Isolated Footing Design Walkthrough with ACI 318-19

This page walks through the isolated footing design checks that SkyCiv Foundation performs to ACI 318-19: soil bearing, one-way shear, punching shear and flexure, with the equations used, plus the stability checks (uplift, overturning and sliding). Flexure is described with the default Strip average method, and the Peak wood-armer method is summarized for comparison.

The foundation is an essential building system that transfers column and wall forces to the supporting soil. The engineer might opt for a shallow or deep foundation system based on the soil characteristics and building loads. SkyCiv Foundation designs isolated footings (pad footings) to the American code ACI 318-19. To use it, select American Concrete Institute as the Design Code and ACI 318 (2019) as the Version when you start a new file, then pick Pad Footing.

SkyCiv Foundation Geometry tab with 3D model of an ACI 318 (2019) isolated footing, 1500×1500×500 mm, #5 bars, dowels

The example shown on this page is the default pad footing (1500 × 1500 × 500 mm footing, 300 × 300 mm column, #5 bars at 150 mm each way) with a dead load of 400 kN and a live load of 250 kN on the column.

Design Settings for ACI 318-19

The methods used for the checks are set in Edit Design Settings (Details tab). For ACI 318-19, the Moment Demand Calculation offers the Strip average method (default) and the Peak wood-armer method. The settings also hold the Perform One-Way Shear Check toggle and the Punching Shear Edge Factor (0.5 by default).

Design Settings dialog for ACI 318-19 in SkyCiv Foundation, with Moment Demand Calculation set to Strip average method.

A Step-by-Step Guide to Designing an Isolated Footing

Dimension Requirements

To determine the dimensions of an isolated footing, service or unfactored loads, such as Dead (D), Live (L), Wind (W), Seismic (E), etc. are combined using the load combinations of ACI 318-19 (Table 5.3.1). Whichever load combination governs is considered the design load, and is compared to the allowable soil pressure as shown in Equation 1, as required by Section 13.3.1.1 of ACI 318-19.

[math] q_{a} = \frac{P_{n}}{A} \quad \text{(Eq. 1)} [math]

qa = Allowable soil pressure
Pn = Unfactored design load
A = Foundation area

The footing dimensions can be initially estimated by solving the foundation area (A) using Equation 1.

[math] A = \frac{P_{n}}{q_{a}} \quad \text{(Eq. 1a)} [math]

In SkyCiv Foundation, the footing dimensions are inputs (Geometry tab). The software checks them with the soil pressures from the finite element analysis, as described in Soil Pressure.

One-way Shear

The one-way shear limit state, also known as beam shear, recognizes that the footing may fail in shear similar to a wide beam along a critical section located at a distance “d” from the face of the column (Figure 1). SkyCiv Foundation checks it in both directions (along x and along z). It can be turned off with Perform One-Way Shear Check in the design settings (on by default).

One-way shear diagram in SkyCiv Foundation: footing plan with critical sections 417 mm from column, strip shear ±107.41 kN

Figure 1. One-way shear diagram (Results, Diagrams button)

The One-way Shear Demand or \( V_{u} \) is taken from the strip shear diagram of the footing: the shear forces of the finite element analysis are summed across the full width of the footing, along a strip through the column, and read at the two critical sections. The larger absolute value of the ultimate load combinations is used, in each direction.

The One-way Shear Capacity or \( \phi V_{c} \) is calculated with Equation 2 (Table 22.5.5.1(c), for members without shear reinforcement), with the full width of the footing perpendicular to the direction checked. The size effect factor \( \lambda_{s} \) is neglected for footings, as permitted by Section 13.2.6.2.

[math] \phi V_{c} = \phi_{\text{shear}} \times 8 \lambda \left( \rho_{w} \right)^{1/3} \sqrt{f’_{c}} \times b_{w} \times d \quad \text{(Eq. 2, Table 22.5.5.1(c), Imperial)} [math]

or

[math] \phi V_{c} = \phi_{\text{shear}} \times 0.66 \lambda \left( \rho_{w} \right)^{1/3} \sqrt{f’_{c}} \times b_{w} \times d \quad \text{(Eq. 2, Table 22.5.5.1(c), Metric)} [math]

[math] \rho_{w} = \frac{n \times A_{b}}{b_{w} \times d} [math]

ϕshear = Shear strength reduction factor, 0.75 (Table 21.2.1)
λ = Modification factor for lightweight concrete
ρw = Ratio of the bottom bars in the direction checked
n, Ab = Number and area of these bars
f’c = Specified concrete strength, (psi, MPa)
bw = Width of the footing perpendicular to the direction checked, (in, mm)
d = Effective depth of the bottom bars in the direction checked, (in, mm)

Shear Demand and Shear Capacity must meet the following equation to meet the design requirements of ACI 318-19:

[math] V_{u} \leq \phi V_{c} \quad \text{(Eq. 3, Section 7.5.1.1(b))} [math]

SkyCiv Foundation, in compliance with Equation 3, calculates the one-way shear utility ratio (Equation 4) by taking Shear Demand over Shear Capacity. The larger ratio of the two directions is listed as One-Way Shear in the Design Checks Summary.

