Documentation SkyCiv

Votre guide du logiciel SkyCiv — tutoriels, guides pratiques et articles techniques

Cisaillement d'âme directement soudé et conception de connexion axiale

When a directly welded web connection carries an axial force as well as the end shear, two things change in the design to AISC 360. The welds now see a resultant force at an angle to their axis, which is larger than the shear alone but also earns the directional strength increase of Eq. J2-5. And the axial force is delivered to the column flange as a concentrated force, so the column has to be checked for flange local bending, web local yielding and, en compression, web local crippling.

This page works the same connection as the shear-only directly welded web example, a W18x50 beam web welded to the flange of a W14x90 column with 3/16 dans les soudures d'angle E70XX 15.5 in long on both sides of the web, and adds an axial force of 132 kip in tension or compression to the 38 kip end shear (LRFD). La conception est conforme à l'AISC 360-16 et le manuel AISC 15e édition. Chaque équation est écrite avec ses chiffres, dans le même ordre que la feuille de calcul que le SkyCiv Connection Design le module produit pour cette connexion.

What the axial force adds to a directly welded web connection

A beam in a braced frame or a diaphragm chord often carries an axial force along with its end reaction, for example as a strut or collector. With a directly welded web, that force has no plate or bolts to pass through: it goes straight from the web into the two fillet welds and from them into the column flange.

The member sizes, weld and the checks of the minimum weld size and the beam web in shear are the same as in the shear-only example, and give the same results. This page focuses on the weld under combined load and on the two support checks the axial force adds. The other shear connection types are on the connexions de cisaillement page.

Élévation d'âme directement soudée: W18x50 web welded to a W14x90 flange, 3/16 in E70XX fillets, Vu = 38 kip, Vous = Avec = kip kip

Élévation de l'exemple de connexion, avec le 38 cisaillement et le 132 kip tension or compression at the beam end.

Onglet Assemblage de conception de connexion SkyCiv: Directly Welded Web config for shear plus axial, Poutre W18x50 sur bride de colonne W14x90

La même connexion dans SkyCiv Connection Design, avec la configuration Web directement soudée dans l'onglet Assemblage.

Directly welded web shear and axial design: les étapes en un coup d'œil

  1. Vérifiez la taille minimale de la soudure d'angle.
  2. Check the welds for the resultant of the shear and the axial force.
  3. Vérifier l'âme de la poutre en cisaillement.
  4. Check the column for the axial tension: flange local bending and web local yielding.
  5. Check the column for the axial compression: web local crippling and web local yielding.

Entrées de conception pour cet exemple

Le code de conception est AISC 360-16 LRFD. Les propriétés de la section proviennent du manuel AISC. Les kdes de la colonne, utilisé dans le rendement Web local, est 1.31 in.

ArticleSymboleValeur
Cisaillement pondéré[mathin] V_{u} [mathin]38 kip
Tension axiale pondérée[mathin] T_{u} [mathin]132 kip
Compression axiale pondérée[mathin] C_{u} [mathin]132 kip
BeamL18x50, A992
Profondeur du faisceau / épaisseur de l'âme[mathin] d_{bm},\ t_{wb} [mathin]18 in / 0.355 in
PoteauL14x90, A992
Profondeur de colonne / épaisseur de l'âme[mathin] d_{sup},\ t_{ws} [mathin]14 in / 0.44 in
Largeur de l'aile du poteau / thickness[mathin] b_{fs},\ t_{fs} [mathin]14.5 in / 0.71 in
Kdes de colonne[mathin] k_{des} [mathin]1.31 in
Rendement des poutres et des poteaux / contrainte de traction[mathin] F_{y},\ F_{u} [mathin]50 ksi / 65 ksi
Module d'élasticité[mathin] E [mathin]29000 ksi
SouderFilet E70XX, les deux côtés du Web
Taille de soudure / length on each side[mathin] W,\ L_{wv} [mathin]0.1875 in / 15.5 in

Étape 1: Taille minimale de la soudure d'angle (AISC 360-16 J2.2b, Tableau J2.4)

The axial force does not change this check. The thinner part joined is the 0.355 dans l'âme de la poutre, so the Table J2.4 minimum is 3/16 in, and the weld is 3/16 in.

DCR = 0.1875 in / 0.1875 dans = 1.000 ≤ 1.0, d'accord

Étape 2: Welds under the resultant of shear and axial force (AISC 360-16 J2.4)

The base metal limit and the effective length are the same as for shear alone, half the web thickness against the column flange, and twice the weld size off each end:

[math] D_{max} = \frac{\min\left( t_{fs} F_{us},\ \frac{t_{wb}}{2} F_{ub} \right)}{3.09\ \text{kip/in}} = \frac{\min\left( (0.71\ \text{in})(65\ \text{ksi}),\ (0.1775\ \text{in})(65\ \text{ksi}) \right)}{3.09\ \text{kip/in}} = 3.7338 [math]

[math] L_{w} = 2\left[ L_{wv} – 2W \right] = 2 \times \left[ 15.5\ \text{in} – 2 \times 0.1875\ \text{in} \right] = 30.25\ \text{in} [math]

