SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

Double Angle Connection Design (Metric)

This example designs a double angle connection to AISC 360-16 LRFD in SI units. The two clip angles are shop-welded to the beam web and field-bolted to the column flange, so the beam side is a weld group and the support side is a bolt group. On the beam side you check the weld, and shear and flexure of the angles. On the support side you check bolt shear, bearing and tear-out, block shear, shear and flexure of the angles, plus the detailing limits on both sides.

The connection is a W18x35 beam framing into the flange of a W14x90 column with a 142 kN factored reaction. It uses 2L4x3-1/2×5/16 A36M angles 230 mm long, welded to the beam web with 5 mm E70XX fillets and bolted to the column with six M20 A325-N bolts. The design is to AISC 360-16 and the AISC Manual 15th Edition, with dimensions in millimetres, forces in kN and stresses in MPa. Every equation is written out with its numbers, in the same order as the AISC calc sheet the SkyCiv Connection Design module produces for it. The LRFD version works a double angle connection in US customary units that is bolted on both sides.

What is a double angle connection?

A double angle connection is a pair of steel angles, one on each side of the beam web, with one leg attached to the web and the other leg bolted to the supporting member. It transfers the beam’s end shear and is classified as a simple connection under AISC 360-16 B3.4, so the angles are detailed to flex rather than resist moment. Here the legs on the beam are welded in the shop, which removes the beam-side bolts and their holes from the web.

It is a common shear connection for beams framing into column flanges, column webs and girders. The beam web sits between the two angles, so the connection is symmetric and does not twist the beam. The other options for the same job are the single plate (shear tab) connection, the single angle connection and the shear end plate connection. You can check this example directly in the double angle connection calculator.

Double angle elevation: W18x35 beam with 2L4x3-1/2x5/16 A36M angles welded to the web and bolted to a W14x90 flange

Elevation of the example connection. The angles are welded to the beam web in the shop and bolted to the column flange, with a 12 mm clearance between the beam end and the column.

Section A-A through the double angle connection: angle legs bolted to the W14x90 flange with M20 A325-N bolts

Section A-A. The outstanding legs are bolted to the column flange through horizontal short-slotted holes. The drawing rounds the 135.64 mm gage to 136 mm.

SkyCiv Connection Design 3D view of the double angle connection, W18x35 beam to W14x90 column flange

The same connection in the SkyCiv Connection Design 3D view.

How do you design a double angle connection? The steps at a glance

  1. Check the detailing limits at the beam side: connection depth and weld size.
  2. Check the weld group strength at the beam with the instantaneous center of rotation.
  3. Check shear yielding and shear rupture of the angles at the beam side.
  4. Check flexure of the angles at the beam side using the double coped procedure.
  5. Check shear and moment interaction of the angles at the beam side.
  6. Check the detailing limits at the support side: spacing, edge distances and gage.
  7. Check the bolt group in shear.
  8. Check bolt bearing and tear-out on the angles.
  9. Check bolt bearing and tear-out on the column flange.
  10. Combine shear, bearing and tear-out per bolt for the effective group strength.
  11. Check block shear of the angles.
  12. Check shear yielding and shear rupture of the angles at the support side.
  13. Check flexure of the angles at the support side.
  14. Check shear and moment interaction of the angles at the support side.

Design inputs for this example

The design code is AISC 360-16 LRFD, so the load is the factored reaction and each strength is multiplied by its resistance factor, φ. The sections are the AISC W shapes and angles, with their dimensions converted to millimetres.

