To design a bolted flange plate moment connection to a rectangular HSS column to AISC 360-16, you turn the beam moment into a tension and compression force in each flange, verifique as placas do flange, bolts and beam flanges for that force, and then check what the force does to the tube: the weld to the HSS face, local yielding of the plate on a flexible wall, and local yielding of the HSS sidewalls. A single plate on the beam web carries the shear.
This page works through one example: a W18x50 beam framing into the 4 in face of an HSS8x4x1/2 column, com 38 kip-ft de momento, 19 cisalhamento kip e 66 kip axial under LRFD, 3/4 in Grade 50 flange plates on four 1 em parafusos A490-SC cada, e uma 3/8 in A36 shear plate. Cada equação é escrita com seus números, na mesma ordem da planilha de cálculo, o SkyCiv Connection Design módulo produz para ele.
What is a flange plate moment connection to an HSS column?
A flange plate conexão de momento has one plate on the top flange and one on the bottom flange of the beam. Each plate is shop-welded to the column and field-bolted to the beam flange, so the moment passes through the plates as a tension and compression couple. A shear plate on the web takes the beam reaction. For a W-shape column the plates weld to the column flange, as in Como projetar uma conexão de momento de placa de flange.
On an HSS column the plates weld straight onto the tube wall, which is much more flexible than a column flange. A plate pulling on the middle of a thin wall cannot spread its force evenly across its width, so AISC reduces the plate to an effective width, and the sidewalls of the tube are checked for the force coming in from the corners. Those HSS checks are the part of the design this page adds to the W-shape example.
You can run this connection in the calculadora de conexão de placa de flange.

Elevação da conexão de exemplo. The flange plates are welded to the HSS face and bolted to the beam flanges; the shear plate carries the reaction.

Seção A-A, a plan cut through the top flange plate, showing the four bolts at a 3 5/8 in gage and the plate against the 4 in HSS face.

3Vista D da conexão no SkyCiv Connection Design.
How do you design a flange plate moment connection to an HSS column? As etapas em resumo
The report has two sections: the flange plates (Passos 1 para 14) and the shear plate (Passos 15 para 24).
- Limites de detalhamento no banzo da viga.
- Flange bolts in slip under the flange force.
- Bolt bearing on the flange plate.
- Bolt bearing on the beam flange.
- Cisalhamento em bloco da placa do flange.
- Cisalhamento em bloco do banzo da viga.
- Cedência de tensão e ruptura da placa do flange.
- Tension rupture of the beam flange.
- Ruptura por flexão da viga nos furos dos parafusos do flange.
- Compression of the flange plate.
- Detailing limit at the HSS face.
- Fillet weld from the flange plate to the HSS face.
- Local yielding of the flange plate on the HSS wall.
- Local yielding of the HSS sidewalls.
- Detailing limits of the shear plate at the beam.
- Shear plate bolt group.
- Bearing on the shear plate.
- Rolamento na teia da viga.
- Resistência efetiva do grupo de parafusos de alma.
- Block shear of the shear plate.
- Shear yielding and rupture of the shear plate.
- Detailing limits of the shear plate at the HSS wall.
- Weld from the shear plate to the HSS wall.
- Perfuração de parede HSS.
Entradas de design para este exemplo
O código de projeto é AISC 360-16 LRFD. As propriedades da seção são do Manual AISC. How the loads are entered is explained in cargas e combinações de carga.