What changes is the load. The welds now carry the vertical shear along their axis and the axial force across it. The demand is the resultant of the two, at an angle to the weld axis:

[math] R_{u} = \sqrt{V_{u}^{2} + T_{u}^{2}} = \sqrt{(38\ \text{kip})^{2} + (132\ \text{kip})^{2}} = 137.36\ \text{kip} [math]

[math] \theta_{u} = \tan^{-1}\left( \frac{T_{u}}{V_{u}} \right) = \tan^{-1}\left( \frac{132}{38} \right) = 73.94^{\circ} [math]

A fillet weld loaded across its axis is stronger than one loaded along it, et l'Éq. J2-5 rewards that with the directional term:

[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left( W,\ \frac{D_{max}}{16} \right) \left[ 1 + 0.5 \left( \sin\theta_{u} \right)^{1.5} \right] L_{w} [math]

[math] \phi R_{n} = (0.75) \times 0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left( 0.1875\ \text{in},\ \frac{3.7338}{16} \right) \times \left[ 1 + 0.5 \left( \sin 73.94^{\circ} \right)^{1.5} \right] \times (30.25\ \text{in}) = 185.84\ \text{kip} [math]

DCR = 137.36 kip / 185.84 kip = 0.739 < 1.0, d'accord

C'est le chèque déterminant. The same welds are good for 126.33 kip under shear alone, so the load angle adds about 47% to their strength. The demand grows faster, cependant, de 38 kip to 137.36 kip, and the ratio rises from 0.301 à 0.739. The tension and compression cases have the same resultant, so one weld check covers both.

Étape 3: Âme de poutre en cisaillement (AISC 360-16 J4.2)

The beam web still carries only the 38 kips d'effort tranchant, over its full depth:

[math] \phi R_{n} = \phi\, 0.6\, F_{yb}\, d_{bm}\, t_{wb} = (1) \times 0.6 \times (50\ \text{ksi}) \times (18\ \text{in})(0.355\ \text{in}) = 191.7\ \text{kip} [math]

DCR = 38 kip / 191.7 kip = 0.198 < 1.0, d'accord

Étape 4: Colonne sous tension axiale (AISC 360-16 J10.1, J10.2)

The axial tension pulls on the column flange along the line of the weld. AISC 360-16 J10 covers this as a concentrated force on the flange: flexion locale de la bride (J10.1), where it applies, et rendement web local (J10.2). Web local paralysant (J10.3) is for compressive forces only.

Flexion locale de la semelle

J10.1 does not require a flange local bending check when the length of loading measured across the member flange is less than 0.15 times the flange width:

[math] 0.15\, b_{f} = 0.15\, b_{fs} = 0.15 \times (14.5\ \text{in}) = 2.175\ \text{in} [math]

The load is delivered by the beam web, so the loaded length across the column flange is the web thickness, [mathin] t_{wb} = 0.355\ \text{in} [mathin]. That is less than 2.175 in, so flange local bending need not be checked.

Plastification locale de l'âme

The force spreads through the column flange into the web over the weld length plus [mathin] 5k [mathin] (Eq. J10-2):

[math] \phi R_{n} = \phi\, F_{ys}\, t_{ws} \left( 5 k_{des} + L_{wv} \right) = (1) \times (50\ \text{ksi}) \times (0.44\ \text{in}) \times \left( 5 \times 1.31\ \text{in} + 15.5\ \text{in} \right) = 485.1\ \text{kip} [math]

DCR = 132 kip / 485.1 kip = 0.272 < 1.0, d'accord

Étape 5: Colonne sous compression axiale (AISC 360-16 J10.2, J10.3)

In compression the beam pushes on the column flange, so web local crippling joins web local yielding. Web local paralysant, Eq. J10-4, with the weld length as the bearing length:

[math] \phi R_{n,wlc} = \phi\, 0.8\, t_{ws}^{2} \left[ 1 + 3\left( \frac{L_{wv}}{d_{sup}} \right) \left( \frac{t_{ws}}{t_{fs}} \right)^{1.5} \right] \sqrt{\frac{E F_{ys} t_{fs}}{t_{ws}}}\, Q_{f} [math]

[math] \phi R_{n,wlc} = (0.75) \times 0.8 \times (0.44\ \text{in})^{2} \left[ 1 + 3\left( \frac{15.5}{14} \right) \left( \frac{0.44}{0.71} \right)^{1.5} \right] \sqrt{\frac{(29000\ \text{ksi})(50\ \text{ksi})(0.71\ \text{in})}{0.44\ \text{in}}} \times (1) = 465.59\ \text{kip} [math]

Web local yielding is the same as in tension, 485.1 kip. The lower of the two governs:

[math] \phi R_{n} = \min\left( 465.59\ \text{kip},\ 485.1\ \text{kip} \right) = 465.59\ \text{kip} [math]

DCR = 132 kip / 465.59 kip = 0.284 < 1.0, d'accord

Both column checks pass with room to spare, so this W14x90 needs no stiffeners or web doubler for these limit states.