ItemSymbolValue
Factored vertical shear[mathin] V_{u} [mathin]142 kN
BeamW18x35, A992M
Beam depth / web thickness[mathin] d_{bm},\ t_{wb} [mathin]449.58 mm / 7.62 mm
Beam yield / tensile stress[mathin] F_{yb},\ F_{ub} [mathin]345 MPa / 450 MPa
ColumnW14x90, A992M
Column flange width / thickness[mathin] b_{fs},\ t_{fs} [mathin]368.3 mm / 18.034 mm
Column yield / tensile stress[mathin] F_{ys},\ F_{us} [mathin]345 MPa / 450 MPa
Modulus of elasticity[mathin] E [mathin]200000 MPa
ItemSymbolValue
Angles2L4x3-1/2×5/16, A36M, 230 mm long
Angle depth / thickness[mathin] d_{a},\ t_{a} [mathin]230 mm / 7.9502 mm
Leg on the beam / leg on the support[mathin] b_{a,NSL},\ b_{a,OSL} [mathin]88.9 mm / 101.6 mm
Angle yield / tensile stress[mathin] F_{ya},\ F_{ua} [mathin]250 MPa / 400 MPa
Bolts at the columnM20 A325-N
Bolt diameter / nominal shear stress[mathin] d_{b},\ F_{nv} [mathin]20 mm / 372 MPa
Holes in angles / columnShort-slotted horizontal (HSSL) / standard (STD)
Weld at the beam5 mm C-shaped fillet, E70XX
Weld size / filler strength[mathin] W,\ F_{EXX} [mathin]5 mm / 480 MPa
GeometrySymbolValue
Beam web clearance to column[mathin] clr [mathin]12 mm
Weld return / vertical weld length[mathin] kL,\ L [mathin]76.9 mm / 230 mm
Weld group eccentricity[mathin] e [mathin]73.492 mm
Bolt rows / row spacing[mathin] n_{r},\ s_{r} [mathin]3 / 75 mm
Bolt columns per angle[mathin] n_{c} [mathin]1
Gage at the support[mathin] g [mathin]135.64 mm
Vertical / horizontal edge distance on angle[mathin] L_{ev,a},\ L_{eh,a} [mathin]40 mm / 37.59 mm

The angle thickness is the 5/16 in angle converted to millimetres, 7.9502 mm. The horizontal edge distance on the angle follows from the gage: the 101.6 mm leg starts at the face of the beam web, 3.81 mm from its centreline, and the bolt sits half the gage, 67.82 mm, from the centreline, so the edge distance is 3.81 + 101.6 − 67.82 = 37.59 mm.

Step 1: Detailing limits at the beam side (AISC 360-16 J2.2b)

The angles have to be deep enough to give the beam web some rotational restraint and shallow enough to fit within the flat part of the web. The fillet weld along the toe of each angle is limited by the angle thickness, because a weld run along the edge of a plate 1/4 in or thicker can be no larger than the thickness less 1/16 in (J2.2b).

Detailing limitLimit (mm)Actual (mm)DCRResult
Minimum connection depth196.850230.0000.856PASS
Maximum connection depth372.646230.0000.617PASS
Maximum fillet weld size per angle thickness6.3635.0000.786PASS

[math] W_{max} = t_{a} – 1.5875\ \text{mm} = 7.9502\ \text{mm} – 1.5875\ \text{mm} = 6.363\ \text{mm} [math]

The governing row is the minimum connection depth, half the beam’s T dimension:

[math] DCR = \frac{196.85\ \text{mm}}{230\ \text{mm}} = 0.856 [math]

DCR = 0.856 < 1.0, OK

Step 2: Weld group strength at the beam side (AISC Manual Part 8)

Each angle is welded to the beam web with a C-shaped fillet: a vertical weld along the angle toe and a horizontal return at the top and bottom. The reaction acts away from the weld group, so the weld carries a moment as well as shear. The instantaneous center of rotation method gives a coefficient C for the whole group.

Base metal limit on weld size (AISC Manual Eq. 9-2)

The largest weld size, in sixteenths of an inch, that the connected parts can support. Each angle has a weld on one face only, so the full angle thickness counts. The beam web has a weld on each face, so each weld gets half the web thickness, which the calc sheet lists as [mathin] d_{ct} [mathin].

