SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

AISC 360-22 vs 360-16: What Changes in Connection Design

SkyCiv Connection Design runs every AISC connection to either AISC 360-16 or AISC 360-22. For most connections the switch changes the clause numbers in the calculation report and nothing else: the bolt, weld, block shear, plate and beam checks give the same capacities to the last digit. A few checks do change their numbers, and they all involve rectangular HSS.

This page lists what the program does differently under each edition, and shows it on two published design examples run both ways, with only the design code changed.

Flange plate moment connection to an HSS8x4x1/2 column: W18x50 beam, 3/4 in flange plates, Mu = 38 kip-ft

How do you choose the edition?

The edition follows the Design Code you pick: AISC 360-16 LRFD, AISC 360-16 ASD, AISC 360-22 LRFD or AISC 360-22 ASD. Opening a saved connection or a sample keeps the code you have selected, so you can run the same input under both editions and compare the reports.

Checks whose numbers change

ConnectionAISC 360-16AISC 360-22
Flange plate to a rectangular HSS column: local yielding of the plate[mathin]\phi = 0.95[mathin], [mathin]\Omega = 1.58[mathin] (the report cites AISC Design Guide 24, Table 7-2)Section K2.3 sends the force to Section J4.1, tensile yielding over the effective width [mathin]B_{e}[mathin] of Eq. K1-1: [mathin]\phi = 0.90[mathin], [mathin]\Omega = 1.67[mathin]
Flange plate to a rectangular HSS column: punching of the HSS faceNot checkedShear yielding (punching) of the HSS face, Section J4.2 over [mathin]B_{ep}[mathin] of Eq. K1-2, [mathin]\phi = 1.00[mathin], [mathin]\Omega = 1.50[mathin]. Added only when the plate sits on the flat of the face, [mathin]B_{p} \le B – 2t[mathin]
Rectangular HSS brace slotted onto a single concentric gusset: shear lag[mathin]\bar{x} = \frac{B^{2} + 2BH}{4(B + H)}[mathin], and a detailing limit of weld length [mathin]l \ge H[mathin]Table D3.1 Case 5, [mathin]\bar{x}[mathin] including the design wall thickness [mathin]t[mathin] (below); no [mathin]l \ge H[mathin] limit

In the HSS brace row, [mathin]H[mathin] is the side of the brace along the gusset, [mathin]B[mathin] the side across it, and [mathin]U = 1 – \bar{x}/l[mathin] in both editions. The 360-22 eccentricity is:

[math]\bar{x} = \frac{B}{2} – \frac{2\left(\frac{B}{2}\right)^{2} + tH – 2t^{2}}{2H + 4\frac{B}{2} – 4t}[math]

Checks that only change their clause numbers

AISC 360-22 added a new Section J3.1, so every later section of J3 moved up by one. The tables (J3.1 to J3.5) and the equation numbers (J3-1 to J3-6f) kept their numbers. The report is relabelled to match:

SubjectAISC 360-16AISC 360-22
Size and use of holesJ3.2J3.3
Minimum spacingJ3.3J3.4
Minimum edge distance (Table J3.4)J3.4J3.5
Maximum spacing and edge distanceJ3.5J3.6
Bolt tension and shear strength, Eq. J3-1J3.6J3.7
Combined tension and shear, bearing-typeJ3.7J3.8
Slip-critical bolts, Eq. J3-4J3.8J3.9
Combined tension and shear, slip-criticalJ3.9J3.10
Bearing and tear-out at bolt holes, Eq. J3-6a to J3-6fJ3.10J3.11
Fillet weld group with longitudinal and transverse weldsJ2.4(c), Eq. J2-10J2.4(b), Eq. J2-6
Directional strength increase of fillet welds, [mathin]k_{ds}[mathin]J2.4(b)J2.4(a)
Lateral-torsional buckling of plates and coped sectionsEq. F11-2, F11-3, F11-4Eq. F11-3, F11-4, F11-5
Effective widths at an HSS wall, [mathin]B_{e}[mathin] and [mathin]B_{ep}[mathin]cited as AISC Manual 15th Ed. Eq. K1-1, K1-2AISC 360-22 Eq. K1-1, K1-2
Maximum fillet weld size for base metal strengthAISC Manual 15th Ed. Eq. 9-2AISC Manual 16th Ed. Eq. 9-6
Other AISC Manual references (Parts 7, 9, 10, 15)15th Ed. page and equation16th Ed. Part number

