SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

Combined Footing Design in Accordance with AS 3600:2018

This page explains how SkyCiv Foundation designs a combined footing to the Australian Standard AS 3600:2018: soil bearing, one-way shear, punching shear and flexure, with the equations used and the results shown in the software and the calculation report, followed by the other design checks (uplift, overturning, sliding, load transfer, development length and detailing). Flexure is described with the default Strip average method, and the Peak wood-armer method is summarized for comparison.

A combined footing is a single footing supporting two columns. It is commonly used when the columns are too close to each other, or a column is too close to a property line, for two separate isolated footings. SkyCiv Foundation meshes the footing into plate elements supported on the soil (modeled with the subgrade modulus) and analyzes it with finite element analysis (FEA). The soil pressures, shears and moments used in the design checks below come from these FEA results. To design to the 2018 edition, select Australian Standard as the Design Code and AS 3600:2018, AS 2159:2009 as the Version when you start a new file, then pick Combined Footing. The same checks for an isolated footing are walked through in Isolated Footing Design Walkthrough with AS 3600 2018.

SkyCiv Foundation Geometry tab, AS 3600:2018 combined footing CF01, 3000×1500×500 mm, 3D model of columns, soil and N20 bars

The example shown on this page is the default AS 3600:2018 combined footing: 3000 × 1500 × 500 mm, with two 300 × 300 mm columns placed 250 mm from the ends of the footing (X-edge Distance), N20 bars at 300 mm in both directions at the top and bottom, a 75 mm cover, f’c = 32 MPa and fsy = 500 MPa. Column 1 carries a permanent load (G) of 200 kN and an imposed load (Q) of 100 kN, and Column 2 a permanent load of 250 kN and an imposed load of 120 kN. The x-direction is the direction joining the two columns.

Design Settings for AS 3600:2018

The methods used for the checks are set in Edit Design Settings (Details tab). For a combined footing designed to AS 3600:2018, the dialog holds:

  • Include soil and footing weight: includes the self-weight of the footing and of the soil above it in the stability (STA, on by default), serviceability (SLS, on by default) and strength (ULS, off by default) load combinations.
  • Perform One-Way Shear Check: turns the one-way shear check on or off (enabled by default). See One-way Shear.
  • Punching Shear Edge Factor: multiplied by the effective depth to classify each column as an interior, edge or corner column (0.5 by default, at least 0.5). See Two-way Shear (Punching Shear).
  • Moment Demand Calculation: Strip average method (default) or Peak wood-armer method. See Flexure.
  • Perform load transfer check: turns the bearing check at the column bases on or off (enabled by default).
  • Development Length Checks: the Perform dowel bars check, Perform top bars check and Perform bottom bars check switches (all enabled by default) turn the development length checks on or off.

For AS 3600, the punching shear demand is always calculated with the mesh-based method, so the dialog has no punching shear demand option.

Design Settings dialog for AS 3600:2018 in SkyCiv Foundation, with Punching Shear Edge Factor 0.5 and Strip average outlined

Combined Footing Design Checks to AS 3600:2018

Dimension Requirements and Soil Bearing

To size a combined footing, the characteristic actions, such as permanent (G), imposed (Q), wind (Wu, Ws), earthquake (Eu) and snow (Su) loads, are combined with the serviceability load combinations. The governing combination is the design load, and the base area is proportioned so that the allowable soil pressure is not exceeded:

[math] q_{a} = \frac{P1_{n} + P2_{n}}{A} \quad \text{(Eq. 1)} [math]

qa = Allowable soil pressure
P1n, P2n = Unfactored loads at Column 1 (left) and Column 2 (right)
A = Foundation area

Solving Equation 1 for the area gives a first estimate of the footing dimensions:

[math] A = \frac{P1_{n} + P2_{n}}{q_{a}} \quad \text{(Eq. 1a)} [math]

SkyCiv Foundation does not size the footing from Equation 1a: the dimensions are inputs (Geometry tab), and the software checks them. The Soil Bearing ratio is the maximum soil pressure from the FEA results of the serviceability load combinations (envelope), which includes the effect of the column moments and of the eccentricity of the loads, divided by the Gross Allowable Soil Bearing Capacity entered in the Soil tab (500 kPa by default):

