SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

Loads and Load Combinations

You enter the design loads on the Loads tab. On most connection types you can enter them in one of two ways: as a single Envelope row, or as a list of Load Combinations, each with its own signs. This page explains both, the sign convention, the utility ratio limit, and how the results and report show which load combination governs.

The loads are labelled Fx, Fy, Fz, Mx, My and Mz for every design code, and they are always called load combinations, for AISC 360-16, AISC 360-22 and AS 4100:2020 alike.

The loads table

The table only shows the loads the connection type takes:

  • Shear connections: Fy, the shear at the beam end.
  • Shear plus axial connections: Fx, the axial force in the beam, and Fy, the shear.
  • Moment connections: Fx, Fy and Mz, the moment at the beam end.
  • Splices and bracing connections show the forces and moments that type carries, such as the brace axial forces on a brace connection.

Hover over the ⓘ icon in a column heading to see what that load means on the connection you have open.

Enter LRFD (factored) loads for an AISC LRFD design and ASD (service) loads for an AISC ASD design. For AS 4100, enter the strength limit state design actions.

Envelope or load combinations

Above the loads table, choose Envelope or Load Combinations. A connection uses one or the other, never both.

Loads tab with the Envelope and Load Combinations switch above the loads table of a moment connection

Load combinations are available on:

  • shear plus axial connections
  • moment connections
  • beam splices and column splices
  • vertical brace, chevron brace, horizontal brace and knee brace connections

Pure shear connections only take an envelope, as a shear connection has only one load to enter.

Switching between the two modes asks you to confirm first ("Switch to Load Combinations?" or "Switch to Envelope Loads?"), because the loads you entered in one mode are not kept in the other. When you switch from an envelope to load combinations, the envelope is turned into starting combinations (LC1, LC2) that you can then edit. On a brace connection with opposed braces, these give the two braces opposite signs.

Switch to Load Combinations? dialog with the Switch and Cancel buttons

Envelope

An envelope takes the largest value of each load across all your load combinations and applies them together. It is quick and conservative.

An axial load can have both a compression and a tension value. Enter the two separated by a comma, for example 55, -85. Compression is positive and tension is negative. If you enter one value, such as 55, it is used for both.

Envelope row with the axial load Fx entered as 55, -85, headed (C+ / T-)

The envelope is checked for the loads exactly as you enter them. The connection is checked once with the compression values and once with the tension values, and nothing in between. Where an axial load has a single value, that value is used for both cases.

On a moment connection, leaving the axial load blank or 0 means no axial force (0, 0).

In an envelope, the shear Fy always acts in the gravity direction, downward on the beam end, and the moment Mz is taken as a magnitude.

Load combinations

In Load Combinations mode, each row is one load combination, with every load in it acting at the same time and each one carrying its own sign. Hover over the Load Combinations button to see which combinations to enter:

  • AISC LRFD: "Enter each LRFD load combination from ASCE 7 Section 2.3 as its own row, using the factored loads that act at the same time."
  • AISC ASD: "Enter each ASD load combination from ASCE 7 Section 2.4 as its own row, using the loads that act at the same time."
  • AS 4100: "Enter each load combination from AS/NZS 1170.0 as its own row, using the strength limit state design actions that act at the same time."

Each load in a combination is a single value. To build the table:

  • Add load combination adds a row. The count of rows is shown beside the buttons.
  • Paste from spreadsheet pastes rows copied from Excel or another spreadsheet. Copy the header row with the load names as well, so the columns are matched by name. If you already have combinations, choose Replace or Append.
  • The rows are named LC1, LC2 and so on, in order, and keep those names in the results and the report.

Load combinations table with four rows LC1 to LC4, Add load combination and Paste from spreadsheet

Paste Load Combinations dialog with a header row Fx, Fy, Mz and four rows, with Replace and Append

Click a row to show that combination’s loads in the 3D view.

The connection is checked for every combination, and each check reports the combination that governs it.

Sign convention

The sign convention is shown in the table headers and in the tooltips:

  • Axial forces (Fx): positive for compression, negative for tension. The axial columns are headed (C+ / T−).
  • Shear (Fy): positive acts downward on the beam end, negative acts upward.
  • Moment (Mz): positive is sagging, with the bottom flange in tension and the top flange in compression. In load combinations, the Mz column is headed (sagging +).
  • Other loads: enter a positive or negative value. The arrow in the 3D view shows the direction of the load.

This is the same convention SkyCiv Structural 3D uses, so loads from an S3D model come across with their signs.

Utility ratio limit

The Utility ratio limit field sits under the loads table, in both modes. It is the highest utility ratio a check can reach and still pass, from 0.50 to 1.00. The default is 1.00. Use a lower value, for example 0.90, to keep some reserve in the design.

The limit applies to the strength checks only. Ductility and detailing checks are always held to 1.00, as the design code requires. The ratios in the results and the report are the real ratios. Only the pass or fail is judged against your limit. When the limit is below 1.00, the results show it as, for example, "Utility ratio limit 0.90 (strength checks only)", and the report states it too.

Utility ratio limit field set to 1.00 and the Full Report option Include every load combination

The app remembers the last limit you used in your browser and starts new connections with it. A file saved with its own limit keeps that limit when you open it.

Results and reports

With load combinations, each combination is checked separately. For each check, the governing combination is the one with the highest ratio. A combination that fails a check always governs it.

On the Results tab:

  • Each check shows a pill with the name of its governing load combination.
  • Show results for lets you look at the checks for one combination at a time. Governing load combination per check is the default. In the list, the combination with the highest ratio overall is marked "(governing)".
  • On paid plans, after the design checks run, the Loads table shows each combination’s highest ratio beside its name, until you edit the loads.

Results tab with the Show results for list and the governing load combination pill on each check

Load combinations table after a run, with the highest ratio of each combination beside its name

The calculation report gives each check from its governing combination. Under Full Report on the Loads tab, tick Include every load combination to add every combination to the report. Left unticked, the report includes only the combinations that govern at least one check.

Load combinations and Auto Design

Auto Design works in both modes. With load combinations, every design it tries is checked against each combination with its own signs, and it only accepts a design that passes all of them. It also designs to your utility ratio limit. It never changes your loads or your limit.

Try it now

Pick a moment or shear plus axial connection, switch the Loads tab to Load Combinations, and enter a few rows with their signs.

Sign-up to Free Account

A free account lets you save and reload your connection files, which the free tool does not. It also gives you access to the rest of SkyCiv’s structural software, including Structural 3D.

Connection Design Standalone

Want to use the connection design module only? Click the button below for the standalone pricing.

How can we help?

×

Updated November 24, 2026

Still stuck? Contact us

Go to Top