To design a bolted flange plate moment connection to a rectangular HSS column to AISC 360-16, you turn the beam moment into a tension and compression force in each flange, vérifier les plaques à bride, bolts and beam flanges for that force, and then check what the force does to the tube: the weld to the HSS face, local yielding of the plate on a flexible wall, and local yielding of the HSS sidewalls. A single plate on the beam web carries the shear.
This page works through one example: a W18x50 beam framing into the 4 in face of an HSS8x4x1/2 column, avec 38 kip-ft de moment, 19 cisaillement et 66 kip axial under LRFD, 3/4 in Grade 50 flange plates on four 1 en boulons A490-SC chacun, et un 3/8 in A36 shear plate. Chaque équation est écrite avec ses chiffres, dans le même ordre que la feuille de calcul, SkyCiv Connection Design le module produit pour cela.
What is a flange plate moment connection to an HSS column?
A flange plate assemblage résistant au moment has one plate on the top flange and one on the bottom flange of the beam. Each plate is shop-welded to the column and field-bolted to the beam flange, so the moment passes through the plates as a tension and compression couple. A shear plate on the web takes the beam reaction. For a W-shape column the plates weld to the column flange, as in Comment concevoir une connexion par moment avec plaque à bride.
On an HSS column the plates weld straight onto the tube wall, which is much more flexible than a column flange. A plate pulling on the middle of a thin wall cannot spread its force evenly across its width, so AISC reduces the plate to an effective width, and the sidewalls of the tube are checked for the force coming in from the corners. Those HSS checks are the part of the design this page adds to the W-shape example.
You can run this connection in the calculateur de connexion de plaque à bride.

Élévation de l'exemple de connexion. The flange plates are welded to the HSS face and bolted to the beam flanges; the shear plate carries the reaction.

Section A-A, a plan cut through the top flange plate, showing the four bolts at a 3 5/8 in gage and the plate against the 4 in HSS face.

3Vue D de la connexion dans SkyCiv Connection Design.
How do you design a flange plate moment connection to an HSS column? Les étapes en un coup d'œil
The report has two sections: the flange plates (Étapes 1 à 14) and the shear plate (Étapes 15 à 24).
- Limites de détail au niveau de l'aile de la poutre.
- Flange bolts in slip under the flange force.
- Bolt bearing on the flange plate.
- Bolt bearing on the beam flange.
- Cisaillement du bloc de la plaque à bride.
- Cisaillement de bloc de la semelle de poutre.
- Cèdement à la traction et rupture de la plaque à bride.
- Tension rupture of the beam flange.
- Rupture par flexion de la poutre au niveau des trous de boulons de la bride.
- Compression of the flange plate.
- Detailing limit at the HSS face.
- Fillet weld from the flange plate to the HSS face.
- Local yielding of the flange plate on the HSS wall.
- Local yielding of the HSS sidewalls.
- Detailing limits of the shear plate at the beam.
- Shear plate bolt group.
- Bearing on the shear plate.
- Appui sur l'âme de la poutre.
- Résistance effective du groupe de boulons d'âme.
- Block shear of the shear plate.
- Shear yielding and rupture of the shear plate.
- Detailing limits of the shear plate at the HSS wall.
- Weld from the shear plate to the HSS wall.
- Poinçonnage mural HSS.
Entrées de conception pour cet exemple
Le code de conception est AISC 360-16 LRFD. Les propriétés de la section proviennent du manuel AISC. How the loads are entered is explained in charges et combinaisons de charges.
