SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

Knee End Plate Connection Design to AS 4100

To design a knee end plate connection to AS 4100, you treat it as an extended end plate moment connection with the rafter meeting the plate at its slope. The moment becomes a force pair at the rafter flanges, and the shear and axial load are resolved along and across the plate. The flange forces are then followed through the welds, the end plate, the tension bolts and the column flange and web. The slope adds three things to the straight connection: skewed fillet welds at the flanges, a share of the shear in the flange forces, and longer lever arms on the bolts.

This page works through one example from start to finish: a 410 UB 53.7 rafter at a 15° slope joined to the flange of a 310 UC 158 column with a 28 mm Grade 250 end plate and eight M24 8.8/TB bolts, designed to AS 4100:2020 for a moment of 158 kNm, a shear of 49 kN and an axial compression of 15 kN. Every equation is written out with its numbers, in the same order as the calculation report that the SkyCiv Connection Design module produces for it. The scope and conventions of the AS 4100 module are on the design of steel connections using AS 4100:2020 page.

What is a knee end plate connection?

A knee end plate connection joins a sloping rafter to the flange of a column, as at the eaves of a portal frame. The end plate is cut square to the column and fillet welded to the end of the rafter, which meets it at the roof slope. On site it is bolted to the column flange. The connection is rigid: it carries the moment at the knee, and the shear and axial load in the rafter.

This example uses the four-bolt extended form, 4E: one row of two bolts above the top flange and one row below it, so the extension of the plate above the rafter carries half the tension flange force. You can check this one directly in the end plate connection calculator, and the module’s other moment connections cover the straight beam to column cases.

Knee end plate elevation: 410 UB 53.7 rafter at 15 degrees on a 28 mm end plate bolted to a 310 UC 158 flange

Elevation of the example connection. Each flange has an 8 mm fillet on the acute side of the joint and a 10 mm fillet on the obtuse side.

Section A-A of the knee end plate: 28 mm Gr.250 plate with eight M24 8.8/TB bolts at a 130 mm gauge

Section A-A through the end plate, showing the four-bolt extended layout and the bolt rows 65 mm from each flange.

SkyCiv Connection Design 3D view of a knee end plate connection, a 15 degree 410 UB 53.7 rafter to a 310 UC 158

The same connection in the 3D view of SkyCiv Connection Design.

Knee end plate connection design: the steps at a glance

  1. Check the detailing limits: gauge, pitch, edge distances, plate width and weld size.
  2. Set the design moment, not less than the Clause 9.1.4 minimum, find the flange forces, and check the flange welds.
  3. Check the web welds in tension and in shear.
  4. Check the tension bolts, then the bolt group in shear and in bearing.
  5. Check the end plate in bending and its extension in shear.
  6. Check the column flange in bending at the tension flange.
  7. Check the column web at both flanges: yield, bearing yield, crippling and bearing buckling.
  8. Check the column web panel in shear.

Design inputs for this example

The design code is AS 4100:2020, with section properties from the Australian section database. The yield strength of each part follows its grade and thickness (Table 2.1): 320 MPa for the 10.9 mm flanges of the rafter, 280 MPa for the 25 mm column flange, 300 MPa for the 15.7 mm column web, and 250 MPa for the 28 mm end plate.

