SkyCiv Documentation

Your guide to SkyCiv software — tutorials, how-to guides and technical articles

Web Side Plate Connection Design to AS 4100

To design a web side plate connection to AS 4100, you check every part of the load path from the beam web to the support: the bolts in shear and in bearing, the plate in shear, bending and block shear, the fillet welds to the support, and the beam web in shear. The detailing limits on pitch, edge distance, plate depth and clearance come first, because the capacity equations assume a connection that can be built and that rotates as a simple connection.

This page works through one example from start to finish: a 460 UB 82.1 beam framing into the flange of a 310 UC 158 column, with a design shear of 150 kN, eight M20 8.8/S bolts and a 10 mm Grade 250 plate, designed to AS 4100:2020. Every equation is written out with its numbers, in the same order as the calculation report that the SkyCiv Connection Design module produces for it. The scope and conventions of the AS 4100 module are on the design of steel connections using AS 4100:2020 page.

What is a web side plate connection?

A web side plate connection is a flat plate fillet welded to the supporting member in the shop and bolted to the web of the supported beam on site. It carries the beam end shear and is detailed as a simple connection: the thin plate and the bolts let the beam end rotate, so the joint takes almost no end moment. It is also called a fin plate or a shear tab.

It is one of the most common shear connections in Australian building frames. The beam can be lowered into place between the columns without spreading them, and the only site work is bolting. The other shear connections in the AS 4100 module do the same job with a different load path: the flexible end plate is welded to the beam and bolted to the support, and the single and double angles are bolted on both sides. You can check this one directly in the web side plate calculator.

In this example the plate is welded to the flange of the column and has two vertical lines of four bolts, so the bolt group is eight bolts on a 75 mm grid.

Web side plate elevation: 460 UB 82.1 beam bolted with eight M20 8.8/S bolts to a plate welded to a 310 UC 158 flange

Elevation of the example connection. The beam stops 20 mm short of the column flange, and the first bolt column is 70 mm from the face of the support.

Section A-A through the beam web: PL 10x200x320 Gr.250 web side plate with 8 mm E49XX fillet welds both sides

Section A-A. The 10 mm plate sits on one side of the beam web, with an 8 mm E49XX fillet weld on both sides of the plate at the column.

SkyCiv Connection Design Assembly tab: web side plate 200 x 320 x 10 mm, AS/NZS 3678 Gr.250, shown in the 3D view

The same connection in SkyCiv Connection Design, with the plate selected on the Assembly tab.

Web side plate connection design: the steps at a glance

  1. Check the connection detailing limits: pitch, edge distances, plate depth and clearance.
  2. Check the minimum fillet weld size.
  3. Check the design capacity of the weld to the supporting member.
  4. Check the design capacity of the bolt group in shear, by the instantaneous centre of rotation.
  5. Check the bolt group in bearing on the plate and on the beam web.
  6. Check the web side plate in shear.
  7. Check the web side plate in bending.
  8. Check the web side plate in block shear.
  9. Check the supported member (beam web) in shear.

Design inputs for this example

The design code is AS 4100:2020, with section properties from the Australian section database. The yield strength of each part follows its grade and thickness: the 16 mm beam flange gives 300 MPa for the beam, the 25 mm column flange gives 280 MPa for the column, and the 10 mm Grade 250 plate gives 260 MPa.

