Documentação SkyCiv

Seu guia para o software SkyCiv – tutoriais, guias de instruções e artigos técnicos

Conexão do momento da placa do flange ao projeto da coluna HSS

To design a bolted flange plate moment connection to a rectangular HSS column to AISC 360-16, you turn the beam moment into a tension and compression force in each flange, verifique as placas do flange, bolts and beam flanges for that force, and then check what the force does to the tube: the weld to the HSS face, local yielding of the plate on a flexible wall, and local yielding of the HSS sidewalls. A single plate on the beam web carries the shear.

This page works through one example: a W18x50 beam framing into the 4 in face of an HSS8x4x1/2 column, com 38 kip-ft de momento, 19 cisalhamento kip e 66 kip axial under LRFD, 3/4 in Grade 50 flange plates on four 1 em parafusos A490-SC cada, e uma 3/8 in A36 shear plate. Cada equação é escrita com seus números, na mesma ordem da planilha de cálculo, o SkyCiv Connection Design módulo produz para ele.

What is a flange plate moment connection to an HSS column?

A flange plate conexão de momento has one plate on the top flange and one on the bottom flange of the beam. Each plate is shop-welded to the column and field-bolted to the beam flange, so the moment passes through the plates as a tension and compression couple. A shear plate on the web takes the beam reaction. For a W-shape column the plates weld to the column flange, as in Como projetar uma conexão de momento de placa de flange.

On an HSS column the plates weld straight onto the tube wall, which is much more flexible than a column flange. A plate pulling on the middle of a thin wall cannot spread its force evenly across its width, so AISC reduces the plate to an effective width, and the sidewalls of the tube are checked for the force coming in from the corners. Those HSS checks are the part of the design this page adds to the W-shape example.

You can run this connection in the calculadora de conexão de placa de flange.

Elevação: W18x50 beam with bolted top and bottom flange plates and a shear plate, welded to an HSS8x4x1/2 column

Elevação da conexão de exemplo. The flange plates are welded to the HSS face and bolted to the beam flanges; the shear plate carries the reaction.

Plan section A-A of the 3/4 em x 6 1/2 in flange plate with four 1 em parafusos A490-SC, welded to the 4 in HSS face

Seção A-A, a plan cut through the top flange plate, showing the four bolts at a 3 5/8 in gage and the plate against the 4 in HSS face.

3D view of the flange plate moment connection: W18x50 beam framing into a rectangular HSS8x4x1/2 column

3Vista D da conexão no SkyCiv Connection Design.

How do you design a flange plate moment connection to an HSS column? As etapas em resumo

The report has two sections: the flange plates (Passos 1 para 14) and the shear plate (Passos 15 para 24).

  1. Limites de detalhamento no banzo da viga.
  2. Flange bolts in slip under the flange force.
  3. Bolt bearing on the flange plate.
  4. Bolt bearing on the beam flange.
  5. Cisalhamento em bloco da placa do flange.
  6. Cisalhamento em bloco do banzo da viga.
  7. Cedência de tensão e ruptura da placa do flange.
  8. Tension rupture of the beam flange.
  9. Ruptura por flexão da viga nos furos dos parafusos do flange.
  10. Compression of the flange plate.
  11. Detailing limit at the HSS face.
  12. Fillet weld from the flange plate to the HSS face.
  13. Local yielding of the flange plate on the HSS wall.
  14. Local yielding of the HSS sidewalls.
  15. Detailing limits of the shear plate at the beam.
  16. Shear plate bolt group.
  17. Bearing on the shear plate.
  18. Rolamento na teia da viga.
  19. Resistência efetiva do grupo de parafusos de alma.
  20. Block shear of the shear plate.
  21. Shear yielding and rupture of the shear plate.
  22. Detailing limits of the shear plate at the HSS wall.
  23. Weld from the shear plate to the HSS wall.
  24. Perfuração de parede HSS.

Entradas de design para este exemplo

O código de projeto é AISC 360-16 LRFD. As propriedades da seção são do Manual AISC. How the loads are entered is explained in cargas e combinações de carga.