| Item | Símbolo | Valor |
|---|---|---|
| Factored moment (eixo forte) | [mathin] M_{ux} [mathin] | 38 kip-ft |
| Cisalhamento fatorado | [mathin] V_{u} [mathin] | 19 kip |
| Tensão axial fatorada / compressão | [mathin] T_{u},\ C_{u} [mathin] | 66 kip / 66 kip |
| Beam | Momento da carga ao vivo, ASTM A992 | |
| Profundidade do feixe / espessura da teia | [mathin] d_{bm},\ t_{wb} [mathin] | 18 no / 0.355 no |
| Largura do flange da viga / grossura | [mathin] b_{fb},\ t_{fb} [mathin] | 7.5 no / 0.57 no |
| Área do feixe / colheita / resistência à tracção | [mathin] A,\ F_{yb},\ F_{ub} [mathin] | 14.7 em² / 50 ksi / 65 ksi |
| Coluna | HSS8x4x1/2, ASTM A500 gr. C | |
| Width of the HSS face the plates weld to | [mathin] b [mathin] | 4 no |
| Profundidade HSS / projetar espessura da parede | [mathin] h,\ t [mathin] | 8 no / 0.465 no |
| Workable flat of the face | [mathin] W_{flat} [mathin] | 2.875 no |
| Rendimento da coluna / resistência à tracção | [mathin] F_{ys},\ F_{us} [mathin] | 50 ksi / 62 ksi |
| Flange plate item | Símbolo | Valor |
|---|---|---|
| Placas de flange | PT 3/4 x 6 1/2 x 6 1/2, ASTM A572 Gr. 50 (50 / 65 ksi) | |
| Largura da placa / comprimento / grossura | [mathin] b_{fp},\ L_{fp},\ t_{fp} [mathin] | 6.5 no / 6.5 no / 0.75 no |
| Parafusos de flange | 1 em A490-SC, Classe A, 1 plano de cisalhamento | |
| Buracos | Placa de flange: superdimensionado (OVS). Flange de viga: padrão (DST) | |
| Linhas de parafuso / calibrar | [mathin] n_{r},\ g_{a} [mathin] | 2 / 3.625 no |
| Bolts per line / espaçamento | [mathin] n_{c},\ s_{c} [mathin] | 2 / 3 no |
| Distâncias da borda da placa, entre / ao longo do feixe | [mathin] L_{ev\_fp},\ L_{eh\_fp} [mathin] | 1.4375 no / 1.5 no |
| Beam flange edge distances, entre / ao longo | [mathin] L_{ev\_bf},\ L_{eh\_bf} [mathin] | 1.9375 no / 1.5 no |
| Erection gap | 1/4 no | |
| Weld to HSS face | 1/2 em filé, E70XX |
| Shear plate item | Símbolo | Valor |
|---|---|---|
| Shear plate | PT 3/8 x 3 1/2 x 9, ASTM A36 (36 / 58 ksi) | |
| Parafusos de teia | 1 em A490-N, tópicos incluídos | |
| Buracos | Prato: horizontal com fenda curta (HSSL). Teia de feixe: padrão (DST) | |
| Linhas de parafusos / espaçamento / colunas | [mathin] n_{r},\ s_{r},\ n_{c} [mathin] | 3 / 3 no / 1 |
| Edge distances / weld to bolt line | [mathin] L_{e},\ a [mathin] | 1.5 no / 2 no |
| Weld to HSS face | 3/16 em filé dos dois lados, E70XX |
Flange plate section
Passo 1: Limites de detalhamento no banzo da viga (AISC 360-16 J3.3, J3.4)
The bolt gage across the flange, the spacing along it and the edge distances on both the plate and the beam flange are checked against the J3.3 and Table J3.4 limits for a 1 em parafuso, with the oversized-hole increment on the plate.