[math] \text{Ratio} = \frac{q_{sls,max}}{q_{a}} \quad \text{(Eq. 2)} [math]

For AS 3600, the Soil tab also offers the Perform ULS soil bearing check toggle (off by default). When it is on, the maximum soil pressure under the strength load combinations is also compared with the Ultimate Soil Bearing Capacity multiplied by the Geotechnical Reduction Factor \( \phi_{g} \) (0.5 by default), and the Soil Bearing ratio is the larger of the two ratios:

[math] \text{Ratio}_{uls} = \frac{q_{uls,max}}{\phi_{g} \times q_{u}} \quad \text{(Eq. 3)} [math]

In the example, the maximum service soil pressure is 223.5 kPa, under Column 2, which carries the larger load, and the Soil Bearing ratio is 0.447. The soil pressure contour and the ratio of every check are shown in the Results tab:

SkyCiv Foundation Results tab, AS 3600:2018 combined footing: soil pressure contour 223.5 kPa, Design Checks Summary ratios

Get started

Want to try it for yourself?

Try SkyCiv today for free!

Sign Up Free

One-way Shear

The one-way shear limit state, also known as beam shear, treats the footing like a wide beam that may fail in shear along a critical section across the width of the footing. It is checked when Perform One-Way Shear Check is enabled in the design settings (on by default).

The critical sections are located at the effective shear depth \( d_{v} \) from the column faces (AS 3600:2018, Clause 8.2.1.9), calculated in each direction from the effective depth of the bottom bars in that direction:

[math] d_{v} = \max \left( 0.72\,D, \; 0.9\,d \right) \quad \text{(Eq. 4)} [math]

D = Footing thickness
d = Effective depth of the bottom bars in the direction checked

In the example, the bottom x-bars have d = 415 mm, so \( d_{v,x} \) = max(360, 373.5) = 373.5 mm, and the bottom z-bars have d = 395 mm, so \( d_{v,z} \) = 360 mm.

The One-way Shear Demand or \( V^{*} \) is taken from the strip average shear diagrams of the FEA (strength load combinations): the shear forces of the plate elements are summed across the width of the footing, and the diagram is read at the critical sections. The largest absolute shear at these sections is the demand.

  • Along x (the direction joining the columns), one diagram covers the whole footing, with the critical sections on both sides of both columns.
  • Along z, each column has its own diagram, through that column.

The diagrams can be viewed in the Results tab by opening Diagrams and choosing One-way Shear in the Diagram list. The plan on the left shows the critical sections as dashed lines, with their distance from the column faces. In the example, the demand along x is 168.67 kN, next to Column 2:

Along X one-way shear diagram in SkyCiv Foundation: critical sections at dv = 373.5 mm, demand 168.67 kN at Column 2

Figure 1. Critical sections and shear diagram of one-way shear along x (Results, Diagrams button)

The One-way Shear Capacity \( \phi V_{u} \) is the smaller of the concrete contribution \( V_{uc} \) (Clause 8.2.4.1) and the web crushing limit \( V_{u.max} \) (Clause 8.2.3.3), both multiplied by \( \phi_{s} \) = 0.7 (Table 2.2.2). The footing has no shear reinforcement:

[math] k_{v} = \frac{200}{1000 + 1.3\,d_{v}} \qquad 0.10 \leq k_{v} \leq 0.15 \quad \text{(Eq. 5, Clause 8.2.4.3)} [math]

[math] V_{uc} = k_{v} \, b_{v} \, d_{v} \sqrt{f’_{c}} \quad \text{(Eq. 6, Clause 8.2.4.1)} [math]

[math] V_{u.max} = 0.55 \left[ 0.9 \, f’_{c} \, b_{v} \, d_{v} \, \frac{\cot \theta_{v} + \cot \alpha_{v}}{1 + \cot^{2} \theta_{v}} \right] \quad \text{(Eq. 7, Clause 8.2.3.3)} [math]