ItemSymbolValue
Shear (Fy)[mathin] V^{*} [mathin]49 kN
Axial (Fx), compression[mathin] N^{*}_{c} [mathin]15 kN
Major axis moment (Mz)[mathin] M^{*}_{x} [mathin]158 kNm
Rafter slope at the end plate[mathin] \theta [mathin]15°
Rafter410 UB 53.7, AS/NZS 3679.1 Gr.300
Depth / web thickness[mathin] d_{bm},\ t_{wb} [mathin]403 mm / 7.6 mm
Flange width / thickness[mathin] b_{fb},\ t_{fb} [mathin]178 mm / 10.9 mm
Root radius / plastic section modulus[mathin] r_{b},\ S_{x} [mathin]11.4 mm / 1.06 x 10⁶ mm³
Yield / tensile strength[mathin] f_{yb},\ f_{ub} [mathin]320 MPa / 440 MPa
Column310 UC 158, AS/NZS 3679.1 Gr.300
Column depth / web thickness[mathin] d_{sup},\ t_{ws} [mathin]327 mm / 15.7 mm
Column flange width / thickness[mathin] b_{fs},\ t_{fs} [mathin]311 mm / 25 mm
Column root radius[mathin] r_{s} [mathin]16.5 mm
Column flange / web yield strength[mathin] f_{ycf},\ f_{ycw} [mathin]280 MPa / 300 MPa
Column tensile strength / elastic modulus[mathin] f_{us},\ E [mathin]440 MPa / 200000 MPa
End plate, bolts and weldsSymbolValue
End platePL 28 x 220 x 637.22, AS/NZS 3678 Gr.250
Plate thickness / width / depth[mathin] t_{i},\ b_{i},\ d_{i} [mathin]28 mm / 220 mm / 637.22 mm
Plate yield / tensile strength[mathin] f_{yi},\ f_{ui} [mathin]250 MPa / 410 MPa
Bolts8 x M24 8.8/TB, threads included in the shear plane
Bolt diameter / minimum tensile strength[mathin] d_{f},\ f_{uf} [mathin]24 mm / 830 MPa
Holes in plate and column flange[mathin] d_{h} [mathin]Nominal, 26 mm
LayoutForm 4E: one row outside and one row inside each flange, 2 bolts per row
Bolt gauge[mathin] s_{g} [mathin]130 mm
Bolt row to flange face[mathin] s_{po} [mathin]65 mm
End plate edge distances (vertical / horizontal)[mathin] a_{e},\ l_{eh\_ep} [mathin]45.002 mm / 45 mm
Flange and web welds8 mm fillets both sides, E49XX, SP
Weld size / weld metal strength[mathin] t_{wf},\ t_{ww},\ f_{uw} [mathin]8 mm / 8 mm / 490 MPa

The end plate is 637.22 mm deep, more than for the straight connection, because the rafter depth measured along the plate grows with the slope. The bolt rows sit 65 mm from the flange faces and the plate edges 45 mm beyond the outer rows.

Step 1: Connection detailing limitations (AS 4100 Clause 9.5)

The bolt layout has to be buildable and match the assumptions behind the capacity equations. For M24 bolts the minimum edge distance is 42 mm, 1.75 times the bolt diameter (Table 9.5.2), and the minimum pitch is 2.5 times the diameter, 60 mm (Clause 9.5.1). The minimum fillet weld size for the parts joined is 6 mm (Table 9.6.3.2). The wrench clearance, flange to bolt row and end plate width limits are the software’s limits for this layout.

Detailing limitLimit (mm)Actual (mm)DCRResult
Minimum bolt gauge60.000130.0000.462PASS
Maximum bolt gauge178.000130.0000.730PASS
Minimum bolt pitch across the tension flange60.000141.2850.425PASS
Minimum vertical edge distance on end plate42.00045.0020.933PASS
Minimum horizontal edge distance on end plate42.00045.0000.933PASS
Minimum horizontal edge distance on column flange42.00090.5000.464PASS
Maximum edge distance150.00045.0020.300PASS
Minimum bolt gauge for wrench clearance73.600130.0000.566PASS
Minimum flange to bolt row distance35.00065.0000.538PASS
Minimum flange to bolt row distance for the bolt length at a sloping flange52.34965.0000.805PASS
Minimum end plate width198.000220.0000.900PASS
Maximum end plate width331.000220.0000.665PASS
Minimum fillet weld size at beam flange to end plate (acute side)6.0008.0000.750PASS
Minimum fillet weld size at beam web to end plate6.0008.0000.750PASS

For a minimum limit the ratio is limit over actual, and for a maximum it is actual over limit. The governing row is the horizontal edge distance on the end plate:

[math] DCR = \frac{42\ \text{mm}}{45\ \text{mm}} = 0.933 [math]

DCR = 0.933 ≤ 1.0, OK

The sloping flange row is new for the knee. At a slope, the bolt head or nut next to the flange is closer to the flange on the acute side, so the bolt row needs more room from the flange face. Here it needs 52.349 mm and has 65 mm.

