SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

Flexible End Plate Connection Design to AS 4100

To design a flexible end plate connection to AS 4100, you follow the beam end shear from the beam web, through the fillet welds and the end plate, into the bolts and the support. That means checking the welds to the beam web, the bolts in shear and in bearing, the end plate in shear and block shear, and the beam web along the weld. The detailing limits on pitch, gauge, edge distance and plate depth come first, because the end plate only behaves as a simple connection if it is thin and has a wide enough gauge to flex.

This page works through one example from start to finish: a 460 UB 82.1 beam framing into the flange of a 310 UC 158 column, with a design shear of 150 kN, eight M20 8.8/S bolts and a 10 mm AS/NZS 3678 Gr.250 end plate, designed to AS 4100:2020. Every equation is written out with its numbers, in the same order as the calculation report that the SkyCiv Connection Design module produces for it. It uses the same beam, column and design shear as the web side plate example, so you can compare the two connections check by check. The scope and conventions of the AS 4100 module are on the design of steel connections using AS 4100:2020 page.

What is a flexible end plate connection?

A flexible end plate connection is a thin plate fillet welded across the end of the beam web in the shop and bolted to the supporting member on site. The plate is shallower than the beam and is welded to the web only, not to the flanges, so the beam end can rotate as the plate bends between its two bolt lines. That is what makes it a simple connection: it carries the beam end shear and almost no end moment.

It is a popular shear connection in Australian building frames because the beam arrives on site already fitted with its plate, and the site work is bolting to a flat face. The beam has to be cut to an accurate length, as there is no slack between the plate and the support. In the AS 4100 module it sits beside the web side plate, which is welded to the support and bolted to the beam, and the single and double angle cleats, which are bolted on both sides.

In this example the end plate has two vertical lines of four bolts at a 140 mm gauge, bolted to the flange of the column.

Flexible end plate elevation: 460 UB 82.1 beam with a 10 mm end plate bolted with M20 8.8/S bolts to a 310 UC 158 flange

Elevation of the example connection. The end plate is welded to the beam web with a 6 mm E49XX fillet weld on both sides.

Section A-A: PL 10x240x325 AS/NZS 3678 Gr.250 end plate with eight M20 8.8/S bolts at 75 mm pitch and 140 mm gauge

Section A-A, looking at the end plate. Four rows at 75 mm pitch, two columns at a 140 mm gauge, and 50 mm edge distances all round.

SkyCiv Connection Design Assembly tab: flexible end plate 240 x 325 x 10 mm, AS/NZS 3678 Gr.250, shown in the 3D view

The same connection in SkyCiv Connection Design, with the end plate selected on the Assembly tab.

Flexible end plate connection design: the steps at a glance

  1. Check the connection detailing limits: pitch, gauge, edge distances and end plate depth.
  2. Check the minimum fillet weld size, then the design capacity of the weld to the beam web.
  3. Check the design capacity of the bolt group in shear.
  4. Check the bolt group in bearing on the end plate and on the column flange.
  5. Check the end plate in shear.
  6. Check the end plate in block shear.
  7. Check the beam web in shear along the weld.
  8. Check the supported member (beam) in shear.

Design inputs for this example

The design code is AS 4100:2020, with section properties from the Australian section database. The yield strength of each part follows its grade and thickness: 300 MPa for the beam, 280 MPa for the column with its 25 mm flange, and 260 MPa for the 10 mm AS/NZS 3678 Gr.250 end plate.

