Documentação SkyCiv

Seu guia para o software SkyCiv – tutoriais, guias de instruções e artigos técnicos

Design de conexão da Web soldada diretamente de canal a canal

To design a directly welded web connection between two channels to AISC 360, you check the fillet welds that join the beam web to the girder web against the beam end reaction. There is no plate and there are no bolts, so the design comes down to two things: a weld group that fits on the flat of the beam web and is at least the minimum size, and a weld that is strong enough once the base metal on both sides of it is accounted for.

Esta página funciona através de um exemplo do início ao fim: a C10x20 beam framing into the back of a C15x50 girder channel, com um 25 kip LRFD reaction carried by 1/4 in E70XX fillet welds on both sides of the beam web, projetado para AISC 360-16 e o Manual AISC 15ª Edição. Cada equação é escrita com seus números, na mesma ordem que a planilha de cálculo AISC, o SkyCiv Connection Design módulo produz para ele.

What is a channel to channel directly welded web connection?

It is a shear connection in which the end of a channel beam is welded straight to a channel girder, with no connecting element in between. The beam web butts against the girder and a fillet weld runs down each side of the beam web. It suits shop-assembled frames, platforms and secondary framing where channels are used for both members and a bolted field joint is not needed.

Este exemplo usa a orientação BBC, feixe para trás do canal. The beam frames to the flat back of the girder’s web, no lado afastado de seus flanges, so the beam needs no cope to clear them. A outra orientação, BFC (feixe para a frente do canal), coloca a viga entre os flanges da viga.

Elevation of a C10x20 beam welded to the back of a C15x50 channel with 1/4 in E70XX fillet welds on both sides

Elevação do relatório de cálculo: C10x20 beam welded to the back of a C15x50 girder channel

3D view of a C10x20 channel beam directly welded to the web of a C15x50 channel girder

3Vista D da conexão no SkyCiv Connection Design

Design de conexão web diretamente soldada: os passos em resumo

  1. Limites de detalhamento: check the minimum fillet weld size and that the welded depth fits on the flat of the beam web.
  2. Força de soldagem: find the largest weld the base metal can develop, the effective weld length, and the design strength of the two fillet welds.

Entradas de design para este exemplo

ItemSímboloValor
Resistência ao cisalhamento necessária (LRFD)[mathin] V_{u} [mathin]25 kip
BeamC10x20, ASTM A36
Profundidade do feixe / espessura da teia[mathin] d_{bm},\ t_{wb} [mathin]10 no / 0.379 no
Largura do flange da viga / grossura[mathin] b_{fb},\ t_{fb} [mathin]2.74 no / 0.436 no
Área do feixe[mathin] A_{bm} [mathin]10 em²
Rendimento do feixe / tensão de tração[mathin] F_{yb},\ F_{ub} [mathin]36 ksi / 58 ksi
VigaC15x50, ASTM A36
Profundidade da viga / espessura da teia[mathin] d_{sup},\ t_{ws} [mathin]15 no / 0.716 no
Largura do flange da viga / grossura[mathin] b_{fs},\ t_{fs} [mathin]3.72 no / 0.65 no
Área da viga[mathin] A_{sup} [mathin]14.7 em²
Rendimento da viga / tensão de tração[mathin] F_{ys},\ F_{us} [mathin]36 ksi / 58 ksi
Módulo de elasticidade[mathin] E [mathin]29000 ksi
SoldarSímboloValor
EletrodoE70XX
Filler metal classification strength[mathin] F_{EXX} [mathin]70 ksi
Fillet weld size, both sides of the beam web[mathin] W [mathin]1/4 no (0.25 no)
Welded depth[mathin] L_{d} [mathin]8 no

Passo 1: Limitações de detalhes de conexão (AISC 360-16 J2.2b)

The weld has to stay on the flat part of the beam web, clear of the flange-to-web fillets. The program takes the web lost at each flange as the larger of the design k distance and the cope depth. This beam has no copes, so each is 1 no.

[math] D_{max} = d_{det\_bm} – c_{t} – c_{b} = (10\ \text{in}) – (1\ \text{in}) – (1\ \text{in}) = 8\ \text{in} [math]

The welded depth of 8 in uses the full flat depth. The minimum fillet weld size of 3/16 in is the AISC 360-16 Table J2.4 value for the thinner part joined, a 0.379 em teia de feixe. A 4 in minimum connection depth is the software’s limit.

Limite de detalhamentoLimite (no)Real (no)DCRResultado
Tamanho mínimo de solda de filete0.1880.2500.750cdot K_a
Profundidade mínima de conexão4.0008.0000.500cdot K_a
Profundidade máxima de conexão8.0008.0001.000cdot K_a

DCR = 8 / 8 = 1.000 ≤ 1.0, OK

Passo 2: Design capacity of the weld (AISC 360-16 J2.4)

Limite do metal base no tamanho da solda (Eq Manual AISC. 9-2)

A fillet weld can be no stronger than the metal it is fused to. On the girder side the weld sits on the 0.716 na teia da viga. On the beam side the beam web carries a weld on each face, so each weld gets half of the 0.379 na web, 0.1895 no. The smaller of the two products governs, expressed as a weld size in sixteenths of an inch:

[math] D_{max} = \frac{\min\left(t_{ws} F_{us},\ \frac{t_{wb}}{2} F_{ub}\right)}{3.09\ \text{kip/in} \times F_{EXX}/F_{E70XX}} = \frac{\min\left((0.716\ \text{in})(58\ \text{ksi}),\ (0.1895\ \text{in})(58\ \text{ksi})\right)}{(3.09\ \text{kip/in}) \times (1)} = 3.557 [math]

The beam web governs. A weld of 3.557 sixteenths is [mathin] 3.557/16 = 0.222 [mathin] no, which is smaller than the 1/4 em solda, so the strength equation below uses the 0.222 in size the beam web can develop.