Step 2: Beam flange welds (AS 4100 Clauses 9.1.4, 9.6.3.10)

Design moment and flange forces

The connection is rigid, so Clause 9.1.4 sets the design moment at not less than half the design section moment capacity of the rafter:

[math] M^{*} = \max\left( M^{*}_{x},\ 0.5\, \phi\, f_{yb}\, S_{x} \right) = \max\left( 158\ \text{kNm},\ 0.5 \times 0.9 \times (320\ \text{MPa}) \times (1.06 \times 10^{6}\ \text{mm}^{3}) \right) = \max\left( 158\ \text{kNm},\ 152.64\ \text{kNm} \right) = 158\ \text{kNm} [math]

The 158 kNm from the analysis is above the minimum, so it is used. The flange force from the moment acts over the distance between the flange centres:

[math] N^{*}_{tm} = \frac{M^{*}}{d_{bm} – t_{fb}} = \frac{158\ \text{kNm}}{403\ \text{mm} – 10.9\ \text{mm}} = 402.96\ \text{kN} [math]

The flange welds take the flange force along the rafter, half the axial compression, and the flange share of the shear component across the plate. With the slope of 15°, sin 15° = 0.25882:

[math] N^{*}_{fw} = N^{*}_{tm} + 0.5\, N^{*}_{c} + 0.5\, V^{*} \left| \sin\theta \right| = 402.96\ \text{kN} + 0.5 \times (15\ \text{kN}) + 0.5 \times (49\ \text{kN}) \times (0.25882) = 416.8\ \text{kN} [math]

Skewed fillet welds at the sloping flange

The rafter meets the end plate at 15°, so on each flange one fillet weld is on the acute side of the joint and the other on the obtuse side (Figure 9.6.3.1(d) and (e)). Each is an equal leg fillet sized to give the same design throat thickness as the straight 8 mm fillet (Clause 9.6.3.4):

[math] t_{w,a} = \frac{t_{wf} \cos 45^{\circ}}{\cos\left( \frac{90^{\circ} – \theta}{2} \right)} = \frac{(8\ \text{mm}) \cos 45^{\circ}}{\cos 37.5^{\circ}} = 7.1303\ \text{mm}, \qquad t_{w,o} = \frac{t_{wf} \cos 45^{\circ}}{\cos\left( \frac{90^{\circ} + \theta}{2} \right)} = \frac{(8\ \text{mm}) \cos 45^{\circ}}{\cos 52.5^{\circ}} = 9.2924\ \text{mm} [math]

Rounded up to a whole millimetre (Clause 9.6.3.1), the specified legs are 8 mm on the acute side and 10 mm on the obtuse side. The welds are then designed as the straight 8 mm fillet they are equivalent to.

Weld capacity

The welds are Structural Purpose (SP), so the capacity factor is 0.8 from Table 3.4:

[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{wf} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (8\ \text{mm}) = 1.3305\ \text{kN/mm} [math]

The flange welds run along both faces of the flange, less the web and the root radii:

[math] L_{wf} = 2\, b_{fb} – t_{wb} – 2\, r_{b} = 2 \times (178\ \text{mm}) – 7.6\ \text{mm} – 2 \times (11.4\ \text{mm}) = 325.6\ \text{mm} [math]

[math] \phi N_{w} = \phi v_{w}\, L_{wf} = (1.3305\ \text{kN/mm}) \times (325.6\ \text{mm}) = 433.21\ \text{kN} [math]

[math] N^{*}_{fw} = 416.8\ \text{kN} \le \phi N_{w} = 433.21\ \text{kN} [math]

DCR = 416.8 kN / 433.21 kN = 0.962 ≤ 1.0, OK

This is the governing strength check. The flange weld length is fixed by the flange width, so the way to add capacity is a larger fillet or a complete penetration butt weld.

Step 3: Beam web welds in tension (AS 4100 Clauses 7.2, 9.6.3.10)

The web welds on the tension side of the neutral axis are designed to develop the design yield capacity of that part of the web, so that the web can yield before the welds fail. The weld length on the tension side runs from mid-depth to the root radius, measured along the sloping plate:

[math] L_{wt} = \frac{0.5\, d_{bm} – t_{fb} – r_{b}}{\cos\theta} = \frac{0.5 \times (403\ \text{mm}) – 10.9\ \text{mm} – 11.4\ \text{mm}}{0.96593} = 185.52\ \text{mm} [math]

[math] \phi N_{wt} = \phi\, f_{ywb}\, t_{wb}\, L_{wt} = (0.9) \times (320\ \text{MPa}) \times (7.6\ \text{mm}) \times (185.52\ \text{mm}) = 406.07\ \text{kN} [math]

[math] \phi V_{wt} = 2\, \phi v_{w}\, L_{wt} = 2 \times (1.3305\ \text{kN/mm}) \times (185.52\ \text{mm}) = 493.67\ \text{kN} [math]

DCR = 406.07 kN / 493.67 kN = 0.823 ≤ 1.0, OK

The demand here is the web’s own yield capacity, not a force from the analysis, so the ratio does not change with the loads.