| Article | Symbole | Valeur |
|---|---|---|
| Moment pris en compte (selon l'axe fort) | [mathin] M_{ux} [mathin] | 38 kip-ft |
| Cisaillement pondéré | [mathin] V_{u} [mathin] | 19 kip |
| Tension axiale pondérée / compression | [mathin] T_{u},\ C_{u} [mathin] | 66 kip / 66 kip |
| Beam | L18x50, ASTM A992 | |
| Profondeur du faisceau / épaisseur de l'âme | [mathin] d_{bm},\ t_{wb} [mathin] | 18 in / 0.355 in |
| Largeur de l'aile de la poutre / thickness | [mathin] b_{fb},\ t_{fb} [mathin] | 7.5 in / 0.57 in |
| Surface du faisceau / plastification / résistance à la traction | [mathin] A,\ F_{yb},\ F_{ub} [mathin] | 14.7 po² / 50 ksi / 65 ksi |
| Poteau | HSS8x4x1/2, ASTM A500 Gr. C | |
| Width of the HSS face the plates weld to | [mathin] b [mathin] | 4 in |
| Profondeur HSS / épaisseur de paroi de conception | [mathin] h,\ t [mathin] | 8 in / 0.465 in |
| Workable flat of the face | [mathin] W_{flat} [mathin] | 2.875 in |
| Rendement de la colonne / résistance à la traction | [mathin] F_{ys},\ F_{us} [mathin] | 50 ksi / 62 ksi |
| Flange plate item | Symbole | Valeur |
|---|---|---|
| Plaques de semelle | PL 3/4 X 6 1/2 X 6 1/2, ASTM A572 Gr.. 50 (50 / 65 ksi) | |
| Largeur de plaque / longueur / thickness | [mathin] b_{fp},\ L_{fp},\ t_{fp} [mathin] | 6.5 in / 6.5 in / 0.75 in |
| Boulons à bride | 1 en A490-SC, Classe A, 1 plan de cisaillement | |
| Trous | Plaque de semelle: surdimensionné (OVS). Bride de poutre: nommée (MST) | |
| Lignes de boulons / jauge | [mathin] n_{r},\ g_{a} [mathin] | 2 / 3.625 in |
| Bolts per line / espacement | [mathin] n_{c},\ s_{c} [mathin] | 2 / 3 in |
| Distances aux bords des plaques, à travers / le long de la poutre | [mathin] L_{ev\_fp},\ L_{eh\_fp} [mathin] | 1.4375 in / 1.5 in |
| Beam flange edge distances, à travers / along | [mathin] L_{ev\_bf},\ L_{eh\_bf} [mathin] | 1.9375 in / 1.5 in |
| Erection gap | 1/4 in | |
| Weld to HSS face | 1/2 en filet, E70XX |
| Shear plate item | Symbole | Valeur |
|---|---|---|
| Shear plate | PL 3/8 X 3 1/2 X 9, ASTM A36 (36 / 58 ksi) | |
| Boulons d'âme | 1 en A490-N, fils inclus | |
| Trous | assiette: horizontale à fente courte (CSSS). Toile de poutre: nommée (MST) | |
| Rangées de boulons / espacement / poteaux | [mathin] n_{r},\ s_{r},\ n_{c} [mathin] | 3 / 3 in / 1 |
| Edge distances / weld to bolt line | [mathin] L_{e},\ a [mathin] | 1.5 in / 2 in |
| Weld to HSS face | 3/16 en filet des deux côtés, E70XX |
Flange plate section
Étape 1: Limites de détail au niveau de l'aile de la poutre (AISC 360-16 J3.3, J3.4)
The bolt gage across the flange, the spacing along it and the edge distances on both the plate and the beam flange are checked against the J3.3 and Table J3.4 limits for a 1 en boulon, with the oversized-hole increment on the plate.