Sections that keep their numbers, such as J2.4 Eq. J2-4, J4.1 to J4.4, J5.2 (filler factor [mathin]h_{f}[mathin]), J10, D3, F13.1 and K5, are only relabelled from 360-16 to 360-22. The minimum fillet weld sizes of Table J2.4 and the imperial bolt strengths of Table J3.2 are the same in both editions.

Bolt grades in the bolt list

Two things in the bolt input depend on the edition:

  • ASTM F3148 (Group 144) is listed only under AISC 360-22: [mathin]F_{nt} = 108\ \text{ksi}[mathin] (750 MPa), [mathin]F_{nv} = 65\ \text{ksi}[mathin] (450 MPa) with threads included and 81 ksi (560 MPa) with threads excluded.
  • Metric bolt strengths follow the rounded 360-22 values of Table J3.2: [mathin]F_{nv}[mathin] = 190 MPa for A307, 370 / 470 MPa for Group 120 (A325) and 470 / 580 MPa for Group 150 (A490), threads included / excluded. Under 360-16 the list uses 188, 372 / 469 and 469 / 579 MPa. Metric jobs with bearing-type bolts can therefore show small differences in bolt shear between the editions.

Example 1: single plate shear and axial connection, no change

The single plate shear and axial example (W18x50 to a W14x90 flange, ten 1 in A490-SC bolts, [mathin]V_{u} = 38\ \text{kip}[mathin], [mathin]T_{u} = C_{u} = 132\ \text{kip}[mathin], LRFD) was run under both editions. Every check in the summary gives the same demand, capacity and DCR. Only the references move:

Check360-16 reference360-22 referenceCapacity (both)DCR (both)
Slip-critical bolt group (highest strength DCR)J3.8 Eq. J3-4J3.9 Eq. J3-4158.413 kip0.867
Bearing and tear-out on the plate, shearJ3.10 Eq. J3-6a, J3-6cJ3.11 Eq. J3-6a, J3-6c423.997 kip0.090
Bearing and tear-out on the beam web, axial tensionJ3.10J3.11250.865 kip0.526
Plate in flexure (double coped procedure)F11.2 Eq. F11-2F11.2 Eq. F11-3420.743 kip0.090
Beam web block shear, axialJ4.3 Eq. J4-5J4.3 Eq. J4-5181.932 kip0.726
Weld to the column flangeJ2.4 Eq. J2-4; Manual 15th Ed. Eq. 9-2J2.4 Eq. J2-4; Manual 16th Ed. Eq. 9-6294.375 kip0.467

The same holds for the end plate shear and axial example: every value is identical, with bolt shear relabelled from J3.6 to J3.7 and the modified bolt shear strength [mathin]F’_{nv}[mathin] from J3.7 to J3.8.

Example 2: flange plate moment connection to an HSS column

The HSS column flange plate example frames a W18x50 into the 4 in face of an HSS8x4x1/2 ([mathin]t = 0.465\ \text{in}[mathin]) with 3/4 in Grade 50 flange plates, 6.5 in wide, and a flange force [mathin]P_{uF} = 59.162\ \text{kip}[mathin]. Only the plate local yielding check changes. The effective plate width is the HSS wall, [mathin]B_{p,eff} = 4\ \text{in}[mathin], in both runs.

