When a beam framing into an HSS column also carries an axial force, for a drag strut, a collector or a braced bay, the single plate has to pass that force into the tube wall as well as the end shear. To AISC 360-16 this adds a set of checks to the shear tab design: bearing and tear-out in the axial direction, block shear under axial load, traction et compression des plaques, combined interaction, beam web block shear and beam tension rupture, et, most important, the strength of the HSS wall under a force pulling or pushing straight on it.

This page works through one example: a W18x35 beam into the 6 dans le mur d'une colonne HSS8x6x1/2, avec 32 cisaillement et 93 kip d'effort axial (tension et compression) under LRFD, dix 1 in A490-SC bolts in two columns and a 3/4 in Grade 50 plaque. The shear-only version of this connection is covered in Single Plate to HSS Column Connection Design, so here the shear checks are kept short and the page concentrates on what the axial force adds. Every number comes from the SkyCiv Connection Design calc sheet.

What does the axial force change in a single plate to HSS connection?

A shear tab on its own is a simple assemblage de cisaillement and the HSS wall only sees an eccentric vertical load. An axial force acts at right angles to the wall. In tension it pulls the plate away from the tube and the wall bends like a plate between the corners; in compression it pushes the plate in. Because a tube wall is thin and flexible out of its plane, this is usually where a shear and axial tab on an HSS runs out of strength, long before the bolts or plate do.

The axial force also changes which way the bolts bear. In tension they bear toward the free ends, the end of the plate and the end of the beam; in compression they bear toward the support and the span. The software checks both directions and combines each with the shear. You can run the connection in the calculateur de connexion à plaque unique.

Élévation: W18x35 beam on a 3/4 in single plate welded to an HSS8x6x1/2 wall, two columns of five 1 dans les boulons A490-SC

Élévation de l'exemple de connexion, with the shear and the axial tension and compression acting at the bolt group.

Section A-A à travers le 3/4 in x 6 1/2 en x 15 in Grade 50 single plate with 1/2 dans E70XX, soudures d'angle des deux côtés

Section A-A. La plaque comporte des trous horizontaux à fentes courtes et un 1/2 en soudure d'angle des deux côtés.

3D view of the shear and axial single plate connection: W18x35 beam framing into a rectangular HSS8x6x1/2 column

3Vue D de la connexion dans SkyCiv Connection Design.

Les étapes en un coup d'œil

The report runs 28 vérifications. The ones in bold are added, or changed, by the axial force:

  1. Detailing limits at the beam.
  2. Bolt group in slip, under the resultant of shear and axial.
  3. Ductilité des plaques.
  4. Bearing and tear-out on the plate, cisaillement.
  5. Bearing and tear-out on the plate, tension axiale.
  6. Bearing and tear-out on the plate, compression axiale.
  7. Shear and axial interaction, roulement à plaques.
  8. Bearing and tear-out on the beam web, cisaillement.
  9. Bearing and tear-out on the beam web, tension axiale.
  10. Bearing and tear-out on the beam web, compression axiale.
  11. Shear and axial interaction, beam web bearing.
  12. Block shear of the plate, cisaillement.
  13. Block shear of the plate, axial.
  14. Shear and axial interaction, plate block shear.
  15. Shear yielding and rupture of the plate.
  16. Flexion de la plaque.
  17. Plate tension yielding and rupture.
  18. Cisaillement, tension and flexure interaction, plastification.
  19. Cisaillement, tension and flexure interaction, rupture.
  20. Compression des plaques.
  21. Cisaillement, compression and flexure interaction.
  22. Cisaillement du bloc de l'âme de la poutre, axial.
  23. Rupture de tension de poutre.
  24. Limites de détail au mur HSS.
  25. Souder pour développer la plaque.
  26. Weld to the HSS wall, under the resultant.
  27. Poinçonnage mural HSS.
  28. HSS wall under the axial force.

