Documentation SkyCiv

Votre guide du logiciel SkyCiv — tutoriels, guides pratiques et articles techniques

Conception de connexion de moment de plaque de bride à AS 4100

To design a bolted flange plate moment connection to AS 4100, you turn the beam end moment into a tension and compression force pair at the flanges, then follow each flange force from the beam flange, through the bolts and the flange plate, into the weld and the column. The web side plate is a separate shear connection that carries the vertical shear. Both are checked against their detailing limits first.

Cette page fonctionne à travers un exemple du début à la fin: a 460 UB 74.6 beam joined to the flange of a 310 UC 158 column with 25 mm Nuance 300 plaques de bride, eight M20 8.8/S bolts per flange and a 10 mm web side plate. It is designed to AS 4100:2020 pour un moment de 70 kNm, une cisaille de 80 kN and an axial envelope of 60 kN tension and 90 kN compression. Chaque équation est écrite avec ses chiffres, dans le même ordre que le rapport de calcul que le SkyCiv Connection Design le module produit pour cela. Le champ d'application et les conventions de l'AS 4100 module sont sur le conception d'assemblages en acier utilisant AS 4100:2020 page.

Qu'est-ce qu'une connexion par moment de plaque à bride?

A flange plate moment connection has a plate on the top and bottom flanges of the beam. Each plate is fillet welded to the column flange in the shop and bolted to the beam flange on site, so the flange forces from the moment pass through the plates in tension or compression. A web side plate, welded to the column and bolted to the beam web, reprend l'effort tranchant. Because the field joint is bolted, the beam can be erected without site welding.

It is a rigid connection, donc COMME 4100 Clause 9.1.4 asks for a minimum design moment as well as the design actions from the analysis. The other AS 4100 moment connections in the module do the same job with an end plate welded to the beam. Vous pouvez vérifier celui-ci directement dans le calculateur de connexion de plaque à bride.

In this example each flange plate has four rows of two bolts, avec un 75 mm pitch along the beam and a 110 mm gauge across it.

Élévation d'un assemblage encastré par plaques de semelle: 460 UB 74.6 bolted to 25 mm flange plates welded to a 310 UC 158 bride

Élévation de l'exemple de connexion. The flange plates are welded to the column flange with 10 mm fillets, and the web side plate carries the shear.

Section A-A plan of the 25 mm Gr.300 flange plate with eight M20 8.8/S bolts at 75 pas de mm et 110 calibre en mm

Section A-A, a plan of the flange plate. The first bolt row is 70 mm from the face of the column.

SkyCiv Connection Design 3D view of the flange plate moment connection between a 460 UB 74.6 et un 310 UC 158

La même connexion dans la vue 3D de SkyCiv Connection Design.

Flange plate moment connection design: les étapes en un coup d'œil

  1. Vérifiez les limites de détail de la plaque à bride: pas, jauge, edge distances and weld size.
  2. Définir le moment du design, pas moins que la clause 9.1.4 le minimum, trouver les forces de la bride, and check the bolts in shear.
  3. Check the bolts in bearing on the flange plate and the beam flange.
  4. Check the weld of the flange plate to the column.
  5. Check block shear of the flange plate and of the beam flange.
  6. Check the flange plate in tension and in compression, and the beam flange in tension.
  7. Check the section moment capacity of the beam at the flange bolt holes.
  8. Check the column flange and web at the flange plate.
  9. Check the web side plate shear connection: les dispositions constructives, souder, boulons, plate and beam web.

Entrées de conception pour cet exemple

Le code de conception est AS 4100:2020, avec les propriétés de section de la base de données de sections australienne. La limite d'élasticité de chaque pièce suit sa nuance et son épaisseur: 300 MPa pour le faisceau, 280 MPa pour la colonne avec son 25 mm bride, 280 MPa pour le 25 mm flange plate and 310 MPa pour le 10 mm web side plate.

