This example designs a shear end plate connection to AISC 360-16 ASD. The plate is welded to the beam web and bolted to the column flange. At the beam you check the fillet welds and the beam web in shear. At the support you check bolt shear, bolt bearing and tear-out on the plate and the column flange, block shear, shear and flexure of the plate, and shear and moment interaction, plus the detailing limits on both sides. Every strength is an allowable strength, the nominal strength divided by a safety factor.

The connection is a W18x50 beam framing into the flange of a W14x90 column with a 26 kip ASD reaction. It uses a 3/8 in x 8 1/2 in x 9 in A36 end plate, welded to the beam web with 3/16 in E70XX fillets on both sides and bolted to the column with six 3/4 in A325-N bolts in two columns of three. The design is to AISC 360-16 and the AISC Manual 15th Edition. Every equation is written out with its numbers, in the same order as the AISC calc sheet the SkyCiv Connection Design module produces for it. The LRFD version works the same beam and column with a deeper plate and a much larger factored reaction.

What is a shear end plate connection?

A shear end plate connection is a single plate shop welded square to the end of the beam web and field bolted to the support. The plate fits within the flat part of the beam web, with one column of bolts on each side of the web. It carries the beam’s end shear and is a simple connection under AISC 360-16 B3.4. The plate is kept thin so it can flex as the beam end rotates, which keeps moment out of the support.

It is different from a moment end plate. A moment connection such as a flush or extended end plate welds the plate to the beam flanges too and uses a much thicker plate. A shear end plate is welded to the web only. It is one type of shear connection, alongside the single plate (shear tab) connection, the double angle connection and the single angle connection. You can check this example directly in the end plate connection calculator.

Shear end plate elevation: W18x50 beam with a 3/8 x 8 1/2 x 9 in A36 end plate bolted to a W14x90 flange

Elevation of the example connection. The end plate is welded to the beam web in the shop and bolted to the column flange in the field.

Section A-A through the shear end plate: six 3/4 in A325-N bolts at a 5 1/2 in gage and 3 in row spacing

Section A-A. Two columns of three bolts at a 5 1/2 in gage, with 1 1/2 in edge distances all round the plate.

SkyCiv Connection Design 3D view of the shear end plate connection, W18x50 beam to W14x90 column flange

The same connection in the SkyCiv Connection Design 3D view.

How do you design a shear end plate connection? The steps at a glance

  1. Check the detailing limit at the beam side: the minimum plate depth.
  2. Check the fillet welds from the end plate to the beam web.
  3. Check the beam web in shear yielding.
  4. Check the detailing limits at the support side: spacing, edge distances and gage.
  5. Check the bolt group in shear.
  6. Check bolt bearing and tear-out on the end plate.
  7. Check bolt bearing and tear-out on the column flange.
  8. Combine shear, bearing and tear-out per bolt for the effective group strength.
  9. Check block shear of the end plate.
  10. Check shear yielding and shear rupture of the end plate.
  11. Check end plate flexure using the double coped procedure.
  12. Check shear and moment interaction of the end plate.

Design inputs for this example

The design code is AISC 360-16 ASD, so the load is the ASD load combination reaction and each strength is divided by its safety factor, Ω. Section properties are from the AISC Manual.

