To design a directly welded web connection between two channels to AISC 360, you check the fillet welds that join the beam web to the girder web against the beam end reaction. There is no plate and there are no bolts, so the design comes down to two things: a weld group that fits on the flat of the beam web and is at least the minimum size, and a weld that is strong enough once the base metal on both sides of it is accounted for.
Cette page fonctionne à travers un exemple du début à la fin: a C10x20 beam framing into the back of a C15x50 girder channel, avec un 25 kip LRFD reaction carried by 1/4 in E70XX fillet welds on both sides of the beam web, conçu pour AISC 360-16 et le manuel AISC 15e édition. Chaque équation est écrite avec ses chiffres, dans le même ordre que la feuille de calcul AISC, le SkyCiv Connection Design le module produit pour cela.
What is a channel to channel directly welded web connection?
It is a shear connection in which the end of a channel beam is welded straight to a channel girder, with no connecting element in between. The beam web butts against the girder and a fillet weld runs down each side of the beam web. It suits shop-assembled frames, platforms and secondary framing where channels are used for both members and a bolted field joint is not needed.
Cet exemple utilise l'orientation BBC, poutre à l'arrière du canal. The beam frames to the flat back of the girder’s web, sur le côté opposé à ses brides, so the beam needs no cope to clear them. L'autre orientation, BFC (faisceau vers l'avant du canal), place la poutre entre les ailes de la poutre.

Altitude du rapport de calcul: C10x20 beam welded to the back of a C15x50 girder channel

3Vue D de la connexion dans SkyCiv Connection Design
Conception de connexion Web directement soudée: les étapes en un coup d'œil
- Limites des dispositions constructives: check the minimum fillet weld size and that the welded depth fits on the flat of the beam web.
- Force de soudure: find the largest weld the base metal can develop, the effective weld length, and the design strength of the two fillet welds.
Entrées de conception pour cet exemple
| Article | Symbole | Valeur |
|---|---|---|
| Résistance au cisaillement requise (LRFD) | [mathin] V_{u} [mathin] | 25 kip |
| Beam | C10x20, ASTM A36 | |
| Profondeur du faisceau / épaisseur de l'âme | [mathin] d_{bm},\ t_{wb} [mathin] | 10 in / 0.379 in |
| Largeur de l'aile de la poutre / thickness | [mathin] b_{fb},\ t_{fb} [mathin] | 2.74 in / 0.436 in |
| Surface du faisceau | [mathin] A_{bm} [mathin] | 10 po² |
| Rendement du faisceau / contrainte de traction | [mathin] F_{yb},\ F_{ub} [mathin] | 36 ksi / 58 ksi |
| Poutre | C15x50, ASTM A36 | |
| Profondeur des poutres / épaisseur de l'âme | [mathin] d_{sup},\ t_{ws} [mathin] | 15 in / 0.716 in |
| Largeur de semelle de poutre / thickness | [mathin] b_{fs},\ t_{fs} [mathin] | 3.72 in / 0.65 in |
| Zone de poutres | [mathin] A_{sup} [mathin] | 14.7 po² |
| Rendement des poutres / contrainte de traction | [mathin] F_{ys},\ F_{us} [mathin] | 36 ksi / 58 ksi |
| Module d'élasticité | [mathin] E [mathin] | 29000 ksi |
| Souder | Symbole | Valeur |
|---|---|---|
| Électrode | E70XX | |
| Filler metal classification strength | [mathin] F_{EXX} [mathin] | 70 ksi |
| Fillet weld size, both sides of the beam web | [mathin] W [mathin] | 1/4 in (0.25 in) |
| Welded depth | [mathin] L_{d} [mathin] | 8 in |
Étape 1: Limites des détails de connexion (AISC 360-16 J2.2b)
The weld has to stay on the flat part of the beam web, clear of the flange-to-web fillets. The program takes the web lost at each flange as the larger of the design k distance and the cope depth. This beam has no copes, so each is 1 in.
[math] D_{max} = d_{det\_bm} – c_{t} – c_{b} = (10\ \text{in}) – (1\ \text{in}) – (1\ \text{in}) = 8\ \text{in} [math]
The welded depth of 8 in uses the full flat depth. The minimum fillet weld size of 3/16 in is the AISC 360-16 Table J2.4 value for the thinner part joined, l' 0.379 dans l'âme de la poutre. Le 4 in minimum connection depth is the software’s limit.
| Limite de détail | Limite (in) | Réel (in) | DCR | Résultat |
|---|---|---|---|---|
| Taille minimale de la soudure d'angle | 0.188 | 0.250 | 0.750 | cdot K_a |
| Profondeur de connexion minimale | 4.000 | 8.000 | 0.500 | cdot K_a |
| Profondeur de connexion maximale | 8.000 | 8.000 | 1.000 | cdot K_a |
DCR = 8 / 8 = 1.000 ≤ 1.0, d'accord
Étape 2: Design capacity of the weld (AISC 360-16 J2.4)
Limite de métal de base sur la taille de la soudure (Éq. manuel AISC. 9-2)
A fillet weld can be no stronger than the metal it is fused to. On the girder side the weld sits on the 0.716 dans l'âme des poutres. On the beam side the beam web carries a weld on each face, so each weld gets half of the 0.379 sur le Web, 0.1895 in. The smaller of the two products governs, expressed as a weld size in sixteenths of an inch:
[math] D_{max} = \frac{\min\left(t_{ws} F_{us},\ \frac{t_{wb}}{2} F_{ub}\right)}{3.09\ \text{kip/in} \times F_{EXX}/F_{E70XX}} = \frac{\min\left((0.716\ \text{in})(58\ \text{ksi}),\ (0.1895\ \text{in})(58\ \text{ksi})\right)}{(3.09\ \text{kip/in}) \times (1)} = 3.557 [math]
The beam web governs. A weld of 3.557 sixteenths is [mathin] 3.557/16 = 0.222 [mathin] in, which is smaller than the 1/4 en soudure, so the strength equation below uses the 0.222 in size the beam web can develop.