ItemSymbolValue
Design shear (design action effect)[mathin] V^{*} [mathin]150 kN
Beam460 UB 82.1, AS/NZS 3679.1 Gr.300
Beam depth[mathin] d_{bm} [mathin]460 mm
Beam web thickness[mathin] t_{wb} [mathin]9.9 mm
Beam flange width / thickness[mathin] b_{fb},\ t_{fb} [mathin]191 mm / 16 mm
Beam yield / tensile strength[mathin] f_{yb},\ f_{ub} [mathin]300 MPa / 440 MPa
Column310 UC 158, AS/NZS 3679.1 Gr.300
Column depth / web thickness[mathin] d_{sup},\ t_{ws} [mathin]327 mm / 15.7 mm
Column flange width / thickness[mathin] b_{fs},\ t_{fs} [mathin]311 mm / 25 mm
Column yield / tensile strength[mathin] f_{ys},\ f_{us} [mathin]280 MPa / 440 MPa
Elastic modulus[mathin] E [mathin]200000 MPa
ItemSymbolValue
End platePL 10 x 240 x 325, AS/NZS 3678 Gr.250
Plate width / depth / thickness[mathin] b_{i},\ d_{i},\ t_{i} [mathin]240 mm / 325 mm / 10 mm
Plate yield / tensile strength[mathin] f_{yp},\ f_{up} [mathin]260 MPa / 410 MPa
BoltsM20 8.8/S, threads included in the shear plane
Bolt diameter / minimum tensile strength[mathin] d_{fw},\ f_{uf} [mathin]20 mm / 830 MPa
Holes in end plate and column flange[mathin] d_{h} [mathin]Nominal, 22 mm
Weld to beam web6 mm fillet both sides, E49XX, SP
Weld size / weld metal strength[mathin] t_{ww},\ f_{uw} [mathin]6 mm / 490 MPa
GeometrySymbolValue
Bolt rows / row pitch[mathin] n_{p},\ s_{p} [mathin]4 / 75 mm
Bolt columns / column pitch (gauge)[mathin] n_{g},\ s_{g} [mathin]2 / 140 mm
Vertical edge distance on end plate[mathin] l_{ev\_ep} [mathin]50 mm
Horizontal edge distance on end plate[mathin] l_{eh\_ep} [mathin]50 mm

Unlike a web side plate, the end plate has no bolt group eccentricity in this design. The bolts are in the face of the support, so the module takes the design shear at the centroid of the bolt group.

Design shear (AS 4100 Clause 9.1.4)

AS 4100 Clause 9.1.4 sets a minimum design action for a simple connection. The design shear is not taken less than the lesser of 0.15 times the design shear capacity of the beam and 40 kN. The beam capacity is the uncoped web shear capacity, which Step 8 uses again:

[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (460\ \text{mm}) \times (9.9\ \text{mm}) = 737.75\ \text{kN} [math]

[math] V^{*}_{min} = \min\left( 0.15\, \phi V_{vo},\ 40\ \text{kN} \right) = \min\left( 0.15 \times (737.75\ \text{kN}),\ 40\ \text{kN} \right) = 40\ \text{kN} [math]

[math] V^{*} = \max\left( V^{*},\ V^{*}_{min} \right) = \max\left( 150\ \text{kN},\ 40\ \text{kN} \right) = 150\ \text{kN} [math]

The 150 kN entered is above the minimum, so it is the design action effect for every check below.

Step 1: Connection detailing limitations (AS 4100 Clause 9.5)

The bolt layout has to be buildable and has to match the assumptions behind the capacity equations. For an end plate the gauge matters twice: it must be wide enough to clear the beam web and its welds and to let the plate flex, and not so wide that the plate stops behaving as a tied pair of bolt lines.

The minimum pitch is [mathin] 2.5\, d_{f} = 2.5 \times 20\ \text{mm} = 50\ \text{mm} [mathin] (Clause 9.5.1). The minimum edge distance for an M20 bolt is 35 mm, [mathin] 1.75\, d_{f} [mathin] from Table 9.5.2. The maximum edge distance is 12 times the plate thickness, [mathin] 12 \times 10\ \text{mm} = 120\ \text{mm} [mathin], and the maximum column pitch is 15 times the plate thickness, [mathin] 15 \times 10\ \text{mm} = 150\ \text{mm} [mathin]. The other limits in the table, including the 61.9 mm minimum column pitch, the 88.7 mm minimum gauge on the column flange and the 230 mm minimum and 405.2 mm maximum end plate depths, are the limits the module applies for this beam and support. The edge distance on the column flange is what is left of the 311 mm flange outside the 140 mm gauge, [mathin] (311 – 140) / 2 = 85.5\ \text{mm} [mathin].