ItemSymbolValue
Design shear (design action effect)[mathin] V^{*} [mathin]150 kN
Beam460 UB 82.1, AS/NZS 3679.1 Gr.300
Beam depth[mathin] d_{bm} [mathin]460 mm
Beam web thickness[mathin] t_{wb} [mathin]9.9 mm
Beam flange width / thickness[mathin] b_{fb},\ t_{fb} [mathin]191 mm / 16 mm
Beam yield / tensile strength[mathin] f_{yb},\ f_{ub} [mathin]300 MPa / 440 MPa
Column310 UC 158, AS/NZS 3679.1 Gr.300
Column depth / web thickness[mathin] d_{sup},\ t_{ws} [mathin]327 mm / 15.7 mm
Column flange width / thickness[mathin] b_{fs},\ t_{fs} [mathin]311 mm / 25 mm
Column yield / tensile strength[mathin] f_{ys},\ f_{us} [mathin]280 MPa / 440 MPa
Elastic modulus[mathin] E [mathin]200000 MPa
ItemSymbolValue
Web side platePL 10 x 200 x 320, AS/NZS 3678 Gr.250
Plate width / depth / thickness[mathin] b_{i},\ d_{i},\ t_{i} [mathin]200 mm / 320 mm / 10 mm
Plate yield / tensile strength[mathin] f_{yp},\ f_{up} [mathin]260 MPa / 410 MPa
BoltsM20 8.8/S, threads included in the shear plane
Bolt diameter / minimum tensile strength[mathin] d_{f},\ f_{uf} [mathin]20 mm / 830 MPa
Holes in beam web and plate[mathin] d_{h} [mathin]Nominal, 22 mm
Weld to column flange8 mm fillet both sides, E49XX, SP
Weld size / weld metal strength[mathin] t_{ww},\ f_{uw} [mathin]8 mm / 490 MPa
GeometrySymbolValue
Bolt rows / row pitch[mathin] n_{p},\ s_{p} [mathin]4 / 75 mm
Bolt columns / column pitch[mathin] n_{g},\ s_{g} [mathin]2 / 75 mm
Beam end clearance to column flange[mathin] clr [mathin]20 mm
Support face to first bolt column[mathin] l [mathin]70 mm
Horizontal edge distance on beam web[mathin] l_{eh\_w} [mathin]50 mm
Vertical edge distance on plate[mathin] l_{ev\_wp} [mathin]47.5 mm
Horizontal edge distance on plate[mathin] l_{eh\_wp} [mathin]55 mm
Bolt group eccentricity[mathin] e_{b} [mathin]107.5 mm
Weld group eccentricity[mathin] e_{w} [mathin]0 mm

The bolt group eccentricity is the distance from the face of the support to the centroid of the bolt group, 70 mm to the first bolt column plus half the 75 mm column pitch. The support is treated as flexible, so the weld group takes the shear with no eccentricity.

Design shear (AS 4100 Clause 9.1.4)

AS 4100 Clause 9.1.4 sets a minimum design action for a simple connection. The design shear is not taken less than the lesser of 0.15 times the design shear capacity of the beam and 40 kN. The beam capacity is the uncoped web shear capacity, which Step 9 uses again:

[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (460\ \text{mm}) \times (9.9\ \text{mm}) = 737.75\ \text{kN} [math]

[math] V^{*}_{min} = \min\left( 0.15\, \phi V_{vo},\ 40\ \text{kN} \right) = \min\left( 0.15 \times (737.75\ \text{kN}),\ 40\ \text{kN} \right) = 40\ \text{kN} [math]

[math] V^{*} = \max\left( V^{*},\ V^{*}_{min} \right) = \max\left( 150\ \text{kN},\ 40\ \text{kN} \right) = 150\ \text{kN} [math]

The 150 kN entered is well above the minimum, so it is the design action effect for every check below.

Step 1: Connection detailing limitations (AS 4100 Clause 9.5)

Before any capacity check, the bolt layout has to be buildable and match the assumptions behind the capacity equations. Bolts too close together tear between the holes, edges too close tear out, and a plate that is too shallow or too deep changes how the connection rotates and whether it fits between the beam root radii.

The minimum pitch is [mathin] 2.5\, d_{f} = 2.5 \times 20\ \text{mm} = 50\ \text{mm} [mathin] (Clause 9.5.1). The minimum edge distance for an M20 bolt is 35 mm, [mathin] 1.75\, d_{f} [mathin] from Table 9.5.2. The maximum edge distance is 12 times the thinner ply, [mathin] 12 \times 9.9\ \text{mm} = 118.8\ \text{mm} [mathin], and the maximum column pitch is 15 times the thinner ply, [mathin] 15 \times 9.9\ \text{mm} = 148.5\ \text{mm} [mathin]. The plate must also be no deeper than the flat of the beam web, [mathin] 405.2\ \text{mm} [mathin], and the beam end must clear the column flange by at least 20 mm.