| Limite de detalhamento | Limite (no) | Real (no) | DCR | Resultado |
|---|---|---|---|---|
| Medidor mínimo | 3.625 | 3.625 | 1.000 | cdot K_a |
| Espaçamento mínimo entre colunas de parafusos | 2.667 | 3.000 | 0.889 | cdot K_a |
| Espaçamento máximo entre colunas de parafusos | 6.000 | 3.000 | 0.500 | cdot K_a |
| Distância mínima da borda vertical da placa | 1.375 | 1.438 | 0.956 | cdot K_a |
| Distância mínima da borda horizontal da placa | 1.375 | 1.500 | 0.917 | cdot K_a |
| Distância mínima da borda vertical do flange da viga | 1.250 | 1.938 | 0.645 | cdot K_a |
| Distância mínima da borda horizontal do flange da viga | 1.250 | 1.500 | 0.833 | cdot K_a |
The gage equals the module’s minimum gage, so that row sits at exactly 1.000:
[math] DCR = \frac{3.625\,in}{3.625\,in} = 1.000 [math]
DCR = 1.000, OK
Passo 2: Flange bolts in slip under the flange force (AISC 360-16 J3.8)
The moment becomes a force in each flange over the distance between flange centers, and half the axial force is added to it:
[math] P_{uF} = \frac{M_{ux}}{d_{bm} – t_{fb}} + \frac{P_{u}}{2} = \frac{38\,kip\text{-}ft}{18\,in – 0.57\,in} + \frac{66\,kip}{2} = 59.162\,kip [math]
This flange force is the demand for every check in the flange plate section. The four bolts are slip-critical, Eq. J3-4, with the report’s filler factor of 0.85:
[math] \phi R_{n} = \phi\, \mu\, D_{u}\, h_{f}\, T_{b}\, N_{s}\, n_{r}\, n_{c} = (0.85) \times (0.3) \times (1.13) \times (0.85) \times (64\,kip) \times (1) \times (2) \times (2) = 62.701\,kip [math]
DCR = 59.162 kip / 62.701 kip = 0.944 < 1.0, OK
Passo 3: Bolt bearing on the flange plate (AISC 360-16 J3.10)
The force runs along the beam, so the bolts bear toward the plate end. Com o 1.25 in oversized hole:
[math] l_{c1} = 1.5 – \frac{1.25}{2} = 0.875\,in, \qquad l_{c2} = 3 – 1.25 = 1.75\,in [math]
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.875, 2.4) \times 0.75 \times 65 \times 2 + \min(1.2 \times 1.75, 2.4) \times 0.75 \times 65 \times 2 \times 1 \right] = 230.34\,kip [math]
DCR = 59.162 kip / 230.34 kip = 0.257 < 1.0, OK
Passo 4: Bolt bearing on the beam flange (AISC 360-16 J3.10)
[math] l_{c1} = 1.5 – \frac{1.125}{2} = 0.9375\,in, \qquad l_{c2} = 1.875\,in [math]
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.57 \times 65 \times 2 + \min(1.2 \times 1.875, 2.4) \times 0.57 \times 65 \times 2 \times 1 \right] = 187.57\,kip [math]
DCR = 59.162 kip / 187.57 kip = 0.315 < 1.0, OK
Passo 5: Cisalhamento em bloco da placa do flange (AISC 360-16 J4.3)
Three tear-out shapes are checked, all with [mathin] U_{bs} = 1 [mathin] Estimativa da capacidade da pilha. J4-5:
[math] \phi R_{n} = \phi \left( 0.6 F_{up} A_{nv} + U_{bs} F_{up} A_{nt} \le 0.6 F_{yp} A_{gv} + U_{bs} F_{up} A_{nt} \right) [math]
| Padrão | Agv (em²) | Anv (em²) | Ant (em²) | phi Rn (kip) |
|---|---|---|---|---|