Entrées de conception pour cet exemple

Le code de conception est AISC 360-16 LRFD. The beam and column are the same as in the shear-only example; les boulons, plate and weld are larger to carry the axial force. How the loads are entered is explained in charges et combinaisons de charges.

ArticleSymboleValeur
Cisaillement pondéré[mathin] V_{u} [mathin]32 kip
Tension axiale pondérée[mathin] T_{u} [mathin]93 kip
Compression axiale pondérée[mathin] C_{u} [mathin]93 kip
BeamL18x35, ASTM A992 (d = 17.7 in, tw = 0.3 in, Un = 10.3 po², AF / Fu = 50 / 65 ksi)
PoteauHSS8x6x1/2, ASTM A500 Gr. C (AF / Fu = 50 / 62 ksi)
HSS wall width / design thickness / workable flat[mathin] b,\ t,\ W_{flat} [mathin]6 in / 0.465 in / 4.875 in
ArticleSymboleValeur
Plaque uniquePL 3/4 X 6 1/2 X 15, ASTM A572 Gr.. 50 (AF / Fu = 50 / 65 ksi)
Boulons1 en A490-SC, Surface de contact de classe A
Bolt shear stress / contrainte de traction[mathin] F_{nv},\ F_{nt} [mathin]68 ksi / 113 ksi
Trousassiette: horizontale à fente courte (CSSS). Toile de poutre: nommée (MST)
Souder au mur HSS1/2 en filet des deux côtés, E70XX
Rangées de boulons / espacement des rangs[mathin] n_{r},\ s_{r} [mathin]5 / 3 in
Colonnes de boulons / espacement des colonnes[mathin] n_{c},\ s_{c} [mathin]2 / 3 in
Weld line to first bolt line[mathin] a [mathin]2 in
Edge distances, plate and beam1.5 in
Excentricité de conception (Tableau manuel 10-9)[mathin] e [mathin]3.5 in

Étape 1: Limites de détail côté poutre (AISC 360-16 J3.3, J3.4)

The same limits as for the shear-only connection, now for a 1 en boulon: 2.667 in minimum spacing, 1.25 in minimum edge from Table J3.4, et 1.375 in at the plate’s slotted horizontal edge.

Limite de détailLimite (in)Réel (in)DCRRésultat
Minimum bolt row / espacement des colonnes2.6673.0000.889cdot K_a
Maximum bolt row / espacement des colonnes6.0003.0000.500cdot K_a
Distance minimale du bord vertical de la plaque1.2501.5000.833cdot K_a
Distance minimale du bord horizontal de la plaque1.3751.5000.917cdot K_a
Distance minimale du bord horizontal de la poutre1.2501.5000.833cdot K_a
Profondeur de connexion minimale7.75015.0000.517cdot K_a
Profondeur de connexion maximale16.00015.0000.938cdot K_a

[math] DCR = \frac{15\,in}{16\,in} = 0.938 [math]

DCR = 0.938 < 1.0, d'accord

Étape 2: Bolt group in slip under shear and axial (AISC 360-16 J3.8)

With slip-critical bolts the group is designed against slip, Eq. J3-4, for the resultant of the shear and the axial force. L'excentricité est 3.5 in from Manual Table 10-9, and the ICOR coefficient for the inclined load on the 2 X 5 group is C = 8.41 (the IC converges at x = -0.78739 in, y = 13.997 in).

VerrouillerR (kip)Rx (kip)Ry (kip)Mn (poulet dans)
118.0618.031.01253.19
217.6617.621.26194.75
316.8416.761.65135.35
415.0914.912.3576.35
511.0710.304.0623.76
618.1017.474.73262.47
717.7716.805.79206.67
817.1315.487.33151.58
915.9712.739.65100.15
1014.356.6912.6961.43

[math] R_{u} = \sqrt{V_{u}^{2} + T_{u}^{2}} = \sqrt{32^{2} + 93^{2}} = 98.351\,kip [math]

