To design a bolted flange plate moment connection to a rectangular HSS column to AISC 360-16, you turn the beam moment into a tension and compression force in each flange, controleer de flensplaten, bolts and beam flanges for that force, and then check what the force does to the tube: the weld to the HSS face, local yielding of the plate on a flexible wall, and local yielding of the HSS sidewalls. A single plate on the beam web carries the shear.

This page works through one example: a W18x50 beam framing into the 4 in face of an HSS8x4x1/2 column, met 38 kip-ft moment, 19 kipschaar en 66 kip axial under LRFD, 3/4 in Grade 50 flange plates on four 1 elk in A490-SC-bouten, en een 3/8 in A36 shear plate. Elke vergelijking wordt uitgeschreven met zijn cijfers, in dezelfde volgorde als het berekeningsblad SkyCiv Connection Design module daarvoor produceert.

What is a flange plate moment connection to an HSS column?

A flange plate moment verbinding has one plate on the top flange and one on the bottom flange of the beam. Each plate is shop-welded to the column and field-bolted to the beam flange, so the moment passes through the plates as a tension and compression couple. A shear plate on the web takes the beam reaction. For a W-shape column the plates weld to the column flange, as in Hoe een flensplaatmomentverbinding te ontwerpen.

On an HSS column the plates weld straight onto the tube wall, which is much more flexible than a column flange. A plate pulling on the middle of a thin wall cannot spread its force evenly across its width, so AISC reduces the plate to an effective width, and the sidewalls of the tube are checked for the force coming in from the corners. Those HSS checks are the part of the design this page adds to the W-shape example.

You can run this connection in the rekenmachine voor flensplaatverbindingen.

Verhoging: W18x50 beam with bolted top and bottom flange plates and a shear plate, welded to an HSS8x4x1/2 column

Verhoging van de voorbeeldverbinding. The flange plates are welded to the HSS face and bolted to the beam flanges; the shear plate carries the reaction.

Plan section A-A of the 3/4 in x 6 1/2 in flange plate with four 1 in A490-SC-bouten, welded to the 4 in HSS face

Sectie A-A, a plan cut through the top flange plate, showing the four bolts at a 3 5/8 in gage and the plate against the 4 in HSS face.

3D view of the flange plate moment connection: W18x50 beam framing into a rectangular HSS8x4x1/2 column

3D-weergave van de verbinding in SkyCiv Connection Design.

How do you design a flange plate moment connection to an HSS column? De stappen in één oogopslag

The report has two sections: the flange plates (Stappen 1 naar 14) and the shear plate (Stappen 15 naar 24).

  1. Detailleringslimieten bij de liggerflens.
  2. Flange bolts in slip under the flange force.
  3. Bolt bearing on the flange plate.
  4. Bolt bearing on the beam flange.
  5. Blokschaar van de flensplaat.
  6. Blokafschuiving van de liggerflens.
  7. Spanningsopwekking en breuk van de flensplaat.
  8. Tension rupture of the beam flange.
  9. Buigbreuk van de balk bij de flensboutgaten.
  10. Compression of the flange plate.
  11. Detailing limit at the HSS face.
  12. Fillet weld from the flange plate to the HSS face.
  13. Local yielding of the flange plate on the HSS wall.
  14. Local yielding of the HSS sidewalls.
  15. Detailing limits of the shear plate at the beam.
  16. Shear plate bolt group.
  17. Bearing on the shear plate.
  18. Lager op het balklijf.
  19. Effectieve sterkte van de lijfboutgroep.
  20. Block shear of the shear plate.
  21. Shear yielding and rupture of the shear plate.
  22. Detailing limits of the shear plate at the HSS wall.
  23. Weld from the shear plate to the HSS wall.
  24. HSS-muurponsen.

Ontwerp invoer voor dit voorbeeld

De ontwerpcode is AISC 360-16 LRFD. Sectie-eigenschappen komen uit de AISC-handleiding. How the loads are entered is explained in belastingen en belastingcombinaties.