ItemSymbolValue
Vertical shear (ASD load combination)[mathin] V_{a} [mathin]26 kip
BeamW18x50, A992
Beam depth / web thickness[mathin] d_{bm},\ t_{wb} [mathin]18 in / 0.355 in
Beam T dimension / k (detailing)[mathin] T_{bm},\ k_{det} [mathin]15.5 in / 1.25 in
Beam yield / tensile stress[mathin] F_{yb},\ F_{ub} [mathin]50 ksi / 65 ksi
ColumnW14x90, A992
Column flange width / thickness[mathin] b_{fs},\ t_{fs} [mathin]14.5 in / 0.71 in
Column yield / tensile stress[mathin] F_{ys},\ F_{us} [mathin]50 ksi / 65 ksi
Modulus of elasticity[mathin] E [mathin]29000 ksi
ItemSymbolValue
End platePL 3/8 x 8 1/2 x 9, A36
End plate width / depth / thickness[mathin] b_{p},\ d_{p},\ t_{p} [mathin]8.5 in / 9 in / 0.375 in
End plate yield / tensile stress[mathin] F_{yp},\ F_{up} [mathin]36 ksi / 58 ksi
Bolts3/4 in A325-N, single shear
Bolt diameter / nominal shear stress[mathin] d_{b},\ F_{nv} [mathin]0.75 in / 54 ksi
Holes in plate / columnShort-slotted horizontal (HSSL) / standard (STD)
Weld3/16 in fillet, both sides of the web, E70XX
Weld size / filler strength[mathin] W,\ F_{EXX} [mathin]0.1875 in / 70 ksi
GeometrySymbolValue
Bolt rows / row spacing[mathin] n_{r},\ s_{r} [mathin]3 / 3 in
Bolt columns / gage[mathin] n_{c},\ g_{a} [mathin]2 / 5.5 in
Vertical / horizontal edge distance on plate[mathin] L_{ev},\ L_{eh} [mathin]1.5 in / 1.5 in

The plate width is the two 1.5 in edge distances plus the 5.5 in gage, 8.5 in. The depth is the two 1.5 in edge distances plus two 3 in spaces, 9 in.

Step 1: Detailing limit at the beam side

The end plate has to be at least half the beam’s T dimension deep, so it gives the beam web enough restraint while still fitting inside the flat part of the web.

[math] d_{p,min} = \frac{T_{bm}}{2} = \frac{15.5\ \text{in}}{2} = 7.75\ \text{in} \qquad DCR = \frac{7.75\ \text{in}}{9\ \text{in}} = 0.861 [math]

DCR = 0.861 < 1.0, OK

Step 2: Fillet weld from the end plate to the beam web (AISC 360-16 J2.4)

The plate is welded to the beam web with a fillet weld on each face of the web. The weld transfers the whole reaction from the web into the plate.

Base metal limit on weld size (AISC Manual Eq. 9-2)

The largest weld size, in sixteenths of an inch, the connected parts can support. The end plate has one weld on its face against each side of the web, so the full plate thickness counts. The web has a weld on each face, so each weld gets half the web thickness.

[math] D_{max} = \frac{\min\left( t_{p} F_{up},\; \frac{t_{wb}}{2} F_{ub} \right)}{3.09\ \text{kip/in} \times \left( F_{EXX}/70\ \text{ksi} \right)} = \frac{\min\left( (0.375\ \text{in})(58\ \text{ksi}),\; (0.1775\ \text{in})(65\ \text{ksi}) \right)}{(3.09\ \text{kip/in})(1)} = 3.7338 [math]

That is 3.7338/16 = 0.2334 in, more than the 3/16 in weld, so the full weld size counts.

Effective weld length

The weld runs down both sides of the web over the plate depth, but not past the flat part of the web (the T dimension), and not into the fillets at the flanges (the k distance). Each line loses 2W at its ends:

[math] L_{w} = 2 \left[ \min\left( d_{p},\, T_{bm},\, d_{bm} – k_{det} – k_{det} \right) – 2W \right] = 2 \times \left[ \min\left( 9,\, 15.5,\, 18 – 1.25 – 1.25 \right) – 2 \times 0.1875 \right] = 17.25\ \text{in} [math]

The beam is not coped, so the cope depths in the calc sheet’s formula are zero and the k distance controls at each flange.