[math] \phi R_{n} = \phi\, \mu\, D_{u}\, h_{f}\, T_{b}\, N_{s}\, C = (0.85) \times (0.3) \times (1.13) \times (1) \times (64\,kip) \times (1) \times (8.41) = 155.09\,kip [math]

DCR = 98.351 kip / 155.09 kip = 0.634 < 1.0, d'accord

Étape 3: Ductilité des plaques (Page du manuel AISC 10-89)

Unlike the shear-only example, this layout does need the check. The moment coefficient of the group is C’ = 38.669 in:

[math] M_{max} = \frac{F_{nv}}{0.9}\, \frac{\pi}{4} d_{b}^{2}\, C’ = \frac{68\,ksi}{0.9} \times \frac{\pi}{4} (1\,in)^{2} \times (38.669\,in) = 191.22\,kip\text{-}ft [math]

[math] t_{max} = \frac{6 M_{max}}{F_{yp} d_{p}^{2}} = \frac{6 \times (191.22\,kip\text{-}ft)}{(50\,ksi) \times (15\,in)^{2}} = 1.2238\,in [math]

DCR = 0.75 in / 1.2238 dans = 0.613 < 1.0, d'accord

Étape 4: Plate bearing and tear-out under shear (AISC 360-16 J3.10)

As in the shear-only example, avec [mathin] d_{h} = 1.125\,in [mathin], an edge clear distance of 0.9375 dans et 1.875 in between bolts, scaled by C over the five bolts in a line:

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.75 \times 65 + \min(1.2 \times 1.875, 2.4) \times 0.75 \times 65 \times 4 \right] \times \frac{8.41}{5} = 622.67\,kip [math]

DCR = 32 kip / 622.67 kip = 0.051 < 1.0, d'accord

Étape 5: Plate bearing and tear-out under axial tension (AISC 360-16 J3.10)

Under tension the bolts bear on the plate toward its free end. The hole dimension along the slot is [mathin] d_{h} = 1.3125\,in [mathin], donc les distances claires sont:

[math] l_{c1} = L_{eh\_pl} – \frac{d_{h}}{2} = 1.5 – 0.65625 = 0.84375\,in, \qquad l_{c2} = s_{c} – d_{h} = 1.6875\,in [math]

Along the axial direction there are two bolts in each row, the outer one at the edge and the inner one behind it. The sum is scaled by C over the two bolt columns:

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.84375, 2.4) \times 0.75 \times 65 + \min(1.2 \times 1.6875, 2.4) \times 0.75 \times 65 \times (2 – 1) \right] \times \frac{8.41}{2} = 467\,kip [math]

DCR = 93 kip / 467 kip = 0.199 < 1.0, d'accord

Étape 6: Plate bearing and tear-out under axial compression (AISC 360-16 J3.10)

Under compression the bolts bear on the plate toward the support. The edge distance for the bolt nearest the wall is the 2 en distance soudure-boulon:

[math] l_{c1} = a – \frac{d_{h}}{2} = 2 – 0.65625 = 1.3438\,in, \qquad l_{c2} = 1.6875\,in [math]

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 1.3438, 2.4) \times 0.75 \times 65 + \min(1.2 \times 1.6875, 2.4) \times 0.75 \times 65 \times (2 – 1) \right] \times \frac{8.41}{2} = 559.25\,kip [math]

DCR = 93 kip / 559.25 kip = 0.166 < 1.0, d'accord

Étape 7: Shear and axial interaction of plate bearing

The axial direction with the larger ratio of load to bearing strength is used, here tension:

[math] \left( \frac{V_{u}}{\phi R_{n,V}} \right)^{2} + \left( \frac{T_{u}}{\phi R_{n,T}} \right)^{2} = \left( \frac{32}{622.67} \right)^{2} + \left( \frac{93}{467} \right)^{2} = 0.042299 [math]

DCR = 0.042 < 1.0, d'accord

Étape 8: Beam web bearing and tear-out under shear (AISC 360-16 J3.10)