| L: um plano de cisalhamento, tensão através dos parafusos até uma borda | 3.375 | 1.8984 | 2.3203 | 168.64 |
| você: dois planos de cisalhamento, tensão entre as linhas dos parafusos | 6.75 | 3.7969 | 1.7344 | 195.61 |
| 2L: dois planos de cisalhamento, tensão de cada linha de parafuso até sua borda | 6.75 | 3.7969 | 1.1719 | 168.19 |
For the governing 2L pattern:
[math] A_{nt} = 2 \times 0.75 \left[ 1.4375 – 0.5 \times (1.25 + 0.0625) \right] = 1.1719\,in^{2} [math]
[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.7969 + 65 \times 1.1719 \le 0.6 \times 50 \times 6.75 + 65 \times 1.1719 \right) = 168.19\,kip [math]
DCR = 59.162 kip / 168.19 kip = 0.352 < 1.0, OK
Passo 6: Cisalhamento em bloco do banzo da viga (AISC 360-16 J4.3)
The beam flange tears out as two outer strips:
[math] A_{nt} = 0.57 \left[ 7.5 – 3.625 – 1 \times (1.1875) \right] = 1.5319\,in^{2} [math]
[math] A_{gv} = 2 \times 0.57 \left[ 1.5 + 3 \right] = 5.13\,in^{2}, \qquad A_{nv} = 2 \times 0.57 \left( 4.5 – 1.5 \times 1.1875 \right) = 3.0994\,in^{2} [math]
[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.0994 + 65 \times 1.5319 \le 0.6 \times 50 \times 5.13 + 65 \times 1.5319 \right) = 165.34\,kip [math]
DCR = 59.162 kip / 165.34 kip = 0.358 < 1.0, OK
Passo 7: Cedência de tensão e ruptura da placa do flange (AISC 360-16 J4.1)
[math] \phi R_{n\_ty} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]
[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.75 \left[ 6.5 – 2 \times (1.3125) \right] = 141.68\,kip [math]
DCR = 59.162 kip / 141.68 kip = 0.418 < 1.0, OK
Passo 8: Tension rupture of the beam flange (AISC 360-16 D3, J4.1)
The flange force is taken by half the beam’s area, less the two flange holes, with the shear lag factor U = 0.283 from Table D3.1 case 2:
[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.283 \left[ 0.5 \times 14.7 – 2 \times (1.1875) \times 0.57 \right] = 82.726\,kip [math]
DCR = 59.162 kip / 82.726 kip = 0.715 < 1.0, OK
Passo 9: Ruptura por flexão da viga nos furos dos parafusos do flange (AISC 360-16 F13.1)
[math] A_{fg} = 7.5 \times 0.57 = 4.275\,in^{2}, \qquad A_{fn} = 4.275 – 2 \times (1.1875) \times 0.57 = 2.9213\,in^{2} [math]
With Fy / Fu = 0.76923, não mais que 0.8, Yt = 1. Então:
[math] F_{u} A_{fn} = 189.88\,kip \lt Y_{t} F_{y} A_{fg} = 213.75\,kip [math]
so the holes reduce the flexural strength and Eq. F13-1 applies, with the beam’s elastic modulus of 89.005 em³:
[math] M_{n} = \frac{F_{ub} A_{fn}}{A_{fg}}\, S_{x} = \frac{65 \times 2.9213}{4.275} \times 89.005 = 329.44\,kip\text{-}ft [math]
[math] \phi R_{n} = \frac{0.9\, M_{n}}{d_{bm} – t_{fb}} = \frac{0.9 \times 329.44\,kip\text{-}ft}{18\,in – 0.57\,in} = 204.13\,kip [math]
DCR = 59.162 kip / 204.13 kip = 0.290 < 1.0, OK
Passo 10: Compression of the flange plate (AISC 360-16 J4.4)
KL/r of the plate is no more than 25, então equação. J4-6 applies with no buckling reduction:
[math] \phi R_{n} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]
DCR = 59.162 kip / 219.38 kip = 0.270 < 1.0, OK
Passo 11: Detailing limit at the HSS face
| Limite de detalhamento | Limite (no) | Real (no) | DCR | Resultado |
|---|---|---|---|---|
| Tamanho máximo de solda de ângulo por folga da viga | 0.500 | 0.500 | 1.000 | cdot K_a |
A 1/2 in weld exactly fills the available clearance, o que é permitido:
DCR = 1.000, OK
Passo 12: Fillet weld from the flange plate to the HSS face (AISC 360-16 K1, K5, J2.4)
This is where the HSS changes the design. The base metal limit first, from Manual Eq. 9-2:
[math] D_{max} = \frac{(0.375)(65) \le (0.465)(62)}{3.09} = 7.8883 [math]
A 6.5 na placa é mais largo que o 4 in HSS face. The report allows that, but only the width over the face delivers load into it:
[math] B_{p,eff} = b_{fp} \le b = \min(6.5\,in, 4\,in) = 4\,in [math]
Eq. K1-1 then reduces it to the effective width:
[math] B_{e} = \left( \frac{10 t}{b} \right) \left( \frac{F_{ys}\, t}{F_{yp}\, t_{fp}} \right) B_{p,eff} \le B_{p,eff} = \left( \frac{10 \times 0.465}{4} \right) \left( \frac{50 \times 0.465}{50 \times 0.75} \right) \times 4 = 2.883\,in [math]
Per K5 the effective weld length is 2Be, and the report also caps Be at the workable flat:
[math] L_{w} = 2 \left( B_{e} \le W_{flat} \right) = 2 \times \min(2.883, 2.875) = 5.75\,in [math]
[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.5, \frac{7.8883}{16}\right) \times 5.75 = 63.144\,kip [math]
DCR = 59.162 kip / 63.144 kip = 0.937 < 1.0, OK
Passo 13: Local yielding of the flange plate on the HSS wall (AISC 360-16 K1, Guia de projeto 24)
The same effective width idea limits the force the plate can deliver into the wall. The report uses φ = 0.95 from AISC Design Guide 24, Tabela 7-2:
[math] \phi R_{n} = \phi \left( \frac{10\, t^{2}\, F_{ys}\, B_{p,eff}}{b} \le F_{yp}\, t_{fp}\, B_{p,eff} \right) = 0.95 \times \min\left( \frac{10 \times 0.465^{2} \times 50 \times 4}{4},\; 50 \times 0.75 \times 4 \right) = 102.71\,kip [math]
DCR = 59.162 kip / 102.71 kip = 0.576 < 1.0, OK
Passo 14: Local yielding of the HSS sidewalls
The flange force also reaches the two sidewalls of the tube through the corners. The report checks them with the expression below and φ = 1.0, without citing a clause, so it is the software’s limit for this check:
[math] \phi R_{n} = \phi \times 2 F_{ys}\, t \left[ 5 (1.5 t) + t_{fp} \right] = 1.0 \times 2 \times 50 \times 0.465 \left[ 5 \times (1.5 \times 0.465) + 0.75 \right] = 197.04\,kip [math]
DCR = 59.162 kip / 197.04 kip = 0.300 < 1.0, OK
Shear plate section
The shear plate is a conventional single plate welded to the HSS face and carries the 19 reação kip. Its checks follow the shear tab procedure, worked in full in Como projetar uma conexão de cisalhamento de placa única, with the HSS face checks added.
Passo 15: Detailing limits of the shear plate at the beam (AISC 360-16 J3.3, J3.4)
