Documentação SkyCiv

Seu guia para o software SkyCiv – tutoriais, guias de instruções e artigos técnicos

Verificação de ação curiosa para conexões aparafusadas (AISC)

Prying action is the extra tension that bolts pick up when the plate they clamp bends. When an end plate, angle leg or tee flange is pulled away from its support, its edges press against the support and act like a lever on the bolts, so each bolt carries more than its share of the applied tension. The AISC Steel Construction Manual, Parte 9, gives a procedure that checks the bolts and the fitting together. This article explains that procedure and works it with the numbers from a real end plate connection solved in SkyCiv Connection Design.

O que é ação curiosa?

Picture a tee stub bolted to a column flange and pulled by its stem. If the flange of the tee is thick, it stays flat and each bolt carries the applied tension divided by the number of bolts. If the flange is thin, it bends: the middle lifts off, the outer edges dig into the column, and those edge contact forces, called prying forces, add to the bolt tension. A thin fitting can therefore fail the bolts even when the bolts look strong enough on their own, and the fitting itself can yield in bending.

Prying governs in connections that carry tension through bolts and a plate in bending: end plates and double angles under axial tension, hanger connections, tee stubs and the column flange on the other side of the bolts. It does not apply to bolts loaded only in shear. It matters most when the bolt gage is wide compared with the plate thickness, because the distance from the bolt to the face of the web, [mathin] b [mathin], is the lever arm of the bending.

The AISC Manual Part 9 prying procedure

SkyCiv follows the Manual Part 9 procedure that gives the minimum fitting thickness, [mathin] t_{min} [mathin], for which the bolts, with prying, are not overloaded. The check passes when [mathin] t_{min} [mathin] is not greater than the actual thickness. The terms are:

  • [mathin] b [mathin], the distance from the bolt centreline to the face of the web or stem
  • [mathin] d_{b} [mathin], the bolt diameter, e [mathin] d_{h} [mathin], the hole size along the length of the fitting
  • [mathin] L_{eh} [mathin], the edge distance from the bolt to the edge of the fitting
  • [mathin] p = \min\left( 3.5b,\ s_{r} \right) [mathin], the tributary length of fitting per bolt, com [mathin] s_{r} [mathin] the bolt pitch
  • [mathin] B [mathin], the available tension per bolt, e [mathin] T_{u} [mathin], the total tension on the connection, shared by [mathin] 2n_{r} [mathin] parafusos
  • [mathin] F_{u} [mathin], the tensile stress of the fitting

The ratio of net to gross area along the bolt line is:

[math] \delta = 1 – \frac{d_{h}}{\min\left( 3.5b,\ s_{r} \right)} [math]

The bolt strength term [mathin] \beta [mathin], written with the total tension [mathin] T_{u} [mathin] e [mathin] n_{r} [mathin] fileiras de parafusos:

[math] \beta = \frac{\min\left( L_{eh} + 0.5d_{b},\ 1.25b + 0.5d_{b} \right) \left( 2T_{u} – 4Bn_{r} \right)}{T_{u} \left( d_{b} – 2b \right)} [math]

This is the Manual’s [mathin] \beta = \frac{1}{\rho} \left( \frac{B}{T} – 1 \right) [mathin] com [mathin] T = T_{u}/(2n_{r}) [mathin] por parafuso, [mathin] \rho = b’/a’ [mathin], [mathin] b’ = b – 0.5d_{b} [mathin] e [mathin] a’ = \min\left( L_{eh},\ 1.25b \right) + 0.5d_{b} [mathin]. Então:

[math] \alpha’ = \min\left[ 1,\ \left| \frac{1}{\delta} \left( \frac{\beta}{1 – \beta} \right) \right| \right] [math]

[math] t_{min} = \sqrt{ \frac{2.22 T_{u} \left( b – 0.5d_{b} \right)}{\min\left( 3.5b,\ s_{r} \right) F_{u} n_{r} \left( 1 + \delta \alpha’ \right)} } [math]

A 2.22 is the Manual’s [mathin] 4/\phi [mathin] com [mathin] \phi = 0.90 [mathin], halved because [mathin] T_{u} [mathin] is shared by two bolts per row (Equação manual. 9-19uma).

A tensão disponível por parafuso [mathin] B [mathin] includes the effect of the shear on the same bolts (AISC 360-16 J3.6 and J3.7):

[math] B = 0.589 d_{b}^{2} \min\left[ 1.3F_{nt} – \frac{0.849 F_{nt} V_{r}}{F_{nv} n_{r} d_{b}^{2}},\ F_{nt} \right] [math]

Aqui 0.589 é [mathin] \phi \pi/4 [mathin] com [mathin] \phi = 0.75 [mathin], então [mathin] B [mathin] é [mathin] \phi F’_{nt} A_{b} [mathin].