ItemSymboolWaarde
Factored moment (sterke as)[mathin] M_{ux} [mathin]38 kip-ft
Gefactoriseerde afschuiving[mathin] V_{u} [mathin]19 kip
Gefactoriseerde axiale spanning / compressie[mathin] T_{u},\ C_{u} [mathin]66 kip / 66 kip
BeamVerticale afschuiving van dode belasting, ASTM A992
Straal diepte / dikte van het web[mathin] d_{bm},\ t_{wb} [mathin]18 in / 0.355 in
Breedte balkflens / dikte[mathin] b_{fb},\ t_{fb} [mathin]7.5 in / 0.57 in
Straalgebied / opbrengst / treksterkte[mathin] A,\ F_{yb},\ F_{ub} [mathin]14.7 in² / 50 KSI / 65 KSI
KolomHSS8x4x1/2, ASTM A500 Gr. C
Width of the HSS face the plates weld to[mathin] b [mathin]4 in
HSS-diepte / ontwerp wanddikte[mathin] h,\ t [mathin]8 in / 0.465 in
Workable flat of the face[mathin] W_{flat} [mathin]2.875 in
Kolomopbrengst / treksterkte[mathin] F_{ys},\ F_{us} [mathin]50 KSI / 62 KSI
Flange plate itemSymboolWaarde
FlensplatenPL 3/4 X 6 1/2 X 6 1/2, ASTM A572 Gr. 50 (50 / 65 KSI)
Plaat breedte / lengte / dikte[mathin] b_{fp},\ L_{fp},\ t_{fp} [mathin]6.5 in / 6.5 in / 0.75 in
Flens bouten1 in A490-SC, Klasse A, eerste klasse, 1 afschuifvlak
GatenFlens plaat: te groot (OVS). Balk flens: Slankheidsverhouding voor Axial (soa)
Boutlijnen / maat[mathin] n_{r},\ g_{a} [mathin]2 / 3.625 in
Bolts per line / spatiëring[mathin] n_{c},\ s_{c} [mathin]2 / 3 in
Plaatrandafstanden, over / langs de balk[mathin] L_{ev\_fp},\ L_{eh\_fp} [mathin]1.4375 in / 1.5 in
Beam flange edge distances, over / along[mathin] L_{ev\_bf},\ L_{eh\_bf} [mathin]1.9375 in / 1.5 in
Erection gap1/4 in
Weld to HSS face1/2 in filet, E70XX
Shear plate itemSymboolWaarde
Shear platePL 3/8 X 3 1/2 X 9, ASTM A36 (36 / 58 KSI)
Webbouten1 in A490-N, draden inbegrepen
GatenBord: horizontaal met korte sleuven (HSSL). Balk web: Slankheidsverhouding voor Axial (soa)
Rijen vastschroeven / spatiëring / kolommen[mathin] n_{r},\ s_{r},\ n_{c} [mathin]3 / 3 in / 1
Edge distances / weld to bolt line[mathin] L_{e},\ a [mathin]1.5 in / 2 in
Weld to HSS face3/16 in filet aan beide kanten, E70XX

Flange plate section

Stap 1: Detailleringslimieten bij de liggerflens (AISC 360-16 J3.3, J3.4)

The bolt gage across the flange, the spacing along it and the edge distances on both the plate and the beam flange are checked against the J3.3 and Table J3.4 limits for a 1 in bout, with the oversized-hole increment on the plate.

DetailleringslimietBeperken (in)Werkelijk (in)DCRResultaat
Minimale maat3.6253.6251.000DOORGANG
Minimale boutkolomafstand2.6673.0000.889DOORGANG
Maximale boutkolomafstand6.0003.0000.500DOORGANG
Minimale verticale randafstand plaat1.3751.4380.956DOORGANG
Minimale horizontale randafstand plaat1.3751.5000.917DOORGANG
Minimale verticale randafstand van liggerflens1.2501.9380.645DOORGANG
Minimale horizontale randafstand liggerflens1.2501.5000.833DOORGANG

The gage equals the module’s minimum gage, so that row sits at exactly 1.000:

[math] DCR = \frac{3.625\,in}{3.625\,in} = 1.000 [math]

DCR = 1.000, OK

Stap 2: Flange bolts in slip under the flange force (AISC 360-16 J3.8)

The moment becomes a force in each flange over the distance between flange centers, and half the axial force is added to it:

[math] P_{uF} = \frac{M_{ux}}{d_{bm} – t_{fb}} + \frac{P_{u}}{2} = \frac{38\,kip\text{-}ft}{18\,in – 0.57\,in} + \frac{66\,kip}{2} = 59.162\,kip [math]

This flange force is the demand for every check in the flange plate section. The four bolts are slip-critical, Eq. J3-4, with the report’s filler factor of 0.85:

[math] \phi R_{n} = \phi\, \mu\, D_{u}\, h_{f}\, T_{b}\, N_{s}\, n_{r}\, n_{c} = (0.85) \times (0.3) \times (1.13) \times (0.85) \times (64\,kip) \times (1) \times (2) \times (2) = 62.701\,kip [math]

DCR = 59.162 kip / 62.701 kip = 0.944 < 1.0, OK

Stap 3: Bolt bearing on the flange plate (AISC 360-16 J3.10)

The force runs along the beam, so the bolts bear toward the plate end. Met de 1.25 in oversized hole:

[math] l_{c1} = 1.5 – \frac{1.25}{2} = 0.875\,in, \qquad l_{c2} = 3 – 1.25 = 1.75\,in [math]

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.875, 2.4) \times 0.75 \times 65 \times 2 + \min(1.2 \times 1.75, 2.4) \times 0.75 \times 65 \times 2 \times 1 \right] = 230.34\,kip [math]

DCR = 59.162 kip / 230.34 kip = 0.257 < 1.0, OK

Stap 4: Bolt bearing on the beam flange (AISC 360-16 J3.10)

[math] l_{c1} = 1.5 – \frac{1.125}{2} = 0.9375\,in, \qquad l_{c2} = 1.875\,in [math]

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.57 \times 65 \times 2 + \min(1.2 \times 1.875, 2.4) \times 0.57 \times 65 \times 2 \times 1 \right] = 187.57\,kip [math]

DCR = 59.162 kip / 187.57 kip = 0.315 < 1.0, OK

Stap 5: Blokschaar van de flensplaat (AISC 360-16 J4.3)

Three tear-out shapes are checked, all with [mathin] U_{bs} = 1 [mathin] Stapelcapaciteit schatten. J4-5:

[math] \phi R_{n} = \phi \left( 0.6 F_{up} A_{nv} + U_{bs} F_{up} A_{nt} \le 0.6 F_{yp} A_{gv} + U_{bs} F_{up} A_{nt} \right) [math]

PatroonGem (in²)Ant (in²)Mier (in²)phi Rn (kip)
L: één afschuifvlak, spanning over de bouten tot één rand3.3751.89842.3203168.64
U: twee schuifvlakken, spanning tussen de boutlijnen6.753.79691.7344195.61
2L: twee schuifvlakken, spanning van elke boutlijn tot aan de rand6.753.79691.1719168.19

For the governing 2L pattern:

[math] A_{nt} = 2 \times 0.75 \left[ 1.4375 – 0.5 \times (1.25 + 0.0625) \right] = 1.1719\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.7969 + 65 \times 1.1719 \le 0.6 \times 50 \times 6.75 + 65 \times 1.1719 \right) = 168.19\,kip [math]

DCR = 59.162 kip / 168.19 kip = 0.352 < 1.0, OK

Stap 6: Blokafschuiving van de liggerflens (AISC 360-16 J4.3)

The beam flange tears out as two outer strips:

[math] A_{nt} = 0.57 \left[ 7.5 – 3.625 – 1 \times (1.1875) \right] = 1.5319\,in^{2} [math]

[math] A_{gv} = 2 \times 0.57 \left[ 1.5 + 3 \right] = 5.13\,in^{2}, \qquad A_{nv} = 2 \times 0.57 \left( 4.5 – 1.5 \times 1.1875 \right) = 3.0994\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.0994 + 65 \times 1.5319 \le 0.6 \times 50 \times 5.13 + 65 \times 1.5319 \right) = 165.34\,kip [math]

DCR = 59.162 kip / 165.34 kip = 0.358 < 1.0, OK

Stap 7: Spanningsopwekking en breuk van de flensplaat (AISC 360-16 J4.1)

[math] \phi R_{n\_ty} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]

[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.75 \left[ 6.5 – 2 \times (1.3125) \right] = 141.68\,kip [math]