Récapitulatif des contrôles

Vérification de la conceptionDemandeCapacitéDCRRésultat
Taille minimale de la soudure d'angle0.1875 in0.1875 in1.000cdot K_a
Welds under shear and axial force137.36 kip185.84 kip0.739cdot K_a
Âme de poutre en cisaillement38 kip191.7 kip0.198cdot K_a
Colonne sous tension axiale132 kip485.1 kip0.272cdot K_a
Colonne sous compression axiale132 kip465.59 kip0.284cdot K_a

Every check in this directly welded web shear and axial connection design passes. Le 1.000 le rapport est la taille minimale de la soudure d'angle, Les contrôles de longueur de développement et de stabilité sont des paramètres importants qui doivent satisfaire le résultat sans dépasser une valeur de 3/16 dans la soudure correspond exactement. Des contrôles de force, les soudures gouvernent à 0.739 sous le 137.36 kip resultant, contre 0.301 for the same welds under shear alone. The column checks for the axial force come next, with web local crippling in compression at 0.284.

Auto Design is available for the directly welded web connection with shear and axial load to a column flange. Il modifie les variables de conception de la connexion jusqu'à ce que chaque vérification soit réussie, et conserve vos membres et vos charges tels qu'ils ont été saisis. Voir le Conception automatique page pour les préférences sur lesquelles il fonctionne.

Que changer si une vérification échoue

  • Force de soudure: lengthen the welds, increase the weld size up to the base metal limit of the half web, ou utilisez une électrode plus puissante. Past that limit a larger weld adds no strength.
  • Column web local yielding or crippling: a longer weld spreads the force over more of the column web and raises both strengths. Otherwise use a column with a thicker web, or add stiffeners or a web doubler.
  • Flexion locale de la semelle: with a directly welded web it only applies if the loaded length across the flange reaches 0.15 times the flange width.
  • Minimum weld size or beam web shear: as for shear alone, meet the Table J2.4 minimum, ou utilisez une poutre plus lourde.

Questions fréquentes

Why does the weld get stronger when the axial force is added?

The strength of a fillet weld depends on the direction of the load. Under pure shear the load runs along the weld, and the directional term of Eq. J2-5 est 1. Avec 132 kip of axial force the resultant turns to 73.94 degrees from the weld axis, and the term rises toward its maximum of 1.5 for a load at 90 degrés. Here it lifts the weld strength from 126.33 kip to 185.84 kip.

Why is only one weld check reported for both tension and compression?

The axial force is 132 kip de toute façon, so the resultant on the welds is the same 137.36 kip at the same angle. The sign of the axial force matters for the column, which is why the support is checked separately for tension and compression.

Why is flange local bending not checked?

J10.1 only requires it when the force is spread across a meaningful width of the column flange. Here the force comes in through a 0.355 dans l'âme de la poutre, which is much less than 0.15 fois le 14.5 en largeur de bride, 2.175 in, so J10.1 does not require the check.

Why is web local crippling checked only in compression?

Web local crippling is the buckling of the column web under a compressive force pushed through the flange. A tensile force pulls the web straight, so J10.3 applies to compressive forces only, while web local yielding applies to both.

Comment cela changerait-il pour AISC ASD au lieu de LRFD?

Les états limites et les résistances nominales sont les mêmes. Avec AISC ASD, vous comparez les forces de niveau de service à la résistance nominale divisée par un facteur de sécurité.: 0.75 for the welds and for web local crippling becomes a safety factor of 2.00, et 1.00 for web shear yielding and web local yielding becomes 1.50.

Concevez gratuitement une connexion web directement soudée

Chaque numéro sur cette page provient d'une seule solution. Pick the directly welded web configuration with shear and axial load, entrez votre faisceau, soutien, weld and forces, et la calculatrice gratuite exécute chacune de ces vérifications dans votre navigateur sans rien installer.

Le module SkyCiv Connection Design est le logiciel de conception de connexion derrière cet exemple. Il vous donne le rapport de calcul complet avec chaque équation et vos chiffres, comme les étapes ci-dessus, plus toutes les capacités et DCR, selon AISC 360-22 et AISC 360-16 (LRFD et TSA) et AS 4100:2020. Le calculateur de soudure couvre les groupes de soudures d'angle à eux seuls.

Références

  • AISC 360-16, Spécification pour les bâtiments en acier de construction: J2.2b (Tableau J2.4), J2.4 (Eq. J2-4, J2-5), J4.2 (Eq. J4-3), J10.1, J10.2 (Eq. J10-2), J10.3 (Eq. J10-4).
  • Manuel de construction en acier AISC, 15e édition: Partie 9 (Eq. 9-2), Partie 10 (longueur de soudure efficace).
  • Conception d'assemblages en acier utilisant AISC 360-16
  • Conception automatique dans la conception de connexion SkyCiv
Harold Munalem, Chef de produit pour SkyCiv Connection Design

Harold Munalem
Chef de produit, Connection Design
10+ années dans la conception d'assemblages en acier
LinkedIn

Comment pouvons-nous vous aider?

×

Aller en haut