[math] D_{max} = \frac{\min\left( t_{a} F_{ua},\; \frac{t_{wb}}{2} F_{ub} \right)}{0.54114\ \text{kN/mm} \times \left( F_{EXX}/F_{E70XX} \right)} = \frac{\min\left( (7.9502\ \text{mm})(400\ \text{MPa}),\; (3.81\ \text{mm})(450\ \text{MPa}) \right)}{(0.54114\ \text{kN/mm})(1)} = 3.1683 [math]

The 5 mm weld is D = 5 × 16 / 25.4 = 3.1496 sixteenths, just under the 3.1683 limit, so the full weld size counts.

Weld group coefficient

The weld is split into short segments and the IC is found by iteration, with the load-deformation relationship of AISC Manual Eq. (8-3) and the procedure on pages 8-9 to 8-12. For the 76.9 mm returns, the 230 mm vertical weld and the 73.492 mm eccentricity, the iteration converges with:

[math] x_{ic} = -90.427\ \text{mm}, \qquad y_{ic} = 115\ \text{mm}, \qquad C = 0.31598\ \text{kN/mm}^{2} [math]

Weld group strength (AISC Manual Eq. 8-21)

There are two identical weld groups, one per angle, so the length term is twice the vertical weld length. The electrode coefficient is [mathin] C_{1} = 1 [mathin] for E70XX (Manual Table 8-3).

[math] \phi R_{n} = \phi\, C\, C_{1} \min\left( D,\, D_{max} \right) \frac{25.4\ \text{mm}}{16}\, 2L [math]

[math] \phi R_{n} = (0.75) \times (0.31598\ \text{kN/mm}^{2}) \times (1) \times \min\left( 3.1496,\, 3.1683 \right) \times \frac{25.4\ \text{mm}}{16} \times (460\ \text{mm}) [math]

[math] \phi R_{n} = 545.07\ \text{kN} [math]

The 25.4/16 term turns the weld size from sixteenths of an inch back into millimetres.

DCR = 142 kN / 545.07 kN = 0.261 < 1.0, OK

Step 3: Shear yielding and shear rupture of the angles at the beam side (AISC 360-16 J4.2)

The welded legs have no holes, so the net area equals the gross area and both limit states use the same area.

[math] A_{gv} = d_{a}\, 2t_{a} = (230\ \text{mm}) \times (15.9\ \text{mm}) = 3657.1\ \text{mm}^{2} [math]

[math] \phi R_{n,sy} = \phi\, 0.6\, F_{ya} A_{gv} = (1.00) \times 0.6 \times (250\ \text{MPa}) \times (3657.1\ \text{mm}^{2}) = 548.56\ \text{kN} [math]

[math] \phi R_{n,sr} = \phi\, 0.6\, F_{ua} A_{gv} = (0.75) \times 0.6 \times (400\ \text{MPa}) \times (3657.1\ \text{mm}^{2}) = 658.28\ \text{kN} [math]

[math] \phi R_{n} = \min\left( 548.56\ \text{kN},\, 658.28\ \text{kN} \right) = 548.56\ \text{kN} [math]

DCR = 142 kN / 548.56 kN = 0.259 < 1.0, OK

Step 4: Flexure of the angles at the beam side, double coped procedure (AISC 360-16 F11.1)

The calc sheet takes the beam web clearance as the unbraced length on the beam side, [mathin] L_{b} = 12\ \text{mm} [mathin]. Each angle leg is treated like a beam web with both flanges coped, and the two angles are added together.

Range check

[math] \frac{L_{b} d}{t^{2}} = \frac{(12\ \text{mm})(230\ \text{mm})}{(7.9502\ \text{mm})^{2}} = 43.667 [math]

[math] 43.667 \le \frac{0.08 E}{F_{y}} = \frac{0.08 \times 200000\ \text{MPa}}{250\ \text{MPa}} = 64 [math]

The ratio is below the lower limit, so the angle reaches its full yield moment without lateral-torsional buckling and Eq. F11-1 applies.