Worked example: end plate and column flange in prying

This example is Checks 12 para 14 do end plate shear and axial connection design example: uma viga W18x35 com 3/4 em A572 Gr. 50 placa final, bolted to the flange of a W14x90 column with three rows of two 3/4 in A325-N bolts at a 5 1/2 em calibre e 3 em campo. The connection carries [mathin] T_{u} = 93\ \text{kip} [mathin] axial tension and [mathin] V_{r} = 32\ \text{kip} [mathin] o cisalhamento. It was solved again on the current release and the numbers are the same as on the published example.

Elevation of a W18x35 end plate on a W14x90 column flange with 93 kip tensão axial ou compressão e 32 kip de cisalhamento

Elevação. The end plate is pulled away from the column flange by the 93 tensão, so both the plate and the column flange bend around the bolts.

Bolt tension with shear present (Verificar 12)

Com [mathin] F_{nt} = 90\ \text{ksi} [mathin] e [mathin] F_{nv} = 54\ \text{ksi} [mathin], the reduced term [mathin] 1.3F_{nt} – 0.849F_{nt}V_{r}/(F_{nv}n_{r}d_{b}^{2}) [mathin] é 90.167 ksi, just above [mathin] F_{nt} [mathin], so the shear does not reduce the tension strength here:

[math] B = 0.589 \times 0.75^{2} \times \min\left[ 1.3 \times 90 – \frac{0.849 \times 90 \times 32}{54 \times 3 \times 0.75^{2}},\ 90 \right] = 29.818\ \text{kip} [math]

[math] \phi R_{n} = 2n_{r} B = 2 \times 3 \times 29.818 = 178.91\ \text{kip}, \quad DCR = \frac{93}{178.91} = 0.51982 [math]

End plate in prying (Verificar 13)

For the end plate, [mathin] b = 2.6\ \text{in} [mathin] (metade do 5 1/2 in gage less half the 0.3 em teia de feixe), [mathin] L_{eh} = 1.5\ \text{in} [mathin], the slot is [mathin] d_{h} = 1\ \text{in} [mathin] along the plate and [mathin] F_{up} = 65\ \text{ksi} [mathin]. Como [mathin] 3.5b = 9.1\ \text{in} [mathin], the pitch of 3 in governs [mathin] p [mathin].

[math] \delta = 1 – \frac{1}{\min\left( 3.5 \times 2.6,\ 3 \right)} = 0.66667 [math]

[math] \beta = \frac{\min\left( 1.5 + 0.5 \times 0.75,\ 1.25 \times 2.6 + 0.5 \times 0.75 \right) \times \left( 2 \times 93 – 4 \times 29.818 \times 3 \right)}{93 \times \left( 0.75 – 2 \times 2.6 \right)} = 0.77844 [math]

[math] \alpha’ = \min\left[ 1,\ \left| \frac{1}{0.66667} \left( \frac{0.77844}{1 – 0.77844} \right) \right| \right] = 1 [math]

[math] t_{min} = \sqrt{ \frac{2.22 \times 93 \times \left( 2.6 – 0.5 \times 0.75 \right)}{3 \times 65 \times 3 \times \left( 1 + 0.66667 \times 1 \right)} } = 0.68641\ \text{in} [math]

[math] DCR = \frac{t_{min}}{t_{p}} = \frac{0.68641}{0.75} = 0.91521 [math]

Column flange in prying (Verificar 14)

The column flange is the fitting on the other side of the same bolts. For the W14x90, [mathin] b = 2.53\ \text{in} [mathin] (half the gage less half the 0.44 in column web), the edge distance to the flange tip is [mathin] L_{eh,sup} = 4.5\ \text{in} [mathin], the holes are standard, [mathin] d_{h} = 0.8125\ \text{in} [mathin], e [mathin] F_{us} = 65\ \text{ksi} [mathin].

[math] \delta = 1 – \frac{0.8125}{\min\left( 3.5 \times 2.53,\ 3 \right)} = 0.72917 [math]

[math] \beta = \frac{\min\left( 4.5 + 0.5 \times 0.75,\ 1.25 \times 2.53 + 0.5 \times 0.75 \right) \times \left( 2 \times 93 – 4 \times 29.818 \times 3 \right)}{93 \times \left( 0.75 – 2 \times 2.53 \right)} = 1.5164 [math]

Com [mathin] \beta [mathin] acima 1, [mathin] \alpha’ = 1 [mathin], e:

[math] t_{min} = \sqrt{ \frac{2.22 \times 93 \times \left( 2.53 – 0.5 \times 0.75 \right)}{3 \times 65 \times 3 \times \left( 1 + 0.72917 \times 1 \right)} } = 0.6632\ \text{in} [math]

[math] DCR = \frac{t_{min}}{t_{fs}} = \frac{0.6632}{0.71} = 0.93409 [math]

The column flange at 0.93409 and the end plate at 0.91521 are two of the three highest DCRs in this connection, just behind the beam side weld at 0.935224. The bolts themselves are only at 0.51982 in direct tension: on the support side it is the bending of the plates that limits this connection, not the bolt size.