Detailing limitLimit (mm)Actual (mm)DCRResult
Minimum bolt row pitch50.00075.0000.667PASS
Maximum bolt row pitch140.00075.0000.536PASS
Minimum bolt column pitch61.900140.0000.442PASS
Maximum bolt column pitch150.000140.0000.933PASS
Minimum vertical edge distance on end plate35.00050.0000.700PASS
Minimum horizontal edge distance on end plate35.00050.0000.700PASS
Minimum horizontal edge distance on column flange35.00085.5000.409PASS
Minimum bolt gauge on column flange88.700140.0000.634PASS
Minimum end plate depth230.000325.0000.708PASS
Maximum end plate depth405.200325.0000.802PASS
Maximum edge distance120.00050.0000.417PASS

For a minimum limit the ratio is limit over actual, and for a maximum it is actual over limit. The governing row is the bolt column pitch, the 140 mm gauge against the 150 mm maximum:

[math] DCR = \frac{140\ \text{mm}}{150\ \text{mm}} = 0.93333 [math]

DCR = 0.933 ≤ 1.0, OK

A wide gauge is what you want on a flexible end plate, so a ratio close to this limit is not a problem. It is the opposite end of the range that would make the plate stiff.

Step 2: Weld to the supported member (AS 4100 Clauses 9.6.3.10, 9.7.1)

The end plate is welded to the beam web with a fillet weld on each side, running the full depth of the plate. These two welds carry the whole design shear out of the beam web. The report checks the minimum weld size first, then the weld capacity.

Minimum fillet weld size (Table 9.6.3.2)

A fillet weld that is too small for the parts it joins cools too fast and can crack, so AS 4100 Table 9.6.3.2 sets a minimum size for the thicker part, not exceeding the thinner part. Here the thicker part is the 10 mm end plate, which gives a minimum of 4 mm:

[math] t_{ww} = 6\ \text{mm} \ge t_{w,min} = 4\ \text{mm} [math]

DCR = 4 mm / 6 mm = 0.667 ≤ 1.0, OK

The summary of the report lists this as its own row. It compares weld sizes, not a design action with a capacity.

Weld capacity

The weld is Structural Purpose (SP), so the capacity factor is 0.8 from Table 3.4. The design capacity per unit length of an equal-leg fillet weld, with a throat of the leg size over the square root of 2, and [mathin] k_{r,weld} = 1 [mathin] because it is not a long welded lap joint:

[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{ww}\, k_{r,weld} [math]

[math] \phi v_{w} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (6\ \text{mm}) \times (1) = 0.99787\ \text{kN/mm} [math]

The weld runs the full end plate depth, [mathin] d_{i} = 325\ \text{mm} [mathin], on both sides of the web:

[math] \phi V_{w} = 2\, d_{i}\, \phi v_{w} = 2 \times (325\ \text{mm}) \times (0.99787\ \text{kN/mm}) = 648.61\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{w} = 648.61\ \text{kN} [math]

DCR = 150 kN / 648.61 kN = 0.231 ≤ 1.0, OK

Step 3: Design capacity of the bolt group in shear (AS 4100 Clauses 9.2.2.1, 9.3.1)

The threads are in the single shear plane, so the core area is used: [mathin] n_{n} = 1,\ A_{c} = 225\ \text{mm}^{2} [mathin] and [mathin] n_{x} = 0 [mathin]. The capacity factor for a bolt in shear is 0.8, and the reduction factors [mathin] k_{rd} [mathin] and [mathin] k_{r,bolt} [mathin] are both 1:

[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, k_{rd}\, k_{r,bolt}\, \left( n_{n} A_{c} + n_{x} A_{o} \right) [math]

[math] \phi V_{f} = (0.8) \times 0.62 \times (830\ \text{MPa}) \times (1) \times (1) \times \left( (1)(225\ \text{mm}^{2}) + (0)(314.16\ \text{mm}^{2}) \right) = 92.628\ \text{kN} [math]