Weld strength

The load runs parallel to the welds, so [mathin] \theta = 0 [mathin] and there is no directional increase:

[math] \frac{R_{n}}{\Omega} = \frac{0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left( W,\, \frac{D_{max}}{16} \right) \left[ 1 + 0.5 \sin^{1.5}\theta \right] L_{w}}{\Omega} [math]

[math] \frac{R_{n}}{\Omega} = \frac{0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left( 0.1875\ \text{in},\, \frac{3.7338}{16} \right) \times \left[ 1 + 0 \right] \times (17.25\ \text{in})}{2.00} = 48.028\ \text{kip} [math]

DCR = 26 kip / 48.028 kip = 0.541 < 1.0, OK

Step 3: Beam web in shear yielding (AISC 360-16 J4.2)

The beam web carries the reaction into the weld, so its gross area is checked for shear yielding. The beam has no cope and no holes at the end, so only yielding is checked.

[math] A_{gv} = d_{bm}\, t_{wb} = (18\ \text{in}) \times (0.355\ \text{in}) = 6.39\ \text{in}^{2} [math]

[math] \frac{R_{n,sy}}{\Omega} = \frac{0.6\, F_{yb} A_{gv}}{\Omega} = \frac{0.6 \times (50\ \text{ksi}) \times (6.39\ \text{in}^{2})}{1.50} = 127.8\ \text{kip} [math]

DCR = 26 kip / 127.8 kip = 0.203 < 1.0, OK

Step 4: Detailing limits at the support side (AISC 360-16 J3.3, J3.4, J3.5)

The bolts need minimum and maximum spacing and minimum edge distances. The gage also has two minimums: one for the bolts at the column, and one so the bolts on either side of the web can be installed.

Detailing limitLimit (in)Actual (in)DCRResult
Minimum bolt row spacing2.0003.0000.667PASS
Maximum bolt row spacing6.0003.0000.500PASS
Plate minimum vertical edge distance1.0001.5000.667PASS
Plate minimum horizontal edge distance1.1251.5000.750PASS
Support minimum horizontal edge distance1.0004.5000.222PASS
Minimum bolt gage at support4.3755.5000.795PASS
Minimum bolt gage at end plate2.2305.5000.405PASS

The horizontal edge distance on the plate is measured across the short slot, so Table J3.5 adds 1/8 in to the 1 in from Table J3.4. The governing row is the minimum gage at the support:

[math] DCR = \frac{4.375\ \text{in}}{5.5\ \text{in}} = 0.795 [math]

DCR = 0.795 < 1.0, OK

Step 5: Bolt group shear at the support side (AISC 360-16 J3.6)

Each bolt passes through the end plate and the column flange, one shear plane, so [mathin] N_{s} = 1 [mathin]. The reaction acts at the column face and the bolts are symmetric about the web, so there is no eccentricity and every bolt takes an equal share. With no fillers, [mathin] h_{f} = 1 [mathin] (J5.2(a)).

[math] \frac{R_{n}}{\Omega} = \frac{F_{nv}\, \frac{\pi}{4} d_{b}^{2}\, N_{s}\, N_{V}\, h_{f}}{\Omega} [math]

[math] \frac{R_{n}}{\Omega} = \frac{(54\ \text{ksi}) \times \frac{\pi}{4} (0.75\ \text{in})^{2} \times (1) \times (6) \times (1)}{2} [math]

[math] \frac{R_{n}}{\Omega} = 71.569\ \text{kip} [math]

DCR = 26 kip / 71.569 kip = 0.363 < 1.0, OK

Step 6: Bolt bearing and tear-out on the end plate (AISC 360-16 J3.10)

The edge bolt tears out to the bottom of the plate, and the others tear out to the next hole. The slots run horizontally, so the hole dimension across the member length is [mathin] d_{h} = 0.8125\ \text{in} [mathin].