| Limite de detalhamento | Limite (no) | Real (no) | DCR | Resultado |
|---|---|---|---|---|
| Espaçamento mínimo entre linhas de parafusos | 2.667 | 3.000 | 0.889 | cdot K_a |
| Espaçamento máximo entre linhas de parafusos | 6.000 | 3.000 | 0.500 | cdot K_a |
| Distância mínima da borda vertical da placa | 1.250 | 1.500 | 0.833 | cdot K_a |
| Distância mínima da borda horizontal da placa | 1.375 | 1.500 | 0.917 | cdot K_a |
| Distância mínima da borda horizontal do feixe | 1.250 | 1.500 | 0.833 | cdot K_a |
| Profundidade mínima de conexão | 7.750 | 9.000 | 0.861 | cdot K_a |
| Profundidade máxima de conexão | 16.000 | 9.000 | 0.563 | cdot K_a |
[math] DCR = \frac{1.375\,in}{1.5\,in} = 0.917 [math]
DCR = 0.917 < 1.0, OK
Passo 16: Shear plate bolt group (AISC 360-16 J3.6)
No fillers, então [mathin] h_{f} = 1 [mathin] by J5.2(uma). The report uses C = 3 for the three web bolts:
[math] \phi R_{n} = 0.75 \times 68 \times \frac{\pi}{4} (1\,in)^{2} \times (1) \times (3) \times (1) = 120.17\,kip [math]
DCR = 19 kip / 120.17 kip = 0.158 < 1.0, OK
Passo 17: Bearing and tear-out on the shear plate (AISC 360-16 J3.10)
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.375 \times 58 + \min(1.2 \times 1.875, 2.4) \times 0.375 \times 58 \times 2 \right] \times \frac{3}{3} = 91.758\,kip [math]
DCR = 19 kip / 91.758 kip = 0.207 < 1.0, OK
Passo 18: Bearing and tear-out on the beam web (AISC 360-16 J3.10)
[math] \phi R_{n} = (0.75) \times \min(1.2 \times 1.875, 2.4) \times (0.355\,in) \times (65\,ksi) \times (3) = 116.82\,kip [math]
DCR = 19 kip / 116.82 kip = 0.163 < 1.0, OK
Passo 19: Resistência efetiva do grupo de parafusos de alma (AISC 360-16 Comentário J3.6)
Por parafuso: o cisalhamento 40.055 kip, plate edge bolt 18.352 kip, plate inner bolt 36.703 kip and beam web 38.939 kip. Parafusos 1 e 2 take the inner-bolt value and bolt 3 the edge value:
[math] \Sigma \phi r_{eff} = 2 \times (36.703\,kip) + 18.352\,kip = 91.758\,kip, \qquad \phi R_{n,eff} = 91.758 \times \frac{3}{3} = 91.758\,kip [math]
DCR = 19 kip / 91.758 kip = 0.207 < 1.0, OK
Passo 20: Block shear of the shear plate (AISC 360-16 J4.3)
[math] A_{nt} = 0.30469\,in^{2}, \quad A_{gv} = 2.8125\,in^{2}, \quad A_{nv} = 1.6992\,in^{2} [math]
[math] \phi R_{n} = 0.75 \left( 0.6 \times 58 \times 1.6992 + 58 \times 0.30469 \le 0.6 \times 36 \times 2.8125 + 58 \times 0.30469 \right) = 57.604\,kip [math]
DCR = 19 kip / 57.604 kip = 0.330 < 1.0, OK
Passo 21: Shear yielding and rupture of the shear plate (AISC 360-16 J4.2)
[math] \phi R_{n\_sy} = 1.0 \times 0.6 \times 36 \times 3.375 = 72.9\,kip, \qquad \phi R_{n\_sr} = 0.75 \times 0.6 \times 58 \times 2.0391 = 53.22\,kip [math]
DCR = 19 kip / 53.22 kip = 0.357 < 1.0, OK
Passo 22: Detailing limits of the shear plate at the HSS wall
Os valores de planicidade trabalhável e esbelteza são os limites do módulo para uma única placa em uma parede HSS.