DCR = 59.162 kip / 141.68 kip = 0.418 < 1.0, OK

Stap 8: Tension rupture of the beam flange (AISC 360-16 D3, J4.1)

The flange force is taken by half the beam’s area, less the two flange holes, with the shear lag factor U = 0.283 from Table D3.1 case 2:

[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.283 \left[ 0.5 \times 14.7 – 2 \times (1.1875) \times 0.57 \right] = 82.726\,kip [math]

DCR = 59.162 kip / 82.726 kip = 0.715 < 1.0, OK

Stap 9: Buigbreuk van de balk bij de flensboutgaten (AISC 360-16 F13.1)

[math] A_{fg} = 7.5 \times 0.57 = 4.275\,in^{2}, \qquad A_{fn} = 4.275 – 2 \times (1.1875) \times 0.57 = 2.9213\,in^{2} [math]

With Fy / Fu = 0.76923, niet meer dan 0.8, Yt = 1. Vervolgens:

[math] F_{u} A_{fn} = 189.88\,kip \lt Y_{t} F_{y} A_{fg} = 213.75\,kip [math]

so the holes reduce the flexural strength and Eq. F13-1 applies, with the beam’s elastic modulus of 89.005 in³:

[math] M_{n} = \frac{F_{ub} A_{fn}}{A_{fg}}\, S_{x} = \frac{65 \times 2.9213}{4.275} \times 89.005 = 329.44\,kip\text{-}ft [math]

[math] \phi R_{n} = \frac{0.9\, M_{n}}{d_{bm} – t_{fb}} = \frac{0.9 \times 329.44\,kip\text{-}ft}{18\,in – 0.57\,in} = 204.13\,kip [math]

DCR = 59.162 kip / 204.13 kip = 0.290 < 1.0, OK

Stap 10: Compression of the flange plate (AISC 360-16 J4.4)

KL/r of the plate is no more than 25, dus vgl. J4-6 applies with no buckling reduction:

[math] \phi R_{n} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]

DCR = 59.162 kip / 219.38 kip = 0.270 < 1.0, OK

Stap 11: Detailing limit at the HSS face

DetailleringslimietBeperken (in)Werkelijk (in)DCRResultaat
Maximale hoeklasgrootte per liggerspeling0.5000.5001.000DOORGANG

 De  1/2 in weld exactly fills the available clearance, wat is toegestaan:

DCR = 1.000, OK

Stap 12: Fillet weld from the flange plate to the HSS face (AISC 360-16 K1, K5, J2.4)

This is where the HSS changes the design. The base metal limit first, from Manual Eq. 9-2:

[math] D_{max} = \frac{(0.375)(65) \le (0.465)(62)}{3.09} = 7.8883 [math]

 De  6.5 in plaat is breder dan de 4 in HSS face. The report allows that, but only the width over the face delivers load into it:

[math] B_{p,eff} = b_{fp} \le b = \min(6.5\,in, 4\,in) = 4\,in [math]

Eq. K1-1 then reduces it to the effective width:

[math] B_{e} = \left( \frac{10 t}{b} \right) \left( \frac{F_{ys}\, t}{F_{yp}\, t_{fp}} \right) B_{p,eff} \le B_{p,eff} = \left( \frac{10 \times 0.465}{4} \right) \left( \frac{50 \times 0.465}{50 \times 0.75} \right) \times 4 = 2.883\,in [math]

Per K5 the effective weld length is 2Be, and the report also caps Be at the workable flat:

[math] L_{w} = 2 \left( B_{e} \le W_{flat} \right) = 2 \times \min(2.883, 2.875) = 5.75\,in [math]

[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.5, \frac{7.8883}{16}\right) \times 5.75 = 63.144\,kip [math]

DCR = 59.162 kip / 63.144 kip = 0.937 < 1.0, OK

Stap 13: Local yielding of the flange plate on the HSS wall (AISC 360-16 K1, Ontwerpgids 24)

The same effective width idea limits the force the plate can deliver into the wall. The report uses φ = 0.95 from AISC Design Guide 24, Tafel 7-2:

[math] \phi R_{n} = \phi \left( \frac{10\, t^{2}\, F_{ys}\, B_{p,eff}}{b} \le F_{yp}\, t_{fp}\, B_{p,eff} \right) = 0.95 \times \min\left( \frac{10 \times 0.465^{2} \times 50 \times 4}{4},\; 50 \times 0.75 \times 4 \right) = 102.71\,kip [math]

DCR = 59.162 kip / 102.71 kip = 0.576 < 1.0, OK

Stap 14: Local yielding of the HSS sidewalls

The flange force also reaches the two sidewalls of the tube through the corners. The report checks them with the expression below and φ = 1.0, without citing a clause, so it is the software’s limit for this check:

[math] \phi R_{n} = \phi \times 2 F_{ys}\, t \left[ 5 (1.5 t) + t_{fp} \right] = 1.0 \times 2 \times 50 \times 0.465 \left[ 5 \times (1.5 \times 0.465) + 0.75 \right] = 197.04\,kip [math]

DCR = 59.162 kip / 197.04 kip = 0.300 < 1.0, OK

Shear plate section

The shear plate is a conventional single plate welded to the HSS face and carries the 19 kip reactie. Its checks follow the shear tab procedure, worked in full in Hoe u een afschuifverbinding met één plaat ontwerpt, with the HSS face checks added.

Stap 15: Detailing limits of the shear plate at the beam (AISC 360-16 J3.3, J3.4)

DetailleringslimietBeperken (in)Werkelijk (in)DCRResultaat
Minimale afstand tussen de boutrijen2.6673.0000.889DOORGANG
Maximale afstand tussen de boutrijen6.0003.0000.500DOORGANG
Minimale verticale randafstand plaat1.2501.5000.833DOORGANG
Minimale horizontale randafstand plaat1.3751.5000.917DOORGANG
Minimale horizontale randafstand ligger1.2501.5000.833DOORGANG
Minimale aansluitdiepte7.7509.0000.861DOORGANG
Maximale aansluitdiepte16.0009.0000.563DOORGANG

[math] DCR = \frac{1.375\,in}{1.5\,in} = 0.917 [math]

DCR = 0.917 < 1.0, OK

Stap 16: Shear plate bolt group (AISC 360-16 J3.6)

No fillers, Dus [mathin] h_{f} = 1 [mathin] by J5.2(een). The report uses C = 3 for the three web bolts:

[math] \phi R_{n} = 0.75 \times 68 \times \frac{\pi}{4} (1\,in)^{2} \times (1) \times (3) \times (1) = 120.17\,kip [math]

DCR = 19 kip / 120.17 kip = 0.158 < 1.0, OK

Stap 17: Bearing and tear-out on the shear plate (AISC 360-16 J3.10)

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.375 \times 58 + \min(1.2 \times 1.875, 2.4) \times 0.375 \times 58 \times 2 \right] \times \frac{3}{3} = 91.758\,kip [math]

DCR = 19 kip / 91.758 kip = 0.207 < 1.0, OK

Stap 18: Bearing and tear-out on the beam web (AISC 360-16 J3.10)

[math] \phi R_{n} = (0.75) \times \min(1.2 \times 1.875, 2.4) \times (0.355\,in) \times (65\,ksi) \times (3) = 116.82\,kip [math]

DCR = 19 kip / 116.82 kip = 0.163 < 1.0, OK

Stap 19: Effectieve sterkte van de lijfboutgroep (AISC 360-16 J3.6 Commentaar)

Per bout: schuintrekken 40.055 kip, plate edge bolt 18.352 kip, plate inner bolt 36.703 kip and beam web 38.939 kip. Bouten 1 en 2 take the inner-bolt value and bolt 3 the edge value:

[math] \Sigma \phi r_{eff} = 2 \times (36.703\,kip) + 18.352\,kip = 91.758\,kip, \qquad \phi R_{n,eff} = 91.758 \times \frac{3}{3} = 91.758\,kip [math]

DCR = 19 kip / 91.758 kip = 0.207 < 1.0, OK

Stap 20: Block shear of the shear plate (AISC 360-16 J4.3)

[math] A_{nt} = 0.30469\,in^{2}, \quad A_{gv} = 2.8125\,in^{2}, \quad A_{nv} = 1.6992\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 58 \times 1.6992 + 58 \times 0.30469 \le 0.6 \times 36 \times 2.8125 + 58 \times 0.30469 \right) = 57.604\,kip [math]