[math] l_{c1} = L_{ev} – \frac{d_{h}}{2} = 1.5\ \text{in} – \frac{0.8125\ \text{in}}{2} = 1.0938\ \text{in} [math]

[math] l_{c2} = s_{r} – d_{h} = 3\ \text{in} – 0.8125\ \text{in} = 2.1875\ \text{in} [math]

The strength of one column of bolts, times the number of columns:

[math] \frac{R_{n}}{\Omega} = \frac{\left[ \min\left(1.2\, l_{c1},\, 2.4\, d_{b}\right) t_{p} F_{up} + \min\left(1.2\, l_{c2},\, 2.4\, d_{b}\right) t_{p} F_{up} \left( n_{r} – 1 \right) \right] \frac{N_{V}}{n_{r}}}{\Omega} [math]

[math] \frac{R_{n}}{\Omega} = \frac{\left[ \min\left(1.3125,\, 1.8\right)(0.375)(58) + \min\left(2.625,\, 1.8\right)(0.375)(58)(3 – 1) \right] \times \frac{6}{3}}{2} [math]

[math] \frac{R_{n}}{\Omega} = 106.85\ \text{kip} [math]

DCR = 26 kip / 106.85 kip = 0.243 < 1.0, OK

Step 7: Bolt bearing and tear-out on the column flange (AISC 360-16 J3.10)

The column flange has no edge in the direction of the load, so every bolt bears as an inner bolt.

[math] l_{c2} = s_{r} – d_{h} = 3\ \text{in} – 0.8125\ \text{in} = 2.1875\ \text{in} [math]

[math] \frac{R_{n}}{\Omega} = \frac{\min\left(1.2\, l_{c2},\, 2.4\, d_{b}\right) t_{fs} F_{us} N_{V}}{\Omega} [math]

[math] \frac{R_{n}}{\Omega} = \frac{\min\left(1.2 \times 2.1875\ \text{in},\, 2.4 \times 0.75\ \text{in}\right) \times (0.71\ \text{in}) \times (65\ \text{ksi}) \times (6)}{2} [math]

[math] \frac{R_{n}}{\Omega} = 249.21\ \text{kip} [math]

DCR = 26 kip / 249.21 kip = 0.104 < 1.0, OK

Step 8: Effective strength of the bolt group (AISC 360-16 J3.6 Commentary)

Each bolt delivers the least of its shear strength, its bearing or tear-out strength on the end plate, and its bearing strength on the column flange. The group strength is the sum of those per-bolt values.

[math] \frac{r_{v}}{\Omega} = \frac{71.569\ \text{kip}}{6} = 11.928\ \text{kip} [math]

[math] \frac{r_{n1e}}{\Omega} = \frac{\min\left(1.3125,\, 1.8\right)(0.375)(58)}{2} = 14.273\ \text{kip} \qquad \frac{r_{n1i}}{\Omega} = \frac{\min\left(2.625,\, 1.8\right)(0.375)(58)}{2} = 19.575\ \text{kip} [math]

[math] \frac{r_{n2}}{\Omega} = \frac{\min\left(2.625,\, 1.8\right)(0.71)(65)}{2} = 41.535\ \text{kip} [math]

Bolts are numbered from the top of the column, so bolt 3 is the edge bolt on the plate:

BoltBolt shear (kip)Bearing / tear-out on the end plate (kip)Bearing on the column flange (kip)Effective strength (kip)
1, 211.9319.5741.5311.93
311.9314.2741.5311.93

[math] \sum \frac{r_{eff}}{\Omega} = (2) \times (11.928\ \text{kip}) + (1) \times (11.928\ \text{kip}) = 35.785\ \text{kip} [math]

[math] \frac{R_{n,eff}}{\Omega} = \frac{N_{V}}{n_{r}} \sum \frac{r_{eff}}{\Omega} = \frac{6}{3} \times (35.785\ \text{kip}) = 71.569\ \text{kip} [math]

DCR = 26 kip / 71.569 kip = 0.363 < 1.0, OK

Every bolt is limited by bolt shear, so the effective strength equals the bolt group shear strength in Step 5.