[math] \phi R_{n} = (0.75) \times \min(1.2 \times 1.875, 2.4) \times (0.3\,in) \times (65\,ksi) \times (8.41) = 276.74\,kip [math]

DCR = 32 kip / 276.74 kip = 0.116 < 1.0, d'accord

Étape 9: Beam web bearing and tear-out under axial tension (AISC 360-16 J3.10)

Under tension the bolts bear on the beam web toward the end of the beam, so the edge bolt uses the 1.5 in beam horizontal edge distance:

[math] l_{c1} = 1.5 – \frac{1.125}{2} = 0.9375\,in, \qquad l_{c2} = 3 – 1.125 = 1.875\,in [math]

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.3 \times 65 + \min(1.2 \times 1.875, 2.4) \times 0.3 \times 65 \times (2 – 1) \right] \times \frac{8.41}{2} = 207.56\,kip [math]

DCR = 93 kip / 207.56 kip = 0.448 < 1.0, d'accord

Étape 10: Beam web bearing and tear-out under axial compression (AISC 360-16 J3.10)

Under compression the bolts bear toward the span, où le Web est continu. Le boulon le plus éloigné n'a aucun bord au-delà, so it takes full bearing, 2.4 d t Fu:

[math] \phi R_{n} = (0.75) \left[ 2.4 \times 1 \times 0.3 \times 65 + \min(1.2 \times 1.875, 2.4) \times 0.3 \times 65 \times (2 – 1) \right] \times \frac{8.41}{2} = 285.97\,kip [math]

DCR = 93 kip / 285.97 kip = 0.325 < 1.0, d'accord

Étape 11: Shear and axial interaction of beam web bearing

Tension governs again:

[math] \left( \frac{32}{276.74} \right)^{2} + \left( \frac{93}{207.56} \right)^{2} = 0.21414 [math]

DCR = 0.214 < 1.0, d'accord

Étape 12: Plate block shear under shear (AISC 360-16 J4.3)

The block runs down the two bolt lines and out to the free edge. The report takes [mathin] U_{bs} = 0.5 [mathin] for this two-column layout:

[math] A_{nt} = 1.8281\,in^{2}, \quad A_{gv} = 10.125\,in^{2}, \quad A_{nv} = 6.1172\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 6.1172 + 0.5 \times 65 \times 1.8281 \le 0.6 \times 50 \times 10.125 + 0.5 \times 65 \times 1.8281 \right) = 223.49\,kip [math]

DCR = 32 kip / 223.49 kip = 0.143 < 1.0, d'accord

Étape 13: Plate block shear under axial load (AISC 360-16 J4.3)

Under the axial force the block tears out in the other direction: tension across the bolt rows to one plate edge, and shear along the outer bolt row to the plate end.

[math] A_{nt} = 0.75 \left[ (5 – 1) \times 3 + 1.5 – 4.5 \times (1.1875) \right] = 6.1172\,in^{2} [math]

[math] A_{gv} = 0.75 \left[ 1.5 + (2 – 1) \times 3 \right] = 3.375\,in^{2} [math]

[math] A_{nv} = 0.75 \left[ 6.5 – 2 – 1.5 \times (1.3125 + 0.0625) \right] = 1.8281\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 1.8281 + 65 \times 6.1172 \le 0.6 \times 50 \times 3.375 + 65 \times 6.1172 \right) = 351.69\,kip [math]

DCR = 93 kip / 351.69 kip = 0.264 < 1.0, d'accord

Étape 14: Shear and axial interaction of plate block shear

[math] \left( \frac{32}{223.49} \right)^{2} + \left( \frac{93}{351.69} \right)^{2} = 0.090431 [math]

DCR = 0.090 < 1.0, d'accord

Étape 15: Plate shear yielding and rupture (AISC 360-16 J4.2)

[math] \phi R_{n\_sy} = 1.0 \times 0.6 \times 50 \times 11.25 = 337.5\,kip, \qquad \phi R_{n\_sr} = 0.75 \times 0.6 \times 65 \times 6.7969 = 198.81\,kip [math]

