Documentazione SkyCiv

La Sua guida al software SkyCiv: tutorial, guide pratiche e articoli tecnici

Capacità del gruppo di saldatura d'angolo (AISC)

A fillet weld group is the set of welds that join one part to another, for example the C-shaped weld around the leg of an angle on a beam web. When the load does not pass through the centroid of the group, the welds also resist a moment, and the strength of the group depends on its shape, the load direction and the eccentricity. AISC 360-16 Section J2.4 gives the strength of fillet welds, and the AISC Manual Part 8 turns it into the instantaneous center of rotation method for weld groups. This article explains how SkyCiv Connection Design applies that method and works it with the numbers from a real double angle connection.

What is the capacity of a fillet weld group?

A single fillet weld is strongest when it is loaded across its length and weakest when it is loaded along it: AISC 360-16 J2.4 increases the strength of a weld element by [mathin] 1.0 + 0.5\sin^{1.5}\theta [mathin], dove [mathin] \theta [mathin] is the angle between the load and the weld axis. A weld group under an eccentric load rotates about a point called the instantaneous center (CIRCUITO INTEGRATO). Each short piece of weld moves at right angles to the line joining it to the IC, by an amount proportional to its distance, and resists with a force that follows the weld’s load and deformation curve. The group’s strength is the load at which the most strained piece reaches its deformation limit.

The weld group check governs where welds carry an eccentric load: angles and plates welded to a beam web, brackets, and welded legs of shear connections. It matters most when the load is large compared with the weld length or acts far from the weld group, and when the load has an axial part, because the direction of the resultant then changes how much each weld piece can carry. The base metal next to the weld can also limit the weld size that is worth using, so the check comes with a base metal limit.

The equations SkyCiv uses

For an eccentric weld group, the AISC Manual Part 8 writes the design strength as:

[math] \phi R_{n} = \phi C C_{1} D l \quad \text{(Manual Eq. 8-21)} [math]

dove:

  • [mathin] \phi = 0.75 [mathin] è il fattore di resistenza (LRFD)
  • [mathin] C [mathin] is the weld group coefficient, in kip/in per sixteenth of an inch of weld size, from the instantaneous center method
  • [mathin] C_{1} [mathin] is the electrode strength coefficient, 1 per E70XX (Tabella manuale 8-3)
  • [mathin] D [mathin] is the weld size in sixteenths of an inch, limitato a [mathin] D_{max} [mathin] for the base metal
  • [mathin] l [mathin] is the length of the vertical weld

SkyCiv finds the IC by iteration. It splits the welds into short segments, works out each segment’s reaction from the Manual’s load and deformation relationship, and moves the IC until the segment reactions balance the applied load. [mathin] C [mathin] is the resulting group strength divided by [mathin] D l [mathin]. The base metal limit on the weld size is:

[math] D_{max} = \frac{\min\left( t_{a} F_{ua},\ d_{ct} F_{ub} \right)}{3.09\ \text{kip/in} \times F_{EXX}/F_{E70XX}} \quad \text{(Manual Eq. 9-2)} [math]

con [mathin] t_{a} [mathin] e [mathin] F_{ua} [mathin] for the angle, e [mathin] d_{ct} [mathin] e [mathin] F_{ub} [mathin] per l'anima della trave.

SkyCiv uses the instantaneous center method for eccentrically loaded weld groups such as the C-shaped angle weld below. Other welds in the software use simpler methods: straight welds loaded directly, such as a directly welded beam web, utilizzare AISC 360-16 Eq. J2-4 with the [mathin] 1.0 + 0.5\sin^{1.5}\theta [mathin] increase, and the welds of a double angle to its support use the elastic method of Manual Part 10, Eq. 10-1un carico.

Esempio lavorato: double angle welded to a beam web

This example is Check 2 del double angle shear and axial connection design example: Due 5/8 in angles, 12 a lungo, welded to the web of a W18x50 beam with 3/16 in E70XX fillet welds on three sides, and bolted to a W14x90 column flange. The connection carries [mathin] V_{u} = 38\ \text{kip} [mathin] shear and 132 kip axial tension or compression. Il problema è stato nuovamente risolto nella versione attuale e i numeri sono gli stessi dell'esempio pubblicato.

Elevation of a W18x50 beam on a W14x90 column with 12 in double angles welded on 3 sides, 38 kip taglio e 132 kip assiale

Elevazione. Each angle is welded to the beam web along its 12 in length and across its top and bottom, a C-shaped weld group on each side of the web.

Load on the welds

The welds carry the resultant of the shear and the axial force:

[math] R_{u} = \sqrt{38^{2} + 132^{2}} = 137.36\ \text{kip} [math]

Base metal limit

Gli angoli sono 0.625 di spessore. The beam web is welded on both faces, so each weld is checked against half the 0.355 nel web, [mathin] d_{ct} = 0.1775\ \text{in} [mathin]. Entrambi lo sono [mathin] F_{u} = 65\ \text{ksi} [mathin]:

[math] D_{max} = \frac{\min\left( 0.625 \times 65,\ 0.1775 \times 65 \right)}{3.09 \times 1} = 3.7338 [math]

Il 3/16 nella saldatura, [mathin] D = 3 [mathin], is below this limit, quindi conta l'intera dimensione della saldatura.