Section moduli of one angle leg

[math] Z = \frac{t_{a} d_{a}^{2}}{4} = \frac{(7.9502\ \text{mm})(230\ \text{mm})^{2}}{4} = 105140\ \text{mm}^{3} \qquad S = \frac{t_{a} d_{a}^{2}}{6} = \frac{(7.9502\ \text{mm})(230\ \text{mm})^{2}}{6} = 70094\ \text{mm}^{3} [math]

Flexural strength (Eq. F11-1)

[math] \phi M_{n} = \phi \min\left( F_{ya} Z,\; 1.6\, F_{ya} S \right) 2 = (0.9) \times \min\left( (250)(105140),\; 1.6 \times (250)(70094) \right) \times 2 = 47.314\ \text{kN-m} [math]

Equivalent shear capacity

[math] \phi V_{n} = \frac{\phi M_{n}}{L_{b}} = \frac{47.314\ \text{kN-m}}{12\ \text{mm}} = 3942.8\ \text{kN} [math]

DCR = 142 kN / 3942.8 kN = 0.036 < 1.0, OK

Step 5: Shear and moment interaction of the angles at the beam side (AISC Manual Eq. 10-5)

The angles carry shear and bending together at the same section. AISC Manual Eq. 10-5 combines them with the shear yielding strength and the flexural strength:

[math] M_{r} = V_{u} L_{b} = (142\ \text{kN}) \times (12\ \text{mm}) = 1.704\ \text{kN-m} [math]

[math] I_{nt} = \left( \frac{V_{u}}{\phi R_{n,sy}} \right)^{2} + \left( \frac{M_{r}}{\phi M_{n}} \right)^{2} = \left( \frac{142\ \text{kN}}{548.56\ \text{kN}} \right)^{2} + \left( \frac{1.704\ \text{kN-m}}{47.314\ \text{kN-m}} \right)^{2} = 0.0683 [math]

DCR = 0.0683 < 1.0, OK

Step 6: Detailing limits at the support side (AISC 360-16 J3.3, J3.4, J3.5)

The bolts in the outstanding legs need the same spacing and edge distances as any bolt group. The gage across the two angles also has two minimums: one so the bolts clear the column, and one so the bolts can be installed with the beam web between the angles.

Detailing limitLimit (mm)Actual (mm)DCRResult
Minimum bolt row spacing53.33375.0000.711PASS
Maximum bolt row spacing152.40075.0000.492PASS
Angle minimum vertical edge distance26.00040.0000.650PASS
Angle minimum horizontal edge distance29.00037.5900.771PASS
Support minimum horizontal edge distance26.000116.3300.224PASS
Minimum bolt gage at support113.025135.6400.833PASS
Minimum bolt gage for double angle82.862135.6400.611PASS

The horizontal edge distance on the angle is measured across the short slot, so Table J3.5M adds 3 mm to the 26 mm from Table J3.4M. The governing row is the minimum gage at the support:

[math] DCR = \frac{113.025\ \text{mm}}{135.64\ \text{mm}} = 0.833 [math]

DCR = 0.833 < 1.0, OK

Step 7: Bolt group shear at the support side (AISC 360-16 J3.6)

Each bolt passes through one angle leg and the column flange, so it is in single shear, [mathin] N_{s} = 1 [mathin]. There are three rows of bolts in each angle, six bolts in total. The reaction acts at the column face, so there is no eccentricity and every bolt takes an equal share. With no fillers, [mathin] h_{f} = 1 [mathin] (J5.2(a)).

[math] \phi R_{n} = \phi\, F_{nv}\, \frac{\pi}{4} d_{b}^{2}\, N_{s}\, N_{V}\, h_{f} [math]

[math] \phi R_{n} = (0.75) \times (372\ \text{MPa}) \times \frac{\pi}{4} (20\ \text{mm})^{2} \times (1) \times (6) \times (1) [math]

[math] \phi R_{n} = 525.9\ \text{kN} [math]

DCR = 142 kN / 525.9 kN = 0.270 < 1.0, OK

Step 8: Bolt bearing and tear-out on the angles (AISC 360-16 J3.10)

The bolts bear on the angle legs. The edge bolt tears out to the end of the angle, and the others tear out to the next hole. The slots run horizontally, so the hole dimension across the member length is [mathin] d_{h} = 22\ \text{mm} [mathin].