[math] \text{Utility Ratio} = \frac{\text{Shear Demand}}{\text{Shear Capacity}} \quad \text{(Eq. 4)} [math]

Get started

Want to try it for yourself?

Try SkyCiv today for free!

Sign Up Free

Two-way Shear (Punching Shear)

The two-way shear limit state, also known as punching shear, has its critical section at a distance “d/2” from the faces of the column, around the perimeter of the column (Figure 2). Its length is the critical perimeter \( b_{o} \).

Punching Shear diagram in SkyCiv Foundation Diagrams window: 1500 square footing, dashed critical perimeter at 0.5d around column

Figure 2. Critical perimeter of two-way shear (Results, Diagrams button)

When a column face is closer to a footing edge than the Punching Shear Edge Factor times d (design settings, 0.5 by default), the perimeter on that side extends to the footing edge and is not counted in \( b_{o} \). The column is then classified as an interior, edge or corner column, which sets \( \alpha_{s} \) = 40, 30 or 20 (Section 22.6.5.3). If the column is close to two opposite edges, the punching shear check is skipped, as one-way shear governs.

The Two-way Shear Demand is calculated at the critical perimeter with the mesh-based method, from the finite element analysis of the footing. The upward force from the soil pressure inside the critical perimeter, \( F_{q} \), is the sum of the forces of the mesh elements in that area, and it is subtracted from the factored column load. The maximum shear stress \( v_{u} \) on the critical perimeter also includes the unbalanced moments transferred by eccentric shear (ACI 421.1R-20):

[math] v_{u} = \frac{P_{u} – F_{q}}{b_{o} \times d} + \frac{\gamma_{v,x} \times M_{u,x} \times c_{x}}{J_{c,x}} – \frac{\gamma_{v,z} \times M_{u,z} \times c_{z}}{J_{c,z}} \quad \text{(Eq. 5)} [math]

Pu = Factored column load
γv = Fraction of the unbalanced moment transferred by eccentric shear
Mu = Unbalanced moment: column moment, plus column shear times the column height and footing thickness, minus the column load times the offset of the centroid of the critical section (edge and corner columns)
c, Jc = Distance to the point considered and polar moment of inertia of the critical section
d = Effective depth, the average of the effective depths of the bottom bars in both directions

The Shear Capacity is the punching shear stress \( \phi v_{c} \), governed by the smallest value of Equations 6, 7 and 8 per Section 22.6.5.2. Unlike ACI 318-14, the 2019 edition includes the size effect factor \( \lambda_{s} \) (Section 22.5.5.1.3), which reduces the capacity of footings with an effective depth over 10 in (250 mm).

[math] \lambda_{s} = \min \left( 1, \sqrt{\frac{2}{1 + d/10}} \right) \quad \text{(Imperial)} \qquad \lambda_{s} = \min \left( 1, \sqrt{\frac{2}{1 + 0.004\,d}} \right) \quad \text{(Metric)} [math]

[math] v_{c} = 4 \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 6, Section 22.6.5.2(a), Imperial)} [math]

[math] v_{c} = \left( 2 + \frac{4}{\beta} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 7, Section 22.6.5.2(b), Imperial)} [math]

[math] v_{c} = \left( 2 + \frac{\alpha_{s} \times d}{b_{o}} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 8, Section 22.6.5.2(c), Imperial)} [math]

or

[math] v_{c} = 0.33 \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 6, Section 22.6.5.2(a), Metric)} [math]

[math] v_{c} = \left( 0.17 + \frac{0.33}{\beta} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 7, Section 22.6.5.2(b), Metric)} [math]

[math] v_{c} = \left( 0.17 + \frac{0.083 \times \alpha_{s} \times d}{b_{o}} \right) \lambda_{s} \lambda \sqrt{f’_{c}} \quad \text{(Eq. 8, Section 22.6.5.2(c), Metric)} [math]

[math] \phi v_{c} = \phi_{\text{shear}} \times \min \left( v_{c,a}, v_{c,b}, v_{c,c} \right) [math]

Note: β is the ratio of the long side to the short side of the column (1.0 for a round column, which is treated as an equivalent square), and \( \alpha_{s} \) is given by Section 22.6.5.3. ϕshear = 0.75 (Table 21.2.1).