| Limite de détail | Limite (in) | Réel (in) | DCR | Résultat |
|---|---|---|---|---|
| Jauge minimale | 3.625 | 3.625 | 1.000 | cdot K_a |
| Espacement minimum des colonnes de boulons | 2.667 | 3.000 | 0.889 | cdot K_a |
| Espacement maximal des colonnes de boulons | 6.000 | 3.000 | 0.500 | cdot K_a |
| Distance minimale du bord vertical de la plaque | 1.375 | 1.438 | 0.956 | cdot K_a |
| Distance minimale du bord horizontal de la plaque | 1.375 | 1.500 | 0.917 | cdot K_a |
| Distance minimale du bord vertical de l'aile de poutre | 1.250 | 1.938 | 0.645 | cdot K_a |
| Distance minimale du bord horizontal de l'aile de poutre | 1.250 | 1.500 | 0.833 | cdot K_a |
The gage equals the module’s minimum gage, so that row sits at exactly 1.000:
[math] DCR = \frac{3.625\,in}{3.625\,in} = 1.000 [math]
DCR = 1.000, d'accord
Étape 2: Flange bolts in slip under the flange force (AISC 360-16 J3.8)
The moment becomes a force in each flange over the distance between flange centers, and half the axial force is added to it:
[math] P_{uF} = \frac{M_{ux}}{d_{bm} – t_{fb}} + \frac{P_{u}}{2} = \frac{38\,kip\text{-}ft}{18\,in – 0.57\,in} + \frac{66\,kip}{2} = 59.162\,kip [math]
This flange force is the demand for every check in the flange plate section. The four bolts are slip-critical, Eq. J3-4, with the report’s filler factor of 0.85:
[math] \phi R_{n} = \phi\, \mu\, D_{u}\, h_{f}\, T_{b}\, N_{s}\, n_{r}\, n_{c} = (0.85) \times (0.3) \times (1.13) \times (0.85) \times (64\,kip) \times (1) \times (2) \times (2) = 62.701\,kip [math]
DCR = 59.162 kip / 62.701 kip = 0.944 < 1.0, d'accord
Étape 3: Bolt bearing on the flange plate (AISC 360-16 J3.10)
The force runs along the beam, so the bolts bear toward the plate end. Avec le 1.25 in oversized hole:
[math] l_{c1} = 1.5 – \frac{1.25}{2} = 0.875\,in, \qquad l_{c2} = 3 – 1.25 = 1.75\,in [math]
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.875, 2.4) \times 0.75 \times 65 \times 2 + \min(1.2 \times 1.75, 2.4) \times 0.75 \times 65 \times 2 \times 1 \right] = 230.34\,kip [math]
DCR = 59.162 kip / 230.34 kip = 0.257 < 1.0, d'accord
Étape 4: Bolt bearing on the beam flange (AISC 360-16 J3.10)
[math] l_{c1} = 1.5 – \frac{1.125}{2} = 0.9375\,in, \qquad l_{c2} = 1.875\,in [math]
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.57 \times 65 \times 2 + \min(1.2 \times 1.875, 2.4) \times 0.57 \times 65 \times 2 \times 1 \right] = 187.57\,kip [math]
DCR = 59.162 kip / 187.57 kip = 0.315 < 1.0, d'accord
Étape 5: Cisaillement du bloc de la plaque à bride (AISC 360-16 J4.3)
Three tear-out shapes are checked, all with [mathin] U_{bs} = 1 [mathin] et l'Éq. J4-5:
[math] \phi R_{n} = \phi \left( 0.6 F_{up} A_{nv} + U_{bs} F_{up} A_{nt} \le 0.6 F_{yp} A_{gv} + U_{bs} F_{up} A_{nt} \right) [math]
| Modèle | Agv (po²) | Anv (po²) | Ant (po²) | phi Rn (kip) |
|---|---|---|---|---|
| L: un plan de cisaillement, tension à travers les boulons jusqu'à un bord | 3.375 | 1.8984 | 2.3203 | 168.64 |