DCR = 19 kip / 57.604 kip = 0.330 < 1.0, OK

Stap 21: Shear yielding and rupture of the shear plate (AISC 360-16 J4.2)

[math] \phi R_{n\_sy} = 1.0 \times 0.6 \times 36 \times 3.375 = 72.9\,kip, \qquad \phi R_{n\_sr} = 0.75 \times 0.6 \times 58 \times 2.0391 = 53.22\,kip [math]

DCR = 19 kip / 53.22 kip = 0.357 < 1.0, OK

Stap 22: Detailing limits of the shear plate at the HSS wall

De waarden voor werkbaar vlak en slankheid zijn de grenzen van de module voor een enkele plaat op een HSS-wand.

DetailleringslimietBeperken (in)Werkelijk (in)DCRResultaat
Maximale hoeklasgrootte per liggerspeling0.5000.1880.376DOORGANG
Maximale hoeklasgrootte per HSS-werkbaar vlak0.8850.1880.212DOORGANG
Maximale HSS-wandslankheid b/t33.7165.6020.166DOORGANG

DCR = 0.376 < 1.0, OK

Stap 23: Weld from the shear plate to the HSS wall (AISC 360-16 J2.4)

[math] D_{max} = \frac{(0.1875)(58) \le (0.465)(62)}{3.09} = 3.5194, \qquad L_{w} = 2 \left[ 9 – 2 \times 0.1875 \right] = 17.25\,in [math]

[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.1875, \frac{3.5194}{16}\right) \times \left[ 1 + 0.5 \sin^{1.5}(0) \right] \times 17.25 = 72.042\,kip [math]

DCR = 19 kip / 72.042 kip = 0.264 < 1.0, OK

Stap 24: HSS-muurponsen (AISC handmatige vergelijking. 10-7b, pagina 10-153)

[math] \phi R_{n} = \frac{0.75 \times 62 \times 0.465 \times 9^{2}}{5 \times 2} = 175.14\,kip [math]

DCR = 19 kip / 175.14 kip = 0.108 < 1.0, OK

Samenvatting van ontwerpcontroles

OntwerpcontroleVraag naarCapaciteitDCRResultaat
Verticale afschuiving van dode belasting: detailing at beam3.625 in maat3.625 binnen min1.000DOORGANG
Flange bolts in slip59.162 kip62.701 kip0.944DOORGANG
Lager op flensplaat59.162 kip230.34 kip0.257DOORGANG
Lager op balkflens59.162 kip187.57 kip0.315DOORGANG
Blokschaar, flens plaat59.162 kip168.19 kip0.352DOORGANG
Blokschaar, balk flens59.162 kip165.34 kip0.358DOORGANG
Flensplaatspanning59.162 kip141.68 kip0.418DOORGANG
Beam flange tension rupture59.162 kip82.726 kip0.715DOORGANG
Beam flexural rupture at holes59.162 kip204.13 kip0.290DOORGANG
Flensplaatcompressie59.162 kip219.38 kip0.270DOORGANG
Verticale afschuiving van dode belasting: detailing at HSS face0.5 bij het lassen0.5 maximaal1.000DOORGANG
Flange plate weld to HSS59.162 kip63.144 kip0.937DOORGANG
Flange plate local yielding59.162 kip102.71 kip0.576DOORGANG
HSS sidewall local yielding59.162 kip197.04 kip0.300DOORGANG
Shear plate: detailing at beam1.375 binnen min1.5 in edge0.917DOORGANG
Shear plate bolt group19 kip120.17 kip0.158DOORGANG
Bearing on shear plate19 kip91.758 kip0.207DOORGANG
Lager op balklijf19 kip116.82 kip0.163DOORGANG
Effective web bolt group strength19 kip91.758 kip0.207DOORGANG
Blokschaar, shear plate19 kip57.604 kip0.330DOORGANG
Afschuiving meegeven en scheuren, shear plate19 kip53.22 kip0.357DOORGANG
Shear plate: detailing at HSS wall0.188 bij het lassen0.5 maximaal0.376DOORGANG
Shear plate weld to HSS19 kip72.042 kip0.264DOORGANG
HSS-muurponsen19 kip175.14 kip0.108DOORGANG

De verbinding doorstaat elke controle. The two ratios at 1.000 are detailing limits that the layout meets exactly. Van de krachtcontroles, the flange bolts in slip govern at 0.944, followed closely by the flange plate weld to the HSS face at 0.937. The weld is limited by the HSS: enkel en alleen 2.883 in van de 6.5 in plate counts as effective width, and the weld length is capped at the 2.875 in workable flat of the 4 in face.