ItemSímboloValor
Factored moment (eixo forte)[mathin] M_{ux} [mathin]38 kip-ft
Cisalhamento fatorado[mathin] V_{u} [mathin]19 kip
Tensão axial fatorada / compressão[mathin] T_{u},\ C_{u} [mathin]66 kip / 66 kip
BeamMomento da carga ao vivo, ASTM A992
Profundidade do feixe / espessura da teia[mathin] d_{bm},\ t_{wb} [mathin]18 no / 0.355 no
Largura do flange da viga / grossura[mathin] b_{fb},\ t_{fb} [mathin]7.5 no / 0.57 no
Área do feixe / colheita / resistência à tracção[mathin] A,\ F_{yb},\ F_{ub} [mathin]14.7 em² / 50 ksi / 65 ksi
ColunaHSS8x4x1/2, ASTM A500 gr. C
Width of the HSS face the plates weld to[mathin] b [mathin]4 no
Profundidade HSS / projetar espessura da parede[mathin] h,\ t [mathin]8 no / 0.465 no
Workable flat of the face[mathin] W_{flat} [mathin]2.875 no
Rendimento da coluna / resistência à tracção[mathin] F_{ys},\ F_{us} [mathin]50 ksi / 62 ksi
Flange plate itemSímboloValor
Placas de flangePT 3/4 x 6 1/2 x 6 1/2, ASTM A572 Gr. 50 (50 / 65 ksi)
Largura da placa / comprimento / grossura[mathin] b_{fp},\ L_{fp},\ t_{fp} [mathin]6.5 no / 6.5 no / 0.75 no
Parafusos de flange1 em A490-SC, Classe A, 1 plano de cisalhamento
BuracosPlaca de flange: superdimensionado (OVS). Flange de viga: padrão (DST)
Linhas de parafuso / calibrar[mathin] n_{r},\ g_{a} [mathin]2 / 3.625 no
Bolts per line / espaçamento[mathin] n_{c},\ s_{c} [mathin]2 / 3 no
Distâncias da borda da placa, entre / ao longo do feixe[mathin] L_{ev\_fp},\ L_{eh\_fp} [mathin]1.4375 no / 1.5 no
Beam flange edge distances, entre / ao longo[mathin] L_{ev\_bf},\ L_{eh\_bf} [mathin]1.9375 no / 1.5 no
Erection gap1/4 no
Weld to HSS face1/2 em filé, E70XX
Shear plate itemSímboloValor
Shear platePT 3/8 x 3 1/2 x 9, ASTM A36 (36 / 58 ksi)
Parafusos de teia1 em A490-N, tópicos incluídos
BuracosPrato: horizontal com fenda curta (HSSL). Teia de feixe: padrão (DST)
Linhas de parafusos / espaçamento / colunas[mathin] n_{r},\ s_{r},\ n_{c} [mathin]3 / 3 no / 1
Edge distances / weld to bolt line[mathin] L_{e},\ a [mathin]1.5 no / 2 no
Weld to HSS face3/16 em filé dos dois lados, E70XX

Flange plate section

Passo 1: Limites de detalhamento no banzo da viga (AISC 360-16 J3.3, J3.4)

The bolt gage across the flange, the spacing along it and the edge distances on both the plate and the beam flange are checked against the J3.3 and Table J3.4 limits for a 1 em parafuso, with the oversized-hole increment on the plate.

Limite de detalhamentoLimite (no)Real (no)DCRResultado
Medidor mínimo3.6253.6251.000cdot K_a
Espaçamento mínimo entre colunas de parafusos2.6673.0000.889cdot K_a
Espaçamento máximo entre colunas de parafusos6.0003.0000.500cdot K_a
Distância mínima da borda vertical da placa1.3751.4380.956cdot K_a
Distância mínima da borda horizontal da placa1.3751.5000.917cdot K_a
Distância mínima da borda vertical do flange da viga1.2501.9380.645cdot K_a
Distância mínima da borda horizontal do flange da viga1.2501.5000.833cdot K_a

The gage equals the module’s minimum gage, so that row sits at exactly 1.000:

[math] DCR = \frac{3.625\,in}{3.625\,in} = 1.000 [math]

DCR = 1.000, OK

Passo 2: Flange bolts in slip under the flange force (AISC 360-16 J3.8)