AISC 360-16:

[math]\phi R_{n} = 0.95 \times \min\left( \frac{10 \times 0.465^{2} \times 50 \times 4}{4},\ 50 \times 0.75 \times 4 \right) = 102.71\ \text{kip}[math]

DCR = 59.162 kip / 102.71 kip = 0.576 ≤ 1.0, OK

AISC 360-22, Section K2.3 to J4.1 over [mathin]B_{e}[mathin]. The expression is the same, since [mathin]F_{yp} t_{fp} B_{e}[mathin] with [mathin]B_{e}[mathin] from Eq. K1-1 equals the first term; only [mathin]\phi[mathin] changes:

[math]\phi R_{n} = 0.9 \times \min\left( \frac{10 \times 0.465^{2} \times 50 \times 4}{4},\ 50 \times 0.75 \times 4 \right) = 97.301\ \text{kip}[math]

DCR = 59.162 kip / 97.301 kip = 0.608 ≤ 1.0, OK

The 6.5 in plate is wider than the 4 in face, so [mathin]B_{p} \le B – 2t[mathin] is not met and the 360-22 punching check is not added. Every other check is identical:

Check360-16 capacity360-22 capacityDCR 360-16DCR 360-22
Flange bolts, slip-critical (highest strength DCR; J3.8 / J3.9)62.7014 kip62.7014 kip0.9440.944
Weld to the HSS column (J2.4, K5)63.1436 kip63.1436 kip0.9370.937
**Flange plate local yielding****102.707 kip****97.3012 kip****0.576****0.608**
HSS sidewalls, local yielding197.044 kip197.044 kip0.3000.300
Beam flange in tension (D3, J4.1)82.7258 kip82.7258 kip0.7150.715
Shear plate in shear (J4.2)53.2195 kip53.2195 kip0.3570.357

The highest strength DCR stays with the flange bolts under both editions, so the connection design does not change. The flange plate local yielding check would govern under 360-22 only where the HSS wall is thin compared with the flange plate force.

What this means for your designs

  • A connection designed to 360-16 that does not involve a rectangular HSS column or an HSS brace on a single gusset gives the same results under 360-22. Re-running it updates the clause references in the report.
  • For flange plates on a rectangular HSS column, expect the plate local yielding capacity to drop by the ratio 0.90 / 0.95 under LRFD, and check the new punching check when the plate is narrower than the flat of the face.
  • For HSS braces slotted onto a gusset, the 360-22 shear lag factor no longer needs a weld at least as long as the brace depth.

Frequently asked questions

Does AISC 360-22 change bolt bearing or tear-out?

Not in the program. Eq. J3-6a to J3-6f are the same in both editions. Only the section number changes, from J3.10 to J3.11.

Why do my imperial bolt shear values not change but metric ones do?

The imperial values of Table J3.2 are the same in both editions. The metric bolt strengths in the bolt list follow the rounded 360-22 values under 360-22, so a metric bearing-type bolt can differ by a few MPa.

Can I still design to AISC 360-16?

Yes. Both editions stay in the Design Code list, and the 360-16 results are unchanged.

Compare the editions on your own connection

Open any AISC connection, run it under AISC 360-16 and then under AISC 360-22, and compare the two calculation reports check by check. There is nothing to install.

The SkyCiv Connection Design module gives you the full calculation report with every equation and your numbers in it, to either edition. Auto Design sizes AISC connections to the edition you select.

References

  • AISC 360-16, Specification for Structural Steel Buildings: Sections D3, F11, J2.4, J3.2 to J3.10, J4.1 to J4.4, J5.2, J10, K1, K5.
  • AISC 360-22, Specification for Structural Steel Buildings: Sections D3 (Table D3.1 Case 5), F11, J2.4, J3.3 to J3.11, J4.1 to J4.4, J5.2, J10, K1.2a (Eq. K1-1, K1-2), K2.3, K5.
  • AISC Steel Construction Manual, 15th and 16th Editions.
  • AISC Design Guide 24, Hollow Structural Section Connections (360-16 plate local yielding factor).
  • Single plate shear and axial connection design example