Step 4: Beam web welds in shear (AS 4100 Clauses 9.1.4, 9.6.3.10)

Clause 9.1.4 also sets a minimum design shear: the lesser of 0.15 times the rafter shear capacity, [mathin] 0.15 \times 529.25\ \text{kN} [mathin], and 40 kN, which is 40 kN. The 49 kN shear is larger and is used. The web welds on the compression side of the neutral axis carry the shear, taking its component along the plate:

[math] V^{*}_{vw} = V^{*} \cos\theta = (49\ \text{kN}) \times (0.96593) = 47.33\ \text{kN}, \qquad L_{wc} = 185.52\ \text{mm} [math]

[math] \phi V_{wc} = 2\, \phi v_{w}\, L_{wc} = 2 \times (1.3305\ \text{kN/mm}) \times (185.52\ \text{mm}) = 493.67\ \text{kN} [math]

DCR = 47.33 kN / 493.67 kN = 0.096 ≤ 1.0, OK

Step 5: Bolts at the tension flange (AS 4100 Clauses 9.1.8, 9.2.2.2, 9.3.2)

In the 4E form, two rows of two bolts take the tension: the row outside the tension flange and the row inside it. Their lever arms are measured to the centre of the compression flange, along the sloping plate: [mathin] d_{10} = 476.57\ \text{mm} [mathin] for the outer row and [mathin] d_{11} = 335.29\ \text{mm} [mathin] for the inner row, so [mathin] \Sigma d_{i} = 811.86\ \text{mm} [mathin].

The design tension capacity of one bolt, with the tensile stress area [mathin] A_{s} = 353\ \text{mm}^{2} [mathin] and a capacity factor of 0.8:

[math] \phi N_{tf} = \phi\, A_{s}\, f_{uf} = (0.8) \times (353\ \text{mm}^{2}) \times (830\ \text{MPa}) = 234.39\ \text{kN} [math]

The end plate and the column flange are made thick enough to keep the bolts free of prying (Clause 9.1.8, checked in Steps 8 and 11), so every tension bolt reaches its full capacity:

[math] \phi M_{bt} = 2\, \phi N_{tf}\, \Sigma d_{i} = 2 \times (234.39\ \text{kN}) \times (811.86\ \text{mm}) = 380.59\ \text{kNm} [math]

At the slope, the shear has a component across the plate that the tension flange takes as an extra tension force. It is taken as a moment on the bolts:

[math] N^{*}_{fr} = 0.5\, V^{*} \left| \sin\theta \right| = 0.5 \times (49\ \text{kN}) \times (0.25882) = 6.3411\ \text{kN} [math]

[math] M^{*}_{axial} = N^{*}_{fr} \left( d_{bm} – t_{fb} \right) = (6.3411\ \text{kN}) \times (403\ \text{mm} – 10.9\ \text{mm}) = 2.4863\ \text{kNm} [math]

[math] M^{*}_{bt} = \max\left( M^{*},\ 4\, M^{*}_{axial} \right) + M^{*}_{axial} = \max\left( 158\ \text{kNm},\ 9.9452\ \text{kNm} \right) + 2.4863\ \text{kNm} = 160.49\ \text{kNm} [math]

DCR = 160.49 kNm / 380.59 kNm = 0.422 ≤ 1.0, OK

Step 6: Bolt group in shear (AS 4100 Clause 9.2.2.1)

The bolts on the compression side of the neutral axis take the shear, so four of the eight bolts are counted. With the threads in the shear plane, the core area is used:

The shear on the bolts is the component of the shear along the plate plus the component of the axial compression along it:

[math] V^{*}_{v} = V^{*} \cos\theta + N^{*}_{c} \left| \sin\theta \right| = (49\ \text{kN}) \times (0.96593) + (15\ \text{kN}) \times (0.25882) = 51.213\ \text{kN} [math]

[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, A_{c} = (0.8) \times 0.62 \times (830\ \text{MPa}) \times (324\ \text{mm}^{2}) = 133.38\ \text{kN} [math]

[math] \phi V_{fb} = n_{cw}\, \phi V_{f} = 4 \times (133.38\ \text{kN}) = 533.54\ \text{kN} [math]

DCR = 51.213 kN / 533.54 kN = 0.096 ≤ 1.0, OK

Step 7: Bolt group in bearing on the end plate and the column flange (AS 4100 Clause 9.2.2.4)

On the end plate the bolt row nearest the edge governs, with [mathin] d_{h} = 26\ \text{mm} [mathin] (Clause 14.3.2):