Detailing limitLimit (mm)Actual (mm)DCRResult
Minimum bolt row pitch on plate50.00075.0000.667PASS
Maximum bolt row pitch on plate139.60075.0000.537PASS
Minimum bolt column pitch on plate50.00075.0000.667PASS
Maximum bolt column pitch on plate148.50075.0000.505PASS
Minimum vertical edge distance on plate35.00047.5000.737PASS
Minimum horizontal edge distance on plate35.00055.0000.636PASS
Minimum horizontal edge distance on beam web35.00050.0000.700PASS
Minimum plate depth230.000320.0000.719PASS
Maximum plate depth405.200320.0000.790PASS
Minimum clearance20.00020.0001.000PASS
Maximum edge distance118.80055.0000.463PASS

For a minimum limit the ratio is limit over actual, and for a maximum it is actual over limit. The governing row is the clearance between the beam end and the column flange:

[math] DCR = \frac{20\ \text{mm}}{20\ \text{mm}} = 1.000 [math]

DCR = 1.000 ≤ 1.0, OK

A ratio of exactly 1.000 is normal here. The 20 mm gap was set at the minimum, so the check sits on its limit without being a strength problem.

Step 2: Minimum fillet weld size (AS 4100 Table 9.6.3.2)

A fillet weld that is too small for the parts it joins cools too fast and can crack, so AS 4100 Table 9.6.3.2 sets a minimum size based on the thicker part, here the 25 mm column flange. That minimum is 6 mm, and it may not exceed the thinner part, the 10 mm plate.

The weld is also sized to develop the plate, so that if the plate yields in bending or shear the weld is not the weak link. The program takes this as three quarters of the plate thickness:

[math] t_{w,pl} = 0.75\, t_{i} = 0.75 \times (10\ \text{mm}) = 7.5\ \text{mm} [math]

[math] t_{w,req} = \max\left( t_{w,pl},\ t_{w,min} \right) = \max\left( 7.5\ \text{mm},\ 6\ \text{mm} \right) = 7.5\ \text{mm} [math]

[math] t_{ww} = 8\ \text{mm} \ge t_{w,req} = 7.5\ \text{mm} [math]

DCR = 7.5 mm / 8 mm = 0.938 ≤ 1.0, OK

This ratio compares weld sizes, not a design action with a capacity. It is high because 8 mm is the next practical size above 7.5 mm.

Step 3: Design capacity of the weld to the supporting member (AS 4100 Clause 9.6.3.10)

The two fillet welds join the plate to the column flange and carry the whole design shear. The weld is Structural Purpose (SP), so the capacity factor is 0.8 from Table 3.4. The design capacity per unit length of an equal-leg fillet weld, with a throat of the leg size over the square root of 2:

[math] \phi v_{w} = \phi\, 0.6\, f_{uw}\, \frac{\sqrt{2}}{2}\, t_{ww}\, k_{r} [math]

[math] \phi v_{w} = (0.8) \times 0.6 \times (490\ \text{MPa}) \times \frac{\sqrt{2}}{2} \times (8\ \text{mm}) \times (1) = 1.3305\ \text{kN/mm} [math]

Here [mathin] k_{r} = 1 [mathin] because the weld is not a long welded lap joint. The weld runs the full plate depth on both sides of the plate, [mathin] l_{w} = d_{i} = 320\ \text{mm} [mathin], and the support is flexible, so there is no eccentricity on the weld group:

[math] \phi V_{w} = 2\, l_{w}\, \phi v_{w} = 2 \times (320\ \text{mm}) \times (1.3305\ \text{kN/mm}) = 851.51\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{w} = 851.51\ \text{kN} [math]

DCR = 150 kN / 851.51 kN = 0.176 ≤ 1.0, OK

Step 4: Design capacity of the bolt group in shear (AS 4100 Clauses 9.2.2.1, 9.3.1)

The design shear acts at the face of the support, 107.5 mm from the centroid of the bolts, so the bolt group carries a moment as well as the shear. The bolts nearest the corners take the most force. Clause 9.3.1 allows the bolt forces to be found by an analysis of the group, and the module uses the instantaneous centre of rotation (ICOR) method, which turns the eccentric group into a bolt group coefficient C.