Step 9: Block shear of the end plate (AISC 360-16 J4.3)

On each side of the web, a block of plate can tear out: shear down the bolt line and tension across to the plate edge. Both sides are added, so the areas use [mathin] 2t_{p} = 0.75\ \text{in} [mathin]. The tension area uses the slot length along the member, [mathin] d_{h} = 1\ \text{in} [mathin], and the shear areas use [mathin] d_{h} = 0.8125\ \text{in} [mathin]. Each hole adds 0.0625 in for damage (B4.3).

[math] A_{nt} = 2t_{p} \left[ L_{eh} – 0.5\left( d_{h} + 0.0625\ \text{in} \right) \right] = (0.75) \times \left[ 1.5 – 0.5 (1.0625) \right] = 0.72656\ \text{in}^{2} [math]

[math] A_{gv} = 2t_{p} \left[ L_{ev} + (n_{r}-1) s_{r} \right] = (0.75) \times \left[ 1.5 + (2)(3) \right] = 5.625\ \text{in}^{2} [math]

[math] A_{nv} = 2t_{p} \left[ d_{p} – L_{ev} – (n_{r}-0.5)\left( d_{h} + 0.0625\ \text{in} \right) \right] = (0.75) \times \left[ 9 – 1.5 – (2.5)(0.875) \right] = 3.9844\ \text{in}^{2} [math]

[math] \frac{R_{n}}{\Omega} = \frac{\min\left( 0.6 F_{up} A_{nv},\; 0.6 F_{yp} A_{gv} \right) + U_{bs} F_{up} A_{nt}}{\Omega} [math]

[math] \frac{R_{n}}{\Omega} = \frac{\min\left( 0.6 \times 58 \times 3.9844,\; 0.6 \times 36 \times 5.625 \right) + 1 \times 58 \times 0.72656}{2} [math]

[math] \frac{R_{n}}{\Omega} = 81.82\ \text{kip} [math]

DCR = 26 kip / 81.82 kip = 0.318 < 1.0, OK

with [mathin] U_{bs} = 1 [mathin]. Shear yielding on the gross area is the lower branch, so it sets the strength.

Step 10: Shear yielding and shear rupture of the end plate (AISC 360-16 J4.2)

The plate carries the reaction in vertical shear on both sides of the web, [mathin] n_{sp} = 2 [mathin] shear planes.

[math] A_{gv} = d_{p}\, n_{sp} t_{p} = (9\ \text{in}) \times (0.75\ \text{in}) = 6.75\ \text{in}^{2} \qquad \frac{R_{n,sy}}{\Omega} = \frac{0.6 \times (36\ \text{ksi}) \times (6.75\ \text{in}^{2})}{1.50} = 97.2\ \text{kip} [math]

[math] A_{nv} = n_{sp} t_{p} \left[ d_{p} – n_{r}\left( d_{h} + 0.0625\ \text{in} \right) \right] = (0.75\ \text{in}) \times \left[ 9\ \text{in} – 3 \times (0.875\ \text{in}) \right] = 4.7813\ \text{in}^{2} [math]

[math] \frac{R_{n,sr}}{\Omega} = \frac{0.6 \times (58\ \text{ksi}) \times (4.7813\ \text{in}^{2})}{2.00} = 83.194\ \text{kip} [math]

[math] \frac{R_{n}}{\Omega} = \min\left( 97.2\ \text{kip},\, 83.194\ \text{kip} \right) = 83.194\ \text{kip} [math]

DCR = 26 kip / 83.194 kip = 0.313 < 1.0, OK

Step 11: End plate flexure using the double coped procedure (AISC 360-16 F11.2)

Each half of the plate bends between the bolt line and the face of the web. The unbraced length is half the gage less half the web thickness, [mathin] L_{b} = (5.5 – 0.355)/2 = 2.5725\ \text{in} [mathin]. Each half is treated like a beam web with both flanges coped, and the two halves are added.

