When a directly welded web connection carries an axial force as well as the end shear, two things change in the design to AISC 360. The welds now see a resultant force at an angle to their axis, which is larger than the shear alone but also earns the directional strength increase of Eq. J2-5. And the axial force is delivered to the column flange as a concentrated force, so the column has to be checked for flange local bending, web local yielding and, bij compressie, web local crippling.
This page works the same connection as the shear-only directly welded web example, a W18x50 beam web welded to the flange of a W14x90 column with 3/16 in E70XX-hoeklassen 15.5 in long on both sides of the web, and adds an axial force of 132 kip in tension or compression to the 38 kip end shear (LRFD). Het ontwerp is naar AISC 360-16 en de AISC-handleiding 15e editie. Elke vergelijking wordt uitgeschreven met zijn cijfers, in dezelfde volgorde als het berekeningsblad waarop de SkyCiv Connection Design module produceert voor deze verbinding.
What the axial force adds to a directly welded web connection
A beam in a braced frame or a diaphragm chord often carries an axial force along with its end reaction, for example as a strut or collector. With a directly welded web, that force has no plate or bolts to pass through: it goes straight from the web into the two fillet welds and from them into the column flange.
The member sizes, weld and the checks of the minimum weld size and the beam web in shear are the same as in the shear-only example, and give the same results. This page focuses on the weld under combined load and on the two support checks the axial force adds. The other shear connection types are on the afschuifverbindingen pagina.

Verhoging van de voorbeeldverbinding, met de 38 kipschaar en de 132 kip tension or compression at the beam end.

Dezelfde verbinding in SkyCiv Connection Design, met de Directly Welded Web-configuratie op het tabblad Assemblage.
Directly welded web shear and axial design: de stappen in één oogopslag
- Controleer de minimale hoeklasgrootte.
- Check the welds for the resultant of the shear and the axial force.
- Controleer het liggerlijf op afschuiving.
- Check the column for the axial tension: flange local bending and web local yielding.
- Check the column for the axial compression: web local crippling and web local yielding.
Ontwerp invoer voor dit voorbeeld
De ontwerpcode is AISC 360-16 LRFD. Sectie-eigenschappen komen uit de AISC-handleiding. De kdes van de kolom, gebruikt bij lokale webopbrengst, is 1.31 in.
| Item | Symbool | Waarde |
|---|---|---|
| Gefactoriseerde afschuiving | [mathin] V_{u} [mathin] | 38 kip |
| Gefactoriseerde axiale spanning | [mathin] T_{u} [mathin] | 132 kip |
| Gefactoriseerde axiale compressie | [mathin] C_{u} [mathin] | 132 kip |
| Beam | Verticale afschuiving van dode belasting, A992 | |
| Straal diepte / dikte van het web | [mathin] d_{bm},\ t_{wb} [mathin] | 18 in / 0.355 in |
| Kolom | B14x90, A992 | |
| Kolom diepte / dikte van het web | [mathin] d_{sup},\ t_{ws} [mathin] | 14 in / 0.44 in |
| Breedte van de kolomflens / dikte | [mathin] b_{fs},\ t_{fs} [mathin] | 14.5 in / 0.71 in |
| Kolom kdes | [mathin] k_{des} [mathin] | 1.31 in |
| Balk- en kolomopbrengst / trekspanning | [mathin] F_{y},\ F_{u} [mathin] | 50 KSI / 65 KSI |
| Elasticiteitsmodulus | [mathin] E [mathin] | 29000 KSI |
| Lassen | E70XX filet, beide kanten van het web | |
| Lasgrootte / length on each side | [mathin] W,\ L_{wv} [mathin] | 0.1875 in / 15.5 in |
Stap 1: Minimale hoeklasgrootte (AISC 360-16 J2.2b, Tabel J2.4)
The axial force does not change this check. The thinner part joined is the 0.355 in balkenweb, so the Table J2.4 minimum is 3/16 in, and the weld is 3/16 in.