The moment becomes a force in each flange over the distance between flange centers, and half the axial force is added to it:

[math] P_{uF} = \frac{M_{ux}}{d_{bm} – t_{fb}} + \frac{P_{u}}{2} = \frac{38\,kip\text{-}ft}{18\,in – 0.57\,in} + \frac{66\,kip}{2} = 59.162\,kip [math]

This flange force is the demand for every check in the flange plate section. The four bolts are slip-critical, Eq. J3-4, with the report’s filler factor of 0.85:

[math] \phi R_{n} = \phi\, \mu\, D_{u}\, h_{f}\, T_{b}\, N_{s}\, n_{r}\, n_{c} = (0.85) \times (0.3) \times (1.13) \times (0.85) \times (64\,kip) \times (1) \times (2) \times (2) = 62.701\,kip [math]

DCR = 59.162 kip / 62.701 kip = 0.944 < 1.0, OK

Passo 3: Bolt bearing on the flange plate (AISC 360-16 J3.10)

The force runs along the beam, so the bolts bear toward the plate end. Com o 1.25 in oversized hole:

[math] l_{c1} = 1.5 – \frac{1.25}{2} = 0.875\,in, \qquad l_{c2} = 3 – 1.25 = 1.75\,in [math]

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.875, 2.4) \times 0.75 \times 65 \times 2 + \min(1.2 \times 1.75, 2.4) \times 0.75 \times 65 \times 2 \times 1 \right] = 230.34\,kip [math]

DCR = 59.162 kip / 230.34 kip = 0.257 < 1.0, OK

Passo 4: Bolt bearing on the beam flange (AISC 360-16 J3.10)

[math] l_{c1} = 1.5 – \frac{1.125}{2} = 0.9375\,in, \qquad l_{c2} = 1.875\,in [math]

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.57 \times 65 \times 2 + \min(1.2 \times 1.875, 2.4) \times 0.57 \times 65 \times 2 \times 1 \right] = 187.57\,kip [math]

DCR = 59.162 kip / 187.57 kip = 0.315 < 1.0, OK

Passo 5: Cisalhamento em bloco da placa do flange (AISC 360-16 J4.3)

Three tear-out shapes are checked, all with [mathin] U_{bs} = 1 [mathin] Estimativa da capacidade da pilha. J4-5:

[math] \phi R_{n} = \phi \left( 0.6 F_{up} A_{nv} + U_{bs} F_{up} A_{nt} \le 0.6 F_{yp} A_{gv} + U_{bs} F_{up} A_{nt} \right) [math]

PadrãoAgv (em²)Anv (em²)Ant (em²)phi Rn (kip)
L: um plano de cisalhamento, tensão através dos parafusos até uma borda3.3751.89842.3203168.64
você: dois planos de cisalhamento, tensão entre as linhas dos parafusos6.753.79691.7344195.61
2L: dois planos de cisalhamento, tensão de cada linha de parafuso até sua borda6.753.79691.1719168.19

For the governing 2L pattern:

[math] A_{nt} = 2 \times 0.75 \left[ 1.4375 – 0.5 \times (1.25 + 0.0625) \right] = 1.1719\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.7969 + 65 \times 1.1719 \le 0.6 \times 50 \times 6.75 + 65 \times 1.1719 \right) = 168.19\,kip [math]

DCR = 59.162 kip / 168.19 kip = 0.352 < 1.0, OK

Passo 6: Cisalhamento em bloco do banzo da viga (AISC 360-16 J4.3)

The beam flange tears out as two outer strips:

[math] A_{nt} = 0.57 \left[ 7.5 – 3.625 – 1 \times (1.1875) \right] = 1.5319\,in^{2} [math]

[math] A_{gv} = 2 \times 0.57 \left[ 1.5 + 3 \right] = 5.13\,in^{2}, \qquad A_{nv} = 2 \times 0.57 \left( 4.5 – 1.5 \times 1.1875 \right) = 3.0994\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.0994 + 65 \times 1.5319 \le 0.6 \times 50 \times 5.13 + 65 \times 1.5319 \right) = 165.34\,kip [math]

DCR = 59.162 kip / 165.34 kip = 0.358 < 1.0, OK

Passo 7: Cedência de tensão e ruptura da placa do flange (AISC 360-16 J4.1)