ArticleSymboleValeur
Cisaillement (AF)[mathin] V^{*} [mathin]80 kN
Axial (Effets), envelope[mathin] N^{*}_{t},\ N^{*}_{c} [mathin]60 kN tension / 90 kN compression
Moment de l'axe majeur (Mz)[mathin] M^{*}_{x} [mathin]70 kNm
Beam460 UB 74.6, AS / NZS 3679.1 Gr.300
Profondeur du faisceau / épaisseur de l'âme[mathin] d_{bm},\ t_{wb} [mathin]457 mm / 9.1 mm
Largeur de l'aile de la poutre / thickness[mathin] b_{fb},\ t_{fb} [mathin]190 mm / 14.5 mm
Surface du faisceau / module de section plastique[mathin] A_{bm},\ S_{x} [mathin]9520 mm² / 1.66 x 10⁶mm³
Rendement du faisceau / résistance à la traction[mathin] f_{yb},\ f_{ub} [mathin]300 MPa / 440 MPa
Poteau310 UC 158, AS / NZS 3679.1 Gr.300
Profondeur de colonne / épaisseur de l'âme[mathin] d_{sup},\ t_{ws} [mathin]327 mm / 15.7 mm
Largeur de l'aile du poteau / thickness[mathin] b_{fs},\ t_{fs} [mathin]311 mm / 25 mm
Rayon de racine de colonne[mathin] r_{s} [mathin]16.5 mm
Rendement de la colonne / résistance à la traction[mathin] f_{ys},\ f_{us} [mathin]280 MPa / 440 MPa
Module élastique[mathin] E [mathin]200000 MPa
Plaques de semelle (top and bottom)SymboleValeur
Plaque de semellePL 25 X 210 X 345, AS / NZS 3678 Gr.300
Largeur de plaque / longueur / thickness[mathin] b_{p},\ l_{p},\ t_{p} [mathin]210 mm / 345 mm / 25 mm
Rendement des plaques / résistance à la traction[mathin] f_{yp},\ f_{up} [mathin]280 MPa / 430 MPa
Bolts to the beam flangeM20 8.8/S, filetages inclus dans le plan de cisaillement
Diamètre du boulon / résistance à la traction minimale[mathin] d_{ff},\ f_{uf} [mathin]20 mm / 830 MPa
Holes in plate and beam flange[mathin] d_{h} [mathin]Nominal, 22 mm
Rangées de boulons / pas de rangée[mathin] n_{p},\ s_{p} [mathin]4 / 75 mm
Colonnes de boulons / jauge[mathin] n_{g},\ s_{g} [mathin]2 / 110 mm
Support face to first bolt row[mathin] l [mathin]70 mm
Edge distances on plate (fin / côté)[mathin] l_{ev\_fp},\ l_{eh\_fp} [mathin]50 mm / 50 mm
Edge distances on beam flange (fin / côté)[mathin] l_{ev\_f},\ l_{eh\_f} [mathin]40 mm / 50 mm
Souder à la bride de colonne10 Filet mm, E49XX, PS
Taille de soudure / résistance du métal soudé[mathin] t_{wf},\ f_{uw} [mathin]10 mm / 490 MPa
Plaque latérale WebSymboleValeur
Plaque latérale WebPL 10 X 120 X 325, AS / NZS 3678 Gr.300
Rendement des plaques / résistance à la traction[mathin] f_{yp},\ f_{up} [mathin]310 MPa / 430 MPa
Boulons4 x M20 8.8/S in one column, 75 pas en mm
Edge distances on plate / on beam web[mathin] l_{ev\_wp},\ l_{eh\_wp},\ l_{eh\_w} [mathin]50 mm / 50 mm / 50 mm
Beam end clearance / first bolt column[mathin] clr,\ l [mathin]20 mm / 70 mm
Excentricité du groupe de boulons[mathin] e_{b} [mathin]70 mm
Souder à la bride de colonne10 mm filet des deux côtés, E49XX, PS

The axial load is entered as an envelope, 60 kN in tension and 90 kN in compression. The two are separate cases, so the tension checks use the tension and the compression checks use the compression, and neither relieves the other.

Étape 1: Limites des détails des plaques à bride (AS 4100 Clause 9.5)

The bolt layout on the flange plate and the beam flange has to be buildable and match the assumptions behind the capacity equations. Le pas minimum est [mathin] 2.5\, d_{f} = 2.5 \times 20\ \text{mm} = 50\ \text{mm} [mathin] (Clause 9.5.1), and the minimum edge distance for an M20 bolt is 35 mm, [mathin] 1.75\, d_{f} [mathin] du tableau 9.5.2. The minimum fillet weld for the 25 mm plate on the 25 mm column flange is 6 mm (Tableau 9.6.3.2).

Limite de détailLimite (mm)Réel (mm)DCRRésultat
Pas minimum de rangée de boulons sur la plaque à bride50.00075.0000.667cdot K_a
Pas maximal de rangée de boulons sur la plaque à bride158.00075.0000.475cdot K_a
Pas minimum de colonne de boulon sur la plaque à bride50.000110.0000.455cdot K_a
Pas maximal de la colonne de boulon sur la plaque à bride200.000110.0000.550cdot K_a
Minimum bolt gauge on beam flange71.900110.0000.654cdot K_a
Distance minimale du bord vertical sur la plaque à bride35.00050.0000.700cdot K_a
Distance minimale du bord vertical sur l'aile de la poutre35.00040.0000.875cdot K_a
Distance minimale du bord horizontal sur la plaque à bride35.00050.0000.700cdot K_a
Distance minimale du bord horizontal sur l'aile de la poutre35.00050.0000.700cdot K_a
Distance maximale au bord150.00050.0000.333cdot K_a
Minimum fillet weld size at flange plate to column flange6.00010.0000.600cdot K_a

Pour une limite minimale, le rapport est la limite sur la valeur réelle, et pour un maximum, c'est un dépassement réel de la limite. The governing row is the end distance on the beam flange, from the last bolt row to the end of the beam:

[math] DCR = \frac{35\ \text{mm}}{40\ \text{mm}} = 0.875 [math]

DCR = 0.875 ≤ 1.0, d'accord

Étape 2: Groupe de boulons en cisaillement (AS 4100 Clauses 9.1.4, 9.2.2.1, 9.3.1)