Wat u moet wijzigen als een controle mislukt

  • Flange bolts in slip: add bolts along the beam, gebruik een grotere bout, or a Class B faying surface. A deeper beam lowers the flange force for the same moment.
  • Flange plate weld to the HSS: a thicker HSS wall raises Be, since Be grows with the square of the wall thickness, and a wider tube face gives a longer workable flat. A thicker flange plate lowers Be, so do not thicken the plate to fix this check.
  • Flange plate local yielding or HSS sidewall yielding: use a thicker-walled tube.
  • Beam flange tension rupture or flexural rupture: reduce the holes in the flange or use a heavier beam.
  • Block shear or plate tension: increase the edge distances, the bolt spacing or the plate thickness.
  • Shear plate checks: as for a shear tab, add a bolt row or make the plate deeper.

Auto Design is available for the flange plate moment connection to an HSS column. Het verandert de bouten, plates and welds until every check passes, en houdt uw leden en ladingen zoals ingevoerd. Zie de Automatisch ontwerp pagina voor de voorkeuren waarmee het werkt.

Veelgestelde vragen

How is this different from a flange plate connection to a W-shape column?

The beam side checks, Stappen 1 naar 10, are the same as in Hoe een flensplaatmomentverbinding te ontwerpen. The difference is at the column. On a W-shape column the plates weld to a thick flange backed by the column web. An HSS face is a thin wall between the corners, so the flange plate is reduced to an effective width for the weld and for plate local yielding, and the tube sidewalls are checked for local yielding.

Waarom is de 6.5 in flange plate wider than the 4 in HSS face?

The plate is sized to bolt to the 7.5 in beam flange at a 3.625 in maat, which needs more width than the tube face has. The report allows a plate wider than the face, but only the 4 in over the face counts when the force goes into the HSS.

What is the effective width Be?

Eq. K1-1 reduces a plate welded across an HSS face to the width that is effective in carrying load into the wall. It depends on the wall slenderness b/t and on the ratio of wall to plate strength and thickness. Here Be = 2.883 in van de 4 in effective plate width.

Why is the flange force 59.162 kip?

 De  38 kip-ft moment is divided by the distance between flange centers, 17.43 in, geven 26.162 kip, and half of the 66 kip axial force is added to each flange. The report uses this one flange force for every check in the flange plate section.

Does this example follow the AISC 15th or 16th edition Manual?

Het volgt AISC 360-16 with the AISC Manual 15th Edition and AISC Design Guide 24 for the HSS plate local yielding factor. Clause and page references move in the 16th Edition Manual and AISC 360-22, vergelijk ze dus met de editie die uw project gebruikt.

Design a flange plate moment connection to an HSS column for free

Elk getal op deze pagina komt uit één oplossing. Pick the flange plate moment connection to an HSS column, kom je straal binnen, buis, borden, bouten en lasten, en bekijk elk van deze controles in uw browser. Er valt niets te installeren.

De SkyCiv Connection Design-module is de verbindingsontwerpsoftware achter dit voorbeeld. Het geeft u het volledige rekenrapport met elke vergelijking en uw getallen erin, zoals de bovenstaande stappen, plus elke capaciteit en DCR, voor AISC 360-22 en AISC 360-16 (LRFD en ASS) en AS 4100:2020.  De  bout rekenmachine en las rekenmachine dekken zelf de boutgroep en lascontroles af.

Referenties

Harold Munalem, Productmanager voor SkyCiv-verbindingsontwerp

Harold Munalem
Productmanager, Verbindingsontwerp
10+ jaar in het ontwerpen van stalen verbindingen
LinkedIn

Hoe kunnen we u helpen?

×

Ga naar boven