[math] \phi R_{n\_ty} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]

[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.75 \left[ 6.5 – 2 \times (1.3125) \right] = 141.68\,kip [math]

DCR = 59.162 kip / 141.68 kip = 0.418 < 1.0, OK

Passo 8: Tension rupture of the beam flange (AISC 360-16 D3, J4.1)

The flange force is taken by half the beam’s area, less the two flange holes, with the shear lag factor U = 0.283 from Table D3.1 case 2:

[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.283 \left[ 0.5 \times 14.7 – 2 \times (1.1875) \times 0.57 \right] = 82.726\,kip [math]

DCR = 59.162 kip / 82.726 kip = 0.715 < 1.0, OK

Passo 9: Ruptura por flexão da viga nos furos dos parafusos do flange (AISC 360-16 F13.1)

[math] A_{fg} = 7.5 \times 0.57 = 4.275\,in^{2}, \qquad A_{fn} = 4.275 – 2 \times (1.1875) \times 0.57 = 2.9213\,in^{2} [math]

With Fy / Fu = 0.76923, não mais que 0.8, Yt = 1. Então:

[math] F_{u} A_{fn} = 189.88\,kip \lt Y_{t} F_{y} A_{fg} = 213.75\,kip [math]

so the holes reduce the flexural strength and Eq. F13-1 applies, with the beam’s elastic modulus of 89.005 em³:

[math] M_{n} = \frac{F_{ub} A_{fn}}{A_{fg}}\, S_{x} = \frac{65 \times 2.9213}{4.275} \times 89.005 = 329.44\,kip\text{-}ft [math]

[math] \phi R_{n} = \frac{0.9\, M_{n}}{d_{bm} – t_{fb}} = \frac{0.9 \times 329.44\,kip\text{-}ft}{18\,in – 0.57\,in} = 204.13\,kip [math]

DCR = 59.162 kip / 204.13 kip = 0.290 < 1.0, OK

Passo 10: Compression of the flange plate (AISC 360-16 J4.4)

KL/r of the plate is no more than 25, então equação. J4-6 applies with no buckling reduction:

[math] \phi R_{n} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]

DCR = 59.162 kip / 219.38 kip = 0.270 < 1.0, OK

Passo 11: Detailing limit at the HSS face

Limite de detalhamentoLimite (no)Real (no)DCRResultado
Tamanho máximo de solda de ângulo por folga da viga0.5000.5001.000cdot K_a

A 1/2 in weld exactly fills the available clearance, o que é permitido:

DCR = 1.000, OK

Passo 12: Fillet weld from the flange plate to the HSS face (AISC 360-16 K1, K5, J2.4)

This is where the HSS changes the design. The base metal limit first, from Manual Eq. 9-2:

[math] D_{max} = \frac{(0.375)(65) \le (0.465)(62)}{3.09} = 7.8883 [math]

A 6.5 na placa é mais largo que o 4 in HSS face. The report allows that, but only the width over the face delivers load into it:

[math] B_{p,eff} = b_{fp} \le b = \min(6.5\,in, 4\,in) = 4\,in [math]

Eq. K1-1 then reduces it to the effective width:

[math] B_{e} = \left( \frac{10 t}{b} \right) \left( \frac{F_{ys}\, t}{F_{yp}\, t_{fp}} \right) B_{p,eff} \le B_{p,eff} = \left( \frac{10 \times 0.465}{4} \right) \left( \frac{50 \times 0.465}{50 \times 0.75} \right) \times 4 = 2.883\,in [math]

Per K5 the effective weld length is 2Be, and the report also caps Be at the workable flat:

[math] L_{w} = 2 \left( B_{e} \le W_{flat} \right) = 2 \times \min(2.883, 2.875) = 5.75\,in [math]

[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.5, \frac{7.8883}{16}\right) \times 5.75 = 63.144\,kip [math]

DCR = 59.162 kip / 63.144 kip = 0.937 < 1.0, OK

Passo 13: Local yielding of the flange plate on the HSS wall (AISC 360-16 K1, Guia de projeto 24)

The same effective width idea limits the force the plate can deliver into the wall. The report uses φ = 0.95 from AISC Design Guide 24, Tabela 7-2:

[math] \phi R_{n} = \phi \left( \frac{10\, t^{2}\, F_{ys}\, B_{p,eff}}{b} \le F_{yp}\, t_{fp}\, B_{p,eff} \right) = 0.95 \times \min\left( \frac{10 \times 0.465^{2} \times 50 \times 4}{4},\; 50 \times 0.75 \times 4 \right) = 102.71\,kip [math]

DCR = 59.162 kip / 102.71 kip = 0.576 < 1.0, OK

Passo 14: Local yielding of the HSS sidewalls

The flange force also reaches the two sidewalls of the tube through the corners. The report checks them with the expression below and φ = 1.0, without citing a clause, so it is the software’s limit for this check:

[math] \phi R_{n} = \phi \times 2 F_{ys}\, t \left[ 5 (1.5 t) + t_{fp} \right] = 1.0 \times 2 \times 50 \times 0.465 \left[ 5 \times (1.5 \times 0.465) + 0.75 \right] = 197.04\,kip [math]

DCR = 59.162 kip / 197.04 kip = 0.300 < 1.0, OK

Shear plate section

The shear plate is a conventional single plate welded to the HSS face and carries the 19 reação kip. Its checks follow the shear tab procedure, worked in full in Como projetar uma conexão de cisalhamento de placa única, with the HSS face checks added.

Passo 15: Detailing limits of the shear plate at the beam (AISC 360-16 J3.3, J3.4)

Limite de detalhamentoLimite (no)Real (no)DCRResultado
Espaçamento mínimo entre linhas de parafusos2.6673.0000.889cdot K_a
Espaçamento máximo entre linhas de parafusos6.0003.0000.500cdot K_a
Distância mínima da borda vertical da placa1.2501.5000.833cdot K_a
Distância mínima da borda horizontal da placa1.3751.5000.917cdot K_a
Distância mínima da borda horizontal do feixe1.2501.5000.833cdot K_a
Profundidade mínima de conexão7.7509.0000.861cdot K_a
Profundidade máxima de conexão16.0009.0000.563cdot K_a

[math] DCR = \frac{1.375\,in}{1.5\,in} = 0.917 [math]

DCR = 0.917 < 1.0, OK

Passo 16: Shear plate bolt group (AISC 360-16 J3.6)

No fillers, então [mathin] h_{f} = 1 [mathin] by J5.2(uma). The report uses C = 3 for the three web bolts:

[math] \phi R_{n} = 0.75 \times 68 \times \frac{\pi}{4} (1\,in)^{2} \times (1) \times (3) \times (1) = 120.17\,kip [math]

DCR = 19 kip / 120.17 kip = 0.158 < 1.0, OK

Passo 17: Bearing and tear-out on the shear plate (AISC 360-16 J3.10)

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.375 \times 58 + \min(1.2 \times 1.875, 2.4) \times 0.375 \times 58 \times 2 \right] \times \frac{3}{3} = 91.758\,kip [math]

DCR = 19 kip / 91.758 kip = 0.207 < 1.0, OK

Passo 18: Bearing and tear-out on the beam web (AISC 360-16 J3.10)

[math] \phi R_{n} = (0.75) \times \min(1.2 \times 1.875, 2.4) \times (0.355\,in) \times (65\,ksi) \times (3) = 116.82\,kip [math]

DCR = 19 kip / 116.82 kip = 0.163 < 1.0, OK

Passo 19: Resistência efetiva do grupo de parafusos de alma (AISC 360-16 Comentário J3.6)

Por parafuso: o cisalhamento 40.055 kip, plate edge bolt 18.352 kip, plate inner bolt 36.703 kip and beam web 38.939 kip. Parafusos 1 e 2 take the inner-bolt value and bolt 3 the edge value:

[math] \Sigma \phi r_{eff} = 2 \times (36.703\,kip) + 18.352\,kip = 91.758\,kip, \qquad \phi R_{n,eff} = 91.758 \times \frac{3}{3} = 91.758\,kip [math]

DCR = 19 kip / 91.758 kip = 0.207 < 1.0, OK

Passo 20: Block shear of the shear plate (AISC 360-16 J4.3)

