (Vertical edge distance on angle cleats), each Flexible or Fixed. A value below the AS 4100 minimum for the bolt and holes is raised to it.
  • Set a minimum number of bolt rows by beam size?: one minimum for each AS nominal depth series. This is a shop rule, not an AS 4100 clause.

The AS 4100 defaults are M20 then M24 8.8/S bolts with threads included, nominal holes, AS/NZS 3678 Gr.250 plate, AS/NZS 3679.1 Gr.300 angles, E49XX SP welds, 6 mm minimum plate and fillet weld, and a fixed 70 mm pitch and 35 mm edge distance.

What Auto Design changes and what it keeps

Auto Design never changes:

  • the member sections and member grades
  • the loads, whether envelope or load combinations, and your utility ratio limit
  • the connection type you chose
  • the hole types (it uses the ones in your preferences)
  • the choice of bolted or welded on each fixture, unless you agree to a switch (see below)
  • the brace slopes on a bracing connection

What it does change, within your preferences: the bolt layout, spacing, edge distances, diameter and grade; the plate sizes and thicknesses; the angle sizes; the weld sizes and electrode. On a beam to column web connection it can also set the beam setback to clear the column flanges.

Copes are kept as you set them. The one exception: if a coped single plate to a girder web cannot pass, Auto Design can switch it to an extended single plate, with the beam set back past the girder flange tips so that it needs no cope. When it does this, it tells you why ("Extended Single Plate Chosen") and lists the new setback.

On angle connections, if none of the angles in your list passes, Auto Design can choose an angle that isn’t on the list, and it explains the choice.

Load combinations and the utility ratio limit

Auto Design designs for the loads exactly as you set them on the Loads tab, in either mode:

  • Envelope: the connection is sized for the envelope row.
  • Load Combinations: every candidate design is checked against each load combination with its own signs. A design is only accepted when it passes every combination.

It also designs to your Utility ratio limit. The strength checks are held to that limit and the ductility and detailing checks stay at 1.00, just as in a normal design check run. See Loads and Load Combinations for how both work.

Reviewing the result

When Auto Design finds a passing design, it applies it, reloads the connection and runs the design checks on it. A card at the top of the Results tab, titled "Auto Design changed n settings", lists every setting it changed as before → after, grouped by part (plate, bolts, weld, beam setback and copes).

Auto Design changed 5 settings card listing each change as before and after, with Keep changes and Undo changes

  • Keep changes closes the card and keeps the new design.
  • Undo changes brings back your design from before the run. If you have edited the connection since the run, you are asked to confirm first, because those edits will be lost.

If your design already passed and was already the most economical passing design, the card says "Auto Design: nothing to change" and you just press OK.

When a run doesn’t end with a passing design, a dialog tells you what happened:

  • Passes With a Different Fixture Type: the design could not pass with the bolted/welded choices you made, but it passes with one fixture changed. Choose Use this design or Keep my design. This is offered on AISC single plate, single angle and double angle connections. A weld is only proposed in place of bolts where that fixture is shop work, never in place of a field bolt.
  • Auto Design Incomplete — Checks Still Failing: Auto Design applied the best design it found, but some checks still fail. The dialog names the governing check and lists the changes it applied. The results shown are for that design.
  • Could Not Reach a Passing Design: nothing was applied. Usually a check fails that no change to the connection can fix, such as the beam itself not carrying the shear. In that case, change the members or the loads.
  • No Buildable Connection Found: the design could not be built as detailed, for example because of a clash. Nothing was applied.

Guided tour

When you pick a connection that supports Auto Design, the app offers a short walkthrough ("Auto Design Is Available"). Choose Show me, Not now, or Don’t ask again.

The tour highlights one control at a time and waits while you change it: the member sizes and grades, bolted or welded for each fixture that has the choice, Envelope or Load Combinations (where the connection takes load combinations), the loads, the utility ratio limit, and the Auto Design Preferences. Use Next, Back or Skip tour to move through it. Got it on the last step runs Auto Design. Skipping the tour never runs it.

You can take the tour again at any time from Take the tour in the Auto Design Preferences.

Try it now

Pick a supported connection, enter your members and loads, and press Auto Design on the Results tab. You can do it without an account.

Sign-up to Free Account

A free account lets you save and reload your connection files, which the free tool does not. It also gives you access to the rest of SkyCiv’s structural software, including Structural 3D.

Connection Design Standalone

Want to use the connection design module only? Click the button below for the standalone pricing.

How can we help?

×