For an end plate the module takes the load at the centroid of the bolt group, so every bolt carries an equal share and the group capacity is the bolt capacity times the number of bolts, [mathin] n_{b} = 8 [mathin]:

[math] \phi V_{df} = n_{b}\, \phi V_{f} = (8) \times (92.628\ \text{kN}) = 741.02\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{df} = 741.02\ \text{kN} [math]

DCR = 150 kN / 741.02 kN = 0.202 ≤ 1.0, OK

Compare this with the web side plate example, where the same eight bolts give 430.69 kN because the group is loaded at a 107.5 mm eccentricity.

Step 4: Bolt group in bearing on the end plate and the support (AS 4100 Clause 9.2.2.4)

Each bolt bears on its hole in the end plate and in the column flange. A ply can fail by crushing at the hole, capped at [mathin] 3.2\, d_{fw}\, t_{p}\, f_{up} [mathin], or by tearing out in the direction of the force, which depends on [mathin] a_{e} [mathin]. The force is vertical, so the vertical distances govern.

Bearing on the end plate

[mathin] a_{e} [mathin] is the distance from the edge of the hole to the edge of the ply, or to the next hole, plus half the bolt diameter. With [mathin] d_{h} = 22\ \text{mm} [mathin]:

[math] a_{e1} = l_{ev\_ep} – 0.5\, d_{h} + 0.5\, d_{fw} = (50\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 49\ \text{mm} [math]

[math] a_{e2} = s_{p} – d_{h} + 0.5\, d_{fw} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

[math] a_{e} = \min\left( a_{e1},\ a_{e2} \right) = \min\left( 49\ \text{mm},\ 63\ \text{mm} \right) = 49\ \text{mm} [math]

The capacity factor for a ply in bearing is 0.9:

[math] \phi V_{b} = \phi \min\left( 3.2\, d_{fw}\, t_{i}\, f_{up},\ a_{e}\, t_{i}\, f_{up} \right) [math]

[math] \phi V_{b,pl} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (10\ \text{mm}) \times (410\ \text{MPa}),\ (49\ \text{mm}) \times (10\ \text{mm}) \times (410\ \text{MPa}) \right) = 180.81\ \text{kN} [math]

Bearing on the column flange

The column runs past the connection, so there is no edge near the bolts in the direction of the force. Only the distance to the next hole applies:

[math] a_{e3} = s_{p} – d_{h} + 0.5\, d_{fw} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

[math] \phi V_{b,sup} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (25\ \text{mm}) \times (440\ \text{MPa}),\ (63\ \text{mm}) \times (25\ \text{mm}) \times (440\ \text{MPa}) \right) = 623.7\ \text{kN} [math]

Bolt group bearing capacity

The weaker ply per bolt, times the number of bolts:

[math] \phi V_{b} = \min\left( \phi V_{b,pl},\ \phi V_{b,sup} \right) n_{b} = \min\left( 180.81\ \text{kN},\ 623.7\ \text{kN} \right) \times (8) = 1446.5\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{b} = 1446.5\ \text{kN} [math]

DCR = 150 kN / 1446.5 kN = 0.104 ≤ 1.0, OK

The 10 mm end plate governs over the 25 mm column flange, and its edge distance term is the smaller one, so the 50 mm vertical edge distance sets the end plate’s bearing capacity.

Step 5: End plate in shear (AS 4100 Clause 5.11.3)

The design shear passes down the end plate on both sides of the beam web, so the module takes two shear planes, each the full depth and thickness of the plate. A rectangular plate does not carry shear uniformly, and Clause 5.11.3 allows for that with 0.5 fy on the gross area:

[math] \phi V_{v} = 2\, \phi\, 0.5\, f_{yp}\, d_{i}\, t_{i} [math]

[math] \phi V_{v} = 2 \times (0.9) \times 0.5 \times (260\ \text{MPa}) \times (325\ \text{mm}) \times (10\ \text{mm}) = 760.5\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{v} = 760.5\ \text{kN} [math]

DCR = 150 kN / 760.5 kN = 0.197 ≤ 1.0, OK

Step 6: End plate in block shear (AS 4100 Clause 9.1.9)

A block of the end plate can tear out around each bolt column: shear down the column of bolts to the bottom edge of the plate, plus tension across to the side edge. There are two such blocks, one on each side of the beam web, so the areas are doubled.

