To design a directly welded web connection between two channels to AISC 360, you check the fillet welds that join the beam web to the girder web against the beam end reaction. There is no plate and there are no bolts, so the design comes down to two things: a weld group that fits on the flat of the beam web and is at least the minimum size, and a weld that is strong enough once the base metal on both sides of it is accounted for.

Op deze pagina wordt van begin tot eind één voorbeeld uitgewerkt: a C10x20 beam framing into the back of a C15x50 girder channel, met een 25 kip LRFD reaction carried by 1/4 in E70XX fillet welds on both sides of the beam web, ontworpen voor AISC 360-16 en de AISC-handleiding 15e editie. Elke vergelijking wordt uitgeschreven met zijn cijfers, in dezelfde volgorde als het AISC-berekeningsblad SkyCiv Connection Design module daarvoor produceert.

What is a channel to channel directly welded web connection?

It is a shear connection in which the end of a channel beam is welded straight to a channel girder, with no connecting element in between. The beam web butts against the girder and a fillet weld runs down each side of the beam web. It suits shop-assembled frames, platforms and secondary framing where channels are used for both members and a bolted field joint is not needed.

In dit voorbeeld wordt de BBC-oriëntatie gebruikt, straal naar de achterkant van het kanaal. The beam frames to the flat back of the girder’s web, aan de kant weg van de flenzen, so the beam needs no cope to clear them. De andere oriëntatie, BFC (straal naar de voorkant van het kanaal), plaatst de balk tussen de flenzen van de ligger.

Elevation of a C10x20 beam welded to the back of a C15x50 channel with 1/4 in E70XX fillet welds on both sides

Hoogte uit het berekeningsrapport: C10x20 beam welded to the back of a C15x50 girder channel

3D view of a C10x20 channel beam directly welded to the web of a C15x50 channel girder

3D-weergave van de verbinding in SkyCiv Connection Design

Direct gelast webverbindingsontwerp: de stappen in één oogopslag

  1. Detailleringsgrenzen: check the minimum fillet weld size and that the welded depth fits on the flat of the beam web.
  2. Lassterkte: find the largest weld the base metal can develop, the effective weld length, and the design strength of the two fillet welds.

Ontwerp invoer voor dit voorbeeld

ItemSymboolWaarde
Vereiste schuifsterkte (LRFD)[mathin] V_{u} [mathin]25 kip
BeamC10x20, ASTM A36
Straal diepte / dikte van het web[mathin] d_{bm},\ t_{wb} [mathin]10 in / 0.379 in
Breedte balkflens / dikte[mathin] b_{fb},\ t_{fb} [mathin]2.74 in / 0.436 in
Straalgebied[mathin] A_{bm} [mathin]10 in²
Balkopbrengst / trekspanning[mathin] F_{yb},\ F_{ub} [mathin]36 KSI / 58 KSI
BalkC15x50, ASTM A36
Balk diepte / dikte van het web[mathin] d_{sup},\ t_{ws} [mathin]15 in / 0.716 in
Breedte liggerflens / dikte[mathin] b_{fs},\ t_{fs} [mathin]3.72 in / 0.65 in
Balk gebied[mathin] A_{sup} [mathin]14.7 in²
Balkopbrengst / trekspanning[mathin] F_{ys},\ F_{us} [mathin]36 KSI / 58 KSI
Elasticiteitsmodulus[mathin] E [mathin]29000 KSI
LassenSymboolWaarde
ElektrodeE70XX
Filler metal classification strength[mathin] F_{EXX} [mathin]70 KSI
Fillet weld size, both sides of the beam web[mathin] W [mathin]1/4 in (0.25 in)
Welded depth[mathin] L_{d} [mathin]8 in

Stap 1: Beperkingen voor verbindingsdetails (AISC 360-16 J2.2b)

The weld has to stay on the flat part of the beam web, clear of the flange-to-web fillets. The program takes the web lost at each flange as the larger of the design k distance and the cope depth. This beam has no copes, so each is 1 in.

[math] D_{max} = d_{det\_bm} – c_{t} – c_{b} = (10\ \text{in}) – (1\ \text{in}) – (1\ \text{in}) = 8\ \text{in} [math]

The welded depth of 8 in uses the full flat depth. The minimum fillet weld size of 3/16 in is the AISC 360-16 Table J2.4 value for the thinner part joined, de 0.379 in balkenweb.  De  4 in minimum connection depth is the software’s limit.

DetailleringslimietBeperken (in)Werkelijk (in)DCRResultaat
Minimale hoeklasgrootte0.1880.2500.750DOORGANG
Minimale aansluitdiepte4.0008.0000.500DOORGANG
Maximale aansluitdiepte8.0008.0001.000DOORGANG

DCR = 8 / 8 = 1.000 ≤ 1.0, OK

Stap 2: Design capacity of the weld (AISC 360-16 J2.4)

Basismetaallimiet voor lasgrootte (AISC handmatige vergelijking. 9-2)

A fillet weld can be no stronger than the metal it is fused to. On the girder side the weld sits on the 0.716 in liggerweb. On the beam side the beam web carries a weld on each face, so each weld gets half of the 0.379 op internet, 0.1895 in. The smaller of the two products governs, expressed as a weld size in sixteenths of an inch:

[math] D_{max} = \frac{\min\left(t_{ws} F_{us},\ \frac{t_{wb}}{2} F_{ub}\right)}{3.09\ \text{kip/in} \times F_{EXX}/F_{E70XX}} = \frac{\min\left((0.716\ \text{in})(58\ \text{ksi}),\ (0.1895\ \text{in})(58\ \text{ksi})\right)}{(3.09\ \text{kip/in}) \times (1)} = 3.557 [math]

The beam web governs. A weld of 3.557 sixteenths is [mathin] 3.557/16 = 0.222 [mathin] in, which is smaller than the 1/4 bij het lassen, so the strength equation below uses the 0.222 in size the beam web can develop.