[math] l_{c1} = L_{ev,a} – \frac{d_{h}}{2} = 40\ \text{mm} – \frac{22\ \text{mm}}{2} = 29\ \text{mm} [math]

[math] l_{c2} = s_{r} – d_{h} = 75\ \text{mm} – 22\ \text{mm} = 53\ \text{mm} [math]

The strength of one line of bolts, times the number of lines (one per angle):

[math] \phi R_{n} = \phi\, \left[ \min\left(1.2\, l_{c1},\, 2.4\, d_{b}\right) t_{a} F_{ua} + \min\left(1.2\, l_{c2},\, 2.4\, d_{b}\right) t_{a} F_{ua} \left( n_{r} – 1 \right) \right] \frac{N_{V}}{n_{r}} [math]

[math] \phi R_{n} = (0.75) \times \left[ \min\left(34.8,\, 48\right)(7.9502)(400) + \min\left(63.6,\, 48\right)(7.9502)(400)(3 – 1) \right] \times \frac{6}{3} [math]

[math] \phi R_{n} = 623.93\ \text{kN} [math]

DCR = 142 kN / 623.93 kN = 0.228 < 1.0, OK

Step 9: Bolt bearing and tear-out on the column flange (AISC 360-16 J3.10)

The column flange has no edge in the direction of the load, so every bolt bears as an inner bolt with the clear distance between holes.

[math] l_{c2} = s_{r} – d_{h} = 75\ \text{mm} – 22\ \text{mm} = 53\ \text{mm} [math]

[math] \phi R_{n} = \phi\, \min\left(1.2\, l_{c2},\, 2.4\, d_{b}\right) t_{fs} F_{us} N_{V} [math]

[math] \phi R_{n} = (0.75) \times \min\left(1.2 \times 53\ \text{mm},\, 2.4 \times 20\ \text{mm}\right) \times (18.034\ \text{mm}) \times (450\ \text{MPa}) \times (6) [math]

[math] \phi R_{n} = 1752.9\ \text{kN} [math]

DCR = 142 kN / 1752.9 kN = 0.081 < 1.0, OK

Step 10: Effective strength of the bolt group (AISC 360-16 J3.6 Commentary)

Each bolt delivers the least of its shear strength, its bearing or tear-out strength on the angle, and its bearing strength on the column flange. The group strength is the sum of those per-bolt values.

[math] \phi r_{v} = \frac{\phi R_{n}}{N_{V}} = \frac{525.9\ \text{kN}}{6} = 87.65\ \text{kN} [math]

[math] \phi r_{n1e} = (0.75) \min\left(34.8,\, 48\right)(7.9502)(400) = 83\ \text{kN} \qquad \phi r_{n1i} = (0.75) \min\left(63.6,\, 48\right)(7.9502)(400) = 114.48\ \text{kN} [math]

[math] \phi r_{n2} = (0.75) \min\left(63.6,\, 48\right)(18.034)(450) = 292.15\ \text{kN} [math]

Bolts are numbered from the top of the line, so bolt 1 is the edge bolt on the angle:

BoltBolt shear (kN)Bearing / tear-out on the angle (kN)Bearing on the column flange (kN)Effective strength (kN)
187.6583.00292.1583.00
2, 387.65114.48292.1587.65

[math] \sum \phi r_{eff} = (1) \times (83\ \text{kN}) + (2) \times (87.65\ \text{kN}) = 258.3\ \text{kN} [math]

[math] \phi R_{n,eff} = \frac{N_{V}}{n_{r}} \sum \phi r_{eff} = \frac{6}{3} \times (258.3\ \text{kN}) = 516.6\ \text{kN} [math]

DCR = 142 kN / 516.6 kN = 0.275 < 1.0, OK

Tear-out at the edge bolt, 83 kN, is lower than the bolt’s 87.65 kN shear strength, which is why this check is a little lower than the bolt shear check in Step 7.

Step 11: Block shear of the angles at the support side (AISC 360-16 J4.3)

A block of each outstanding leg can tear out: shear down the bolt line and tension across to the toe of the leg. The tension area uses the slot length along the member, [mathin] d_{h} = 26\ \text{mm} [mathin], and each hole adds 2 mm for damage (B4.3). The areas include both angles, [mathin] 2t_{a} = 15.9\ \text{mm} [mathin].