[math] \phi V_{u} = \min \left( \phi_{s} V_{u.max}, \; \phi_{s} V_{uc} \right) \quad \text{(Eq. 8)} [math]

kv = Concrete shear strength factor
bv = Width resisting the shear (mm)
dv = Effective shear depth in the direction checked (mm)
f’c = Concrete compressive strength, limited to 65 MPa in Equation 6 (MPa)
θv = Angle of the compression strut, taken as 36°
cot αv = 0, as there is no inclined shear reinforcement

Along x, \( b_{v} \) is the full width of the footing (its dimension along z). Along z, the footing is divided into two design strips at the midpoint between the two columns, and each column’s shear is checked against the capacity of its own strip, with \( b_{v} \) equal to the strip width (1500 mm for both strips in the example). The report also compares the footing thickness with 750 mm (Clause 8.2.1.6) and warns when transverse shear reinforcement should be considered.

The calculation report shows the shear diagram of each direction, followed by the demand, the capacity and the ratio. Along x in the example, \( k_{v} \) = 0.1346, \( V_{uc} \) = 426.68 kN and \( V_{u.max} \) = 4220 kN, so \( \phi V_{u} \) = 0.7 × 426.68 = 298.67 kN and the ratio is 168.67/298.67 = 0.565:

SkyCiv Foundation AS 3600:2018 report: one-way shear capacity along x is 298.67 kN, demand 168.67 kN, ratio 0.565, PASS

Shear Demand and Shear Capacity must meet the following equation to meet the design requirements of AS 3600:2018:

[math] V^{*} \leq \phi V_{u} \quad \text{(Eq. 9)} [math]

SkyCiv Foundation, in compliance with Equation 9, calculates the one-way shear utility ratio by taking Shear Demand over Shear Capacity, along x and for each column along z. The largest ratio is listed as One-Way Shear in the Design Checks Summary.

[math] \text{Ratio} = \frac{V^{*}}{\phi V_{u}} \quad \text{(Eq. 10)} [math]

Get started

Want to try it for yourself?

Try SkyCiv today for free!

Sign Up Free

Two-way Shear (Punching Shear)

The two-way shear limit state, also known as punching shear, has its critical shear perimeter \( u \) at a distance \( d_{om}/2 \) from the faces of the column. The check is done for each column. The critical perimeters can be viewed in the Results tab by opening Diagrams and choosing Punching Shear in the Diagram list:

Punching Shear diagram in SkyCiv Foundation: 3000 by 1500 combined footing plan with dashed 0.5d perimeters on two columns

Figure 2. Critical perimeters of punching shear (Results, Diagrams button)

The effective depth \( d_{om} \) is the average of the effective depths of the bottom bars in both directions (405 mm in the example). When a column face is closer to a footing edge than the Punching Shear Edge Factor times \( d_{om} \) (0.5 × 405 = 202.5 mm in the example), the perimeter on that side extends to the footing edge and is not counted in \( u \). The column is then classified as an interior, edge or corner column. If the column is close to two opposite edges, the punching shear check is skipped for that column, as one-way shear governs (reduce the edge factor to force the check). A round column is taken as an equivalent square column with sides equal to its diameter. In the example, the outer faces of the columns are 250 mm from the ends of the footing, so both columns are interior columns, with \( u \) = 4 × (300 + 405) = 2820 mm.

Punching Shear Demand with the Mesh-based Method

The Punching Shear Demand \( V^{*} \) is calculated with the mesh-based method, from the finite element analysis of the footing. The upward force from the soil pressure inside the critical shear area, \( \sum F_{q,i} \), is the sum of the forces of the mesh elements in that area, each one the average soil pressure on the element times its area inside the critical perimeter. This force is subtracted from the factored column load:

[math] F_{q,i} = q_{ave} \times A_{mesh} \quad \text{(Eq. 11)} [math]

[math] V^{*} = P_{uls} – \sum F_{q,i} \quad \text{(Eq. 12)} [math]

qave = Average soil pressure on the mesh element (strength load combinations, envelope)
Amesh = Total or partial area of the mesh element inside the critical shear area
Puls = Factored column load, including the self-weight of the column

The calculation report shows, for each column, the plan of the critical shear area, the coordinates of its corners and a table of the force of every mesh element inside it:

SkyCiv Foundation AS 3600:2018 report: plan view of 3000 × 1500 footing, Column 2 interior case, dashed 0.5d critical perimeter

SkyCiv Foundation AS 3600:2018 report: critical shear area corner coordinates and mesh element forces Fq,i for Column 2

Punching Shear Capacity

The Punching Shear Capacity is the ultimate shear strength with no moment transfer \( V_{uo} \) (Clause 9.3.3(a)), multiplied by \( \phi_{s} \) = 0.7:

[math] \beta_{h} = \frac{\max \left( b_{c}, D_{c} \right)}{\min \left( b_{c}, D_{c} \right)} \quad \text{(Eq. 13, Clause 9.3.1.4)} [math]

[math] f_{cv} = \min \left[ 0.17 \left( 1 + \frac{2}{\beta_{h}} \right) \sqrt{f’_{c}}, \; 0.34 \sqrt{f’_{c}} \right] \quad \text{(Eq. 14, Clause 9.3.3(a))} [math]

[math] V_{uo} = u \, d_{om} \, f_{cv} \quad \text{(Eq. 15)} [math]

[math] \phi V_{u} = \phi_{s} \times V_{uo} \quad \text{(Eq. 16)} [math]

bc, Dc = Column dimensions (mm)
f’c = Concrete compressive strength (MPa)
u = Length of the critical shear perimeter (mm)
dom = Average effective depth of the bottom bars (mm)

In the example, \( \beta_{h} \) = 1, so \( f_{cv} \) = 0.34 × √32 = 1.923 MPa, \( V_{uo} \) = 2820 × 405 × 1.923 = 2196.6 kN and \( \phi V_{u} \) = 1537.6 kN. For Column 2, the factored load is 481.27 kN and the soil inside the critical shear area pushes up 125.87 kN, so \( V^{*} \) = 355.4 kN:

SkyCiv Foundation AS 3600:2018 report: Column 2 punching shear demand 481.27 - 125.87 = 355.4 kN, ratio 0.231, PASS

Shear Demand and Shear Capacity must meet the following equation to meet the design requirements of AS 3600:2018:

[math] V^{*} \leq \phi V_{u} \quad \text{(Eq. 17)} [math]

SkyCiv Foundation, in compliance with Equation 17, calculates the punching shear utility ratio of each column by taking Shear Demand over Shear Capacity. The larger ratio of the two columns is listed as Punching Shear in the Design Checks Summary (0.231 in the example, from Column 2).

[math] \text{Ratio} = \frac{V^{*}}{\phi V_{u}} \quad \text{(Eq. 18)} [math]

Get started

Want to try it for yourself?

Try SkyCiv today for free!

Sign Up Free

Flexure

SkyCiv Foundation checks the top and bottom reinforcement in both directions against the moments of the whole footing from the FEA, rather than at a single critical section. In a combined footing, the top bars along x resist the hogging moment between the columns, and the bottom bars resist the sagging moments under the columns and in the transverse direction.

Moment Demand with the Strip Average Method

With the Strip average method (the default Moment Demand Calculation), the footing is treated like a wide beam in each direction: the Wood-Armer moments of the plate elements are summed across the width of the footing, which gives the total moment carried by that width at each section. This is done for the top and bottom layers, along x and along z, under the strength load combinations (envelope).

  • Along x, the strip covers the full width of the footing, and one moment diagram covers both columns.
  • Along z, the footing is divided into two design strips at the midpoint between the column centres, and each column has its own diagram.
  • Bottom layer: \( M^{*} \) is the largest strip moment at the column faces.
  • Top layer: \( M^{*} \) is the largest hogging (negative) strip moment anywhere along the strip.