[math] a_{e1} = a_{e} – \frac{d_{h}}{2} + \frac{d_{f}}{2} = 45.002\ \text{mm} – 13\ \text{mm} + 12\ \text{mm} = 44.002\ \text{mm} [math]

[math] \phi V_{bi} = \phi \min\left( 3.2\, d_{f}\, t_{i}\, f_{ui},\ a_{e1}\, t_{i}\, f_{ui} \right) = (0.9) \times \min\left( 3.2 \times (24)(28)(410),\ (44.002)(28)(410) \right) \times 10^{-3} = 454.63\ \text{kN} [math]

On the column flange the tear-out is to the next hole, with the least pitch from a shear row to the next row [mathin] s_{pv} = 141.28\ \text{mm} [mathin]:

[math] a_{e2} = s_{pv} – d_{h} + \frac{d_{f}}{2} = 141.28\ \text{mm} – 26\ \text{mm} + 12\ \text{mm} = 127.28\ \text{mm} [math]

[math] \phi V_{bc} = \phi \min\left( 3.2\, d_{f}\, t_{fs}\, f_{us},\ a_{e2}\, t_{fs}\, f_{us} \right) = 760.32\ \text{kN} [math]

[math] \phi V_{b} = n_{cw} \min\left( \phi V_{bi},\ \phi V_{bc} \right) = 4 \times (454.63\ \text{kN}) = 1818.5\ \text{kN} [math]

DCR = 51.213 kN / 1818.5 kN = 0.028 ≤ 1.0, OK

Step 8: End plate in bending (AS 4100 Clauses 9.1.8, 9.3.2)

The end plate bends about yield lines around the tension bolts. Its capacity is the plate’s plastic moment per unit length times a yield line factor for the 4E layout. The effective width in the yield lines and the yield line distance are:

[math] b_{i,e} = \min\left( b_{i},\ b_{fb} + 25\ \text{mm} \right) = \min\left( 220\ \text{mm},\ 203\ \text{mm} \right) = 203\ \text{mm}, \qquad a_{h} = 0.5 \sqrt{b_{i,e}\, s_{g}} = 0.5 \sqrt{(203)(130)}\ \text{mm} = 81.225\ \text{mm} [math]

The inner bolt row is taken at not more than the yield line distance from the flange, [mathin] s_{pi} = \min(s_{po},\ a_{h}) = 65\ \text{mm} [mathin]:

[math] Y_{p} = 0.5\, b_{i,e} \left[ d_{11} \left( \frac{1}{s_{pi}} + \frac{1}{a_{h}} \right) + \frac{d_{10}}{s_{po}} – 0.5 \right] + \frac{2}{s_{g}}\, d_{11} \left( s_{pi} + a_{h} \right) [math]

[math] Y_{p} = 2390.3\ \text{mm}, \qquad \phi M_{pt} = \phi\, f_{yi}\, t_{i}^{2}\, Y_{p} = (0.9) \times (250\ \text{MPa}) \times (28\ \text{mm})^{2} \times (2390.3\ \text{mm}) = 421.64\ \text{kNm} [math]

To keep the bolts free of prying, the plate is made at least 1.11 times as strong as the tension bolts, or as the rafter (Clause 9.1.8). The rafter’s design section moment capacity is [mathin] \phi M_{s} = \phi\, f_{yb}\, S_{x} = 305.28\ \text{kNm} [mathin]:

[math] M^{*}_{p} = \min\left( 1.11\, \phi M_{bt},\ 1.11\, \phi M_{s} \right) = \min\left( 1.11 \times 380.59,\ 1.11 \times 305.28 \right)\ \text{kNm} = 338.86\ \text{kNm} [math]

DCR = 338.86 kNm / 421.64 kNm = 0.804 ≤ 1.0, OK

This required capacity does not depend on the applied moment. It makes sure the plate stays thick enough for the bolts to reach their full tension without prying.