[math] A_{nt} = 2t_{a} \left[ L_{eh,a} – 0.5\left( d_{h} + 2\ \text{mm} \right) \right] = (15.9) \times \left[ 37.59 – 0.5 (28) \right] = 375.09\ \text{mm}^{2} [math]

[math] A_{gv} = 2t_{a} \left[ L_{ev,a} + (n_{r}-1) s_{r} \right] = (15.9) \times \left[ 40 + (2)(75) \right] = 3021.1\ \text{mm}^{2} [math]

[math] A_{nv} = 2t_{a} \left[ d_{a} – L_{ev,a} – (n_{r}-0.5)\left( d_{h} + 2\ \text{mm} \right) \right] = (15.9) \times \left[ 230 – 40 – (2.5)(24) \right] = 2067.1\ \text{mm}^{2} [math]

[math] \phi R_{n} = \phi\, \left[ \min\left( 0.6 F_{ua} A_{nv},\; 0.6 F_{ya} A_{gv} \right) + U_{bs} F_{ua} A_{nt} \right] [math]

[math] \phi R_{n} = (0.75) \times \left[ \min\left( 0.6 \times 400 \times 2067.1,\; 0.6 \times 250 \times 3021.1 \right) + 1 \times 400 \times 375.09 \right] [math]

[math] \phi R_{n} = 452.4\ \text{kN} [math]

DCR = 142 kN / 452.4 kN = 0.314 < 1.0, OK

with [mathin] U_{bs} = 1 [mathin]. Shear yielding on the gross area is the lower branch, so it sets the strength.

Step 12: Shear yielding and shear rupture of the angles at the support side (AISC 360-16 J4.2)

Shear yielding is the same as on the beam side. Shear rupture now uses the net area through the bolt holes.

[math] \phi R_{n,sy} = (1.00) \times 0.6 \times (250\ \text{MPa}) \times (3657.1\ \text{mm}^{2}) = 548.56\ \text{kN} [math]

[math] A_{nv} = 2t_{a} \left[ d_{a} – n_{r}\left( d_{h} + 2\ \text{mm} \right) \right] = (15.9\ \text{mm}) \times \left[ 230\ \text{mm} – 3 \times (24\ \text{mm}) \right] = 2512.3\ \text{mm}^{2} [math]

[math] \phi R_{n,sr} = (0.75) \times 0.6 \times (400\ \text{MPa}) \times (2512.3\ \text{mm}^{2}) = 452.21\ \text{kN} [math]

[math] \phi R_{n} = \min\left( 548.56\ \text{kN},\, 452.21\ \text{kN} \right) = 452.21\ \text{kN} [math]

DCR = 142 kN / 452.21 kN = 0.314 < 1.0, OK

Step 13: Flexure of the angles at the support side, double coped procedure (AISC 360-16 F11.2)

On the support side the unbraced length is the distance from the bolt line to the face of the beam web, half of the gage less the web thickness: [mathin] L_{b} = (135.64 – 7.62)/2 = 64.01\ \text{mm} [mathin].

Range check

[math] \frac{L_{b} d}{t^{2}} = \frac{(64.01\ \text{mm})(230\ \text{mm})}{(7.9502\ \text{mm})^{2}} = 232.93 [math]

[math] \frac{0.08 E}{F_{y}} = \frac{0.08 \times 200000\ \text{MPa}}{250\ \text{MPa}} = 64 \lt 232.93 \le \frac{1.9 E}{F_{y}} = \frac{1.9 \times 200000\ \text{MPa}}{250\ \text{MPa}} = 1520 [math]

The ratio is between the two limits, so Eq. F11-2 applies with the buckling modification factor.