| U: deux plans de cisaillement, tension entre les lignes de boulons | 6.75 | 3.7969 | 1.7344 | 195.61 |
| 2L: deux plans de cisaillement, tension de chaque ligne de boulons jusqu'à son bord | 6.75 | 3.7969 | 1.1719 | 168.19 |
For the governing 2L pattern:
[math] A_{nt} = 2 \times 0.75 \left[ 1.4375 – 0.5 \times (1.25 + 0.0625) \right] = 1.1719\,in^{2} [math]
[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.7969 + 65 \times 1.1719 \le 0.6 \times 50 \times 6.75 + 65 \times 1.1719 \right) = 168.19\,kip [math]
DCR = 59.162 kip / 168.19 kip = 0.352 < 1.0, d'accord
Étape 6: Cisaillement de bloc de la semelle de poutre (AISC 360-16 J4.3)
The beam flange tears out as two outer strips:
[math] A_{nt} = 0.57 \left[ 7.5 – 3.625 – 1 \times (1.1875) \right] = 1.5319\,in^{2} [math]
[math] A_{gv} = 2 \times 0.57 \left[ 1.5 + 3 \right] = 5.13\,in^{2}, \qquad A_{nv} = 2 \times 0.57 \left( 4.5 – 1.5 \times 1.1875 \right) = 3.0994\,in^{2} [math]
[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.0994 + 65 \times 1.5319 \le 0.6 \times 50 \times 5.13 + 65 \times 1.5319 \right) = 165.34\,kip [math]
DCR = 59.162 kip / 165.34 kip = 0.358 < 1.0, d'accord
Étape 7: Cèdement à la traction et rupture de la plaque à bride (AISC 360-16 J4.1)
[math] \phi R_{n\_ty} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]
[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.75 \left[ 6.5 – 2 \times (1.3125) \right] = 141.68\,kip [math]
DCR = 59.162 kip / 141.68 kip = 0.418 < 1.0, d'accord
Étape 8: Tension rupture of the beam flange (AISC 360-16 D3, J4.1)
The flange force is taken by half the beam’s area, less the two flange holes, with the shear lag factor U = 0.283 from Table D3.1 case 2:
[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.283 \left[ 0.5 \times 14.7 – 2 \times (1.1875) \times 0.57 \right] = 82.726\,kip [math]
DCR = 59.162 kip / 82.726 kip = 0.715 < 1.0, d'accord
Étape 9: Rupture par flexion de la poutre au niveau des trous de boulons de la bride (AISC 360-16 F13.1)
[math] A_{fg} = 7.5 \times 0.57 = 4.275\,in^{2}, \qquad A_{fn} = 4.275 – 2 \times (1.1875) \times 0.57 = 2.9213\,in^{2} [math]
With Fy / Fu = 0.76923, pas plus que 0.8, Yt = 1. ensuite:
[math] F_{u} A_{fn} = 189.88\,kip \lt Y_{t} F_{y} A_{fg} = 213.75\,kip [math]
so the holes reduce the flexural strength and Eq. F13-1 applies, with the beam’s elastic modulus of 89.005 en³:
[math] M_{n} = \frac{F_{ub} A_{fn}}{A_{fg}}\, S_{x} = \frac{65 \times 2.9213}{4.275} \times 89.005 = 329.44\,kip\text{-}ft [math]
[math] \phi R_{n} = \frac{0.9\, M_{n}}{d_{bm} – t_{fb}} = \frac{0.9 \times 329.44\,kip\text{-}ft}{18\,in – 0.57\,in} = 204.13\,kip [math]
DCR = 59.162 kip / 204.13 kip = 0.290 < 1.0, d'accord
Étape 10: Compression of the flange plate (AISC 360-16 J4.4)
KL/r of the plate is no more than 25, donc équation. J4-6 applies with no buckling reduction:
[math] \phi R_{n} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]
DCR = 59.162 kip / 219.38 kip = 0.270 < 1.0, d'accord
Étape 11: Detailing limit at the HSS face
| Limite de détail | Limite (in) | Réel (in) | DCR | Résultat |
|---|---|---|---|---|
| Taille maximale de soudure d'angle par dégagement de poutre | 0.500 | 0.500 | 1.000 | cdot K_a |
Le 1/2 in weld exactly fills the available clearance, ce qui est autorisé:
DCR = 1.000, d'accord
Étape 12: Fillet weld from the flange plate to the HSS face (AISC 360-16 K1, K5, J2.4)
This is where the HSS changes the design. The base metal limit first, from Manual Eq. 9-2:
[math] D_{max} = \frac{(0.375)(65) \le (0.465)(62)}{3.09} = 7.8883 [math]
Le 6.5 dans la plaque est plus large que le 4 in HSS face. The report allows that, but only the width over the face delivers load into it:
[math] B_{p,eff} = b_{fp} \le b = \min(6.5\,in, 4\,in) = 4\,in [math]
Eq. K1-1 then reduces it to the effective width:
[math] B_{e} = \left( \frac{10 t}{b} \right) \left( \frac{F_{ys}\, t}{F_{yp}\, t_{fp}} \right) B_{p,eff} \le B_{p,eff} = \left( \frac{10 \times 0.465}{4} \right) \left( \frac{50 \times 0.465}{50 \times 0.75} \right) \times 4 = 2.883\,in [math]
Per K5 the effective weld length is 2Be, and the report also caps Be at the workable flat:
[math] L_{w} = 2 \left( B_{e} \le W_{flat} \right) = 2 \times \min(2.883, 2.875) = 5.75\,in [math]
[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.5, \frac{7.8883}{16}\right) \times 5.75 = 63.144\,kip [math]
DCR = 59.162 kip / 63.144 kip = 0.937 < 1.0, d'accord
Étape 13: Local yielding of the flange plate on the HSS wall (AISC 360-16 K1, Guide de conception 24)
The same effective width idea limits the force the plate can deliver into the wall. The report uses φ = 0.95 from AISC Design Guide 24, Tableau 7-2:
[math] \phi R_{n} = \phi \left( \frac{10\, t^{2}\, F_{ys}\, B_{p,eff}}{b} \le F_{yp}\, t_{fp}\, B_{p,eff} \right) = 0.95 \times \min\left( \frac{10 \times 0.465^{2} \times 50 \times 4}{4},\; 50 \times 0.75 \times 4 \right) = 102.71\,kip [math]
DCR = 59.162 kip / 102.71 kip = 0.576 < 1.0, d'accord
Étape 14: Local yielding of the HSS sidewalls
The flange force also reaches the two sidewalls of the tube through the corners. The report checks them with the expression below and φ = 1.0, without citing a clause, so it is the software’s limit for this check:
[math] \phi R_{n} = \phi \times 2 F_{ys}\, t \left[ 5 (1.5 t) + t_{fp} \right] = 1.0 \times 2 \times 50 \times 0.465 \left[ 5 \times (1.5 \times 0.465) + 0.75 \right] = 197.04\,kip [math]
DCR = 59.162 kip / 197.04 kip = 0.300 < 1.0, d'accord
Shear plate section
The shear plate is a conventional single plate welded to the HSS face and carries the 19 réaction en kips. Its checks follow the shear tab procedure, worked in full in Comment concevoir une connexion par cisaillement à plaque unique, with the HSS face checks added.