Moment de calcul et forces de bride

La connexion est rigide, donc la clause 9.1.4 sets the design moment at not less than half the design section moment capacity of the beam:

[math] M^{*} = \max\left( M^{*}_{x},\ 0.5\, \phi\, f_{yb}\, S_{x} \right) = \max\left( 70\ \text{kNm},\ 0.5 \times 0.9 \times (300\ \text{MPa}) \times (1.66 \times 10^{6}\ \text{mm}^{3}) \right) = 224.1\ \text{kNm} [math]

Le 70 kNm from the analysis is below the minimum, donc 224.1 kNm is used for every flange check. The moment is split into a flange force pair over the distance between the flange centres, and half the axial load is added to each flange:

[math] N^{*}_{f} = \frac{M^{*}}{d_{bm} – t_{fb}} + \frac{\max\left( N^{*}_{t},\ N^{*}_{c} \right)}{2} = \frac{224.1\ \text{kNm}}{457\ \text{mm} – 14.5\ \text{mm}} + \frac{90\ \text{kN}}{2} = 551.44\ \text{kN} [math]

With the envelope taken case by case, the force in the tension flange is [mathin] N^{*}_{ft} = 536.44\ \text{kN} [mathin] (avec le 60 kN tension) and the force in the compression flange is [mathin] N^{*}_{fc} = 551.44\ \text{kN} [mathin] (avec le 90 kN compression). The bolts, welds and block shear take the larger force, 551.44 kN.

Bolt capacity

The bolted length along the force is [mathin] l_{j} = (n_{p} – 1)\, s_{p} = 3 \times 75\ \text{mm} = 225\ \text{mm} [mathin], inférieur à 300 mm, so the lap connection factor [mathin] k_{r} = 1 [mathin] (Clause 9.2.2.1). Les filetages sont dans le seul plan de cisaillement, donc la zone centrale est utilisée:

[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, k_{rd}\, k_{r}\, \left( n_{n} A_{c} + n_{x} A_{o} \right) [math]

[math] \phi V_{f} = (0.8) \times 0.62 \times (830\ \text{MPa}) \times (1) \times (1) \times \left( (1)(225\ \text{mm}^{2}) + (0)(314.16\ \text{mm}^{2}) \right) = 92.628\ \text{kN} [math]

The flange force is concentric with the bolt group, so all eight bolts share it (Clause 9.3.1):

[math] \phi V_{df} = n_{b}\, \phi V_{f} = 8 \times (92.628\ \text{kN}) = 741.02\ \text{kN} [math]

[math] N^{*}_{f} = 551.44\ \text{kN} \le \phi V_{df} = 741.02\ \text{kN} [math]

DCR = 551.44 kN / 741.02 kN = 0.744 ≤ 1.0, d'accord

Étape 3: Bolt group in bearing on the flange plate and the beam flange (AS 4100 Clause 9.2.2.4)

Each bolt bears on the flange plate and on the beam flange. The end bolts are limited by the distance to the end of the ply, and the inner bolts by the distance to the next hole. Pour la plaque à bride, avec [mathin] d_{h} = 22\ \text{mm} [mathin]:

[math] a_{e1} = l_{eh\_fp} – 0.5\, d_{h} + 0.5\, d_{f} = (50\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 49\ \text{mm} [math]

[math] a_{e2} = s_{p} – d_{h} + 0.5\, d_{f} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

The bearing capacity of a ply, avec un facteur de capacité de 0.9:

[math] \phi V_{b} = \phi \min\left( 3.2\, d_{f}\, t_{p}\, f_{up},\ a_{e}\, t_{p}\, f_{up} \right) [math]

Pour le 25 mm plate this gives 474.07 kN at each end bolt and 609.52 kN at each inner bolt. Each bolt column has one end bolt and three inner bolts:

[math] \phi V_{b,pl} = 2 \left[ 474.07\ \text{kN} + 3 \times (609.52\ \text{kN}) \right] = 4605.3\ \text{kN} [math]

Le 14.5 bride de poutre de mm, avec son 440 Résistance à la traction MPa, donne 281.36 kN at each end bolt and 361.75 kN at each inner bolt:

[math] \phi V_{b,beam} = 2 \left[ 281.36\ \text{kN} + 3 \times (361.75\ \text{kN}) \right] = 2733.2\ \text{kN} [math]

[math] \phi V_{b} = \min\left( 4605.3\ \text{kN},\ 2733.2\ \text{kN} \right) = 2733.2\ \text{kN} [math]

DCR = 551.44 kN / 2733.2 kN = 0.202 ≤ 1.0, d'accord

Étape 4: Weld of the flange plate to the column (AS 4100 Clause 9.6.3.10)

The flange force passes from the plate into the column flange through the fillet welds across the plate width. La soudure est à des fins structurelles (PS), donc le facteur de capacité est 0.8 du tableau 3.4:

[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{wf}\, k_{r} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (10\ \text{mm}) \times (1) = 1.6631\ \text{kN/mm} [math]

The weld length is the plate width, not more than the column flange width: [mathin] l_{w} = \min\left( b_{p},\ b_{fs} \right) = \min\left( 210\ \text{mm},\ 311\ \text{mm} \right) = 210\ \text{mm} [mathin]. The plate is welded on both faces:

[math] \phi N_{w} = 2\, l_{w}\, \phi v_{w} = 2 \times (210\ \text{mm}) \times (1.6631\ \text{kN/mm}) = 698.51\ \text{kN} [math]

[math] N^{*}_{f} = 551.44\ \text{kN} \le \phi N_{w} = 698.51\ \text{kN} [math]

DCR = 551.44 kN / 698.51 kN = 0.789 ≤ 1.0, d'accord

C'est le test de force déterminant. The weld length is set by the plate width, so a larger fillet or a wider plate is the way to add capacity here.