[math] A_{nt} = 0.30469\,in^{2}, \quad A_{gv} = 2.8125\,in^{2}, \quad A_{nv} = 1.6992\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 58 \times 1.6992 + 58 \times 0.30469 \le 0.6 \times 36 \times 2.8125 + 58 \times 0.30469 \right) = 57.604\,kip [math]

DCR = 19 kip / 57.604 kip = 0.330 < 1.0, OK

Passo 21: Shear yielding and rupture of the shear plate (AISC 360-16 J4.2)

[math] \phi R_{n\_sy} = 1.0 \times 0.6 \times 36 \times 3.375 = 72.9\,kip, \qquad \phi R_{n\_sr} = 0.75 \times 0.6 \times 58 \times 2.0391 = 53.22\,kip [math]

DCR = 19 kip / 53.22 kip = 0.357 < 1.0, OK

Passo 22: Detailing limits of the shear plate at the HSS wall

Os valores de planicidade trabalhável e esbelteza são os limites do módulo para uma única placa em uma parede HSS.

Limite de detalhamentoLimite (no)Real (no)DCRResultado
Tamanho máximo de solda de ângulo por folga da viga0.5000.1880.376cdot K_a
Tamanho máximo de solda de filete por plano trabalhável HSS0.8850.1880.212cdot K_a
Esbeltez máxima da parede HSS b/t33.7165.6020.166cdot K_a

DCR = 0.376 < 1.0, OK

Passo 23: Weld from the shear plate to the HSS wall (AISC 360-16 J2.4)

[math] D_{max} = \frac{(0.1875)(58) \le (0.465)(62)}{3.09} = 3.5194, \qquad L_{w} = 2 \left[ 9 – 2 \times 0.1875 \right] = 17.25\,in [math]

[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.1875, \frac{3.5194}{16}\right) \times \left[ 1 + 0.5 \sin^{1.5}(0) \right] \times 17.25 = 72.042\,kip [math]

DCR = 19 kip / 72.042 kip = 0.264 < 1.0, OK

Passo 24: Perfuração de parede HSS (Eq Manual AISC. 10-7b, página 10-153)

[math] \phi R_{n} = \frac{0.75 \times 62 \times 0.465 \times 9^{2}}{5 \times 2} = 175.14\,kip [math]

DCR = 19 kip / 175.14 kip = 0.108 < 1.0, OK

Resumo das verificações de projeto

Verificação de projetoDemandaCapacidadeDCRResultado
A Especificação Nacional de Design: detailing at beam3.625 em calibre3.625 em minutos1.000cdot K_a
Flange bolts in slip59.162 kip62.701 kip0.944cdot K_a
Rolamento na placa do flange59.162 kip230.34 kip0.257cdot K_a
Rolamento no flange da viga59.162 kip187.57 kip0.315cdot K_a
Cisalhamento de bloco, placa de flange59.162 kip168.19 kip0.352cdot K_a
Cisalhamento de bloco, flange de viga59.162 kip165.34 kip0.358cdot K_a
Tensão da placa do flange59.162 kip141.68 kip0.418cdot K_a
Beam flange tension rupture59.162 kip82.726 kip0.715cdot K_a
Beam flexural rupture at holes59.162 kip204.13 kip0.290cdot K_a
Compressão da placa de flange59.162 kip219.38 kip0.270cdot K_a
A Especificação Nacional de Design: detailing at HSS face0.5 em solda0.5 no máximo1.000cdot K_a
Flange plate weld to HSS59.162 kip63.144 kip0.937cdot K_a
Flange plate local yielding59.162 kip102.71 kip0.576cdot K_a
HSS sidewall local yielding59.162 kip197.04 kip0.300cdot K_a
Shear plate: detailing at beam1.375 em minutos1.5 in edge0.917cdot K_a
Shear plate bolt group19 kip120.17 kip0.158cdot K_a
Bearing on shear plate19 kip91.758 kip0.207cdot K_a
Rolamento na teia do feixe19 kip116.82 kip0.163cdot K_a
Effective web bolt group strength19 kip91.758 kip0.207cdot K_a
Cisalhamento de bloco, shear plate19 kip57.604 kip0.330cdot K_a
Cedência por cisalhamento e ruptura, shear plate19 kip53.22 kip0.357cdot K_a
Shear plate: detailing at HSS wall0.188 em solda0.5 no máximo0.376cdot K_a
Shear plate weld to HSS19 kip72.042 kip0.264cdot K_a
Perfuração de parede HSS19 kip175.14 kip0.108cdot K_a