λs = Size effect modification factor
λ = Modification factor to reflect the reduced mechanical properties of lightweight concrete relative to normal concrete of the same compressive strength
f’c = Specified compressive concrete strength (psi, MPa)
d = Effective depth, the average of the effective depths of the bottom bars in both directions, (in, mm)
bo = Critical perimeter (in, mm)

Shear Demand and Shear Capacity must meet the following equation to meet the design requirements of ACI 318-19:

[math] v_{u} \leq \phi v_{c} \quad \text{(Eq. 9, Section 7.5.1.1(b))} [math]

SkyCiv Foundation, in compliance with Equation 9, calculates the two-way shear utility ratio (Equation 10) by taking Shear Demand over Shear Capacity, both as stresses. The result is listed as Punching Shear in the Design Checks Summary.

[math] \text{Utility Ratio} = \frac{\text{Shear Demand}}{\text{Shear Capacity}} \quad \text{(Eq. 10)} [math]

Get started

Want to try it for yourself?

Try SkyCiv today for free!

Sign Up Free

Flexure

Moment Demand with the Strip Average Method

The Flexural Demand or \( M_{u} \) comes from the finite element analysis of the footing. With the Strip average method (the default Moment Demand Calculation), the footing is treated like a wide beam in each direction: the Wood-Armer moments of the plate elements are summed across the full width of the footing, along a strip through the column, which gives the total moment carried by the whole width at each section (Figure 3). This is done for the top and bottom layers, along x and along z, under the ultimate load combinations.

  • Bottom layer: \( M_{u} \) is the strip moment at the column faces, the larger of the two faces.
  • Top layer: \( M_{u} \) is the largest hogging (negative) strip moment along the strip.

Moment diagram, bottom layer along X, in SkyCiv Foundation Diagrams window: strip moment is 121.50 kN-m at both column edges

Figure 3. Strip average moment diagram, bottom layer along X (Results, Diagrams button)

The detailed report shows the same diagram for each layer and direction, with a table of the maximum moment, its coordinates and the governing load combination, followed by the utility ratio (Figure 4).

Design report: Bottom-X-direction moment demand, strip moment diagram peaking at 121.497 kN-m for U2a, ratio 0.598, PASS

Figure 4. Moment demand and utility ratio in the design report (View Detailed Report)

Peak Wood-Armer Method

With the Peak wood-armer method, \( M_{u} \) is instead the maximum Wood-Armer moment per unit width found anywhere over the footing, for the top and bottom layers in both directions, and the capacity is calculated per unit width (12 in or 1000 mm). Because it uses the peak moment, usually at the column, rather than the moment spread over the full width, it gives a more conservative design. It is described in the Isolated Footing Design Walkthrough with ACI 318-14, where it is the only method available.

Flexural Capacity

With the strip average method, the Flexural Capacity or \( \phi M_{n} \) is calculated for the full width of the footing, with all the bars of the layer across that width, using Equation 11.

[math] \phi M_{n} = \phi_{\text{flexure}} \times A_{s} \times f_{y} \times \left( d – \frac{a}{2} \right) \quad \text{(Eq. 11)} [math]

[math] a = \frac{A_{s} \times f_{y}}{0.85 \times f’_{c} \times b} [math]

ϕflexure = flexural strength reduction factor (Table 21.2.2)
As = area of the bars of the layer across the width of the footing (in2, mm2)
fy = reinforcement strength, (psi, MPa)
d = distance from extreme compression fiber to centroid of longitudinal tension reinforcement (in, mm)
a = depth of equivalent rectangular stress block (in, mm)
b = width of the footing perpendicular to the bars (in, mm)

The strength reduction factor depends on the net tensile strain \( \varepsilon_{t} \), found from the neutral axis depth \( c = a/\beta_{1} \) (β1 from Table 22.2.2.4.3) and a concrete strain of 0.003. ACI 318-19 compares it with the yield strain of the reinforcement \( \varepsilon_{ty} = f_{y}/E_{s} \):

[math] \phi_{\text{flexure}} = 0.65 + 0.25 \times \frac{\varepsilon_{t} – \varepsilon_{ty}}{0.003} \quad \text{(Table 21.2.2)} [math]

with ϕ = 0.90 when \( \varepsilon_{t} \geq \varepsilon_{ty} + 0.003 \) (tension-controlled) and ϕ = 0.65 when \( \varepsilon_{t} \leq \varepsilon_{ty} \) (compression-controlled). The report shows a warning when the section is not tension-controlled. When top bars are provided and the tension steel ratio exceeds the balanced ratio, the section is checked as doubly reinforced.