Étape 5: Plaque à bride en cisaillement de bloc (AS 4100 Clause 9.1.9)

Un bloc de la plaque à bride peut se déchirer autour des boulons: shear along the bolt lines plus tension across them. Three patterns are checked. The capacity factor is 0.75 and the tension stress is uniform, donc [mathin] k_{bs} = 1 [mathin]:

[math] \phi R_{bs} = \phi \min\left( 0.6\, f_{up}\, A_{nv} + k_{bs}\, f_{up}\, A_{nt},\ 0.6\, f_{yp}\, A_{gv} + k_{bs}\, f_{up}\, A_{nt} \right) [math]

Motifs 1 et 2 shear along both bolt columns:

[math] A_{gv} = 2 \left[ l_{eh} + (n_{p} – 1)\, s_{p} \right] t_{p} = 13750\ \text{mm}^{2}, \qquad A_{nv} = 2 \left[ l_{eh} + (n_{p} – 1)\, s_{p} – (n_{p} – 0.5)\, d_{h} \right] t_{p} = 9900\ \text{mm}^{2} [math]

Modèle 1 tears across between the bolt columns, [mathin] A_{nt} = \left[ s_{g} – (n_{g} – 1)\, d_{h} \right] t_{p} = 2200\ \text{mm}^{2} [mathin], donner 2442 kN. Modèle 2 tears out to both side edges, [mathin] A_{nt} = (2\, l_{ev} – d_{h})\, t_{p} = 1950\ \text{mm}^{2} [mathin], donner 2361.4 kN. Modèle 3 is an L-shaped block along one bolt column and out to one side edge:

[math] A_{nt} = \left[ l_{ev} + (n_{g} – 1)\, s_{g} – (n_{g} – 0.5)\, d_{h} \right] t_{p} = 3175\ \text{mm}^{2}, \qquad A_{gv} = 6875\ \text{mm}^{2}, \qquad A_{nv} = 4950\ \text{mm}^{2} [math]

[math] \phi R_{bs} = \min\left( 2442\ \text{kN},\ 2361.4\ \text{kN},\ 1890.2\ \text{kN} \right) = 1890.2\ \text{kN} [math]

DCR = 551.44 kN / 1890.2 kN = 0.292 ≤ 1.0, d'accord

Étape 6: Aile de poutre en cisaillement de bloc (AS 4100 Clause 9.1.9)

On the beam flange, the block tears out along both bolt columns to the end of the beam and across to the two flange edges:

[math] A_{nt} = (2\, l_{ev\_f} – d_{h})\, t_{fb} = 841\ \text{mm}^{2}, \qquad A_{gv} = 2 \left[ 50\ \text{mm} + 3 \times 75\ \text{mm} \right] \times 14.5\ \text{mm} = 7975\ \text{mm}^{2}, \qquad A_{nv} = 5742\ \text{mm}^{2} [math]

[math] \phi R_{bs} = 1354.2\ \text{kN} [math]

DCR = 551.44 kN / 1354.2 kN = 0.407 ≤ 1.0, d'accord

Étape 7: Plaque à bride en tension (AS 4100 Clauses 9.1.10, 7.2, 7.3)

The tension flange plate carries the tension flange force. Its design section capacity is the lesser of yield on the gross area and fracture on the net area across a bolt row:

[math] A_{g} = b_{p}\, t_{p} = 5250\ \text{mm}^{2}, \qquad A_{n} = (b_{p} – n_{g}\, d_{h})\, t_{p} = 4150\ \text{mm}^{2} [math]

[math] \phi N_{t} = \phi \min\left( A_{g}\, f_{y},\ 0.85\, k_{t}\, A_{n}\, f_{u} \right) = 1323\ \text{kN} [math]

DCR = 536.44 kN / 1323 kN = 0.405 ≤ 1.0, d'accord

Étape 8: Plaque à bride en compression (AS 4100 Clauses 6.2.1, 6.2.2)

The compression flange plate carries the compression flange force. The bolt holes are filled by the bolts, so no reduction is made for them:

[math] \phi N_{s} = \phi\, k_{f}\, A_{g}\, f_{y} = 1323\ \text{kN} [math]

DCR = 551.44 kN / 1323 kN = 0.417 ≤ 1.0, d'accord

Étape 9: Aile de poutre en traction (AS 4100 Clauses 7.2, 7.3)

The beam flange itself carries the tension flange force into the bolts. With two holes across the flange:

[math] A_{g} = 2755\ \text{mm}^{2}, \qquad A_{n} = 2117\ \text{mm}^{2}, \qquad \phi N_{t} = 712.58\ \text{kN} [math]

DCR = 536.44 kN / 712.58 kN = 0.753 ≤ 1.0, d'accord

This is the second-highest strength ratio. The beam flange is thinner than the flange plate and loses two 22 mm holes from its 190 mm width.