Section moduli of one angle leg

[math] Z = \frac{t_{a} d_{a}^{2}}{4} = \frac{(7.9502\ \text{mm})(230\ \text{mm})^{2}}{4} = 105140\ \text{mm}^{3} \qquad S = \frac{t_{a} d_{a}^{2}}{6} = \frac{(7.9502\ \text{mm})(230\ \text{mm})^{2}}{6} = 70094\ \text{mm}^{3} [math]

Lateral-torsional buckling modification factor (AISC Manual Eq. 9-15)

The angles are not coped, so [mathin] d_{ct} = 0 [mathin]:

[math] C_{b} = \left[ 3 + \ln\left( \frac{64.01\ \text{mm}}{230\ \text{mm}} \right) \right] \times \left( 1 – \frac{0}{230} \right) \ge 1.84 \;\Rightarrow\; C_{b} = 1.84 [math]

Flexural strength (Eq. F11-2)

[math] \phi M_{n} = \phi \min\left\{ C_{b} \left[ 1.52 – 0.274 \left( \frac{L_{b} d}{t^{2}} \right) \frac{F_{ya}}{E} \right] F_{ya} S,\; F_{ya} Z \right\} 2 [math]

[math] \phi M_{n} = (0.9) \times \min\left\{ (1.84) \left[ 1.52 – 0.274 \times (232.93) \times \frac{250}{200000} \right] (250)(70094),\; (250)(105140) \right\} \times 2 = 47.314\ \text{kN-m} [math]

The plastic moment governs, so the angles do not buckle sideways at this length.

Equivalent shear capacity

[math] \phi V_{n} = \frac{\phi M_{n}}{L_{b}} = \frac{47.314\ \text{kN-m}}{64.01\ \text{mm}} = 739.16\ \text{kN} [math]

DCR = 142 kN / 739.16 kN = 0.192 < 1.0, OK

Step 14: Shear and moment interaction of the angles at the support side (AISC Manual Eq. 10-5)

The angles carry shear and bending together at the same section. AISC Manual Eq. 10-5 combines them with the shear yielding strength and the flexural strength:

[math] M_{r} = V_{u} L_{b} = (142\ \text{kN}) \times (64.01\ \text{mm}) = 9.0894\ \text{kN-m} [math]

[math] I_{nt} = \left( \frac{V_{u}}{\phi R_{n,sy}} \right)^{2} + \left( \frac{M_{r}}{\phi M_{n}} \right)^{2} = \left( \frac{142\ \text{kN}}{548.56\ \text{kN}} \right)^{2} + \left( \frac{9.0894\ \text{kN-m}}{47.314\ \text{kN-m}} \right)^{2} = 0.104 [math]

DCR = 0.104 < 1.0, OK

Summary of design checks

Design checkDemandDesign strengthDCRResult
1. Detailing limits at the beam side196.85 mm230 mm0.856PASS
2. Weld group at the beam142 kN545.07 kN0.261PASS
3. Angle shear at the beam side142 kN548.56 kN0.259PASS
4. Angle flexure at the beam side142 kN3942.8 kN0.036PASS
5. Shear and moment interaction, beam side0.06831.0000.068PASS
6. Detailing limits at the support side113.025 mm135.64 mm0.833PASS
7. Bolt group shear142 kN525.90 kN0.270PASS
8. Bearing and tear-out on the angles142 kN623.93 kN0.228PASS
9. Bearing and tear-out on the column flange142 kN1752.9 kN0.081PASS
10. Effective strength of the bolt group142 kN516.60 kN0.275PASS
11. Block shear of the angles142 kN452.40 kN0.314PASS
**12. Angle shear at the support side****142 kN****452.21 kN****0.314****PASS**
13. Angle flexure at the support side142 kN739.16 kN0.192PASS
14. Shear and moment interaction, support side0.1041.0000.104PASS

The connection passes every check. Shear rupture of the angles through the bolt holes governs the strength checks at 0.314, a hair above block shear (also 0.314 to three places: 452.21 kN against 452.40 kN). The effective bolt group strength (0.275) and bolt shear (0.270) come next. The minimum connection depth (0.856) and the minimum gage at the support (0.833) are the highest ratios on the page.