DCR = 32 kip / 198.81 kip = 0.161 < 1.0, d'accord

Étape 16: Flexion de la plaque selon la procédure de poutre à double chape (AISC 360-16 F11.2)

The same procedure as the shear-only example, sur le 2 de la soudure à la ligne de boulon. With Lb d / t² = 53.333, entre 46.4 et 1102, Eq. F11-2 applies and the plate reaches its plastic moment:

[math] \phi M_{n} = 0.9 \times \min\left[ C_{b} \left( 1.52 – 0.274 \times 53.333 \times \frac{50}{29000} \right) \times 50 \times 28.125,\; 50 \times 42.188 \right] = 158.2\,kip\text{-}ft \;\Rightarrow\; \phi V_{n} = 949.22\,kip [math]

[math] Z_{net} = 25.892\,in^{3}, \qquad \phi M_{n} = 0.75 \times 65 \times 25.892 = 105.19\,kip\text{-}ft \;\Rightarrow\; \phi V_{n} = 631.11\,kip [math]

DCR = 32 kip / 631.11 kip = 0.051 < 1.0, d'accord

Étape 17: Plate tension yielding and rupture (AISC 360-16 J4.1)

The plate is a tension member for the axial force, checked on its full 15 en profondeur:

[math] \phi R_{n\_ty} = 0.9 \times F_{yp}\, t_{p}\, d_{p} = 0.9 \times 50 \times 0.75 \times 15 = 506.25\,kip [math]

[math] \phi R_{n\_tr} = 0.75 \times F_{up}\, t_{p} \left[ d_{p} – n_{r} (d_{h} + 0.0625) \right] = 0.75 \times 65 \times 0.75 \left[ 15 – 5 \times (1.1875) \right] = 331.35\,kip [math]

DCR = 93 kip / 331.35 kip = 0.281 < 1.0, d'accord

Étape 18: Cisaillement, tension and flexure interaction, plastification (Partie du manuel AISC 10)

[math] \left( \frac{T_{u}}{2 \phi R_{n\_ty}} + \frac{V_{u}}{\phi V_{n}} \right)^{2} + \left( \frac{V_{u}}{\phi R_{n\_sy}} \right)^{2} = \left( \frac{93}{2 \times 506.25} + \frac{32}{949.22} \right)^{2} + \left( \frac{32}{337.5} \right)^{2} = 0.024756 [math]

DCR = 0.025 < 1.0, d'accord

Étape 19: Cisaillement, tension and flexure interaction, rupture (Partie du manuel AISC 10)

[math] \left( \frac{T_{u}}{\phi R_{n\_tr}} + \frac{8 V_{u}}{9 \phi V_{n}} \right)^{2} + \left( \frac{V_{u}}{\phi R_{n\_sr}} \right)^{2} = \left( \frac{93}{331.35} + \frac{8 \times 32}{9 \times 631.11} \right)^{2} + \left( \frac{32}{198.81} \right)^{2} = 0.13202 [math]

DCR = 0.132 < 1.0, d'accord

Étape 20: Compression des plaques (AISC 360-16 J4.4)

KL/r of the plate is no more than 25, donc équation. J4-6 applies with no buckling reduction:

[math] \phi R_{n} = 0.9\, F_{yp}\, t_{p}\, d_{p} = 0.9 \times 50 \times 0.75 \times 15 = 506.25\,kip [math]

DCR = 93 kip / 506.25 kip = 0.184 < 1.0, d'accord

Étape 21: Cisaillement, compression and flexure interaction (Partie du manuel AISC 10)

[math] \left( \frac{C_{u}}{2 \phi R_{n}} + \frac{V_{u}}{\phi V_{n}} \right)^{2} + \left( \frac{V_{u}}{\phi R_{n\_sy}} \right)^{2} = \left( \frac{93}{2 \times 506.25} + \frac{32}{949.22} \right)^{2} + \left( \frac{32}{337.5} \right)^{2} = 0.024756 [math]

DCR = 0.025 < 1.0, d'accord

Étape 22: Beam web block shear under axial load (AISC 360-16 J4.3)

The tension force can also tear a block out of the beam web: tension across the five bolt rows and shear along the top and bottom rows to the beam end.