The provided reinforcement is also compared to the minimum area of 0.0018 Ag (Section 8.6.1.1), in each direction and for each layer. Without top bars, the top face is checked as plain concrete (Section 14.5.2.1):

[math] \phi M_{n} = \phi \times 5 \lambda \sqrt{f’_{c}} \times S \quad \text{(Imperial)} \qquad \phi M_{n} = \phi \times 0.42 \lambda \sqrt{f’_{c}} \times S \quad \text{(Metric)} [math]

ϕ = 0.60 for plain concrete
S = section modulus of the full width of the footing (b × h2/6)

Moment Demand and Moment Capacity must meet the following equation to meet the design requirements of ACI 318-19:

[math] M_{u} \leq \phi M_{n} \quad \text{(Eq. 12, Section 7.5.1.1(a))} [math]

SkyCiv Foundation, in compliance with Equation 12, calculates the flexural utility ratio (Equation 13) by taking Flexural Demand over Flexural Capacity. The Flexure ratio in the Design Checks Summary is the largest of the top, bottom and minimum reinforcement ratios. In the example, the bottom layer along X has a ratio of 121.5/203.01 = 0.598, and the Flexure ratio of 0.671 comes from the minimum reinforcement check.

[math] \text{Utility Ratio} = \frac{\text{Flexure Demand}}{\text{Flexure Capacity}} \quad \text{(Eq. 13)} [math]

Get started

Want to try it for yourself?

Try SkyCiv today for free!

Sign Up Free

Additional Verifications

Other verifications not mentioned by the code, including soil pressure checks, uplift, and other stability checks are also verified. The Design Checks Summary also lists Load Transfer (bearing at the column base), Development Length and Detailing. The development length checks are explained in the ACI 318 (2019) Development Length Check Guide.

Soil Pressure

The determination of base pressure or the interaction between the soil and footing primarily relies on the footing dimensions and the resulting eccentricity of the applied loads. Depending on the positioning of this resulting eccentricity, the base pressure can induce full or partial compression on the footing. This assessment enables us to confirm whether the underlying soil can sustain the entirety of the loads transmitted from the footing. SkyCiv Foundation takes the soil pressures from the finite element analysis of the footing.

Soil Pressure contour from the FEA in SkyCiv Foundation, with the Design Checks Summary showing Soil Bearing at 0.619

For a detailed guide for manually calculating the soil pressure, please refer to this link: Pressure Distribution Under a Rectangular Concrete Footing

The utility ratio is evaluated by comparing the maximum soil pressure (serviceability state) with the Gross Allowable Soil Bearing Capacity entered in the Soil tab. It is listed as Soil Bearing in the Design Checks Summary.

[math] \text{Utility Ratio} = \frac{\text{Max. Soil Pressure}}{\text{Gross Allowable Soil Bearing Capacity}} \quad \text{(Eq. 14)} [math]

Uplift

Checks the governing axial load acting on the footing, considering axial loads only. Sums all vertical loads including the user load and self-weights of the column, footing slab, soil, and buoyant force. If the column experiences an upward force, the self-weights specified must counterbalance the upward force; otherwise, the design risks failure due to instability. When no service load combination produces uplift, the check is not needed.

Overturning

Overturning of the footing is checked by summing up all moments about the toe and the heel of the footing in each direction, including all the forces acting on it. All service load combinations are considered to find the governing overturning moment. The factor of safety (stabilising moment over overturning moment) is compared with the Overturning factor of safety in the Design Factors tab (2.0 by default). If the applied loads produce no overturning moment, the check is not needed.

Sliding

To check for sliding in each direction, the sum of the horizontal resisting forces is divided by the horizontal force applied to the footing, taken from the governing service load combination.

  • Resisting forces:
    • Friction between the footing base and the soil (coefficient of friction times the axial force on the base; none under net uplift)
    • Passive soil pressure
    • Cohesion of the soil
  • Sliding force:
    • The horizontal (shear) load applied to the column

The resulting factor of safety is compared with the Sliding factor of safety in the Design Factors tab (1.5 by default). If no horizontal force is acting on the footing, checking for sliding is not required.

SkyCiv Foundation Design Module

SkyCiv’s Foundation Design Module is integrated with Finite Element Analysis (FEA), delivering more accurate soil pressure analysis and Wood-Armer moments for the flexural design checks.

Shear and moment diagrams are generated directly from the FEA results using the strip average method, providing a clearer picture of internal forces across the footing. Open them with the Diagrams button of the Results tab, and pick the Case, the Diagram (One-way Shear, Punching Shear or Moment), the Load Combination, the Layer and the Direction.

The module supports advanced footing configurations, including column offsets in any direction for both isolated and combined footings. Loads and moments can also be applied in any direction, allowing for accurate modeling of real-world foundation conditions.

Not a SkyCiv User? Sign up for a Free 14 Day Trial to get started!

Jerome Carlo San Juan Product Developer
Jerome Carlo San Juan
Product Developer
BSc (Civil), MSc (Civil)
LinkedIn

References