Design shear capacity of one bolt

The threads are in the single shear plane, so the core area is used: [mathin] n_{n} = 1,\ A_{c} = 225\ \text{mm}^{2} [mathin] and [mathin] n_{x} = 0 [mathin]. The capacity factor for a bolt in shear is 0.8:

[math] \phi V_{f} = \phi\, 0.62\, f_{uf}\, k_{rd}\, k_{r}\, \left( n_{n} A_{c} + n_{x} A_{o} \right) [math]

[math] \phi V_{f} = (0.8) \times 0.62 \times (830\ \text{MPa}) \times (1) \times (1) \times \left( (1)(225\ \text{mm}^{2}) + (0)(314.16\ \text{mm}^{2}) \right) = 92.628\ \text{kN} [math]

The reduction factors are both 1: [mathin] k_{rd} [mathin] for ductility, and [mathin] k_{r} [mathin] because the joint is not a long bolted lap joint.

Locating the instantaneous centre

Bolt 1 is at the bottom left of the group. The instantaneous centre is found by iteration, as described on the AS 4100 module page.

Boltx (mm)y (mm)
10.000.00
20.0075.00
30.00150.00
40.00225.00
575.000.00
675.0075.00
775.00150.00
875.00225.00

The iteration converges with the instantaneous centre, measured from bolt 1, at:

[math] x_{ic} = -30.727\ \text{mm}, \qquad y_{ic} = 112.5\ \text{mm} [math]

The bolt reactions at that point are:

BoltR (kN)Rx (kN)Ry (kN)Mn (kN-mm)
188.6585.5223.3610338.69
273.4756.8346.573562.07
373.47-56.8346.573562.07
488.65-85.5223.3610338.69
590.9166.2562.2614035.81
688.2429.5083.169898.73
788.24-29.5083.169898.73
890.91-66.2562.2614035.81

Bolt group capacity

The vertical reactions add up to the capacity of the group. The horizontal reactions cancel, so [mathin] \sum R_{x} [mathin] is zero to rounding:

[math] \phi V_{df} = \sqrt{ \left( \sum R_{x} \right)^{2} + \left( \sum R_{y} \right)^{2} } = \sqrt{ (0\ \text{kN})^{2} + (430.69\ \text{kN})^{2} } = 430.69\ \text{kN} [math]

[math] C = \frac{\phi V_{df}}{\phi V_{f}} = \frac{430.69\ \text{kN}}{92.628\ \text{kN}} = 4.6497 [math]

C = 4.65 for eight bolts means the 107.5 mm eccentricity costs the group a little over 40% of its concentric capacity. The same coefficient scales the bearing capacity in Step 5.

[math] V^{*} = 150\ \text{kN} \le \phi V_{df} = 430.69\ \text{kN} [math]

DCR = 150 kN / 430.69 kN = 0.348 ≤ 1.0, OK

Step 5: Bolt group in bearing on the plate and the beam web (AS 4100 Clause 9.2.2.4)

Each bolt bears on the side of its hole in the plate and in the beam web. A ply can fail by crushing at the hole, capped at [mathin] 3.2\, d_{f}\, t_{p}\, f_{up} [mathin], or by tearing out to an edge or to the next hole, which depends on [mathin] a_{e} [mathin]. Under ICOR the bolt forces act in different directions, so the least distance in any direction governs each ply.

Bearing on the web side plate

[mathin] a_{e} [mathin] is the distance from the edge of the hole to the edge of the ply, or to the next hole, plus half the bolt diameter. With [mathin] d_{h} = 22\ \text{mm} [mathin]:

[math] a_{e1} = l_{ev\_wp} – 0.5\, d_{h} + 0.5\, d_{f} = (47.5\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 46.5\ \text{mm} [math]

[math] a_{e2} = s_{p} – d_{h} + 0.5\, d_{f} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

[math] a_{e3} = l_{eh\_wp} – 0.5\, d_{h} + 0.5\, d_{f} = (55\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 54\ \text{mm} [math]

[math] a_{e4} = s_{g} – d_{h} + 0.5\, d_{f} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

[math] a_{e} = \min\left( 46.5,\ 63,\ 54,\ 63 \right)\ \text{mm} = 46.5\ \text{mm} [math]

The capacity factor for a ply in bearing is 0.9:

[math] \phi V_{b} = \phi \min\left( 3.2\, d_{f}\, t_{i}\, f_{up},\ a_{e}\, t_{i}\, f_{up} \right) [math]

[math] \phi V_{b,pl} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (10\ \text{mm}) \times (410\ \text{MPa}),\ (46.5\ \text{mm}) \times (10\ \text{mm}) \times (410\ \text{MPa}) \right) = 171.59\ \text{kN} [math]

The edge distance term governs, so the vertical edge distance at the top and bottom of the plate controls the plate’s bearing capacity.