Step 9: End plate extension in shear yield

The tension flange force at the end plate is the flange force resolved square to the plate plus the flange share of the shear:

[math] N^{*}_{ft} = N^{*}_{tm} \cos\theta + 0.5\, V^{*} \left| \sin\theta \right| = (402.96\ \text{kN}) \times (0.96593) + 0.5 \times (49\ \text{kN}) \times (0.25882) = 395.57\ \text{kN} [math]

Two bolt rows share it, so the extension of the plate beyond the flange carries half of it as shear:

[math] V^{*}_{p} = \frac{N^{*}_{ft}}{n_{bp}} = \frac{395.57\ \text{kN}}{2} = 197.78\ \text{kN} [math]

[math] \phi V_{pe} = \phi\, 0.5\, f_{yi}\, b_{i}\, t_{i} = (0.9) \times 0.5 \times (250\ \text{MPa}) \times (220\ \text{mm}) \times (28\ \text{mm}) = 693\ \text{kN} [math]

DCR = 197.78 kN / 693 kN = 0.285 ≤ 1.0, OK

Step 10: End plate extension in shear rupture

The net section of the extension through the two bolt holes:

[math] \phi V_{pu} = \phi\, 0.6\, f_{ui} \left( b_{i} – 2\, d_{h} \right) t_{i} = (0.9) \times 0.6 \times (410\ \text{MPa}) \times (220\ \text{mm} – 52\ \text{mm}) \times (28\ \text{mm}) = 1041.5\ \text{kN} [math]

DCR = 197.78 kN / 1041.5 kN = 0.190 ≤ 1.0, OK

Step 11: Column flange in bending at the tension flange (AS 4100 Clause 9.1.8)

The column flange behind the tension bolts bends about its own yield lines. The column continues past the connection and is unstiffened. The yield line distance and the pitch of the bolt rows across the tension flange are:

[math] a_{hc} = 0.5 \sqrt{b_{fs}\, s_{g}} = 0.5 \sqrt{(311)(130)}\ \text{mm} = 100.54\ \text{mm}, \qquad s_{p2} = 2\, s_{po} + t_{fb}’ = 2 \times (65\ \text{mm}) + 11.285\ \text{mm} = 141.28\ \text{mm} [math]

Here [mathin] t_{fb}\’ = 11.285\ \text{mm} [mathin] is the rafter flange thickness measured along the sloping plate.

[math] Y_{c} = 0.5\, b_{fs} \left[ \frac{d_{11}}{a_{hc}} + \frac{d_{10}}{a_{hc}} \right] + \frac{2}{s_{g}} \left[ d_{11} \left( a_{hc} + 0.75\, s_{p2} \right) + d_{10} \left( a_{hc} + 0.25\, s_{p2} \right) + 0.5\, s_{p2}^{2} \right] + 0.5\, s_{g} [math]

[math] Y_{c} = 3535.5\ \text{mm}, \qquad \phi M_{ct} = \phi\, f_{ycf}\, t_{fs}^{2}\, Y_{c} = (0.9) \times (280\ \text{MPa}) \times (25\ \text{mm})^{2} \times (3535.5\ \text{mm}) = 556.85\ \text{kNm} [math]

The column flange has to meet the same 1.11 requirement as the end plate, so that the bolts stay free of prying:

DCR = 338.86 kNm / 556.85 kNm = 0.609 ≤ 1.0, OK

Step 12: Column web yield at the tension flange

The tension flange force spreads through the end plate and the column flange into the column web. The stiff bearing length at the column face is the flange plus the two fillet welds, and the column flange plus root radius sets the dispersion:

[math] b_{sc} = t_{fb} + 2\, t_{wf} = 10.9\ \text{mm} + 2 \times (8\ \text{mm}) = 26.9\ \text{mm}, \qquad k_{c} = t_{fs} + r_{s} = 25\ \text{mm} + 16.5\ \text{mm} = 41.5\ \text{mm} [math]

[math] \phi R_{wt} = \phi \left( b_{sc} + 2\, t_{i} + 6\, k_{c} \right) t_{ws}\, f_{ycw} = (0.9) \times (26.9 + 56 + 249)\ \text{mm} \times (15.7\ \text{mm}) \times (300\ \text{MPa}) = 1406.9\ \text{kN} [math]

The column is taken as continuing above the knee. A column that ends at the knee is not covered by this check.

DCR = 395.57 kN / 1406.9 kN = 0.281 ≤ 1.0, OK

Step 13: Column web bearing yield at the compression flange (AS 4100 Clause 5.13.3)

[math] N^{*}_{fc} = \left( N^{*}_{tm} + 0.5\, N^{*}_{c} \right) \cos\theta + 0.5\, V^{*} \left| \sin\theta \right| = (402.96 + 7.5)\ \text{kN} \times (0.96593) + 0.5 \times (49\ \text{kN}) \times (0.25882) = 402.81\ \text{kN} [math]

The bearing length at the web is dispersed 1:2.5 through the end plate and the column flange:

[math] b_{bf} = b_{sc} + 5\, t_{i} + 5\, t_{fs} = 26.9\ \text{mm} + 5 \times (28\ \text{mm}) + 5 \times (25\ \text{mm}) = 291.9\ \text{mm} [math]

[math] \phi R_{by} = \phi\, 1.25\, b_{bf}\, t_{ws}\, f_{ycw} = (0.9) \times 1.25 \times (291.9\ \text{mm}) \times (15.7\ \text{mm}) \times (300\ \text{MPa}) = 1546.7\ \text{kN} [math]

DCR = 402.81 kN / 1546.7 kN = 0.260 ≤ 1.0, OK

Step 14: Column web crippling at the compression flange

AS 4100 has no web crippling clause. The software uses the crippling capacity of a web under a concentrated load more than half the column depth from the column end, with [mathin] \phi = 0.75 [mathin]:

[math] \phi R_{wc} = \phi\, 0.8\, t_{ws}^{2} \left[ 1 + 3 \frac{b_{sc}}{d_{sup}} \left( \frac{t_{ws}}{t_{fs}} \right)^{1.5} \right] \sqrt{\frac{E\, f_{ycw}\, t_{fs}}{t_{ws}}} = 1623.1\ \text{kN} [math]

DCR = 402.81 kN / 1623.1 kN = 0.248 ≤ 1.0, OK

Step 15: Column web bearing buckling at the compression flange (AS 4100 Clauses 5.13.4, 6.3.3)

The web is taken as a compression member over its clear depth [mathin] d_{1} = d_{sup} – 2\, t_{fs} = 277\ \text{mm} [mathin] (Clause 5.10.1), with the bearing length dispersed 1:1 to the web centreline each side:

[math] b_{b} = b_{bf} + d_{1} = 291.9\ \text{mm} + 277\ \text{mm} = 568.9\ \text{mm}, \qquad A_{w} = b_{b}\, t_{ws} = 8931.7\ \text{mm}^{2} [math]

With [mathin] k_{f} = 1 [mathin] and [mathin] \alpha_{b} = 0.5 [mathin] (Table 6.3.3(A)), the column curve of Clause 6.3.3 gives:

[math] \lambda_{n} = \frac{2.5\, d_{1}}{t_{ws}} \sqrt{k_{f}} \sqrt{\frac{f_{ycw}}{250}} = 48.318, \qquad \alpha_{a} = \frac{2100 (\lambda_{n} – 13.5)}{\lambda_{n}^{2} – 15.3\, \lambda_{n} + 2050} = 20.058 [math]

[math] \lambda = \lambda_{n} + \alpha_{a} \alpha_{b} = 58.347, \qquad \eta = 0.00326 (\lambda – 13.5) = 0.1462, \qquad \xi = \frac{(\lambda/90)^{2} + 1 + \eta}{2 (\lambda/90)^{2}} = 1.8636 [math]

[math] \alpha_{c} = \xi \left[ 1 – \sqrt{1 – \left( \frac{90}{\xi \lambda} \right)^{2}} \right] = 0.81781 [math]

[math] \phi R_{bb} = \phi\, \alpha_{c}\, k_{f}\, A_{w}\, f_{ycw} = (0.9) \times (0.81781) \times (1) \times (8931.7\ \text{mm}^{2}) \times (300\ \text{MPa}) = 1972.2\ \text{kN} [math]

DCR = 402.81 kN / 1972.2 kN = 0.204 ≤ 1.0, OK

Step 16: Column web panel in shear (AS 4100 Clauses 5.11.2, 5.11.4)

The connection is one-sided, so the column web panel takes the larger flange force as shear, with the column shear taken as zero:

[math] V^{*}_{c} = \max\left( N^{*}_{ft},\ N^{*}_{fc} \right) = \max\left( 395.57\ \text{kN},\ 402.81\ \text{kN} \right) = 402.81\ \text{kN} [math]

[math] \frac{d_{1}}{t_{ws}} \sqrt{\frac{f_{ycw}}{250}} = 19.327 \le 82, \qquad A_{w} = d_{sup}\, t_{ws} = 5133.9\ \text{mm}^{2} [math]

The web is not slender, so it reaches shear yield ([mathin] \alpha_{v} = 1 [mathin]):

[math] \phi V_{c} = \phi\, 0.6\, \alpha_{v}\, f_{ycw}\, A_{w} = (0.9) \times 0.6 \times (1) \times (300\ \text{MPa}) \times (5133.9\ \text{mm}^{2}) = 831.69\ \text{kN} [math]