Étape 10: Capacité de moment de section de la poutre au niveau des trous de bride (AS 4100 Clauses 5.2.6, 5.2, 8.3.2)

The bolt holes in the beam flanges reduce the beam section at the bolts. Clause 5.2.6 allows the holes to be ignored only when they remove a small enough part of the flange. Here they do not:

[math] \Delta A_{f} = \frac{100\, n_{g}\, d_{h}}{b_{fb}} = 23.158 > \Delta A_{lim} = 19.786 [math]

Les modules de section sont donc réduits du rapport entre la surface nette et la surface brute.. The net area deducts the flange holes:

[math] A_{n} = A – 2\, n_{g}\, d_{h}\, t_{fb} = 8244\ \text{mm}^{2} [math]

The section is compact under Clause 5.2.2 ([mathin] \lambda_{ef} = 6.8333 [mathin], [mathin] \lambda_{ew} = 51.522 [mathin]), so the effective section modulus is the reduced plastic modulus, plafonné à 1.5 times the reduced elastic modulus:

[math] S_{n} = \frac{A_{n}}{A} S_{x} = 1.4375 \times 10^{6}\ \text{mm}^{3}, \qquad Z_{n} = \frac{A_{n}}{A} Z_{x} = 1.2479 \times 10^{6}\ \text{mm}^{3} [math]

[math] Z_{e} = \min\left( S_{n},\ 1.5\, Z_{n} \right) = 1.4375 \times 10^{6}\ \text{mm}^{3}, \qquad \phi M_{s} = \phi\, f_{y}\, Z_{e} = 388.13\ \text{kNm} [math]

The axial load reduces the moment capacity (Clause 8.3.2). In tension, the net area also deducts the holes of the nearest web bolt column, [mathin] A_{nw} = 7443.2\ \text{mm}^{2} [mathin], donner [mathin] \phi N_{t} = 2505.4\ \text{kN} [mathin], and the reduced capacity stays at 388.13 kNm. In compression, the effective area for local buckling is [mathin] A_{e} = 9027\ \text{mm}^{2} [mathin], donc [mathin] k_{f} = 0.94821 [mathin] et [mathin] \phi N_{s} = 2437.3\ \text{kN} [mathin]. Le 90 kN compression governs:

[math] \phi M_{rx} = \phi M_{s} \left( 1 – \frac{N^{*}_{c}}{\phi N_{s}} \right) = (388.13\ \text{kNm}) \times \left( 1 – \frac{90\ \text{kN}}{2437.3\ \text{kN}} \right) = 373.79\ \text{kNm} [math]

[math] M^{*} = 224.1\ \text{kNm} \le \phi M_{rx} = 373.79\ \text{kNm} [math]

DCR = 224.1 kNm / 373.79 kNm = 0.600 ≤ 1.0, d'accord

Étape 11: Supporting member at the flange plate (AS 4100 Clauses 5.11, 5.13)

Each flange plate delivers its force to one side of the column flange, so the column flange and web are checked locally. The flange plate is taken as at least [mathin] 10\, t_{fs} [mathin] from the column end, so no capacity is halved. The stiff bearing length is the plate thickness plus a weld leg each side, dispersed 1:1 à travers les soudures (Clause 5.13.1): [mathin] b_{s} = t_{p} + 2\, t_{wf} = 25\ \text{mm} + 2 \times 10\ \text{mm} = 45\ \text{mm} [mathin].

Column flange in local bending, at the tension flange plate:

[math] \phi R_{fb} = \phi\, 6.25\, t_{fs}^{2}\, f_{ys} = 984.38\ \text{kN} [math]

Column web in local yielding, at the tension flange plate:

[math] \phi R_{wy} = \phi\, f_{ys}\, t_{ws} \left[ 5 (t_{fs} + r_{s}) + b_{s} \right] = 999\ \text{kN} [math]

Column web in bearing yield, at the compression flange plate (Clause 5.13.3), with the bearing width dispersed through the column flange on both sides, [mathin] b_{bf} = b_{s} + 5\, t_{fs} = 170\ \text{mm} [mathin]:

[math] \phi R_{by} = \phi\, 1.25\, b_{bf}\, t_{ws}\, f_{ys} = 840.74\ \text{kN} [math]

Column web in crippling, avec [mathin] \phi = 0.75 [mathin]:

[math] \phi R_{wc} = \phi\, 0.8\, t_{ws}^{2} \left[ 1 + 3 \frac{b_{s}}{d_{sup}} \left( \frac{t_{ws}}{t_{fs}} \right)^{1.5} \right] \sqrt{\frac{E\, f_{ys}\, t_{fs}}{t_{ws}}} = 1683.5\ \text{kN} [math]