DCR = 0.1875 in / 0.1875 in = 1.000 ≤ 1.0, OK
Stap 2: Welds under the resultant of shear and axial force (AISC 360-16 J2.4)
The base metal limit and the effective length are the same as for shear alone, half the web thickness against the column flange, and twice the weld size off each end:
[math] D_{max} = \frac{\min\left( t_{fs} F_{us},\ \frac{t_{wb}}{2} F_{ub} \right)}{3.09\ \text{kip/in}} = \frac{\min\left( (0.71\ \text{in})(65\ \text{ksi}),\ (0.1775\ \text{in})(65\ \text{ksi}) \right)}{3.09\ \text{kip/in}} = 3.7338 [math]
[math] L_{w} = 2\left[ L_{wv} – 2W \right] = 2 \times \left[ 15.5\ \text{in} – 2 \times 0.1875\ \text{in} \right] = 30.25\ \text{in} [math]
What changes is the load. The welds now carry the vertical shear along their axis and the axial force across it. The demand is the resultant of the two, at an angle to the weld axis:
[math] R_{u} = \sqrt{V_{u}^{2} + T_{u}^{2}} = \sqrt{(38\ \text{kip})^{2} + (132\ \text{kip})^{2}} = 137.36\ \text{kip} [math]
[math] \theta_{u} = \tan^{-1}\left( \frac{T_{u}}{V_{u}} \right) = \tan^{-1}\left( \frac{132}{38} \right) = 73.94^{\circ} [math]
A fillet weld loaded across its axis is stronger than one loaded along it, Stapelcapaciteit schatten. J2-5 rewards that with the directional term:
[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left( W,\ \frac{D_{max}}{16} \right) \left[ 1 + 0.5 \left( \sin\theta_{u} \right)^{1.5} \right] L_{w} [math]
[math] \phi R_{n} = (0.75) \times 0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left( 0.1875\ \text{in},\ \frac{3.7338}{16} \right) \times \left[ 1 + 0.5 \left( \sin 73.94^{\circ} \right)^{1.5} \right] \times (30.25\ \text{in}) = 185.84\ \text{kip} [math]
DCR = 137.36 kip / 185.84 kip = 0.739 < 1.0, OK
Dit is de controle van het bestuur. The same welds are good for 126.33 kip under shear alone, so the load angle adds about 47% to their strength. The demand grows faster, hoewel, van 38 kip to 137.36 kip, and the ratio rises from 0.301 naar 0.739. The tension and compression cases have the same resultant, so one weld check covers both.
Stap 3: Balklijf in afschuiving (AISC 360-16 J4.2)
The beam web still carries only the 38 kip schaar, over its full depth:
[math] \phi R_{n} = \phi\, 0.6\, F_{yb}\, d_{bm}\, t_{wb} = (1) \times 0.6 \times (50\ \text{ksi}) \times (18\ \text{in})(0.355\ \text{in}) = 191.7\ \text{kip} [math]
DCR = 38 kip / 191.7 kip = 0.198 < 1.0, OK
Stap 4: Kolom onder de axiale spanning (AISC 360-16 J10.1, J10.2)
The axial tension pulls on the column flange along the line of the weld. AISC 360-16 J10 covers this as a concentrated force on the flange: lokale buiging van de flens (J10.1), where it applies, en web-lokale opbrengst (J10.2). Weblokaal verlammend (J10.3) is for compressive forces only.
Flens lokale buiging
J10.1 does not require a flange local bending check when the length of loading measured across the member flange is less than 0.15 times the flange width:
[math] 0.15\, b_{f} = 0.15\, b_{fs} = 0.15 \times (14.5\ \text{in}) = 2.175\ \text{in} [math]
The load is delivered by the beam web, so the loaded length across the column flange is the web thickness, [mathin] t_{wb} = 0.355\ \text{in} [mathin]. That is less than 2.175 in, so flange local bending need not be checked.
Web lokale opbrengst
The force spreads through the column flange into the web over the weld length plus [mathin] 5k [mathin] (Eq. J10-2):
[math] \phi R_{n} = \phi\, F_{ys}\, t_{ws} \left( 5 k_{des} + L_{wv} \right) = (1) \times (50\ \text{ksi}) \times (0.44\ \text{in}) \times \left( 5 \times 1.31\ \text{in} + 15.5\ \text{in} \right) = 485.1\ \text{kip} [math]
DCR = 132 kip / 485.1 kip = 0.272 < 1.0, OK
Stap 5: Kolom onder de axiale compressie (AISC 360-16 J10.2, J10.3)
In compression the beam pushes on the column flange, so web local crippling joins web local yielding. Weblokaal verlammend, Eq. J10-4, with the weld length as the bearing length:
[math] \phi R_{n,wlc} = \phi\, 0.8\, t_{ws}^{2} \left[ 1 + 3\left( \frac{L_{wv}}{d_{sup}} \right) \left( \frac{t_{ws}}{t_{fs}} \right)^{1.5} \right] \sqrt{\frac{E F_{ys} t_{fs}}{t_{ws}}}\, Q_{f} [math]
[math] \phi R_{n,wlc} = (0.75) \times 0.8 \times (0.44\ \text{in})^{2} \left[ 1 + 3\left( \frac{15.5}{14} \right) \left( \frac{0.44}{0.71} \right)^{1.5} \right] \sqrt{\frac{(29000\ \text{ksi})(50\ \text{ksi})(0.71\ \text{in})}{0.44\ \text{in}}} \times (1) = 465.59\ \text{kip} [math]
Web local yielding is the same as in tension, 485.1 kip. The lower of the two governs:
[math] \phi R_{n} = \min\left( 465.59\ \text{kip},\ 485.1\ \text{kip} \right) = 465.59\ \text{kip} [math]
DCR = 132 kip / 465.59 kip = 0.284 < 1.0, OK
Both column checks pass with room to spare, so this W14x90 needs no stiffeners or web doubler for these limit states.