Étape 15: Detailing limits of the shear plate at the beam (AISC 360-16 J3.3, J3.4)
| Limite de détail | Limite (in) | Réel (in) | DCR | Résultat |
|---|---|---|---|---|
| Espacement minimum des rangées de boulons | 2.667 | 3.000 | 0.889 | cdot K_a |
| Espacement maximal des rangées de boulons | 6.000 | 3.000 | 0.500 | cdot K_a |
| Distance minimale du bord vertical de la plaque | 1.250 | 1.500 | 0.833 | cdot K_a |
| Distance minimale du bord horizontal de la plaque | 1.375 | 1.500 | 0.917 | cdot K_a |
| Distance minimale du bord horizontal de la poutre | 1.250 | 1.500 | 0.833 | cdot K_a |
| Profondeur de connexion minimale | 7.750 | 9.000 | 0.861 | cdot K_a |
| Profondeur de connexion maximale | 16.000 | 9.000 | 0.563 | cdot K_a |
[math] DCR = \frac{1.375\,in}{1.5\,in} = 0.917 [math]
DCR = 0.917 < 1.0, d'accord
Étape 16: Shear plate bolt group (AISC 360-16 J3.6)
No fillers, donc [mathin] h_{f} = 1 [mathin] by J5.2(a). The report uses C = 3 for the three web bolts:
[math] \phi R_{n} = 0.75 \times 68 \times \frac{\pi}{4} (1\,in)^{2} \times (1) \times (3) \times (1) = 120.17\,kip [math]
DCR = 19 kip / 120.17 kip = 0.158 < 1.0, d'accord
Étape 17: Bearing and tear-out on the shear plate (AISC 360-16 J3.10)
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.375 \times 58 + \min(1.2 \times 1.875, 2.4) \times 0.375 \times 58 \times 2 \right] \times \frac{3}{3} = 91.758\,kip [math]
DCR = 19 kip / 91.758 kip = 0.207 < 1.0, d'accord
Étape 18: Bearing and tear-out on the beam web (AISC 360-16 J3.10)
[math] \phi R_{n} = (0.75) \times \min(1.2 \times 1.875, 2.4) \times (0.355\,in) \times (65\,ksi) \times (3) = 116.82\,kip [math]
DCR = 19 kip / 116.82 kip = 0.163 < 1.0, d'accord
Étape 19: Résistance effective du groupe de boulons d'âme (AISC 360-16 J3.6 Commentaire)
Par boulon: cisaillement 40.055 kip, plate edge bolt 18.352 kip, plate inner bolt 36.703 kip and beam web 38.939 kip. Boulons 1 et 2 take the inner-bolt value and bolt 3 the edge value:
[math] \Sigma \phi r_{eff} = 2 \times (36.703\,kip) + 18.352\,kip = 91.758\,kip, \qquad \phi R_{n,eff} = 91.758 \times \frac{3}{3} = 91.758\,kip [math]
DCR = 19 kip / 91.758 kip = 0.207 < 1.0, d'accord
Étape 20: Block shear of the shear plate (AISC 360-16 J4.3)
[math] A_{nt} = 0.30469\,in^{2}, \quad A_{gv} = 2.8125\,in^{2}, \quad A_{nv} = 1.6992\,in^{2} [math]
[math] \phi R_{n} = 0.75 \left( 0.6 \times 58 \times 1.6992 + 58 \times 0.30469 \le 0.6 \times 36 \times 2.8125 + 58 \times 0.30469 \right) = 57.604\,kip [math]
DCR = 19 kip / 57.604 kip = 0.330 < 1.0, d'accord
Étape 21: Shear yielding and rupture of the shear plate (AISC 360-16 J4.2)
[math] \phi R_{n\_sy} = 1.0 \times 0.6 \times 36 \times 3.375 = 72.9\,kip, \qquad \phi R_{n\_sr} = 0.75 \times 0.6 \times 58 \times 2.0391 = 53.22\,kip [math]
DCR = 19 kip / 53.22 kip = 0.357 < 1.0, d'accord
Étape 22: Detailing limits of the shear plate at the HSS wall
Les valeurs de planéité et d'élancement sont les limites du module pour une seule plaque sur un mur HSS..
