This page explains how SkyCiv Foundation designs a combined footing to Eurocode 2 (EN 1992-1-1) and Eurocode 7 (EN 1997-1): soil bearing, one-way shear, punching shear and flexure, with the equations used and the results shown in the software and the calculation report, followed by the other design checks (uplift, overturning, sliding, anchorage and detailing). Flexure is described with the default Strip average method, and the Peak wood-armer method is summarized for comparison.
Overview of Combined Footing Design (EN 1992 and EN 1997)
When two columns are closely spaced, separate isolated footings would overlap or be impractical, and the soil beneath them would share parts of their zones of influence. A combined footing solves this by supporting two columns on one continuous base. It is also used when a column is too close to a property line for an isolated footing.
SkyCiv Foundation meshes the footing into plate elements supported on the soil (modeled with the subgrade modulus) and analyzes it with finite element analysis (FEA). The soil pressures, shears and moments used in the design checks below come from these FEA results. To design to Eurocode, select Eurocode as the Design Code and EC-2, EC-7 (2004) as the Version when you start a new file, then pick Combined Footing. Eurocode designs are in metric units.

The example shown on this page is a 3000 × 1500 × 500 mm combined footing with two 300 × 300 mm columns placed 250 mm from the ends of the footing (X-edge Distance), P16 bars at 300 mm in both directions at the top and bottom, and a 75 mm cover. The concrete is C20/25 and the reinforcement has a yield strength of 500 MPa, with the default partial factors \( \gamma_{C} \) = 1.5 and \( \gamma_{S} \) = 1.15 (Design Factors tab of the Loads). Column 1 carries a permanent load (G) of 200 kN and a variable load (Ql) of 100 kN, and Column 2 a permanent load of 250 kN and a variable load of 120 kN. The x-direction is the direction joining the two columns.
Design Settings for Eurocode
The methods used for the checks are set in Edit Design Settings (Details tab). For a combined footing designed to Eurocode, the dialog holds:
- Include soil and footing weight: includes the self-weight of the footing and of the soil above it in the serviceability (SLS, on by default) and ultimate (ULS, off by default) load combinations.
- Punching Shear β Calculation Method: how the factor β of the punching shear demand is calculated. Fully plastic shear distribution (default) calculates β from the moments transferred to the footing, and Simplified uses the recommended values of EN 1992 Figure 6.21N. See Two-way Shear (Punching Shear).
- Moment Demand Calculation: Strip average method (default) or Peak wood-armer method. See Flexure.
- Development Length Checks: the Perform dowel bars check, Perform top bars check and Perform bottom bars check switches (all enabled by default) turn the anchorage checks on or off.
For Eurocode, the punching shear demand is always calculated with the mesh-based method, and there is no load transfer check.

Combined Footing Design Checks to EN 1992 and EN 1997
Dimension Requirements and Soil Bearing
The footing is sized with a safe (allowable) bearing pressure under the serviceability limit state, before the structural design at the ultimate limit state. The characteristic actions, such as permanent (G), variable (Ql), wind (Qw), snow (Qs), temperature (Qt) and seismic (Qe) loads, are combined in the serviceability load combinations. The governing combination is the design load, and the base area is proportioned so that the allowable soil pressure is not exceeded:
[math] q_{a} = \frac{P1_{n} + P2_{n}}{A} \quad \text{(Eq. 1)} [math]
qa = Allowable soil pressure
P1n, P2n = Unfactored loads at Column 1 (left) and Column 2 (right)
A = Foundation area
Solving Equation 1 for the area gives a first estimate of the footing dimensions, which should be chosen so that the resultant of the loads passes close to the centroid of the base:
[math] A = \frac{P1_{n} + P2_{n}}{q_{a}} \quad \text{(Eq. 1a)} [math]
SkyCiv Foundation does not size the footing from Equation 1a: the dimensions are inputs (Geometry tab), and the software checks them. The Soil Bearing ratio is the maximum soil pressure from the FEA results of the serviceability load combinations (envelope), which includes the effect of the column moments and of the eccentricity of the loads, divided by the Gross Allowable Soil Bearing Capacity entered in the Soil tab (500 kPa by default):
[math] \text{Utility Ratio} = \frac{q_{sls,max}}{q_{a}} \quad \text{(Eq. 2)} [math]
In the example, the maximum service soil pressure is 223.6 kPa, under Column 2, which carries the larger load, and the Soil Bearing ratio is 0.447. The soil pressure contour and the ratio of every check are shown in the Results tab:

One-way Shear
The one-way shear limit state, also known as flexural shear, treats the footing like a wide beam that may fail in shear along a critical section across the width of the footing, located at a distance "d" from the face of a column.
The One-way Shear Demand or \( V_{Ed} \) is taken from the strip average shear diagrams of the FEA (ultimate load combinations): the shear forces of the plate elements are summed across the width of the footing, and the diagram is read at the critical sections, located at the effective depth of the bottom bars in that direction from each column face (or at the edge of the footing when that distance falls outside it). The largest absolute shear at these sections is the demand.
- Along x (the direction joining the columns), one diagram covers the whole footing, with the critical sections on both sides of both columns.
- Along z, each column has its own diagram, through that column.
The diagrams can be viewed in the Results tab by opening Diagrams and choosing One-way Shear in the Diagram list. In the example, the critical sections along x are 417 mm (the effective depth of the bottom x-bars) from the inner faces of the columns, and the demand is 167.26 kN, next to Column 2:

Figure 1. Critical sections and shear diagram of one-way shear along x (Results, Diagrams button)
The One-way Shear Capacity or \( V_{Rd,c} \) is the design shear resistance of a member without shear reinforcement (EN 1992-1-1, 6.2.2), calculated with Equation 3, with the minimum of Equation 4:
[math] V_{Rd,c} = \left[ C_{Rd,c} \, k \left( 100 \, \rho_{1} \, f_{ck} \right)^{1/3} \right] b_{w} \, d \quad \text{(Eq. 3, EN 1992-1-1 Eq. 6.2a)} [math]
[math] V_{Rd,c,min} = \left( 0.035 \, k^{3/2} \, f_{ck}^{1/2} \right) b_{w} \, d \quad \text{(Eq. 4, EN 1992-1-1 Eq. 6.2b)} [math]
[math] k = 1 + \sqrt{\frac{200}{d}} \leq 2.0 \qquad \rho_{1} = \frac{A_{sl}}{b_{w} \, d} \leq 0.02 [math]
CRd,c = 0.18/γC, taken as 0.12
fck = Characteristic concrete cylinder strength (MPa)
Asl = Area of the bottom bars in the direction checked
bw = Width resisting the shear (mm)
d = Effective depth of the bottom bars in the direction checked (mm)
The capacity is the larger of Equations 3 and 4. Along x, \( b_{w} \) is the full width of the footing (its dimension along z). Along z, the footing is divided into two design strips at the midpoint between the two columns, and \( b_{w} \) is the strip width (1500 mm for both strips in the example).
The calculation report shows the shear diagram of each direction, followed by the demand, the capacity and the ratio. Along x in the example, \( V_{Rd,c} \) = 199.24 kN and \( V_{Rd,c,min} \) = 215.59 kN, so the capacity is 215.59 kN and the ratio is 167.26/215.59 = 0.776:

Shear Demand and Shear Capacity must meet the ultimate limit state requirement of EN 1990:
[math] E_{d} \leq R_{d} \quad \text{(Eq. 5, EN 1990 6.4.2)} [math]
SkyCiv Foundation, in compliance with Equation 5, calculates the one-way shear utility ratio by taking Shear Demand over Shear Capacity, along x and for each column along z. The largest ratio is listed as One-Way Shear in the Design Checks Summary.
[math] \text{Utility Ratio} = \frac{V_{Ed}}{V_{Rd,c}} \quad \text{(Eq. 6)} [math]
Two-way Shear (Punching Shear)
The two-way shear limit state, also known as punching shear, is checked around each column on control perimeters at a distance \( a \) from the column faces. For column bases, EN 1992-1-1, 6.4.4(2) requires control perimeters within 2d of the column face to be checked, so SkyCiv Foundation checks several of them: at 2d, 1.5d, 1d, 0.75d, 0.5d and 0.25d, and at the distance where the perimeter reaches a footing edge. A perimeter that cannot be drawn inside the footing is not checked (it is shown with a dash in the report). The perimeters can be viewed in the Results tab by opening Diagrams and choosing Punching Shear in the Diagram list:

Figure 2. Control perimeters of punching shear (Results, Diagrams button)
The effective depth \( d \) is the average of the effective depths of the bottom bars in both directions (409 mm in the example). When a column face is closer to a footing edge than \( a \), the perimeter on that side runs to the footing edge, and the column is treated as an edge or corner column at that distance (EN 1992-1-1, 6.4.2). A round column is taken as an equivalent square column with sides equal to its diameter. The length of the control perimeter is, for an interior column:
[math] u = 2 \left( c_{x} + c_{z} \right) + 2 \pi a \quad \text{(Eq. 7)} [math]
Punching Shear Demand with the Mesh-based Method
The Punching Shear Demand is calculated with the mesh-based method, from the finite element analysis of the footing. The upward force from the soil pressure inside the control perimeter, \( F_{q} \) (\( \Delta V_{Ed} \) in EN 1992), is the sum of the forces of the mesh elements in that area (the average pressure on each element times its area inside the perimeter), and it is subtracted from the factored column load (EN 1992-1-1, 6.4.4(2)):
[math] V_{Ed,red} = V_{Ed} – F_{q} \quad \text{(Eq. 8, EN 1992-1-1 Eq. 6.48)} [math]
[math] v_{Ed} = \beta \, \frac{V_{Ed,red}}{u \, d} \quad \text{(Eq. 9, EN 1992-1-1 Eq. 6.51)} [math]
VEd = Factored column load (ultimate load combinations)
Fq = Resultant of the factored soil pressure inside the control perimeter, summed over the FEA mesh elements
u = Length of the control perimeter at the distance a
β = Factor for the effect of the moments transferred to the footing
The factor β is set by the Punching Shear β Calculation Method of the design settings:
- Fully plastic shear distribution (default): β is calculated from the moments transferred from the column to the footing (EN 1992-1-1, 6.4.3), for example \( \beta = 1 + k \, \frac{M_{Ed}}{V_{Ed,red}} \, \frac{u}{W} \) (Eq. 6.39 and 6.51), with \( k \) from Table 6.1 and \( W \) the plastic modulus of the control perimeter. The moment includes the column moment plus the column shear times the column height and footing thickness. For biaxial moments on an interior column, Eq. 6.43 is used, and for edge and corner columns the moment also includes the eccentricity of the column load from the centroid of the control perimeter.
- Simplified: β = 1.15 for an interior column, 1.4 for an edge column and 1.5 for a corner column (EN 1992-1-1, Figure 6.21N).
Punching Shear Capacity
The Punching Shear Capacity \( v_{Rd} \) at the distance \( a \) is increased by \( 2d/a \), as allowed for column bases (EN 1992-1-1, 6.4.4(2)):
[math] v_{Rd} = C_{Rd,c} \, k \left( 100 \, \rho_{l} \, f_{ck} \right)^{1/3} \frac{2d}{a} \geq v_{min} \, \frac{2d}{a} \quad \text{(Eq. 10, EN 1992-1-1 Eq. 6.50)} [math]
[math] \rho_{l} = \sqrt{\rho_{l,x} \, \rho_{l,z}} \qquad v_{min} = 0.035 \, k^{3/2} \, f_{ck}^{1/2} [math]
ρl,x, ρl,z = Ratios of the bottom bars in the x and z directions
k = 1 + √(200/d) ≤ 2.0, with the average effective depth d
Other variables as defined for one-way shear
The calculation report shows, for each column and each distance, the plan of the control perimeter, \( F_{q} \), β, \( v_{Ed} \) and the capacity, followed by a summary table. For Column 2 of the example, the governing perimeter is at 1.47d (600 mm from the column face, where the perimeter reaches the long edges of the footing):