Net area in tension, across the two bottom bolts to the side edges:

[math] A_{nt} = \left( 2\, l_{eh\_ep} – d_{h} \right) t_{i} [math]

[math] A_{nt} = \left( 2 \times (50\ \text{mm}) – (22\ \text{mm}) \right) \times (10\ \text{mm}) = 780\ \text{mm}^{2} [math]

Gross and net areas in shear, along both bolt columns:

[math] A_{gv} = 2 \left[ l_{ev\_ep} + (n_{p} – 1)\, s_{p} \right] t_{i} = 2 \times \left[ (50\ \text{mm}) + (4 – 1)(75\ \text{mm}) \right] \times (10\ \text{mm}) = 5500\ \text{mm}^{2} [math]

[math] A_{nv} = 2 \left[ l_{ev\_ep} + (n_{p} – 1)\, s_{p} – (n_{p} – 0.5)\, d_{h} \right] t_{i} = 2 \times \left[ (50\ \text{mm}) + (3)(75\ \text{mm}) – (3.5)(22\ \text{mm}) \right] \times (10\ \text{mm}) = 3960\ \text{mm}^{2} [math]

The tension stress is uniform, so [mathin] k_{bs} = 1 [mathin], and the capacity factor for block shear is 0.75:

[math] \phi R_{bs} = \phi \min\left( 0.6\, f_{up}\, A_{nv} + k_{bs}\, f_{up}\, A_{nt},\ 0.6\, f_{yp}\, A_{gv} + k_{bs}\, f_{up}\, A_{nt} \right) [math]

[math] \phi R_{bs} = (0.75) \times \min\left( 0.6 \times (410)(3960) + (1)(410)(780),\ 0.6 \times (260)(5500) + (1)(410)(780) \right) \times 10^{-3} = 883.35\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi R_{bs} = 883.35\ \text{kN} [math]

DCR = 150 kN / 883.35 kN = 0.170 ≤ 1.0, OK

The second term, shear yielding on the gross area plus tension rupture, is the smaller one here.

Step 7: Beam web in shear (AS 4100 Clause 5.11.2)

All of the design shear leaves the beam through the welds to the end plate, so the length of beam web that carries it is the end plate depth, not the full beam depth. The design shear capacity of that strip of web:

[math] \phi V_{w} = \phi\, 0.6\, f_{yb}\, d_{i}\, t_{wb} [math]

[math] \phi V_{w} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (325\ \text{mm}) \times (9.9\ \text{mm}) = 521.24\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{w} = 521.24\ \text{kN} [math]

DCR = 150 kN / 521.24 kN = 0.288 ≤ 1.0, OK

This is the governing strength check. A deeper end plate lengthens the welds and raises this capacity directly.

Step 8: Supported member in shear (AS 4100 Clause 5.11.2)

Away from the end plate the whole beam web carries the shear. The beam is uncoped, so the full depth is available. First, the web has to be stocky enough to reach shear yield without buckling:

[math] \frac{d_{p}}{t_{w}} = 43.232 \le \frac{82}{\sqrt{f_{y} / 250}} = 74.855 [math]

The web is not slender, so the design shear capacity is the yield capacity of the web:

[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (460\ \text{mm}) \times (9.9\ \text{mm}) = 737.75\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{vo} = 737.75\ \text{kN} [math]