Bearing on the beam web

The beam is uncoped, so there is no vertical edge on the beam web near the bolts. The distances are to the next hole and to the end of the beam:

[math] a_{e5} = s_{p} – d_{h} + 0.5\, d_{f} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

[math] a_{e6} = l_{eh\_w} – 0.5\, d_{h} + 0.5\, d_{f} = (50\ \text{mm}) – 0.5 \times (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 49\ \text{mm} [math]

[math] a_{e7} = s_{g} – d_{h} + 0.5\, d_{f} = (75\ \text{mm}) – (22\ \text{mm}) + 0.5 \times (20\ \text{mm}) = 63\ \text{mm} [math]

[math] a_{e} = \min\left( 63,\ 49,\ 63 \right)\ \text{mm} = 49\ \text{mm} [math]

[math] \phi V_{b,beam} = (0.9) \times \min\left( 3.2 \times (20\ \text{mm}) \times (9.9\ \text{mm}) \times (440\ \text{MPa}),\ (49\ \text{mm}) \times (9.9\ \text{mm}) \times (440\ \text{MPa}) \right) = 192.1\ \text{kN} [math]

Bolt group bearing capacity

The weaker ply per bolt, scaled by the bolt group coefficient from Step 4:

[math] \phi V_{b} = \min\left( \phi V_{b,pl},\ \phi V_{b,beam} \right) C = \min\left( 171.59\ \text{kN},\ 192.1\ \text{kN} \right) \times (4.6497) = 797.82\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{b} = 797.82\ \text{kN} [math]

DCR = 150 kN / 797.82 kN = 0.188 ≤ 1.0, OK

The plate governs over the beam web even though the web is slightly thinner, because its 410 MPa tensile strength is lower than the beam’s 440 MPa and its edge distance term is smaller.

Step 6: Web side plate in shear (AS 4100 Clause 5.11.3)

The whole design shear passes down through the plate as vertical shear. A rectangular plate does not carry shear uniformly: the stress peaks at mid-depth. Clause 5.11.3 allows for that non-uniform distribution, which for a rectangular section brings the capacity down to 0.5 fy on the gross area, instead of the 0.6 fy used for a beam web:

[math] \phi V_{v} = \phi\, 0.5\, f_{yp}\, d_{i}\, t_{i} [math]

[math] \phi V_{v} = (0.9) \times 0.5 \times (260\ \text{MPa}) \times (320\ \text{mm}) \times (10\ \text{mm}) = 374.4\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{v} = 374.4\ \text{kN} [math]

DCR = 150 kN / 374.4 kN = 0.401 ≤ 1.0, OK

This is the highest load ratio in the connection, and it is set by the plate’s grade and size, not the bolts. A thin, lower-strength plate like this one yields before the bolts or welds, which keeps the connection flexible.

Step 7: Web side plate in bending (AS 4100 Clause 5.2.1)

The plate is a short cantilever from the face of the column to the bolt group, so the design shear causes bending in the plate at the support. The design section moment capacity of the rectangular plate, using its plastic section modulus:

[math] \phi M_{s} = \phi\, \frac{f_{yp}\, t_{i}\, d_{i}^{2}}{4} [math]

[math] \phi M_{s} = (0.9) \times \frac{(260\ \text{MPa}) \times (10\ \text{mm}) \times (320\ \text{mm})^{2}}{4} = 59.904\ \text{kNm} [math]

Expressed as the shear it can carry at the bolt group eccentricity:

[math] \phi V_{n} = \frac{\phi M_{s}}{e_{b}} = \frac{59.904\ \text{kNm}}{107.5\ \text{mm}} = 557.25\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{n} = 557.25\ \text{kN} [math]

DCR = 150 kN / 557.25 kN = 0.269 ≤ 1.0, OK

Step 8: Web side plate in block shear (AS 4100 Clause 9.1.9)

A block of the plate can tear out around the bolts: shear down the outer bolt column to the bottom edge, plus tension across the bolt columns to the free edge of the plate. With two bolt columns this is an L-shaped block.