Range check

[math] \frac{L_{b} d}{t^{2}} = \frac{(2.5725\ \text{in})(9\ \text{in})}{(0.375\ \text{in})^{2}} = 164.64 [math]

[math] \frac{0.08 E}{F_{y}} = \frac{0.08 \times 29000\ \text{ksi}}{36\ \text{ksi}} = 64.444 \lt 164.64 \le \frac{1.9 E}{F_{y}} = \frac{1.9 \times 29000\ \text{ksi}}{36\ \text{ksi}} = 1530.6 [math]

Section moduli of the end plate

[math] Z = \frac{t_{p} d_{p}^{2}}{4} = \frac{(0.375\ \text{in})(9\ \text{in})^{2}}{4} = 7.5938\ \text{in}^{3} \qquad S = \frac{t_{p} d_{p}^{2}}{6} = \frac{(0.375\ \text{in})(9\ \text{in})^{2}}{6} = 5.0625\ \text{in}^{3} [math]

Lateral-torsional buckling modification factor (AISC Manual Eq. 9-15)

[math] C_{b} = \left[ 3 + \ln\left( \frac{2.5725\ \text{in}}{9\ \text{in}} \right) \right] \times \left( 1 – \frac{0}{9} \right) \ge 1.84 \;\Rightarrow\; C_{b} = 1.84 [math]

Flexural strength (Eq. F11-2)

[math] \frac{M_{n}}{\Omega} = 2\, \frac{\min\left\{ C_{b} \left[ 1.52 – 0.274 \left( \frac{L_{b} d}{t^{2}} \right) \frac{F_{yp}}{E} \right] F_{yp} S,\; F_{yp} Z \right\}}{\Omega} [math]

[math] \frac{M_{n}}{\Omega} = 2 \times \frac{\min\left\{ (1.84) \left[ 1.52 – 0.274 \times (164.64) \times \frac{36}{29000} \right] (36)(5.0625),\; (36)(7.5938) \right\}}{1.67} = 27.283\ \text{kip-ft} [math]

The plastic moment governs, so the plate does not buckle sideways at this length.

Equivalent shear capacity

[math] \frac{V_{n}}{\Omega} = \frac{\frac{M_{n}}{\Omega}}{L_{b}} = \frac{27.283\ \text{kip-ft} \;(327.40\ \text{kip-in})}{2.5725\ \text{in}} = 127.27\ \text{kip} [math]

DCR = 26 kip / 127.27 kip = 0.204 < 1.0, OK

Step 12: Shear and moment interaction of the end plate (AISC Manual Eq. 10-5)

The plate carries shear and bending at the same section, so the two are combined with the shear yielding strength and the flexural strength:

[math] M_{r} = V_{a} L_{b} = (26\ \text{kip}) \times (2.5725\ \text{in}) = 5.5737\ \text{kip-ft} [math]

[math] I_{nt} = \left( \frac{V_{a}}{\frac{R_{n,sy}}{\Omega}} \right)^{2} + \left( \frac{M_{r}}{\frac{M_{n}}{\Omega}} \right)^{2} = \left( \frac{26\ \text{kip}}{97.2\ \text{kip}} \right)^{2} + \left( \frac{5.5737\ \text{kip-ft}}{27.283\ \text{kip-ft}} \right)^{2} = 0.113 [math]

DCR = 0.113 < 1.0, OK

Summary of design checks

Design checkDemandAllowable strengthDCRResult
1. Detailing limit at the beam side7.75 in9 in0.861PASS
**2. Fillet weld to the beam web****26 kip****48.028 kip****0.541****PASS**
3. Beam web shear yielding26 kip127.80 kip0.203PASS
4. Detailing limits at the support side4.375 in5.5 in0.795PASS
5. Bolt group shear26 kip71.569 kip0.363PASS
6. Bearing and tear-out on the end plate26 kip106.85 kip0.243PASS
7. Bearing and tear-out on the column flange26 kip249.21 kip0.104PASS
8. Effective strength of the bolt group26 kip71.569 kip0.363PASS
9. Block shear of the end plate26 kip81.820 kip0.318PASS
10. End plate shear yielding and rupture26 kip83.194 kip0.313PASS
11. End plate flexure26 kip127.27 kip0.204PASS
12. Shear and moment interaction0.1131.0000.113PASS