The moment diagrams can be viewed in the Results tab by opening Diagrams, choosing Moment in the Diagram list, and picking the Layer and Direction. In the example, the top layer along x has a maximum hogging moment of 151.22 kN-m, midway between the columns:

Moment diagram in SkyCiv Foundation: Ultimate envelope, top layer along X, hogging moment peaking at -151.22 kN-m at 1.5 m

Figure 3. Strip average moment diagram, top layer along x (Results, Diagrams button)

The calculation report shows the same diagram for each layer and direction, with a table of the maximum moment, its coordinates and the governing load combination (Str2, 1.2G + 1.5Q, in the example), followed by the utility ratio:

SkyCiv Foundation AS 3600:2018 report: top layer moment demand along x, maximum -151.22 kNm at 1.5 m, load combination Str2

Peak Wood-Armer Method

With the Peak wood-armer method, \( M^{*} \) is instead the maximum Wood-Armer moment per unit width found anywhere over the footing, for the top and bottom layers in both directions, and the capacity is calculated for a 1000 mm width, with the bar area per metre (bar area × 1000 / spacing). Because it uses the peak moment rather than the moment spread over the width, it is usually more conservative. The Wood-Armer moments can be viewed in the Results tab with the Wood Armer button.

Flexural Capacity

With the strip average method, the Flexural Capacity \( \phi M_{u} \) is calculated for the width of the strip, with the bars of the layer across that width. The number of bars across a footing dimension L is:

[math] n = \frac{L – 2\,c – d_{b}}{s} + 1 \quad \text{(rounded up)} [math]

c = Concrete cover, db = Bar diameter, s = Bar spacing

Along z, each strip takes the share of the bars in proportion to its width. The rectangular stress block factors are taken from Clause 8.1.3:

[math] \alpha_{2} = \max \left( 0.85 – 0.0015\,f’_{c}, \; 0.67 \right) \qquad \gamma = \max \left( 0.97 – 0.0025\,f’_{c}, \; 0.67 \right) [math]

When the steel ratio does not exceed \( \rho_{max} = 0.4\,\alpha_{2}\,\gamma\,f’_{c}/f_{sy} \), the section is singly reinforced, and the depth of the neutral axis and the capacity are:

[math] d_{n} = \frac{A_{s} \, f_{sy}}{\alpha_{2} \, f’_{c} \, b \, \gamma} \qquad k_{u} = \frac{d_{n}}{d} [math]

[math] \phi = 1.24 – \frac{13\,k_{u}}{12} \qquad 0.65 \leq \phi \leq 0.85 \quad \text{(Table 2.2.2(b))} [math]

[math] \phi M_{u} = \phi \, f_{sy} \, A_{s} \, d \left( 1 – \frac{\gamma \, k_{u}}{2} \right) \quad \text{(Eq. 19)} [math]

As = Area of the tension bars across the strip width (mm2)
fsy = Yield strength of the reinforcement (MPa)
b = Strip width: the full width of the footing along x (mm)
d = Effective depth of the tension bars (mm)
ku = Neutral axis parameter

The report shows a warning when \( k_{u} \) > 0.36 (non-ductile section). When the steel ratio exceeds \( \rho_{max} \), the section is checked as doubly reinforced, with the bars of the other layer as compression reinforcement.

In the example, the 6 top bars along x (1885 mm²) across the 1500 mm width give \( d_{n} \) = 27.51 mm and \( k_{u} \) = 0.066, so \( \phi \) = 0.85 and \( \phi M_{u} \) = 322.65 kN-m. The top layer ratio along x is 151.22/322.65 = 0.469.

The provided reinforcement of each layer, in each direction, is also compared with the minimum area for strength, with the characteristic flexural tensile strength of the concrete \( f’_{ct.f} = 0.6\sqrt{f’_{c}} \) (Clause 3.1.1.3):

[math] A_{s,min} = 0.19 \left( \frac{D}{d} \right)^{2} \frac{f’_{ct.f}}{f_{sy}} \, L \, d \quad \text{(Eq. 20)} [math]

where L is the footing dimension across which the bars are placed. In the example, the bars along z (11 N20 across the 3000 mm length, 3455.8 mm²) need \( A_{s,min} \) = 2448.9 mm², a ratio of 0.709.

Moment Demand and Moment Capacity must meet the following equation to meet the design requirements of AS 3600:2018:

[math] M^{*} \leq \phi M_{u} \quad \text{(Eq. 21)} [math]

SkyCiv Foundation, in compliance with Equation 21, calculates the flexural utility ratio by taking Flexural Demand over Flexural Capacity, for the top and bottom layers along x and for each strip along z. The Flexure ratio in the Design Checks Summary is the largest of the top, bottom and minimum reinforcement ratios (0.709 in the example, from the minimum reinforcement along z).