[math] A_{nt} = 0.3 \left[ (5 – 1) \times 3 – (5 – 1) \times (1.1875) \right] = 2.175\,in^{2} [math]

[math] A_{gv} = 2 \times 0.3 \left[ 1.5 + 3 \right] = 2.7\,in^{2}, \qquad A_{nv} = 2 \times 0.3 \left[ 3 + 1.5 – 1.5 \times (1.1875) \right] = 1.6313\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 1.6313 + 65 \times 2.175 \le 0.6 \times 50 \times 2.7 + 65 \times 2.175 \right) = 153.75\,kip [math]

DCR = 93 kip / 153.75 kip = 0.605 < 1.0, d'accord

Étape 23: Rupture de tension de poutre (AISC 360-16 D3, J4.1)

Seule la toile est boulonnée, so shear lag reduces the effective net area of the beam. The report uses U = 0.73655 from Table D3.1 case 2:

[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.73655 \left[ 10.3 – 5 \times (1.125 + 0.0625) \times 0.3 \right] = 305.88\,kip [math]

DCR = 93 kip / 305.88 kip = 0.304 < 1.0, d'accord

Étape 24: Limites de détail au mur HSS

The weld-on-flat and slenderness values are the module’s limits for a single plate on an HSS wall.

Limite de détailLimite (in)Réel (in)DCRRésultat
Taille maximale de soudure d'angle par dégagement de poutre0.5000.5001.000cdot K_a
Taille maximale de soudure d'angle par plat réalisable HSS1.5380.5000.325cdot K_a
Élancement maximal du mur HSS b/t33.7169.9030.294cdot K_a

Le 1/2 in weld exactly fills the 1/2 dans le dégagement du faisceau, ce qui est autorisé:

[math] DCR = \frac{0.5\,in}{0.5\,in} = 1.000 [math]

DCR = 1.000, d'accord

Étape 25: Soudure nécessaire pour développer la plaque unique (Page du manuel AISC 10-87)

[math] W_{duc} = \frac{5}{8} \times (0.75\,in) = 0.46875\,in [math]

DCR = 0.46875 in / 0.5 dans = 0.938 < 1.0, d'accord

Étape 26: Fillet weld strength to the HSS wall under the resultant (AISC 360-16 J2.4)

The weld now carries the resultant of the shear and the axial force, at an angle to its axis. That angle earns the directional strength increase of Eq. J2-5, which a pure shear load on a vertical weld does not get:

[math] \theta = 71.012^{\circ}, \qquad D_{max} = \frac{(0.375)(65) \le (0.465)(62)}{3.09} = 7.8883, \qquad L_{w} = 2 \left[ 15 – 2 \times 0.5 \right] = 28\,in [math]

[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.5, \frac{7.8883}{16}\right) \times \left[ 1 + 0.5 \sin^{1.5}(71.012) \right] \times 28 = 448.85\,kip [math]

DCR = 98.351 kip / 448.85 kip = 0.219 < 1.0, d'accord

Étape 27: Poinçonnage mural HSS (Éq. manuel AISC. 10-7b, page 10-153)

[math] \phi R_{n} = \frac{0.75 \times 62 \times 0.465 \times 15^{2}}{5 \times 3.5} = 278\,kip [math]

DCR = 32 kip / 278 kip = 0.115 < 1.0, d'accord

Étape 28: HSS wall under the axial force

This is the check the axial force exists for. The plate pulls (or pushes) on the middle of the tube wall, and the wall resists by forming a yield line pattern across its workable flat. The report uses the yield line expression it attributes to R. Kapp, which is the software’s method for this limit state:

[math] \phi R_{n} = 0.75 \left[ \frac{F_{ys}\, t^{2}\, d_{p}}{0.5 (W_{flat} – t_{p})} + 4 F_{ys}\, t^{2} \sqrt{1 + \frac{t_{p}}{W_{flat} – t_{p}}} \right] [math]

[math] \phi R_{n} = 0.75 \left[ \frac{50 \times 0.465^{2} \times 15}{0.5 \times (4.875 – 0.75)} + 4 \times 50 \times 0.465^{2} \times \sqrt{1 + \frac{0.75}{4.875 – 0.75}} \right] = 94.23\,kip [math]

DCR = 93 kip / 94.23 kip = 0.987 < 1.0, d'accord

The first term grows with the plate depth and falls as the workable flat gets wider, and both terms grow with the square of the wall thickness. That is why the wall, not the bolts or the plate, sets the axial capacity of this connection.

Résumé des contrôles de conception

Vérification de la conceptionDemandeCapacitéDCRRésultat
Détails côté poutre15 en profondeur16 en maximum0.938cdot K_a
Bolt group in slip (résultant)98.351 kip155.09 kip0.634cdot K_a
Ductilité des plaques0.75 in1.2238 in0.613cdot K_a
Roulement à plaques, cisaillement32 kip622.67 kip0.051cdot K_a
Roulement à plaques, tension axiale93 kip467 kip0.199cdot K_a
Roulement à plaques, compression axiale93 kip559.25 kip0.166cdot K_a
Plate bearing interaction0.042cdot K_a
Support d'âme de poutre, cisaillement32 kip276.74 kip0.116cdot K_a
Support d'âme de poutre, tension axiale93 kip207.56 kip0.448cdot K_a
Support d'âme de poutre, compression axiale93 kip285.97 kip0.325cdot K_a
Beam web bearing interaction0.214cdot K_a
Cisaillement de bloc de la plaque, cisaillement32 kip223.49 kip0.143cdot K_a
Cisaillement de bloc de la plaque, axial93 kip351.69 kip0.264cdot K_a
Interaction de cisaillement de bloc de plaques0.090cdot K_a
Plate shear yielding and rupture32 kip198.81 kip0.161cdot K_a
Flexion de la plaque32 kip631.11 kip0.051cdot K_a
Plate tension93 kip331.35 kip0.281cdot K_a
Interaction, tension yielding0.025cdot K_a
Interaction, tension rupture0.132cdot K_a
Compression des plaques93 kip506.25 kip0.184cdot K_a
Interaction, compression0.025cdot K_a
Cisaillement de bloc d'âme de poutre, axial93 kip153.75 kip0.605cdot K_a
Rupture de tension de poutre93 kip305.88 kip0.304cdot K_a
Détails sur le mur HSS0.5 en soudure0.5 en maximum1.000cdot K_a
Souder pour développer la plaque0.46875 in0.5 in0.938cdot K_a
Souder au mur HSS (résultant)98.351 kip448.85 kip0.219cdot K_a
Poinçonnage mural HSS32 kip278 kip0.115cdot K_a
HSS wall under axial93 kip94.23 kip0.987cdot K_a

La connexion passe tous les contrôles. The HSS wall under the 93 kip axial force governs at 0.987, and the next strength checks are the bolt group in slip (0.634) and block shear of the beam web (0.605). Everything in the plate is lightly loaded. The two ratios at 0.938 et 1.000 are detailing and weld sizing rules, not load against capacity.

Que changer si une vérification échoue

  • HSS wall under axial: this is the usual limit. A thicker HSS wall helps most, because the strength grows with the square of the wall thickness. A deeper plate also helps. If neither can change, the axial force needs a different connection type.
  • Bolt slip or bearing: add bolt rows or a bolt column, ou utilisez un boulon plus gros. For bearing under tension, a larger edge distance to the free end helps.
  • Beam web block shear or beam tension rupture: add bolt rows to lengthen the block and raise U, or use a beam with a thicker web.
  • Plate tension, compression ou cisaillement de bloc: rendre la plaque plus profonde ou plus épaisse, while keeping the ductility check below 1.0.
  • Souder: a larger weld, as long as it fits within the beam clearance and on the workable flat.