Column web in bearing buckling (Clauses 5.13.4 et 6.3.3). The web is a compression member over its clear depth [mathin] d_{1} = 277\ \text{mm} [mathin], with a bearing width of [mathin] b_{b} = 447\ \text{mm} [mathin] and an area of [mathin] A_{wb} = 7017.9\ \text{mm}^{2} [mathin]. Avec [mathin] l_{e}/r = 2.5\, d_{1}/t_{ws} = 44.108 [mathin], [mathin] \lambda_{n} = 46.68 [mathin] et [mathin] \alpha_{b} = 0.5 [mathin], the slenderness reduction factor is [mathin] \alpha_{c} = 0.82729 [mathin]:

[math] \phi R_{bb} = \phi\, \alpha_{c}\, k_{f}\, A_{wb}\, f_{ys} = 1463.1\ \text{kN} [math]

Panneau d'âme de poteau en cisaillement (Clauses 5.11.2 et 5.11.4). The panel is stocky, [mathin] d_{p}/t_{w} = 17.643 \le 77.483 [mathin], and its shear area is [mathin] A_{ws} = d_{sup}\, t_{ws} = 5133.9\ \text{mm}^{2} [mathin]:

[math] \phi V_{c} = \phi\, 0.6\, f_{ys}\, A_{ws} = (0.9) \times 0.6 \times (280\ \text{MPa}) \times (5133.9\ \text{mm}^{2}) = 776.25\ \text{kN} [math]

[math] \phi R_{n} = \min\left( 984.38,\ 999,\ 840.74,\ 1683.5,\ 1463.1,\ 776.25 \right)\ \text{kN} = 776.25\ \text{kN} [math]

DCR = 551.44 kN / 776.25 kN = 0.710 ≤ 1.0, d'accord

The panel shear governs the column. La connexion est unilatérale, so the whole flange force goes into the panel as shear.

Étape 12: Web side plate detailing limitations (AS 4100 Clause 9.5)

The web side plate is checked as its own shear connection, pour le 80 kN shear. Its layout is one column of four M20 bolts at 75 pas en mm.

Limite de détailLimite (mm)Réel (mm)DCRRésultat
Minimum bolt row pitch on web side plate50.00075.0000.667cdot K_a
Maximum bolt row pitch on web side plate136.40075.0000.550cdot K_a
Minimum vertical edge distance on web side plate35.00050.0000.700cdot K_a
Minimum horizontal edge distance on web side plate35.00050.0000.700cdot K_a
Distance minimale du bord horizontal sur l'âme de la poutre35.00050.0000.700cdot K_a
Minimum web side plate depth228.500325.0000.703cdot K_a
Maximum web side plate depth405.200325.0000.802cdot K_a
Dégagement minimum20.00020.0001.000cdot K_a
Distance maximale au bord109.20050.0000.458cdot K_a

La ligne directrice est le jeu entre l'extrémité de la poutre et la semelle du poteau., which was set at the 20 mm minimum:

DCR = 20 mm / 20 millimètre = 1.000 ≤ 1.0, d'accord

Étape 13: Minimum weld size of the web side plate (AS 4100 Clause 9.6.3)

The weld of the web side plate to the column is sized to develop the plate, taken by the program as three quarters of the plate thickness:

[math] 0.75\, t_{i} = 0.75 \times (10\ \text{mm}) = 7.5\ \text{mm} \le t_{ww} = 10\ \text{mm} [math]

DCR = 7.5 mm / 10 millimètre = 0.750 ≤ 1.0, d'accord

Étape 14: Weld of the web side plate to the column (AS 4100 Clauses 9.1.4, 9.6.3.10)

The minimum design shear for the shear connection (Clause 9.1.4) is the lesser of 0.15 times the beam’s shear capacity, [mathin] 0.15 \times 673.71\ \text{kN} [mathin], et 40 kN, donc 40 kN. Le 80 Le cisaillement kN est plus grand et est utilisé. The welds run the full 325 mm plate depth on both sides, with no eccentricity:

[math] \phi v_{w} = 1.6631\ \text{kN/mm}, \qquad \phi V_{w} = 2\, l_{w}\, \phi v_{w} = 2 \times (325\ \text{mm}) \times (1.6631\ \text{kN/mm}) = 1081\ \text{kN} [math]

DCR = 80 kN / 1081 kN = 0.074 ≤ 1.0, d'accord

Étape 15: Web side plate bolt group in shear (AS 4100 Clauses 9.2.2.1, 9.3.1)

The shear acts 70 mm à partir de la ligne de boulon, so the bolt group is analysed by the instantaneous centre of rotation (ICOR) méthode. The design shear capacity of one bolt is the same as in Step 2, [mathin] \phi V_{f} = 92.628\ \text{kN} [mathin]. The instantaneous centre is at [mathin] x_{ic} = -85.734\ \text{mm} [mathin], [mathin] y_{ic} = 112.5\ \text{mm} [mathin] du boulon 1, at the bottom of the bolt column:

VerrouillerX (mm)Y (mm)R (kN)Rx (kN)Ry (kN)
10.000.0090.9172.3155.11
20.0075.0087.1234.9179.81
30.00150.0087.12-34.9179.81
40.00225.0090.91-72.3155.11