How SkyCiv Connection Design reports it

Prying appears in the summary of checks as separate rows for the bolts and for each fitting: "Design Capacity of the Bolts in Tension at Support Side", "Design Capacity of End Plate in Bolt Prying" and "Design Capacity of Column Flange in Bolt Prying". For the prying rows the demand is [mathin] t_{min} [mathin] and the capacity is the actual thickness, so the DCR is a thickness ratio (0.686405 contra 0.75 no, e 0.663201 contra 0.71 no, aqui). Each row links to the calculation, which lists [mathin] b [mathin], [mathin] L_{eh} [mathin], [mathin] d_{h} [mathin] e [mathin] B [mathin], then works out [mathin] \delta [mathin], [mathin] \beta [mathin], [mathin] \alpha’ [mathin] e [mathin] t_{min} [mathin] with the numbers substituted, and ends with PASS or FAIL. The governing row is highlighted in the summary.

What to change if it fails

  • Use a thicker end plate, angle or tee: [mathin] t_{min} [mathin] is fixed by the load and geometry, so a thicker fitting passes directly.
  • Reduce the gage: a smaller [mathin] b [mathin] shortens the lever arm, which lowers [mathin] t_{min} [mathin], as long as the bolts still fit around the web and the welds.
  • Add bolt rows or reduce the pitch: more rows share the tension, which lowers [mathin] T_{u}/n_{r} [mathin].
  • Use larger or stronger bolts: a larger [mathin] B [mathin] raises [mathin] \beta [mathin] e [mathin] \alpha’ [mathin], which lowers [mathin] t_{min} [mathin] until [mathin] \alpha’ [mathin] reaches 1. Both fittings here are already at [mathin] \alpha’ = 1 [mathin], so bigger bolts would not lower their [mathin] t_{min} [mathin].
  • Para o flange da coluna, a heavier column with a thicker flange, or stiffeners at the level of the bolts, are the usual fixes.

Perguntas frequentes

Why does prying make the bolts fail before the plate?

The prying forces at the edges of a bending plate add to the bolt tension. A thin plate bends more, so the prying force is larger and the bolts can reach their tensile strength while the applied tension is still well below the bolts’ nominal capacity. The Manual procedure checks the bolt and the plate together through [mathin] \alpha’ [mathin], então [mathin] t_{min} [mathin] covers both.

What does alpha prime equal to 1 mean?

In the Manual Part 9 modelo, [mathin] \alpha’ [mathin] is the ratio of the plate moment at the bolt line to the plate moment at the face of the web, and it cannot exceed 1. The report caps it at 1 in the equation above. No [mathin] \alpha’ = 1 [mathin] the moments at the two lines are equal, which gives the largest [mathin] 1 + \delta \alpha’ [mathin] and so the thinnest [mathin] t_{min} [mathin] the procedure allows. Both fittings in this example reach that cap.

Is the column flange checked for prying too?

Sim. The column flange is clamped by the same bolts and bends in the same way, so SkyCiv runs the same procedure with the column’s [mathin] b [mathin], distância da borda, hole size and [mathin] F_{u} [mathin]. In this example it governs, even though its 0.71 in flange is thinner than the 0.75 in end plate by only 0.04 no.

Does shear on the bolts reduce the prying capacity?

Pode. [mathin] B [mathin] is the tension strength reduced for the shear on the same bolts, by AISC 360-16 J3.7. A lower [mathin] B [mathin] lowers [mathin] \beta [mathin], and once [mathin] \alpha’ [mathin] drops below 1 that raises [mathin] t_{min} [mathin]. In this example the 32 kip shear is small enough that [mathin] B [mathin] stays at the full [mathin] \phi F_{nt} A_{b} [mathin].

Check prying in your own connection

Choose an end plate, double angle or other tension connection in the calculadora de design de conexão gratuita, insira seus membros, bolts and axial load, and the bolt tension and prying checks are run for every fitting.

O módulo SkyCiv Connection Design fornece o relatório de cálculo completo com cada equação e seus números nele, para AISC 360-22 e AISC 360-16 (LRFD e ASD) e a norma AS 4100:2020. A calculadora de conexão de placa final, a calculadora de conexão de ângulo duplo quanto pelo calculadora de parafuso cover the connections where prying is checked. For bolt types and grades, Veja Bolts used in bolted connections, and for bolt groups in shear, Cálculo do grupo de parafusos usando ICOR.

Referências

Harold Munalem, Gerente de produto do SkyCiv Connection Design

Harold Munalem
gerente de produto, Connection Design
10+ anos em projetos de conexões de aço
LinkedIn

Como podemos ajudar?

×

Vá para o topo