Shear Demand and Shear Capacity must meet the following requirement (EN 1992-1-1, 6.4.3(2)):
[math] v_{Ed} \leq v_{Rd} \quad \text{(Eq. 11)} [math]
SkyCiv Foundation, in compliance with Equation 11, calculates the punching shear utility ratio at each distance by taking Shear Demand over Shear Capacity, both as stresses. The largest ratio of the two columns is listed as Punching Shear in the Design Checks Summary (0.670 in the example, from Column 2).
[math] \text{Utility Ratio} = \frac{v_{Ed}}{v_{Rd}} \quad \text{(Eq. 12)} [math]
Flexure
SkyCiv Foundation checks the top and bottom reinforcement in both directions against the moments of the whole footing from the FEA, rather than at a single critical section. In a combined footing, the top bars along x resist the hogging moment between the columns, and the bottom bars resist the sagging moments under the columns and in the transverse direction.
Moment Demand with the Strip Average Method
With the Strip average method (the default Moment Demand Calculation), the footing is treated like a wide beam in each direction: the Wood-Armer moments of the plate elements are summed across the width of the footing, which gives the total moment carried by that width at each section. This is done for the top and bottom layers, along x and along z, under the ultimate load combinations (envelope).
- Along x, the strip covers the full width of the footing, and one moment diagram covers both columns.
- Along z, the footing is divided into two design strips at the midpoint between the column centres, and each column has its own diagram.
- Bottom layer: \( M_{Ed} \) is the largest strip moment at the column faces.
- Top layer: \( M_{Ed} \) is the largest hogging (negative) strip moment anywhere along the strip.
The moment diagrams can be viewed in the Results tab by opening Diagrams, choosing Moment in the Diagram list, and picking the Layer and Direction. In the example, the top layer along x has a maximum hogging moment of 163.05 kN-m, midway between the columns:

Figure 3. Strip average moment diagram, top layer along x (Results, Diagrams button)
The calculation report shows the same diagram for each layer and direction, with a table of the maximum moment, its coordinates and the governing load combination, followed by the utility ratio:

Peak Wood-Armer Method
With the Peak wood-armer method, \( M_{Ed} \) is instead the maximum Wood-Armer moment per unit width found anywhere over the footing, for the top and bottom layers in both directions, and the capacity is calculated for a 1000 mm width. Because it uses the peak moment rather than the moment spread over the width, it is usually more conservative. The Wood-Armer moments can be viewed in the Results tab with the Wood Armer button.
Flexural Capacity
With the strip average method, the Flexural Capacity \( M_{Rd} \) is calculated for the width of the strip, with the bars of the layer across that width (along z, the share of the bars in each strip, in proportion to its width). The section is first compared with the balanced moment of the concrete:
[math] M_{bal} = \frac{0.25092}{\gamma_{C}} \, f_{ck} \, b \, d^{2} [math]
When \( M_{Ed} \leq M_{bal} \), the section is singly reinforced, with a rectangular stress block for concrete classes up to C50/60 (\( \varepsilon_{cu2} \) = 0.0035):
[math] s = \frac{\frac{f_{yk}}{\gamma_{S}} A_{s}}{\frac{0.85}{\gamma_{C}} f_{ck} \, b} \qquad x = \frac{s}{0.8} [math]
[math] M_{Rd} = \frac{f_{yk}}{\gamma_{S}} \, A_{s} \left( d – \frac{s}{2} \right) \quad \text{(Eq. 13)} [math]
When \( M_{Ed} > M_{bal} \), the section is checked as doubly reinforced, with the bars of the other layer as compression reinforcement:
[math] M_{Rd} = \frac{0.85}{\gamma_{C}} f_{ck} \, b \, s \left( d – \frac{s}{2} \right) + \frac{f_{yk}}{\gamma_{S}} \, A_{s2} \left( d – d_{2} \right) \quad \text{(Eq. 14)} [math]
γC, γS = Partial factors for concrete and reinforcing steel (persistent and transient)
fyk = Characteristic yield strength of the reinforcement (MPa)
As = Area of the tension bars of the layer across the strip width (mm2)
As2, d2 = Area and depth of the compression bars (mm2, mm)
b = Strip width: the full width of the footing along x, the strip of each column along z (mm)
d = Effective depth of the tension bars (mm)
s, x = Depth of the stress block and of the neutral axis (mm)
In the example, the 6 top bars along x (1206.4 mm²) with d = 417 mm give s = 30.85 mm and \( M_{Rd} \) = 210.63 kN-m, and the top layer ratio along x is 163.05/210.63 = 0.774.
The provided reinforcement of each layer, in each direction, is also compared with the minimum area of EN 1992-1-1, 9.2.1.1:
[math] A_{s,min} = \max \left( 0.26 \, \frac{f_{ctm}}{f_{yk}} \, b \, d, \; 0.0013 \, b \, d \right) \qquad f_{ctm} = 0.30 \, f_{ck}^{2/3} \quad \text{(Eq. 15)} [math]
Moment Demand and Moment Capacity must meet the ultimate limit state requirement of EN 1990:
[math] M_{Ed} \leq M_{Rd} \quad \text{(Eq. 16, EN 1990 6.4.2)} [math]
SkyCiv Foundation, in compliance with Equation 16, calculates the flexural utility ratio by taking Flexural Demand over Flexural Capacity, for the top and bottom layers along x and for each strip along z. The Flexure ratio in the Design Checks Summary is the largest of the top, bottom and minimum reinforcement ratios (0.774 in the example).
[math] \text{Utility Ratio} = \frac{M_{Ed}}{M_{Rd}} \quad \text{(Eq. 17)} [math]
Want to try SkyCiv’s Foundation Design software? Our free tool allows users to perform load-carrying calculations without any download or installation!
Other Design Checks
Besides the checks above, the calculation report of a combined footing designed to Eurocode includes the stability checks, the anchorage of the bars and a detailing check. Each one gives a utilization ratio in the Design Checks Summary of the Results tab, and the footing fails when a ratio is greater than 1.0. A check that does not apply to the loads (for example sliding without horizontal loads) is shown with a dash.
- Uplift: compares the upward forces with the forces holding the footing down (axial loads only: the column loads, the self-weights of the columns, footing and soil, and the buoyant force).
- Overturning: sums the moments of all the forces about the edges of the footing in each direction, and compares the smallest factor of safety with the Overturning factor of safety in the Design Factors tab of the Loads (2.0 by default).
- Sliding: divides the horizontal resisting forces (friction at the base, passive soil pressure and cohesion) by the horizontal force in each direction, and compares the factor of safety with the Sliding factor of safety in the Design Factors tab (1.5 by default).
- Development Length: checks the anchorage length of the column dowel bars (EN 1992-1-1, 8.4) within the footing thickness, and the anchorage of the top and bottom bars of the footing beyond the column faces, with the bar force of EN 1992-1-1, 9.8.2.2. The checks follow the Development Length Checks switches of the design settings (0.336 in the example).
- Detailing: verifies that the footing thickness can hold the hooked ends of the top and bottom bars, with their bend and the top and bottom covers.
Free Concrete Footing Calculator
Try SkyCiv Free Concrete Footing Calculator to design foundations for footings, combined footings, concrete piles, concrete pads, and more.
SkyCiv Foundation Design Software
Make the most of SkyCiv Foundation Design Software by signing up for Professional Account or try it out for free!
References
- Eurocode 2: Design of concrete structures – Part 1-1: General rules and rules for buildings (EN 1992-1-1:2004). European Committee for Standardization, 2004.
- Eurocode 7: Geotechnical design – Part 1: General rules (EN 1997-1:2004). European Committee for Standardization, 2004.
- Eurocode: Basis of structural design (EN 1990:2002). European Committee for Standardization, 2002.
- Mosley, Bungey, and Hulse. Reinforced Concrete Design to Eurocode 2 (Seventh Edition), 2012.