Effectieve laslengte (AISC-handleiding onderdeel 10)

Each of the two welds runs the 8 in welded depth, less two weld sizes for the ends:

[math] L_{w} = 2 \left[ L_{d} – 2W \right] = 2 \times \left[ (8\ \text{in}) – 2 \times (0.25\ \text{in}) \right] = 15\ \text{in} [math]

Lassterkte (Eq. J2-4)

Met [mathin] \phi = 0.75 [mathin] and the load parallel to the welds ([mathin] \theta_{u} = 0 [mathin]):

[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left(W,\ \frac{D_{max}}{16}\right) \left[1 + 0.5 \left(\sin \theta_{u}\right)^{1.5}\right] L_{w} [math]

[math] \phi R_{n} = (0.75) \times 0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left(0.25\ \text{in},\ \frac{3.557}{16}\right) \times \left[1 + 0.5 \times (\sin 0)^{1.5}\right] \times (15\ \text{in}) = 74.275\ \text{kip} [math]

[math] V_{u} = 25\ \text{kip} \le \phi R_{n} = 74.275\ \text{kip} [math]

DCR = 25 kip / 74.275 kip = 0.337 ≤ 1.0, OK

Samenvatting van controles

ControlerenVraag naarCapaciteitDCRResultaat
Beperkingen voor verbindingsdetails8 in8 in1.000DOORGANG
**Design capacity of weld****25 kip****74.275 kip****0.337****DOORGANG**

The connection passes both checks. De detailleringsverhouding van 1.000 is not a strength ratio: it shows that the 8 in weld uses the whole flat of the C10x20 web, which is the most this beam allows. The weld is the governing strength check at 0.337, and its strength is limited by the thin beam web rather than by the 1/4 in weld itself.

Auto Design is available for the channel to channel directly welded web connection. Het verandert de ontwerpvariabelen van de verbinding totdat elke controle slaagt, en houdt uw leden en ladingen zoals ingevoerd. Zie de Automatisch ontwerp pagina voor de voorkeuren waarmee het werkt.

Wat u moet wijzigen als een controle mislukt

  • Maximale aansluitdiepte: the welded depth cannot be more than the flat of the beam web, hier 8 in. If you need more weld, use a deeper beam or a connection with a plate or angles.
  • Minimale hoeklasgrootte: use at least the Table J2.4 minimum for the thinner part joined, hier 3/16 in.
  • Lassterkte: lengthen the weld up to the maximum depth first. A larger weld only helps until it reaches the base metal limit. In this example the beam web already limits the effective size to 0.222 in, dus een 5/16 in weld would add no strength. Past that point, use a beam with a thicker web or a connection with a plate or angles.

Veelgestelde vragen

Why is the effective weld size 0.222 in when the weld is 1/4 in?

AISC handmatige vergelijking. 9-2 limits the weld to what the base metal can develop in shear. Het balkenweb is 0.379 in thick and has a weld on each face, so each weld is matched against half of it. That half-web can only develop a weld of 3.557 zestiende, 0.222 in, and the extra size of the 1/4 in weld is not counted.

Why is the weld length 15 in when the welded depth is 8 in?

There are two welds, één aan elke kant van het balklijf. Each is 8 in long less two weld sizes for the ends, 7.5 in, so the total effective length is 15 in.

Wat betekent BBC?

BBC straalt naar de achterkant van het kanaal. The beam frames to the flat back of the girder channel’s web, weg van de flenzen. Bij BFC, straal naar de voorkant van het kanaal, de balkframes tussen de flenzen van de ligger.

Is the girder web checked?

The girder web enters the design through the base metal check of Step 2, where its 0.716 in thickness is compared with the beam web’s half thickness. In this example the beam web is the weaker of the two, so it sets the weld strength.

Hoe zou dit veranderen voor ASS in plaats van LRFD??

De vergelijkingen zijn hetzelfde. The program uses the ASD safety factor in place of the LRFD resistance factor and compares the result with the ASD required strength.

Ontwerp gratis een direct gelaste webverbinding

Elk getal op deze pagina komt uit één oplossing. Pick the channel to channel category and the directly welded web configuration, kom je straal binnen, balk, lassen en reactie, en bekijk elk van deze controles in uw browser. Er valt niets te installeren.

De SkyCiv Connection Design-module is de verbindingsontwerpsoftware achter dit voorbeeld. Het geeft u het volledige rekenrapport met elke vergelijking en uw getallen erin, zoals de bovenstaande stappen, plus elke capaciteit en DCR, voor AISC 360-22 en AISC 360-16 (LRFD en ASS) en AS 4100:2020.  De  las rekenmachine covers the weld checks on their own.

Referenties

  • AISC 360-16, Specificatie voor constructieve stalen gebouwen: J2.2b (Tabel J2.4), J2.4 (Eq. J2-4).
  • AISC-handleiding voor staalconstructie, 15e editie: Een deel 9, Eq. 9-2; Een deel 10, effectieve laslengte.
  • Ontwerp van staalverbindingen met AISC 360-16
  • Lassen in SkyCiv-verbindingsontwerp
Harold Munalem, Productmanager voor SkyCiv-verbindingsontwerp

Harold Munalem
Productmanager, Verbindingsontwerp
10+ jaar in het ontwerpen van stalen verbindingen
LinkedIn

Hoe kunnen we u helpen?

×

Ga naar boven