Net area in tension, along the bottom bolt row:

[math] A_{nt} = \left[ l_{eh\_wp} + (n_{g} – 1)\, s_{g} – (n_{g} – 0.5)\, d_{h} \right] t_{i} [math]

[math] A_{nt} = \left[ (55\ \text{mm}) + (2 – 1)(75\ \text{mm}) – (2 – 0.5)(22\ \text{mm}) \right] \times (10\ \text{mm}) = 970\ \text{mm}^{2} [math]

Gross and net areas in shear, along the bolt column:

[math] A_{gv} = \left[ l_{ev\_wp} + (n_{p} – 1)\, s_{p} \right] t_{i} = \left[ (47.5\ \text{mm}) + (4 – 1)(75\ \text{mm}) \right] \times (10\ \text{mm}) = 2725\ \text{mm}^{2} [math]

[math] A_{nv} = \left[ l_{ev\_wp} + (n_{p} – 1)\, s_{p} – (n_{p} – 0.5)\, d_{h} \right] t_{i} = \left[ (47.5\ \text{mm}) + (3)(75\ \text{mm}) – (3.5)(22\ \text{mm}) \right] \times (10\ \text{mm}) = 1955\ \text{mm}^{2} [math]

The tension stress is uniform, so [mathin] k_{bs} = 1 [mathin], and the capacity factor for block shear is 0.75:

[math] \phi R_{bs} = \phi \min\left( 0.6\, f_{up}\, A_{nv} + k_{bs}\, f_{up}\, A_{nt},\ 0.6\, f_{yp}\, A_{gv} + k_{bs}\, f_{up}\, A_{nt} \right) [math]

[math] \phi R_{bs} = (0.75) \times \min\left( 0.6 \times (410)(1955) + (1)(410)(970),\ 0.6 \times (260)(2725) + (1)(410)(970) \right) \times 10^{-3} = 617.1\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi R_{bs} = 617.1\ \text{kN} [math]

DCR = 150 kN / 617.1 kN = 0.243 ≤ 1.0, OK

The second term, shear yielding on the gross area, is the smaller one, so the block would yield along the bolt column before it ruptured.

Step 9: Supported member in shear (AS 4100 Clause 5.11.2)

At the connection the beam web carries the full end shear. The beam is uncoped, so the whole web depth is available. First, the web has to be stocky enough to reach shear yield without buckling:

[math] \frac{d_{p}}{t_{w}} = 43.232 \le \frac{82}{\sqrt{f_{y} / 250}} = 74.855 [math]

The web is not slender, so the design shear capacity is the yield capacity of the web:

[math] \phi V_{vo} = \phi\, 0.6\, f_{yb}\, d_{bm}\, t_{wb} = (0.9) \times 0.6 \times (300\ \text{MPa}) \times (460\ \text{mm}) \times (9.9\ \text{mm}) = 737.75\ \text{kN} [math]

[math] V^{*} = 150\ \text{kN} \le \phi V_{vo} = 737.75\ \text{kN} [math]

DCR = 150 kN / 737.75 kN = 0.203 ≤ 1.0, OK

For a column flange support the module does not run a local check of the supporting member. The column flange enters the design through the minimum weld size in Step 2.

Summary of checks

Design checkDesign action effectDesign capacityDCRResult
Connection detailing limitations20 mm20 mm1.000PASS
Minimum weld size7.5 mm8 mm0.938PASS
Weld to supporting member150 kN851.515 kN0.176PASS
Bolt group in shear150 kN430.692 kN0.348PASS
Bolt group in bearing on plate and beam web150 kN797.819 kN0.188PASS
Web side plate in shear150 kN374.4 kN0.401PASS
Web side plate in bending150 kN557.247 kN0.269PASS
Web side plate in block shear150 kN617.1 kN0.243PASS
Supported member in shear150 kN737.748 kN0.203PASS

The connection passes every check. Two ratios sit near 1.0, and neither one compares a design action with a capacity. The detailing check is 1.000 because the beam end clearance was set at the 20 mm minimum, and the minimum weld size check is 0.938 because the 8 mm weld is the next size above the 7.5 mm needed to develop the plate. Of the checks that compare the design shear with a design capacity, the web side plate in shear governs at 0.401, followed by the bolt group in shear at 0.348.