DCR = 150 kN / 737.75 kN = 0.203 ≤ 1.0, OK

Summary of checks

Design checkDesign action effectDesign capacityDCRResult
Connection detailing limitations140 mm150 mm0.933PASS
Minimum weld size4 mm6 mm0.667PASS
Weld to supported member150 kN648.615 kN0.231PASS
Bolt group in shear150 kN741.024 kN0.202PASS
Bolt group in bearing on end plate and support150 kN1446.48 kN0.104PASS
End plate in shear150 kN760.5 kN0.197PASS
End plate in block shear150 kN883.35 kN0.170PASS
Beam web in shear150 kN521.235 kN0.288PASS
Supported member in shear150 kN737.748 kN0.203PASS

The connection passes every check. The highest ratio, 0.933, does not compare a design action with a capacity: it is the 140 mm gauge against the 150 mm maximum column pitch for a 10 mm plate. The minimum weld size row, a 4 mm minimum against the 6 mm weld, is 0.667. Of the strength checks, the beam web in shear along the end plate governs at 0.288, followed by the weld at 0.231. The end plate in shear follows at 0.197. The bolts have a large margin at this load, because the bolt group is loaded at its centroid.

Auto Design is available for the flexible end plate in the AS 4100 module. It changes the bolts, end plate and welds until every check passes, and keeps your members and design actions as entered. See the Auto Design page for the AS 4100 preferences it works to.

What to change if a check fails

  • Detailing limits: adjust the pitch, gauge, edge distances or end plate depth to the limits in Step 1. If the gauge is too narrow for the column flange, widen it, and if it is over the maximum column pitch, use a thicker plate or a narrower gauge.
  • Minimum weld size: increase the fillet weld to the Table 9.6.3.2 minimum for the thicker part.
  • Weld capacity: increase the weld size, use a stronger electrode, or make the end plate deeper to lengthen the welds.
  • Bolt group in shear: add a bolt row, use a larger bolt, or a higher bolt grade.
  • Bolt bearing: increase the vertical edge distance or the pitch, or use a thicker end plate. If the support governs, add bolts.
  • End plate in shear or block shear: make the end plate deeper, or use a higher grade. A thicker plate also works but makes the connection stiffer, so prefer a deeper plate.
  • Beam web in shear: make the end plate deeper, which lengthens the web strip that carries the shear. If the plate is already at its maximum depth, use a heavier beam.

Frequently asked questions

Why is the bolt group not designed for an eccentricity?

The bolts are in the face of the support, in line with the reaction, so the module takes the design shear at the centroid of the bolt group and gives each of the eight bolts an equal share.

Why is the beam web checked over the end plate depth and not the full beam depth?

The shear gets out of the beam through the welds, and the welds only run the depth of the end plate. The web above and below the plate carries no shear into the connection, so Step 7 uses 325 mm. Step 8 then checks the full beam section away from the connection.

Why does the end plate shear check have a factor of 2?

The end plate is welded to the beam web on its centreline, so the shear passes down two strips of plate, one on each side of the web, each the full depth and thickness of the plate. The module takes the 0.5 fy capacity of Clause 5.11.3 for each strip.

What makes an end plate flexible?

A thin plate, a wide gauge and a plate that is shallower than the beam and welded to the web only. Those let the plate bend between the bolt lines as the beam end rotates, so the connection carries little moment. A thick plate with a tight gauge, or one welded to the flanges, becomes a moment connection.

Why was the 150 kN design shear not increased to the Clause 9.1.4 minimum?

Clause 9.1.4 asks for a simple connection to be designed for at least the lesser of 0.15 times the beam’s design shear capacity and 40 kN. For this 460 UB 82.1 that is 40 kN, and the 150 kN entered is larger, so it is used as is.

Is the column checked in this design?

The column flange is checked as a ply in bearing in Step 4, and its width sets the edge distance and gauge limits in Step 1. For a column flange support the module does not run a separate shear check of the column.

Design a flexible end plate connection for free

Every number on this page comes from one solve. Pick AS 4100:2020 and the flexible end plate, enter your beam, support, bolts and design shear, and see each of these checks in your browser. There is nothing to install.

The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every design capacity and DCR, for AS 4100:2020 shear connections, moment connections and splices. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.