[math] \text{Ratio} = \frac{M^{*}}{\phi M_{u}} \quad \text{(Eq. 22)} [math]

Get started

Want to try it for yourself?

Try SkyCiv today for free!

Sign Up Free

Other Design Checks

Besides the checks above, the calculation report of a combined footing designed to AS 3600:2018 includes the stability checks, the load transfer at the column bases, the development length of the bars and a detailing check. Each one gives a utilization ratio in the Design Checks Summary of the Results tab, and the footing fails when a ratio is greater than 1.0. A check that does not apply to the loads (for example sliding without horizontal loads) is shown with a dash.

Uplift

The uplift check compares the upward forces with the forces holding the footing down, considering axial loads only: the column loads, the self-weights of the columns, footing and soil, and the buoyant force. When no load combination produces uplift, the ratio is zero.

Overturning

Overturning is checked with the stability load combinations (Sta): the destabilising moments are compared with the stabilising moments about the toe and the heel of the footing, in each direction. Only the loads that destabilise the footing are counted in the destabilising moments, and only those that stabilise it in the stabilising moments. If the loads produce no overturning moment, the ratio is zero.

Sliding

Sliding is checked in each direction by comparing the horizontal force applied to the footing with the horizontal resistance: the friction between the footing base and the soil, the passive soil pressure and the cohesion of the soil. If no horizontal force acts on the footing, the check is not needed.

Load Transfer

The Load Transfer check verifies the bearing of each column on the footing (Clause 12.6). The factored axial load of the column is compared with the design bearing strength, with \( \phi \) = 0.6 (Table 2.2.2):

[math] \phi B_{n} = \min \left( \phi \times 0.9 f’_{c} \sqrt{\frac{A_{2}}{A_{1}}} \, A_{1}, \; \phi \times 1.8 f’_{c} \, A_{1} \right) \quad \text{(Eq. 23)} [math]

A1 = Bearing area (the column area)
A2 = Larger distributed area under the column: on each side, its projection beyond the column is the smaller of the distance to the footing edge and 2 times the footing thickness

In the example, \( A_{2} \) = 1550 × 1500 mm for both columns, so \( \phi B_{n} \) = 0.6 × 1.8 × 32 × 90000 = 3110.4 kN, and the larger ratio of the two columns, 481.27/3110.4 = 0.155, is listed as Load Transfer.

Development Length

The Development Length check follows Section 13 of AS 3600:2018 and covers the column starter bars and the flexural bars of the footing:

  • Column starter bars: the development length in compression \( L_{sy.cb} \) of the starter bars must fit in the footing thickness, with the bend of the bar and the cover.
  • Flexural bars: the tension development length \( L_{sy.t} \) of the top and bottom bars, with the factors \( k_{1} \), \( k_{2} \) and \( k_{3} \), is compared with the anchorage length available beyond the critical sections near the columns, depending on the bar ends chosen in the Reinforcement tab (straight, 90° cog or 180° hook).

The checks can be turned on or off in the design settings (Perform dowel bars check, Perform top bars check and Perform bottom bars check). In the example, the Development Length ratio of 1.100 comes from the column starter bars: with \( L_{sy.cb} \) = 435 mm, they need a footing thickness of 550 mm, more than the 500 mm provided. The development length checks are explained in more detail in the AS 3600: Development Length Check Guide, written for isolated footings.

Detailing

The Detailing check verifies that the footing thickness can hold the hooked ends of the top and bottom bars (90° cogs or 180° hooks), with their bend and extension and the top and bottom covers (0.860 in the example).

Get started

Want to try it for yourself?

Try SkyCiv today for free!

Sign Up Free
Jerome Carlo San Juan Product Developer
Jerome Carlo San Juan
Product Developer
BSc (Civil), MSc (Civil)
LinkedIn

References

  1. AS 3600:2018 Concrete structures. Standards Australia, 2018.
  2. AS/NZS 1170.0:2002 Structural design actions, Part 0: General principles. Standards Australia and Standards New Zealand, 2002.

How can we help?

×

Updated November 26, 2026

Still stuck? Contact us

Go to Top