The connection passes every check. The fillet weld to the beam web governs the strength checks at 0.541, then bolt shear and the effective bolt group strength at 0.363. The plate checks sit around 0.31 to 0.32. The minimum plate depth is the highest ratio on the page at 0.861, because the 9 in plate is not much deeper than half the beam’s T dimension.

What to change if a check fails

  • Fillet weld: a deeper plate gives a longer weld. A larger weld only helps up to the base metal limit set by half the beam web thickness.
  • Beam web shear: this depends on the beam, so a heavier section is the only fix.
  • Bolt shear or effective strength: add a bolt row or use a larger bolt.
  • Tear-out at the edge bolt: increase the vertical edge distance on the plate.
  • Block shear or shear rupture of the plate: make the plate deeper with another bolt row, or thicker.
  • Plate flexure: a thicker plate or a smaller gage. Keep the gage above both minimums in Step 4.
  • Minimum gage at the support: widen the gage, which also widens the plate to keep the edge distance.

Auto Design is available for the shear end plate connection to a column flange. It changes the connection’s design variables until every check passes, and keeps your members and loads as entered. See the Auto Design page for the preferences it works to.

Frequently asked questions

How does this ASD example differ from the LRFD version?

The limit states and the nominal strengths are the same. In ASD the load is the ASD load combination reaction, and each nominal strength is divided by a safety factor instead of multiplied by a resistance factor: Ω = 2.00 where LRFD uses φ = 0.75, Ω = 1.50 for shear yielding where LRFD uses φ = 1.00, and Ω = 1.67 for flexure where LRFD uses φ = 0.90. The LRFD version uses the same W18x50 beam and W14x90 column with a deeper end plate and a much larger factored reaction, so its numbers are not a direct conversion of these.

What is the difference between a shear end plate and a moment end plate?

A shear end plate is welded to the beam web only and is thin enough to flex, so it carries shear and no significant moment. A moment end plate is also welded to the beam flanges and is much thicker, so it transfers the flange forces as well.

Why is there no bolt group eccentricity in this example?

The bolts are at the column face, where the reaction is delivered, and they are symmetric about the beam web. So the bolt group carries pure shear and each bolt takes an equal share.

Why does the end plate have short-slotted holes?

Horizontal short slots give the erector some fit-up tolerance and let the plate flex as the beam end rotates. Because they run across the vertical load, bearing and tear-out use the hole dimension across the slot, and block shear tension uses the slot length.

Which check usually governs a shear end plate connection?

The weld to the beam web often governs, because it is limited by half the web thickness in base metal shear. On a thick-webbed beam, bolt shear or shear rupture of the plate usually takes over.

Does this example follow the AISC 15th edition or the AISC 16th edition Manual?

It follows AISC 360-16 and the AISC Manual 15th Edition, which is written around that Specification. The AISC 16th Edition Manual pairs with the later 360-22 Specification. The limit states for a shear end plate are the same in both, but clause and page references move, so check them against the edition your project uses.

Design a shear end plate connection for free

Every number on this page comes from one solve. Pick the end plate configuration, choose AISC 360-16 ASD, enter your beam, support, plate, weld, bolts and reaction, and see each of these checks in your browser. There is nothing to install.

The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every capacity and DCR, for AISC 360-22 and AISC 360-16 (LRFD and ASD) and AS 4100:2020. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.

References

Harold Munalem, Product Manager for SkyCiv Connection Design

Harold Munalem
Product Manager, Connection Design
10+ years in steel connection design
LinkedIn

How can we help?

×

Updated November 24, 2026

Still stuck? Contact us

Go to Top