| Limite de détail | Limite (in) | Réel (in) | DCR | Résultat |
|---|---|---|---|---|
| Taille maximale de soudure d'angle par dégagement de poutre | 0.500 | 0.188 | 0.376 | cdot K_a |
| Taille maximale de soudure d'angle par plat réalisable HSS | 0.885 | 0.188 | 0.212 | cdot K_a |
| Élancement maximal du mur HSS b/t | 33.716 | 5.602 | 0.166 | cdot K_a |
DCR = 0.376 < 1.0, d'accord
Étape 23: Weld from the shear plate to the HSS wall (AISC 360-16 J2.4)
[math] D_{max} = \frac{(0.1875)(58) \le (0.465)(62)}{3.09} = 3.5194, \qquad L_{w} = 2 \left[ 9 – 2 \times 0.1875 \right] = 17.25\,in [math]
[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.1875, \frac{3.5194}{16}\right) \times \left[ 1 + 0.5 \sin^{1.5}(0) \right] \times 17.25 = 72.042\,kip [math]
DCR = 19 kip / 72.042 kip = 0.264 < 1.0, d'accord
Étape 24: Poinçonnage mural HSS (Éq. manuel AISC. 10-7b, page 10-153)
[math] \phi R_{n} = \frac{0.75 \times 62 \times 0.465 \times 9^{2}}{5 \times 2} = 175.14\,kip [math]
DCR = 19 kip / 175.14 kip = 0.108 < 1.0, d'accord
Résumé des contrôles de conception
| Vérification de la conception | Demande | Capacité | DCR | Résultat |
|---|---|---|---|---|
| Bride: detailing at beam | 3.625 en jauge | 3.625 en minutes | 1.000 | cdot K_a |
| Flange bolts in slip | 59.162 kip | 62.701 kip | 0.944 | cdot K_a |
| Roulement sur plaque à bride | 59.162 kip | 230.34 kip | 0.257 | cdot K_a |
| Appui sur semelle de poutre | 59.162 kip | 187.57 kip | 0.315 | cdot K_a |
| Cisaillement de bloc, plaque de semelle | 59.162 kip | 168.19 kip | 0.352 | cdot K_a |
| Cisaillement de bloc, bride de poutre | 59.162 kip | 165.34 kip | 0.358 | cdot K_a |
| Tension de la plaque à bride | 59.162 kip | 141.68 kip | 0.418 | cdot K_a |
| Beam flange tension rupture | 59.162 kip | 82.726 kip | 0.715 | cdot K_a |
| Beam flexural rupture at holes | 59.162 kip | 204.13 kip | 0.290 | cdot K_a |
| Compression de la plaque à bride | 59.162 kip | 219.38 kip | 0.270 | cdot K_a |
| Bride: detailing at HSS face | 0.5 en soudure | 0.5 en maximum | 1.000 | cdot K_a |
| Flange plate weld to HSS | 59.162 kip | 63.144 kip | 0.937 | cdot K_a |
| Flange plate local yielding | 59.162 kip | 102.71 kip | 0.576 | cdot K_a |
| HSS sidewall local yielding | 59.162 kip | 197.04 kip | 0.300 | cdot K_a |
| Shear plate: detailing at beam | 1.375 en minutes | 1.5 in edge | 0.917 | cdot K_a |
| Shear plate bolt group | 19 kip | 120.17 kip | 0.158 | cdot K_a |
| Bearing on shear plate | 19 kip | 91.758 kip | 0.207 | cdot K_a |
| Appui sur l'âme de la poutre | 19 kip | 116.82 kip | 0.163 | cdot K_a |
| Effective web bolt group strength | 19 kip | 91.758 kip | 0.207 | cdot K_a |
| Cisaillement de bloc, shear plate | 19 kip | 57.604 kip | 0.330 | cdot K_a |
| Cédante au cisaillement et rupture, shear plate | 19 kip | 53.22 kip | 0.357 | cdot K_a |
| Shear plate: detailing at HSS wall | 0.188 en soudure | 0.5 en maximum | 0.376 | cdot K_a |
| Shear plate weld to HSS | 19 kip | 72.042 kip | 0.264 | cdot K_a |
| Poinçonnage mural HSS | 19 kip | 175.14 kip | 0.108 | cdot K_a |
La connexion passe tous les contrôles. The two ratios at 1.000 are detailing limits that the layout meets exactly. Des contrôles de force, the flange bolts in slip govern at 0.944, followed closely by the flange plate weld to the HSS face at 0.937. The weld is limited by the HSS: uniquement 2.883 dans du 6.5 in plate counts as effective width, and the weld length is capped at the 2.875 in workable flat of the 4 in face.
Que changer si une vérification échoue
- Flange bolts in slip: add bolts along the beam, utiliser un boulon plus gros, or a Class B faying surface. A deeper beam lowers the flange force for the same moment.