What to change if a check fails

  • Weld at the beam: a longer angle or longer returns raise C and the weld length. A larger weld only helps up to the base metal limit set by the beam web, and it must stay within the angle-thickness limit in Step 1.
  • Weld size per angle thickness: use a thicker angle, or a smaller weld.
  • Bolt shear or effective strength: add a bolt row or use a larger bolt.
  • Tear-out at the edge bolt: increase the vertical edge distance on the angles.
  • Block shear or shear rupture of the angles: make the angles longer with another bolt row, or use a thicker angle.
  • Angle flexure at the support: a smaller gage shortens the lever arm, but it must stay above both minimum gages in Step 6.
  • Minimum gage at the support: widen the gage, which may need longer outstanding legs to keep the edge distance.

Auto Design is available for the double angle connection to a column flange. It changes the connection’s design variables until every check passes, and keeps your members and loads as entered. See the Auto Design page for the preferences it works to.

Frequently asked questions

How does this metric example differ from the LRFD version?

The method is the same AISC 360-16 LRFD design with the same resistance factors. The inputs are in millimetres, kN and MPa, the bolts are M20 and the angles and members use the metric ASTM grades A36M and A992M, so the edge distance limits come from Tables J3.4M and J3.5M and the hole damage allowance is 2 mm instead of 1/16 in. The LRFD version also bolts the angles to the beam web, so it has bolt checks on the beam side where this example has a weld check.

Why weld the angles to the beam instead of bolting them?

Shop welding the angles to the beam leaves no holes in the beam web, and only the column-side bolts are installed on site. The trade-off is that the weld has to carry the reaction with an eccentricity, and the beam web thickness limits how much of the weld counts.

Why are the column bolts in single shear?

Each bolt at the column passes through one angle leg and the column flange, which is one shear plane. On a bolted beam side, the bolts pass through both angles and the beam web, which gives two shear planes.

Why does the thin beam web limit the weld?

The weld transfers shear into the beam web, and the web has a weld on each face. AISC Manual Eq. 9-2 limits each weld to what half the web thickness can carry in shear rupture, so a thin web caps the useful weld size.

Why is a double coped beam procedure used to check an angle?

A leg of an angle loaded in its own plane behaves like a deep, thin rectangle in bending, which is what a beam web with both flanges coped looks like. The AISC Manual uses the same F11 equations, with the buckling factor of Manual Eq. 9-15, for both.

Does this example follow the AISC 15th edition or the AISC 16th edition Manual?

It follows AISC 360-16 and the AISC Manual 15th Edition, which is written around that Specification. The AISC 16th Edition Manual pairs with the later 360-22 Specification. The limit states for a double angle connection are the same in both, but clause and page references move, so check them against the edition your project uses.

Design a double angle connection for free

Every number on this page comes from one solve. Pick the double angle configuration, choose AISC 360-16 LRFD with metric units, enter your beam, support, angles, weld, bolts and reaction, and see each of these checks in your browser. There is nothing to install.

The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every capacity and DCR, for AISC 360-22 and AISC 360-16 (LRFD and ASD) and AS 4100:2020. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.

References

  • AISC 360-16, Specification for Structural Steel Buildings: B3.4, B4.3, F11.1 (Eq. F11-1), F11.2 (Eq. F11-2), J2.2b, J3.3, J3.4 (Table J3.4M), J3.5 (Table J3.5M), J3.6 (Eq. J3-1) and Commentary, J3.10 (Eq. J3-6a, J3-6c), J4.2 (Eq. J4-3, J4-4), J4.3, J5.2(a).
  • AISC Steel Construction Manual, 15th Edition: Part 8, pages 8-9 to 8-12, Eq. 8-3 and 8-21, Table 8-3; Part 9, Eq. 9-2 and 9-15; Part 10, Eq. 10-5.
  • Double angle connection design, LRFD version
  • Design of steel connections using AISC 360-16
  • Bolts and welds in SkyCiv Connection Design
Harold Munalem, Product Manager for SkyCiv Connection Design

Harold Munalem
Product Manager, Connection Design
10+ years in steel connection design