[math] \phi V_{df} = \sqrt{ \left( \sum R_{x} \right)^{2} + \left( \sum R_{y} \right)^{2} } = \sqrt{ (0\ \text{kN})^{2} + (269.84\ \text{kN})^{2} } = 269.84\ \text{kN}, \qquad C = \frac{269.84\ \text{kN}}{92.628\ \text{kN}} = 2.9132 [math]

DCR = 80 kN / 269.84 kN = 0.296 ≤ 1.0, d'accord

Étape 16: Web side plate bolt group in bearing (AS 4100 Clause 9.2.2.4)

The least edge distance governs each ply. Dans l'assiette, [mathin] a_{e} = \min(49,\ 63,\ 49)\ \text{mm} = 49\ \text{mm} [mathin], and on the beam web, [mathin] a_{e} = \min(63,\ 49)\ \text{mm} = 49\ \text{mm} [mathin]:

[math] \phi V_{b,pl} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (10\ \text{mm}) \times (430\ \text{MPa}),\ (49\ \text{mm}) \times (10\ \text{mm}) \times (430\ \text{MPa}) \right) = 189.63\ \text{kN} [math]

[math] \phi V_{b,beam} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (9.1\ \text{mm}) \times (440\ \text{MPa}),\ (49\ \text{mm}) \times (9.1\ \text{mm}) \times (440\ \text{MPa}) \right) = 176.58\ \text{kN} [math]

[math] \phi V_{b} = \min\left( 189.63\ \text{kN},\ 176.58\ \text{kN} \right) \times (2.9132) = 514.4\ \text{kN} [math]

DCR = 80 kN / 514.4 kN = 0.156 ≤ 1.0, d'accord

Étape 17: Plaque latérale d'âme en cisaillement (AS 4100 Clause 5.11.3)

[math] \phi V_{v} = \phi\, 0.5\, f_{yp}\, d_{i}\, t_{i} = (0.9) \times 0.5 \times (310\ \text{MPa}) \times (325\ \text{mm}) \times (10\ \text{mm}) = 453.38\ \text{kN} [math]

DCR = 80 kN / 453.38 kN = 0.176 ≤ 1.0, d'accord

Étape 18: Platine latérale en flexion (AS 4100 Clause 5.2.1)

[math] \phi M_{s} = \phi\, \frac{f_{yp}\, t_{i}\, d_{i}^{2}}{4} = (0.9) \times \frac{(310\ \text{MPa}) \times (10\ \text{mm}) \times (325\ \text{mm})^{2}}{4} = 73.673\ \text{kNm} [math]

[math] \phi V_{n} = \frac{\phi M_{s}}{e_{b}} = \frac{73.673\ \text{kNm}}{70\ \text{mm}} = 1052.5\ \text{kN} [math]

DCR = 80 kN / 1052.5 kN = 0.076 ≤ 1.0, d'accord

Étape 19: Plaque latérale d'âme en cisaillement de blocs (AS 4100 Clause 9.1.9)

An L-shaped block tears out along the bolt column and across to the free edge of the plate:

[math] A_{nt} = 390\ \text{mm}^{2}, \qquad A_{gv} = 2750\ \text{mm}^{2}, \qquad A_{nv} = 1980\ \text{mm}^{2} [math]

[math] \phi R_{bs} = (0.75) \times \min\left( 0.6 \times (430)(1980) + (1)(430)(390),\ 0.6 \times (310)(2750) + (1)(430)(390) \right) \times 10^{-3} = 508.9\ \text{kN} [math]

DCR = 80 kN / 508.9 kN = 0.157 ≤ 1.0, d'accord

Étape 20: Membre supporté en cisaillement (AS 4100 Clause 5.11.2)

[math] \frac{d_{p}}{t_{w}} = 47.033 \le \frac{82}{\sqrt{f_{y} / 250}} = 74.855 [math]

[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (457\ \text{mm}) \times (9.1\ \text{mm}) = 673.71\ \text{kN} [math]

DCR = 80 kN / 673.71 kN = 0.119 ≤ 1.0, d'accord

Récapitulatif des contrôles

Vérification de la conceptionEffet d'action de conceptionCapacité de conceptionDCRRésultat
Raccordement par plaque à bride
Limites des détails de connexion35 mm40 mm0.875cdot K_a
Groupe de boulons en cisaillement551.441 kN741.024 kN0.744cdot K_a
Bolt group in bearing on flange plate and beam flange551.441 kN2733.19 kN0.202cdot K_a
Souder au membre de soutien551.441 kN698.508 kN0.789cdot K_a
Plaque à bride en cisaillement de bloc551.441 kN1890.19 kN0.292cdot K_a
Aile de poutre en cisaillement de bloc551.441 kN1354.15 kN0.407cdot K_a
Plaque à bride en tension536.441 kN1323 kN0.405cdot K_a
Plaque à bride en compression551.441 kN1323 kN0.417cdot K_a
Aile de poutre en traction536.441 kN712.582 kN0.753cdot K_a
Section moment capacity of beam at flange holes224.1 kNm373.794 kNm0.600cdot K_a
Membre bienfaiteur (colonne)551.441 kN776.246 kN0.710cdot K_a
Web side plate connection
Limites des détails de connexion20 mm20 mm1.000cdot K_a
Taille minimale de soudure7.5 mm10 mm0.750cdot K_a
Souder au membre de soutien80 kN1081.02 kN0.074cdot K_a
Groupe de boulons en cisaillement80 kN269.843 kN0.296cdot K_a
Groupe de boulons en appui sur l'âme de la plaque et de la poutre80 kN514.4 kN0.156cdot K_a
Plaque latérale d'âme en cisaillement80 kN453.375 kN0.176cdot K_a
Platine latérale en flexion80 kN1052.48 kN0.076cdot K_a
Plaque latérale d'âme en cisaillement de blocs80 kN508.905 kN0.157cdot K_a
Membre supporté en cisaillement80 kN673.709 kN0.119cdot K_a