- Flange plate weld to the HSS: a thicker HSS wall raises Be, since Be grows with the square of the wall thickness, and a wider tube face gives a longer workable flat. A thicker flange plate lowers Be, so do not thicken the plate to fix this check.
- Flange plate local yielding or HSS sidewall yielding: use a thicker-walled tube.
- Beam flange tension rupture or flexural rupture: reduce the holes in the flange or use a heavier beam.
- Block shear or plate tension: increase the edge distances, the bolt spacing or the plate thickness.
- Shear plate checks: as for a shear tab, add a bolt row or make the plate deeper.
Auto Design is available for the flange plate moment connection to an HSS column. Ça change les boulons, plates and welds until every check passes, et conserve vos membres et vos charges tels qu'ils ont été saisis. Voir le Conception automatique page pour les préférences sur lesquelles il fonctionne.
Questions fréquentes
How is this different from a flange plate connection to a W-shape column?
The beam side checks, Étapes 1 à 10, are the same as in Comment concevoir une connexion par moment avec plaque à bride. The difference is at the column. On a W-shape column the plates weld to a thick flange backed by the column web. An HSS face is a thin wall between the corners, so the flange plate is reduced to an effective width for the weld and for plate local yielding, and the tube sidewalls are checked for local yielding.
Pourquoi le 6.5 in flange plate wider than the 4 in HSS face?
The plate is sized to bolt to the 7.5 in beam flange at a 3.625 en jauge, which needs more width than the tube face has. The report allows a plate wider than the face, but only the 4 in over the face counts when the force goes into the HSS.
What is the effective width Be?
Eq. K1-1 reduces a plate welded across an HSS face to the width that is effective in carrying load into the wall. It depends on the wall slenderness b/t and on the ratio of wall to plate strength and thickness. Here Be = 2.883 dans du 4 in effective plate width.
Why is the flange force 59.162 kip?
Le 38 kip-ft moment is divided by the distance between flange centers, 17.43 in, donner 26.162 kip, and half of the 66 kip axial force is added to each flange. The report uses this one flange force for every check in the flange plate section.
Does this example follow the AISC 15th or 16th edition Manual?
Il suit l'AISC 360-16 with the AISC Manual 15th Edition and AISC Design Guide 24 for the HSS plate local yielding factor. Clause and page references move in the 16th Edition Manual and AISC 360-22, alors vérifiez-les par rapport à l'édition utilisée par votre projet.
Design a flange plate moment connection to an HSS column for free
Chaque numéro sur cette page provient d'une seule solution. Pick the flange plate moment connection to an HSS column, entrez votre faisceau, tube, plaques, boulons et charges, et voyez chacune de ces vérifications dans votre navigateur. Il n'y a rien à installer.
Le module SkyCiv Connection Design est le logiciel de conception de connexion derrière cet exemple. Il vous donne le rapport de calcul complet avec chaque équation et vos chiffres, comme les étapes ci-dessus, plus toutes les capacités et DCR, selon AISC 360-22 et AISC 360-16 (LRFD et TSA) et AS 4100:2020. Le calculateur de boulons et calculateur de soudure couvrir le groupe de boulons et les contrôles de soudure seuls.
Références
- AISC 360-16, Spécification pour les bâtiments en acier de construction: D3 (Tableau D3.1), F13.1 (Eq. F13-1), J2.4 (Eq. J2-4), J3.3, J3.4 (Tableau J3.4), J3.6 (Eq. J3-1) et commentaire, J3.8 (Eq. J3-4), J3.10 (Eq. J3-6a, J3-6c), J4.1 (Eq. J4-1, J4-2), J4.2 (Eq. J4-3, J4-4), J4.3 (Eq. J4-5), J4.4 (Eq. J4-6), J5.2(a), K1 (Eq. K1-1, K1-2), K5.
- Manuel de construction en acier AISC, 15e édition: Partie 9, Eq. 9-2; Partie 10, Eq. 10-7b (page 10-153).
- Guide de conception AISC 24, Hollow Structural Section Connections: Tableau 7-2.