Samenvatting van controles
| Ontwerpcontrole | Vraag naar | Capaciteit | DCR | Resultaat |
|---|---|---|---|---|
| Minimale hoeklasgrootte | 0.1875 in | 0.1875 in | 1.000 | DOORGANG |
| Welds under shear and axial force | 137.36 kip | 185.84 kip | 0.739 | DOORGANG |
| Balklijf in afschuiving | 38 kip | 191.7 kip | 0.198 | DOORGANG |
| Kolom onder axiale spanning | 132 kip | 485.1 kip | 0.272 | DOORGANG |
| Kolom onder axiale compressie | 132 kip | 465.59 kip | 0.284 | DOORGANG |
Every check in this directly welded web shear and axial connection design passes. De 1.000 verhouding is de minimale hoeklasmaat, ONTWERP WERKSTROOMPROCES 3/16 in las voldoet precies. Van de krachtcontroles, de lassen regeren 0.739 onder de 137.36 kip resultant, tegen 0.301 for the same welds under shear alone. The column checks for the axial force come next, with web local crippling in compression at 0.284.
Auto Design is available for the directly welded web connection with shear and axial load to a column flange. Het verandert de ontwerpvariabelen van de verbinding totdat elke controle slaagt, en houdt uw leden en ladingen zoals ingevoerd. Zie de Automatisch ontwerp pagina voor de voorkeuren waarmee het werkt.
Wat u moet wijzigen als een controle mislukt
- Lassterkte: lengthen the welds, increase the weld size up to the base metal limit of the half web, of gebruik een sterkere elektrode. Past that limit a larger weld adds no strength.
- Column web local yielding or crippling: a longer weld spreads the force over more of the column web and raises both strengths. Otherwise use a column with a thicker web, or add stiffeners or a web doubler.
- Flens lokale buiging: with a directly welded web it only applies if the loaded length across the flange reaches 0.15 times the flange width.
- Minimum weld size or beam web shear: as for shear alone, meet the Table J2.4 minimum, of gebruik een zwaardere balk.
Veelgestelde vragen
Why does the weld get stronger when the axial force is added?
The strength of a fillet weld depends on the direction of the load. Under pure shear the load runs along the weld, and the directional term of Eq. J2-5 wel 1. Met 132 kip of axial force the resultant turns to 73.94 degrees from the weld axis, and the term rises toward its maximum of 1.5 for a load at 90 graden. Here it lifts the weld strength from 126.33 kip to 185.84 kip.
Why is only one weld check reported for both tension and compression?
The axial force is 132 kip hoe dan ook, so the resultant on the welds is the same 137.36 kip at the same angle. The sign of the axial force matters for the column, which is why the support is checked separately for tension and compression.
Why is flange local bending not checked?
J10.1 only requires it when the force is spread across a meaningful width of the column flange. Here the force comes in through a 0.355 in balkenweb, which is much less than 0.15 keer de 14.5 in flensbreedte, 2.175 in, so J10.1 does not require the check.
Why is web local crippling checked only in compression?
Web local crippling is the buckling of the column web under a compressive force pushed through the flange. A tensile force pulls the web straight, so J10.3 applies to compressive forces only, while web local yielding applies to both.
Hoe zou dit veranderen voor AISC ASD in plaats van LRFD?
De grenstoestanden en nominale sterkten zijn hetzelfde. Met AISC ASD vergelijkt u krachten op serviceniveau met de nominale sterkte gedeeld door een veiligheidsfactor: 0.75 for the welds and for web local crippling becomes a safety factor of 2.00, en 1.00 for web shear yielding and web local yielding becomes 1.50.
Ontwerp gratis een direct gelaste webverbinding
Elk getal op deze pagina komt uit één oplossing. Pick the directly welded web configuration with shear and axial load, kom je straal binnen, ondersteuning, weld and forces, en de gratis rekenmachine voert al deze controles uit in uw browser zonder dat u iets hoeft te installeren.
De SkyCiv Connection Design-module is de verbindingsontwerpsoftware achter dit voorbeeld. Het geeft u het volledige rekenrapport met elke vergelijking en uw getallen erin, zoals de bovenstaande stappen, plus elke capaciteit en DCR, voor AISC 360-22 en AISC 360-16 (LRFD en ASS) en AS 4100:2020. De las rekenmachine dekt afzonderlijk hoeklasgroepen af.
Referenties
- AISC 360-16, Specificatie voor constructieve stalen gebouwen: J2.2b (Tabel J2.4), J2.4 (Eq. J2-4, J2-5), J4.2 (Eq. J4-3), J10.1, J10.2 (Eq. J10-2), J10.3 (Eq. J10-4).
- AISC-handleiding voor staalconstructie, 15e editie: Een deel 9 (Eq. 9-2), Een deel 10 (effectieve laslengte).
- Ontwerp van staalverbindingen met AISC 360-16
- Automatisch ontwerp in SkyCiv-verbindingsontwerp
Harold Munalem
Productmanager, Verbindingsontwerp
10+ jaar in het ontwerpen van stalen verbindingen
LinkedIn