| Limite de detalhamento | Limite (no) | Real (no) | DCR | Resultado |
|---|---|---|---|---|
| Tamanho máximo de solda de ângulo por folga da viga | 0.500 | 0.188 | 0.376 | cdot K_a |
| Tamanho máximo de solda de filete por plano trabalhável HSS | 0.885 | 0.188 | 0.212 | cdot K_a |
| Esbeltez máxima da parede HSS b/t | 33.716 | 5.602 | 0.166 | cdot K_a |
DCR = 0.376 < 1.0, OK
Passo 23: Weld from the shear plate to the HSS wall (AISC 360-16 J2.4)
[math] D_{max} = \frac{(0.1875)(58) \le (0.465)(62)}{3.09} = 3.5194, \qquad L_{w} = 2 \left[ 9 – 2 \times 0.1875 \right] = 17.25\,in [math]
[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.1875, \frac{3.5194}{16}\right) \times \left[ 1 + 0.5 \sin^{1.5}(0) \right] \times 17.25 = 72.042\,kip [math]
DCR = 19 kip / 72.042 kip = 0.264 < 1.0, OK
Passo 24: Perfuração de parede HSS (Eq Manual AISC. 10-7b, página 10-153)
[math] \phi R_{n} = \frac{0.75 \times 62 \times 0.465 \times 9^{2}}{5 \times 2} = 175.14\,kip [math]
DCR = 19 kip / 175.14 kip = 0.108 < 1.0, OK
Resumo das verificações de projeto
| Verificação de projeto | Demanda | Capacidade | DCR | Resultado |
|---|---|---|---|---|
| A Especificação Nacional de Design: detailing at beam | 3.625 em calibre | 3.625 em minutos | 1.000 | cdot K_a |
| Flange bolts in slip | 59.162 kip | 62.701 kip | 0.944 | cdot K_a |
| Rolamento na placa do flange | 59.162 kip | 230.34 kip | 0.257 | cdot K_a |
| Rolamento no flange da viga | 59.162 kip | 187.57 kip | 0.315 | cdot K_a |
| Cisalhamento de bloco, placa de flange | 59.162 kip | 168.19 kip | 0.352 | cdot K_a |
| Cisalhamento de bloco, flange de viga | 59.162 kip | 165.34 kip | 0.358 | cdot K_a |
| Tensão da placa do flange | 59.162 kip | 141.68 kip | 0.418 | cdot K_a |
| Beam flange tension rupture | 59.162 kip | 82.726 kip | 0.715 | cdot K_a |
| Beam flexural rupture at holes | 59.162 kip | 204.13 kip | 0.290 | cdot K_a |
| Compressão da placa de flange | 59.162 kip | 219.38 kip | 0.270 | cdot K_a |
| A Especificação Nacional de Design: detailing at HSS face | 0.5 em solda | 0.5 no máximo | 1.000 | cdot K_a |
| Flange plate weld to HSS | 59.162 kip | 63.144 kip | 0.937 | cdot K_a |
| Flange plate local yielding | 59.162 kip | 102.71 kip | 0.576 | cdot K_a |
| HSS sidewall local yielding | 59.162 kip | 197.04 kip | 0.300 | cdot K_a |
| Shear plate: detailing at beam | 1.375 em minutos | 1.5 in edge | 0.917 | cdot K_a |
| Shear plate bolt group | 19 kip | 120.17 kip | 0.158 | cdot K_a |
| Bearing on shear plate | 19 kip | 91.758 kip | 0.207 | cdot K_a |
| Rolamento na teia do feixe | 19 kip | 116.82 kip | 0.163 | cdot K_a |
| Effective web bolt group strength | 19 kip | 91.758 kip | 0.207 | cdot K_a |
| Cisalhamento de bloco, shear plate | 19 kip | 57.604 kip | 0.330 | cdot K_a |
| Cedência por cisalhamento e ruptura, shear plate | 19 kip | 53.22 kip | 0.357 | cdot K_a |
| Shear plate: detailing at HSS wall | 0.188 em solda | 0.5 no máximo | 0.376 | cdot K_a |
| Shear plate weld to HSS | 19 kip | 72.042 kip | 0.264 | cdot K_a |
| Perfuração de parede HSS | 19 kip | 175.14 kip | 0.108 | cdot K_a |
A conexão passa em todas as verificações. The two ratios at 1.000 are detailing limits that the layout meets exactly. Das verificações de força, the flange bolts in slip govern at 0.944, followed closely by the flange plate weld to the HSS face at 0.937. The weld is limited by the HSS: só 2.883 dentro do 6.5 in plate counts as effective width, and the weld length is capped at the 2.875 in workable flat of the 4 in face.
O que mudar se uma verificação falhar
- Flange bolts in slip: add bolts along the beam, use um parafuso maior, or a Class B faying surface. A deeper beam lowers the flange force for the same moment.
- Flange plate weld to the HSS: a thicker HSS wall raises Be, since Be grows with the square of the wall thickness, and a wider tube face gives a longer workable flat. A thicker flange plate lowers Be, so do not thicken the plate to fix this check.
- Flange plate local yielding or HSS sidewall yielding: use a thicker-walled tube.