DCR = 402.81 kN / 831.69 kN = 0.484 ≤ 1.0, OK

Summary of checks

Design checkDesign action effectDesign capacityDCRResult
Connection detailing limitations42 mm45 mm0.933PASS
Beam flange welds416.8 kN433.21 kN0.962PASS
Beam web welds in tension406.07 kN493.67 kN0.823PASS
Beam web welds in shear47.33 kN493.67 kN0.096PASS
Bolts at the tension flange160.49 kNm380.59 kNm0.422PASS
Bolt group in shear51.213 kN533.54 kN0.096PASS
Bolt group in bearing on end plate and column flange51.213 kN1818.5 kN0.028PASS
End plate in bending338.86 kNm421.64 kNm0.804PASS
End plate extension, shear yield197.78 kN693 kN0.285PASS
End plate extension, shear rupture197.78 kN1041.5 kN0.190PASS
Column flange in bending at the tension flange338.86 kNm556.85 kNm0.609PASS
Column web yield at the tension flange395.57 kN1406.9 kN0.281PASS
Column web bearing yield at the compression flange402.81 kN1546.7 kN0.260PASS
Column web crippling at the compression flange402.81 kN1623.1 kN0.248PASS
Column web bearing buckling at the compression flange402.81 kN1972.2 kN0.204PASS
Column web panel in shear402.81 kN831.69 kN0.484PASS

The connection passes every check. The rafter flange welds govern at 0.962, followed by the end plate in bending at 0.804 and the web welds in tension at 0.823. The last two are set by the capacities of the rafter and the bolts, not by the applied loads. The column passes all its local checks without stiffeners, with the web panel in shear highest at 0.484.

Compared with the same rafter, plate and bolts on a straight beam, the 15° slope raises the flange weld force by the share of the shear across the plate, and gives the bolts longer lever arms along the deeper plate.

What to change if a check fails

  • Detailing limits: adjust the gauge, the bolt rows’ distance from the flanges or the plate edge distances to the limits in Step 1.
  • Flange welds: increase the fillet size. The weld length is fixed by the rafter flange.
  • Web welds: increase the web fillet size. The web weld in tension is designed for the web’s own yield capacity.
  • Tension bolts: use a larger bolt, or a stiffened or eight-bolt layout where the module offers one.
  • End plate in bending or extension shear: use a thicker end plate, or a higher grade.
  • Column flange in bending: use a heavier column, with a thicker flange.
  • Column web checks: use a heavier column.

Frequently asked questions

Why are the flange welds 8 mm on one side and 10 mm on the other?

At a 15° slope the two fillets on each flange are not at 90° to the plate. On the acute side the included angle is 75°, and on the obtuse side it is 105°. Each is an equal leg fillet sized to give the same design throat thickness as a straight 8 mm fillet (Clause 9.6.3.4): 7.1303 mm on the acute side and 9.2924 mm on the obtuse side, rounded up to 8 mm and 10 mm.

How does the slope change the design forces?

The shear and the axial compression act along the rafter, not along the plate. Resolved square to and along the plate, the shear adds 0.5 V* sin θ to each flange force, and the shear on the bolts becomes V* cos θ + N*c sin θ. In this example that raises the flange weld force from 410.46 kN to 416.8 kN.

Why is the end plate deeper than for a straight beam?

The rafter’s depth measured along the plate is its depth divided by cos θ, so the plate grows with the slope. Here it is 637.22 mm, against 624.54 mm for the same section framing in square. The bolt lever arms grow with it, which raises the capacity of the tension bolts.

Does this check cover a column that stops at the knee?

No. The column web checks take the column as continuing above the knee, so the force spreads both ways from the flange. A column that ends at the knee is not covered.

Is there a column web crippling clause in AS 4100?

No. The software uses the crippling capacity of a web under a concentrated load more than half the column depth from the column end, with a capacity factor of 0.75. It is well clear of governing in this example.

Design a knee end plate connection for free

Every number on this page comes from one solve. Pick AS 4100:2020 and the knee end plate connection, enter your rafter, column, plate, bolts and loads, and see each of these checks in your browser. There is nothing to install.

The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every design capacity and DCR, for AS 4100:2020 shear connections, moment connections and splices. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.

References

Harold Munalem, Product Manager for SkyCiv Connection Design

Harold Munalem
Product Manager, Connection Design
10+ years in steel connection design
LinkedIn

How can we help?

×

Updated November 24, 2026

Still stuck? Contact us

Go to Top