A conexão passa em todas as verificações. The two ratios at 1.000 are detailing limits that the layout meets exactly. Das verificações de força, the flange bolts in slip govern at 0.944, followed closely by the flange plate weld to the HSS face at 0.937. The weld is limited by the HSS: só 2.883 dentro do 6.5 in plate counts as effective width, and the weld length is capped at the 2.875 in workable flat of the 4 in face.

O que mudar se uma verificação falhar

  • Flange bolts in slip: add bolts along the beam, use um parafuso maior, or a Class B faying surface. A deeper beam lowers the flange force for the same moment.
  • Flange plate weld to the HSS: a thicker HSS wall raises Be, since Be grows with the square of the wall thickness, and a wider tube face gives a longer workable flat. A thicker flange plate lowers Be, so do not thicken the plate to fix this check.
  • Flange plate local yielding or HSS sidewall yielding: use a thicker-walled tube.
  • Beam flange tension rupture or flexural rupture: reduce the holes in the flange or use a heavier beam.
  • Block shear or plate tension: increase the edge distances, the bolt spacing or the plate thickness.
  • Shear plate checks: as for a shear tab, add a bolt row or make the plate deeper.

Auto Design is available for the flange plate moment connection to an HSS column. Ele muda os parafusos, plates and welds until every check passes, e mantém seus membros e cargas conforme inseridos. Veja o Projeto Automático página para as preferências para as quais funciona.

Perguntas frequentes

How is this different from a flange plate connection to a W-shape column?

The beam side checks, Passos 1 para 10, are the same as in Como projetar uma conexão de momento de placa de flange. The difference is at the column. On a W-shape column the plates weld to a thick flange backed by the column web. An HSS face is a thin wall between the corners, so the flange plate is reduced to an effective width for the weld and for plate local yielding, and the tube sidewalls are checked for local yielding.

Por que é que 6.5 in flange plate wider than the 4 in HSS face?

The plate is sized to bolt to the 7.5 in beam flange at a 3.625 em calibre, which needs more width than the tube face has. The report allows a plate wider than the face, but only the 4 in over the face counts when the force goes into the HSS.

What is the effective width Be?

Eq. K1-1 reduces a plate welded across an HSS face to the width that is effective in carrying load into the wall. It depends on the wall slenderness b/t and on the ratio of wall to plate strength and thickness. Here Be = 2.883 dentro do 4 in effective plate width.

Why is the flange force 59.162 kip?

A 38 kip-ft moment is divided by the distance between flange centers, 17.43 no, dando 26.162 kip, and half of the 66 kip axial force is added to each flange. The report uses this one flange force for every check in the flange plate section.

Does this example follow the AISC 15th or 16th edition Manual?

Segue AISC 360-16 with the AISC Manual 15th Edition and AISC Design Guide 24 for the HSS plate local yielding factor. Clause and page references move in the 16th Edition Manual and AISC 360-22, então compare-os com a edição que seu projeto usa.

Design a flange plate moment connection to an HSS column for free

Cada número nesta página vem de uma solução. Pick the flange plate moment connection to an HSS column, entre no seu raio, tubo, placas, parafusos e cargas, e veja cada uma dessas verificações em seu navegador. Não há nada para instalar.

O módulo SkyCiv Connection Design é o software de design de conexão por trás deste exemplo. Fornece o relatório de cálculo completo com todas as equações e seus números, como as etapas acima, além de todas as capacidades e DCR, para AISC 360-22 e AISC 360-16 (LRFD e ASD) e a norma AS 4100:2020. A calculadora de parafuso e calculadora de solda cubra o grupo de parafusos e verifique a soldagem por conta própria.

Referências

Harold Munalem, Gerente de produto do SkyCiv Connection Design

Harold Munalem
gerente de produto, Connection Design
10+ anos em projetos de conexões de aço
LinkedIn

Como podemos ajudar?

×

Vá para o topo