Coefficiente del gruppo di saldatura

Each weld group has a vertical length [mathin] L = 12\ \text{in} [mathin] and horizontal returns [mathin] kL = 2.5\ \text{in} [mathin], with an eccentricity [mathin] e = 2.6324\ \text{in} [mathin]. The report splits the group into 90 segmenti, 30 along the vertical weld and 30 along each return. The iteration puts the IC at:

[math] x_{ic} = -1.2142\ \text{in}, \quad y_{ic} = 13.581\ \text{in} [math]

The segment reactions add up to [mathin] \Sigma r_{ux} = 109.68\ \text{kip} [mathin] e [mathin] \Sigma r_{uy} = 31.57\ \text{kip} [mathin], with a moment about the IC of [mathin] \Sigma M_{ru,ic} = 80.38\ \text{kip-ft} [mathin]. The ratio of the two sums is the same as 38 per 132, so the resultant is mostly along the beam axis, which is the direction of the axial load. Dividing the resultant of the sums by [mathin] D l = 3 \times 12 [mathin]:

[math] C = \frac{\sqrt{109.68^{2} + 31.57^{2}}}{3 \times 12} = 3.17\ \text{kip/in} [math]

Forza progettuale

The two angles give two weld groups, so the length is [mathin] 2L = 24\ \text{in} [mathin]:

[math] \phi R_{n} = \phi C C_{1} D \left( 2L \right) = 0.75 \times 3.17 \times 1 \times 3 \times 24 = 171.18\ \text{kip} [math]

[math] DCR = \frac{R_{u}}{\phi R_{n}} = \frac{137.36}{171.18} = 0.80244 [math]

The weld passes with about 20% to spare. The base metal limit of [mathin] D_{max} = 3.7338 [mathin] means a 1/4 nella saldatura ([mathin] D = 4 [mathin]) would only count as 3.7338 sedicesimi, so the beam web, non la saldatura, would limit a larger weld.

Come lo riporta SkyCiv Connection Design

The weld group appears in the summary of checks as "Design Capacity of Weld at Beam Side" with a demand of 137.361 kip, a capacity of 171.18 kip and a DCR of 0.802435. The row links to the calculation, which shows the base metal limit with the numbers substituted, then a table of the weld segment coordinates, the IC location from the iteration, a table of the reactions of every segment with their sums, the coefficient [mathin] C [mathin], and finally Eq. 8-21 with the numbers in it and the PASS or FAIL result. The segment tables let you check the IC solution by hand.

Cosa cambiare se fallisce

  • Use a longer angle or plate: a longer vertical weld raises [mathin] l [mathin] e, by reducing the relative eccentricity, also raises [mathin] C [mathin].
  • Increase the weld size, but only up to [mathin] D_{max} [mathin]. Past that, the base metal governs and a bigger weld does not add strength.
  • Increase the base metal: a thicker angle, or a beam with a thicker web, raises [mathin] D_{max} [mathin] and lets a larger weld count.
  • Use longer returns if the detail allows: the horizontal welds help resist the moment.
  • Use a stronger electrode only where the base metal is not the limit, da [mathin] D_{max} [mathin] falls as [mathin] F_{EXX} [mathin] rises.

Domande frequenti

Why use the instantaneous center method instead of the elastic method?

The elastic method assumes every part of the weld stays elastic and the most stressed point governs, che è conservatore. The instantaneous center method lets the welds redistribute load as they deform, so the whole group works together and the strength is higher for the same weld. Il Manuale AISC Parte 8 tables for eccentrically loaded weld groups are built on this method.

What does the weld group coefficient C mean?

[mathin] C [mathin] is the strength of the weld group per sixteenth of an inch of weld size per inch of vertical weld length. It already includes the effect of the eccentricity, the load direction and the shape of the group. Multiplying it by [mathin] \phi [mathin], [mathin] C_{1} [mathin], [mathin] D [mathin] e [mathin] l [mathin] gives the design strength. Qui [mathin] C = 3.17\ \text{kip/in} [mathin].

Why is the beam web only half its thickness in the base metal check?

There is a weld on each face of the web, one from each angle, and both pull on the same web. Giving each weld half of the web thickness, 0.1775 nel 0.355 nel web, accounts for the web being shared.

How does axial load change the weld check?

The welds carry the resultant of the shear and the axial force, and the direction of that resultant changes how much each weld segment can carry. In this example the 132 kip axial force is much larger than the 38 kip di taglio, so the resultant of 137.36 kip acts mostly along the beam, and the segment reactions in the report point mostly in that direction.

Check a weld group in your own connection

Choose a welded shear connection in the calcolatore gratuito per la progettazione della connessione, inserisci i tuoi membri, welds and loads, and the weld group is solved by the instantaneous center method for you.

Il modulo SkyCiv Connection Design ti fornisce il rapporto di calcolo completo con ogni equazione e i tuoi numeri in esso, per AISC 360-22 e AISC 360-16 (LRFD e ASD) e AS 4100:2020. Il calcolatore di saldatura covers weld groups on their own, che per il calcolatore di connessione a doppio angolo covers this connection type. The same instantaneous center approach for bolt groups is explained in Calcolo del gruppo di bulloni mediante ICOR.

Riferimenti

  • AISC 360-16, Specifiche per edifici in acciaio strutturale: J2.4 (Eq. J2-4).
  • Manuale AISC per le costruzioni in acciaio, 15th Edizione: Parte 8, eccentrically loaded weld groups (pagine 8-9 per 8-12, Eq. 8-21, Tabella 8-3); Parte 9 Eq. 9-2; Parte 10 Eq. 10-1un carico.
  • Double angle shear and axial connection design example
  • saldature nella progettazione della connessione SkyCiv
Harold Munalem, Responsabile di prodotto per SkyCiv Connection Design

Harold Munalem
Responsabile del prodotto, Connection Design
10+ anni nella progettazione di connessioni in acciaio
LinkedIn

Come possiamo aiutare?

×

Aggiornato novembre 24, 2026

Ha ancora bisogno di aiuto? Ci contatti

Vai all'inizio