Auto Design is available for the single plate connection to an HSS column with shear and axial load. Ça change les boulons, plaque et soudures jusqu'à ce que chaque contrôle soit réussi, et conserve vos membres et vos charges tels qu'ils ont été saisis. Voir le Conception automatique page pour les préférences sur lesquelles il fonctionne.

Questions fréquentes

Why are the bolts slip-critical in this example?

A beam carrying both shear and an axial force that reverses between tension and compression is a typical case for slip-critical bolts, so the joint does not slip back and forth through the hole clearance. The report then checks the group against slip with Eq. J3-4 under the resultant of the two forces.

Why does the report check bearing in two axial directions?

In tension the bolts bear toward the free end of the plate and the end of the beam, where the edge distance is short. In compression they bear toward the support and the span, where the plate edge is the weld line and the beam web is continuous. The two give different tear-out strengths, so both are checked, and the interaction uses the direction with the larger ratio.

Why is the weld stronger under the combined load than under shear alone?

A fillet weld loaded at an angle to its axis is stronger than one loaded along it, par le facteur 1 + 0.5 sin^1.5 of the angle in Eq. J2-5. The resultant here is at 71 degrees to the weld, which raises the weld strength by about 46%.

How does the shear-only connection compare?

The shear-only example, Conception de connexion à plaque unique et colonne HSS, uses three 3/4 in bolts and a 3/8 in plate on the same beam and tube, and is governed by bolt shear at 0.660. The axial force here needs ten 1 in bolts and a 3/4 en assiette, and the tube wall becomes the limit.

Can the axial force be larger with this tube?

Not by much. À 93 kip the HSS wall check is already at 0.987. For a larger axial force, utiliser un tube à paroi plus épaisse ou une plaque plus profonde.

Design a shear and axial single plate to HSS column connection for free

Chaque numéro sur cette page provient d'une seule solution. Choisissez la connexion à plaque unique à une colonne HSS, entrez votre faisceau, tube, boulons, cisaillement et charge axiale, et voyez chacune de ces vérifications dans votre navigateur. Il n'y a rien à installer.

Le module SkyCiv Connection Design est le logiciel de conception de connexion derrière cet exemple. Il vous donne le rapport de calcul complet avec chaque équation et vos chiffres, comme les étapes ci-dessus, plus toutes les capacités et DCR, selon AISC 360-22 et AISC 360-16 (LRFD et TSA) et AS 4100:2020. Le calculateur de boulons et calculateur de soudure couvrir le groupe de boulons et les contrôles de soudure seuls.

Références

  • AISC 360-16, Spécification pour les bâtiments en acier de construction: D3 (Tableau D3.1), F11.2 (Eq. F11-2), J2.4 (Eq. J2-4, J2-5), J3.3, J3.4 (Tableau J3.4), J3.5 (Tableau J3.5), J3.8 (Eq. J3-4), J3.10 (Eq. J3-6a, J3-6c), J4.1 (Eq. J4-1, J4-2), J4.2 (Eq. J4-3, J4-4), J4.3 (Eq. J4-5), J4.4 (Eq. J4-6).
  • Manuel de construction en acier AISC, 15e édition: Partie 9, Eq. 9-2, 9-4 et 9-15; Partie 10, Tableau 10-9, des pages 10-87 et 10-89 (Eq. 10-3, 10-4), Eq. 10-7b (page 10-153); Partie 15, Tableau 15-3.
  • HSS wall under axial load: yield line analysis by R. Kapp, as used in the report.
  • Comment concevoir une connexion par cisaillement à plaque unique (Colonne en forme de W)
  • Conception d'assemblages en acier utilisant AISC 360-16
Harold Munalem, Chef de produit pour SkyCiv Connection Design

Harold Munalem
Chef de produit, Connection Design
10+ années dans la conception d'assemblages en acier