Auto Design is available for the web side plate in the AS 4100 module. It changes the bolts, plate and welds until every check passes, and keeps your members and design actions as entered. See the Auto Design page for the AS 4100 preferences it works to.

What to change if a check fails

  • Detailing limits: adjust the pitch, edge distances or plate depth to the limits in Step 1. A plate deeper than the flat of the beam web will not fit between the root radii, so add a bolt column rather than a row if the depth is maxed out.
  • Minimum weld size: increase the fillet weld size to at least 0.75 times the plate thickness and the Table 9.6.3.2 minimum.
  • Weld capacity: increase the weld size, use a stronger electrode, or make the plate deeper to lengthen the welds.
  • Bolt group in shear: add a bolt row, which raises C, use a larger bolt or a higher bolt grade, or move the bolts closer to the support to reduce the eccentricity.
  • Bolt bearing: increase the vertical edge distance on the plate, use a thicker plate, or add bolts. If the beam web governs, add bolts or use a larger bolt.
  • Plate shear, bending or block shear: make the plate deeper, or thicker. A thicker plate also raises the minimum weld size and makes the connection stiffer, so prefer a deeper plate where the beam web allows.
  • Beam web in shear: this depends only on the beam, so use a heavier section.

Frequently asked questions

Why is the bolt group designed for a 107.5 mm eccentricity?

The module takes the design shear at the face of the support and designs the bolt group for the full distance from there to the centroid of the bolts: 70 mm to the first bolt column plus half the 75 mm column pitch. The welds are then designed for the shear alone, because the support is treated as flexible. This is the conservative side for the bolts, which are the more brittle part of the load path.

Why does the plate shear check use 0.5 fy and not 0.6 fy?

AS 4100 Clause 5.11.3 covers members where the shear stress is not uniform across the section. In a solid rectangle the stress peaks at mid-depth at 1.5 times the average, so the capacity of the plate works out to 0.5 fy on the gross area. A beam web, where the shear stress is close to uniform, uses 0.6 fy under Clause 5.11.2.

Why was the 150 kN design shear not increased to the Clause 9.1.4 minimum?

Clause 9.1.4 asks for a simple connection to be designed for at least the lesser of 0.15 times the beam’s design shear capacity and 40 kN. For this 460 UB 82.1 that is the lesser of 0.15 x 737.75 kN and 40 kN, so the minimum is 40 kN. The 150 kN entered is larger, so it is used as is. For a lightly loaded beam the minimum can govern, and the report shows it in the same place.

Why is the weld 8 mm when Table 9.6.3.2 only asks for 6 mm?

Table 9.6.3.2 sets the smallest weld that can be laid safely on a 25 mm column flange. The connection also needs the weld to be stronger than the plate, so that the plate yields first and the connection stays ductile. The program sizes this at 0.75 times the plate thickness, 7.5 mm for a 10 mm plate, and 8 mm is the next practical size.

Do I need slip-critical bolts for a web side plate?

No. A web side plate is a bearing-type connection, and 8.8/S bolts snug tightened are the usual choice, as in this example. If you choose 8.8/TF or 10.9/TF bolts, or use oversize or slotted holes that make the group friction type, the report adds the serviceability check of Clause 9.2.3.1.

Is the column checked in this design?

For a column flange support, the column enters through the weld: the 25 mm flange sets the Table 9.6.3.2 minimum weld size. The module runs a local capacity check of the supporting member only for column web and beam web supports, where a thin web takes the plate’s weld directly.

Design a web side plate connection for free

Every number on this page comes from one solve. Pick AS 4100:2020 and the web side plate, enter your beam, support, bolts and design shear, and see each of these checks in your browser. There is nothing to install.

The SkyCiv Connection Design module is the connection design software behind this example. It gives you the full calculation report with every equation and your numbers in it, like the steps above, plus every design capacity and DCR, for AS 4100:2020 shear connections, moment connections and splices. The bolt calculator and weld calculator cover the bolt group and weld checks on their own.

References

Harold Munalem, Product Manager for SkyCiv Connection Design

Harold Munalem
Product Manager, Connection Design
10+ years in steel connection design
LinkedIn

How can we help?

×

Updated November 24, 2026

Still stuck? Contact us