Longueur de soudure efficace (Partie du manuel AISC 10)
Each of the two welds runs the 8 in welded depth, less two weld sizes for the ends:
[math] L_{w} = 2 \left[ L_{d} – 2W \right] = 2 \times \left[ (8\ \text{in}) – 2 \times (0.25\ \text{in}) \right] = 15\ \text{in} [math]
Force de soudure (Eq. J2-4)
Avec [mathin] \phi = 0.75 [mathin] and the load parallel to the welds ([mathin] \theta_{u} = 0 [mathin]):
[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left(W,\ \frac{D_{max}}{16}\right) \left[1 + 0.5 \left(\sin \theta_{u}\right)^{1.5}\right] L_{w} [math]
[math] \phi R_{n} = (0.75) \times 0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left(0.25\ \text{in},\ \frac{3.557}{16}\right) \times \left[1 + 0.5 \times (\sin 0)^{1.5}\right] \times (15\ \text{in}) = 74.275\ \text{kip} [math]
[math] V_{u} = 25\ \text{kip} \le \phi R_{n} = 74.275\ \text{kip} [math]
DCR = 25 kip / 74.275 kip = 0.337 ≤ 1.0, d'accord
Récapitulatif des contrôles
| Vérifier | Demande | Capacité | DCR | Résultat |
|---|---|---|---|---|
| Limites des détails de connexion | 8 in | 8 in | 1.000 | cdot K_a |
| **Design capacity of weld** | **25 kiffer** | **74.275 kiffer** | **0.337** | **PASSER** |
The connection passes both checks. Le rapport de détail de 1.000 is not a strength ratio: it shows that the 8 in weld uses the whole flat of the C10x20 web, which is the most this beam allows. The weld is the governing strength check at 0.337, and its strength is limited by the thin beam web rather than by the 1/4 in weld itself.
Auto Design is available for the channel to channel directly welded web connection. Il modifie les variables de conception de la connexion jusqu'à ce que chaque vérification soit réussie, et conserve vos membres et vos charges tels qu'ils ont été saisis. Voir le Conception automatique page pour les préférences sur lesquelles il fonctionne.
Que changer si une vérification échoue
- Profondeur de connexion maximale: the welded depth cannot be more than the flat of the beam web, ici 8 in. If you need more weld, use a deeper beam or a connection with a plate or angles.
- Taille minimale de la soudure d'angle: use at least the Table J2.4 minimum for the thinner part joined, ici 3/16 in.
- Force de soudure: lengthen the weld up to the maximum depth first. A larger weld only helps until it reaches the base metal limit. In this example the beam web already limits the effective size to 0.222 in, donc un 5/16 in weld would add no strength. Past that point, use a beam with a thicker web or a connection with a plate or angles.
Questions fréquentes
Why is the effective weld size 0.222 in when the weld is 1/4 in?
Éq. manuel AISC. 9-2 limits the weld to what the base metal can develop in shear. L'âme de la poutre est 0.379 in thick and has a weld on each face, so each weld is matched against half of it. That half-web can only develop a weld of 3.557 seizièmes, 0.222 in, and the extra size of the 1/4 in weld is not counted.
Why is the weld length 15 in when the welded depth is 8 in?
There are two welds, un de chaque côté de l'âme de la poutre. Each is 8 in long less two weld sizes for the ends, 7.5 in, so the total effective length is 15 in.
Que signifie la BBC?
La BBC est diffusée à l'arrière du canal. The beam frames to the flat back of the girder channel’s web, loin de ses brides. Dans BFC, faisceau vers l'avant du canal, les cadres de poutres entre les ailes des poutres.
Is the girder web checked?
The girder web enters the design through the base metal check of Step 2, where its 0.716 in thickness is compared with the beam web’s half thickness. In this example the beam web is the weaker of the two, so it sets the weld strength.
Comment cela changerait-il pour ASD au lieu de LRFD?
Les équations sont les mêmes. The program uses the ASD safety factor in place of the LRFD resistance factor and compares the result with the ASD required strength.
Concevez gratuitement une connexion web directement soudée
Chaque numéro sur cette page provient d'une seule solution. Pick the channel to channel category and the directly welded web configuration, entrez votre faisceau, poutre, soudure et réaction, et voyez chacune de ces vérifications dans votre navigateur. Il n'y a rien à installer.
Le module SkyCiv Connection Design est le logiciel de conception de connexion derrière cet exemple. Il vous donne le rapport de calcul complet avec chaque équation et vos chiffres, comme les étapes ci-dessus, plus toutes les capacités et DCR, selon AISC 360-22 et AISC 360-16 (LRFD et TSA) et AS 4100:2020. Le calculateur de soudure covers the weld checks on their own.
Références
- AISC 360-16, Spécification pour les bâtiments en acier de construction: J2.2b (Tableau J2.4), J2.4 (Eq. J2-4).
- Manuel de construction en acier AISC, 15e édition: Partie 9, Eq. 9-2; Partie 10, longueur de soudure efficace.
- Conception d'assemblages en acier utilisant AISC 360-16
- Soudures dans la conception de connexion SkyCiv
Harold Munalem
Chef de produit, Connection Design
10+ années dans la conception d'assemblages en acier
LinkedIn