- Beam flange tension rupture or flexural rupture: reduce the holes in the flange or use a heavier beam.
- Block shear or plate tension: increase the edge distances, the bolt spacing or the plate thickness.
- Shear plate checks: as for a shear tab, add a bolt row or make the plate deeper.
Auto Design is available for the flange plate moment connection to an HSS column. Ele muda os parafusos, plates and welds until every check passes, e mantém seus membros e cargas conforme inseridos. Veja o Projeto Automático página para as preferências para as quais funciona.
Perguntas frequentes
How is this different from a flange plate connection to a W-shape column?
The beam side checks, Passos 1 para 10, are the same as in Como projetar uma conexão de momento de placa de flange. The difference is at the column. On a W-shape column the plates weld to a thick flange backed by the column web. An HSS face is a thin wall between the corners, so the flange plate is reduced to an effective width for the weld and for plate local yielding, and the tube sidewalls are checked for local yielding.
Por que é que 6.5 in flange plate wider than the 4 in HSS face?
The plate is sized to bolt to the 7.5 in beam flange at a 3.625 em calibre, which needs more width than the tube face has. The report allows a plate wider than the face, but only the 4 in over the face counts when the force goes into the HSS.
What is the effective width Be?
Eq. K1-1 reduces a plate welded across an HSS face to the width that is effective in carrying load into the wall. It depends on the wall slenderness b/t and on the ratio of wall to plate strength and thickness. Here Be = 2.883 dentro do 4 in effective plate width.
Why is the flange force 59.162 kip?
A 38 kip-ft moment is divided by the distance between flange centers, 17.43 no, dando 26.162 kip, and half of the 66 kip axial force is added to each flange. The report uses this one flange force for every check in the flange plate section.
Does this example follow the AISC 15th or 16th edition Manual?
Segue AISC 360-16 with the AISC Manual 15th Edition and AISC Design Guide 24 for the HSS plate local yielding factor. Clause and page references move in the 16th Edition Manual and AISC 360-22, então compare-os com a edição que seu projeto usa.
Design a flange plate moment connection to an HSS column for free
Cada número nesta página vem de uma solução. Pick the flange plate moment connection to an HSS column, entre no seu raio, tubo, placas, parafusos e cargas, e veja cada uma dessas verificações em seu navegador. Não há nada para instalar.
O módulo SkyCiv Connection Design é o software de design de conexão por trás deste exemplo. Fornece o relatório de cálculo completo com todas as equações e seus números, como as etapas acima, além de todas as capacidades e DCR, para AISC 360-22 e AISC 360-16 (LRFD e ASD) e a norma AS 4100:2020. A calculadora de parafuso e calculadora de solda cubra o grupo de parafusos e verifique a soldagem por conta própria.
Referências
- AISC 360-16, Especificação para Edifícios de Aço Estrutural: D3 (Tabela D3.1), F13.1 (Eq. F13-1), J2.4 (Eq. J2-4), J3.3, J3.4 (Tabela J3.4), J3.6 (Eq. J3-1) e Comentário, J3.8 (Eq. J3-4), J3.10 (Eq. J3-6a, J3-6c), J4.1 (Eq. J4-1, J4-2), J4.2 (Eq. J4-3, J4-4), J4.3 (Eq. J4-5), J4.4 (Eq. J4-6), J5.2(uma), K1 (Eq. K1-1, K1-2), K5.
- Manual de construção em aço AISC, 15ª edição: Parte 9, Eq. 9-2; Parte 10, Eq. 10-7b (página 10-153).
- Guia de projeto AISC 24, Hollow Structural Section Connections: Tabela 7-2.
- Como projetar uma conexão de momento de placa de flange (Coluna em forma de W)
- Como projetar uma conexão de cisalhamento de placa única
- Dimensionamento de ligações metálicas utilizando AISC 360-16
Harold Munalem
gerente de produto, Connection Design
10+ anos em projetos de conexões de aço
LinkedIn