Comprimento efetivo de solda (Peça Manual AISC 10)

Each of the two welds runs the 8 in welded depth, less two weld sizes for the ends:

[math] L_{w} = 2 \left[ L_{d} – 2W \right] = 2 \times \left[ (8\ \text{in}) – 2 \times (0.25\ \text{in}) \right] = 15\ \text{in} [math]

Força de soldagem (Eq. J2-4)

Com [mathin] \phi = 0.75 [mathin] and the load parallel to the welds ([mathin] \theta_{u} = 0 [mathin]):

[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left(W,\ \frac{D_{max}}{16}\right) \left[1 + 0.5 \left(\sin \theta_{u}\right)^{1.5}\right] L_{w} [math]

[math] \phi R_{n} = (0.75) \times 0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left(0.25\ \text{in},\ \frac{3.557}{16}\right) \times \left[1 + 0.5 \times (\sin 0)^{1.5}\right] \times (15\ \text{in}) = 74.275\ \text{kip} [math]

[math] V_{u} = 25\ \text{kip} \le \phi R_{n} = 74.275\ \text{kip} [math]

DCR = 25 kip / 74.275 kip = 0.337 ≤ 1.0, OK

Resumo das verificações

VerificarDemandaCapacidadeDCRResultado
Limitações de detalhes de conexão8 no8 no1.000cdot K_a
**Design capacity of weld****25 kip****74.275 kip****0.337****PASSAR**

The connection passes both checks. A proporção de detalhamento de 1.000 is not a strength ratio: it shows that the 8 in weld uses the whole flat of the C10x20 web, which is the most this beam allows. The weld is the governing strength check at 0.337, and its strength is limited by the thin beam web rather than by the 1/4 in weld itself.

Auto Design is available for the channel to channel directly welded web connection. Ele altera as variáveis ​​de projeto da conexão até que cada verificação seja aprovada, e mantém seus membros e cargas conforme inseridos. Veja o Projeto Automático página para as preferências para as quais funciona.

O que mudar se uma verificação falhar

  • Profundidade máxima de conexão: the welded depth cannot be more than the flat of the beam web, aqui 8 no. If you need more weld, use a deeper beam or a connection with a plate or angles.
  • Tamanho mínimo de solda de filete: use at least the Table J2.4 minimum for the thinner part joined, aqui 3/16 no.
  • Força de soldagem: lengthen the weld up to the maximum depth first. A larger weld only helps until it reaches the base metal limit. In this example the beam web already limits the effective size to 0.222 no, então um 5/16 in weld would add no strength. Past that point, use a beam with a thicker web or a connection with a plate or angles.

Perguntas frequentes

Why is the effective weld size 0.222 in when the weld is 1/4 no?

Eq Manual AISC. 9-2 limits the weld to what the base metal can develop in shear. A teia do feixe é 0.379 in thick and has a weld on each face, so each weld is matched against half of it. That half-web can only develop a weld of 3.557 décimo sexto, 0.222 no, and the extra size of the 1/4 in weld is not counted.

Why is the weld length 15 in when the welded depth is 8 no?

There are two welds, um de cada lado da alma da viga. Each is 8 in long less two weld sizes for the ends, 7.5 no, so the total effective length is 15 no.

O que significa BBC?

BBC é transmitida para trás do canal. The beam frames to the flat back of the girder channel’s web, longe de suas flanges. No BFC, feixe para a frente do canal, as armações da viga entre os flanges da viga.

Is the girder web checked?

The girder web enters the design through the base metal check of Step 2, where its 0.716 in thickness is compared with the beam web’s half thickness. In this example the beam web is the weaker of the two, so it sets the weld strength.

Como isso mudaria para ASD em vez de LRFD?

As equações são as mesmas. The program uses the ASD safety factor in place of the LRFD resistance factor and compares the result with the ASD required strength.

Projete uma conexão web diretamente soldada gratuitamente

Cada número nesta página vem de uma solução. Pick the channel to channel category and the directly welded web configuration, entre no seu raio, viga, solda e reação, e veja cada uma dessas verificações em seu navegador. Não há nada para instalar.

O módulo SkyCiv Connection Design é o software de design de conexão por trás deste exemplo. Fornece o relatório de cálculo completo com todas as equações e seus números, como as etapas acima, além de todas as capacidades e DCR, para AISC 360-22 e AISC 360-16 (LRFD e ASD) e a norma AS 4100:2020. A calculadora de solda covers the weld checks on their own.

Referências

Harold Munalem, Gerente de produto do SkyCiv Connection Design

Harold Munalem
gerente de produto, Connection Design
10+ anos em projetos de conexões de aço
LinkedIn

Como podemos ajudar?

×

Vá para o topo