La connexion passe tous les contrôles. The weld of the flange plate to the column governs the strength checks at 0.789, followed by the beam flange in tension at 0.753 and the bolt group in shear at 0.744. Every flange check uses the 224.1 kNm minimum design moment of Clause 9.1.4, pas le 70 kNm from the analysis. The web side plate detailing ratio is 1.000 because the beam end clearance was set at its 20 mm minimum, and that is not a strength check.

Auto Design is available for the flange plate moment connection in the AS 4100 module. Ça change les boulons, plates and welds until every check passes, et conserve vos membres et vos actions de conception telles que saisies. Voir le Conception automatique page pour l'AS 4100 préférences pour lesquelles il fonctionne.

Que changer si une vérification échoue

  • Limites des dispositions constructives: régler le ton, gauge or edge distances to the limits in Step 1. A short end distance on the beam flange can be fixed by moving the bolts along the plate.
  • Bolts in shear or bearing: ajouter une rangée de boulons, ou utilisez un boulon plus gros. If the beam flange governs bearing, increase its end distance or the pitch.
  • Flange plate weld: augmenter la taille du filet, or widen the plate where the column flange allows.
  • Block shear or plate tension and compression: utiliser une assiette plus épaisse ou plus large, or add a bolt row to lengthen the shear planes.
  • Beam flange in tension or beam section at the holes: utiliser une poutre plus lourde.
  • Column checks: utiliser une colonne plus lourde.
  • Plaque latérale Web: rendre la plaque plus profonde ou plus épaisse, ou ajouter des boulons, as for any web side plate shear connection.

Questions fréquentes

Why is the connection designed for 224.1 kNm when the moment is 70 kNm?

AS 4100 Clause 9.1.4 sets a minimum design action for a rigid connection: the design moment is not taken less than half the design section moment capacity of the beam. Pour un 460 UB 74.6 in Grade 300 c'est-à-dire 0.5 X 0.9 X 300 MPa x 1.66 x 10⁶ mm³ = 224.1 kNm. Le 70 kNm from the analysis is below it, so the minimum governs.

How are tension and compression handled when the axial load is an envelope?

Le 60 kN tension and the 90 kN compression are taken as separate cases. The tension flange checks add half the tension, and the compression flange checks add half the compression, so neither relieves the other. The bolts, welds and block shear take the larger of the two flange forces, 551.44 kN.

Why are the beam section moduli reduced at the bolt holes?

Clause 5.2.6 lets the holes in a flange be ignored only when they remove less than a set part of the flange area. Deux 22 mm trous dans un 190 mm flange give 23.158 contre une limite de 19.786, so the section moduli are reduced by the ratio of the net area to the gross area.

Why does the column web panel shear govern the column checks?

The beam frames into one side of the column only, so the full flange force enters the column web panel as shear. Le 310 UC 158 web is stocky, so the panel reaches shear yield at 776.25 kN, which is lower than the flange bending, plastification de l'âme, bearing and crippling capacities at the plate.

Does the web side plate carry any of the moment?

Non. The moment is carried by the flange plates as a force pair, and the web side plate is designed as a shear connection for the 80 kN shear, with its own Clause 9.1.4 minimum of 40 kN.

Why is the bearing capacity added up bolt by bolt?

The end bolts and the inner bolts have different tear-out distances. An end bolt tears out to the end of the ply, 49 mm here, and an inner bolt tears out to the next hole, 63 mm. Each bolt column has one end bolt and three inner bolts, so the group capacity is the sum of the two kinds, taken for the weaker ply.

Concevoir gratuitement un assemblage de moment de plaque à bride

Chaque numéro sur cette page provient d'une seule solution. Choisissez COMME 4100:2020 et la connexion du moment de la plaque à bride, entrez votre faisceau, colonne, plaques, boulons et charges, et voyez chacune de ces vérifications dans votre navigateur. Il n'y a rien à installer.

Le module SkyCiv Connection Design est le logiciel de conception de connexion derrière cet exemple. Il vous donne le rapport de calcul complet avec chaque équation et vos chiffres, comme les étapes ci-dessus, plus toutes les capacités de conception et DCR, pour AS 4100:2020 connexions de cisaillement, connexions et épissures de moment. Le calculateur de boulons et calculateur de soudure couvrir le groupe de boulons et les contrôles de soudure seuls.