When a directly welded web connection carries an axial force as well as the end shear, two things change in the design to AISC 360. The welds now see a resultant force at an angle to their axis, which is larger than the shear alone but also earns the directional strength increase of Eq. J2-5. And the axial force is delivered to the column flange as a concentrated force, so the column has to be checked for flange local bending, web local yielding and, in compressione, web local crippling.
This page works the same connection as the shear-only directly welded web example, a W18x50 beam web welded to the flange of a W14x90 column with 3/16 nelle saldature d'angolo E70XX 15.5 in long on both sides of the web, and adds an axial force of 132 kip in tension or compression to the 38 kip end shear (LRFD). Il design è quello di AISC 360-16 e il Manuale AISC 15a Edizione. Ogni equazione è scritta con i suoi numeri, nello stesso ordine del foglio di calcolo che il SkyCiv Connection Design il modulo produce per questa connessione.
What the axial force adds to a directly welded web connection
A beam in a braced frame or a diaphragm chord often carries an axial force along with its end reaction, for example as a strut or collector. With a directly welded web, that force has no plate or bolts to pass through: it goes straight from the web into the two fillet welds and from them into the column flange.
The member sizes, weld and the checks of the minimum weld size and the beam web in shear are the same as in the shear-only example, and give the same results. This page focuses on the weld under combined load and on the two support checks the axial force adds. The other shear connection types are on the connessioni a taglio ..

Elevazione della connessione di esempio, con il 38 kip taglio e il 132 kip tension or compression at the beam end.

La stessa connessione in SkyCiv Connection Design, con la configurazione Web direttamente saldata nella scheda Assemblaggio.
Directly welded web shear and axial design: i passaggi a colpo d'occhio
- Controllare la dimensione minima della saldatura d'angolo.
- Check the welds for the resultant of the shear and the axial force.
- Controllare l'anima della trave a taglio.
- Check the column for the axial tension: flange local bending and web local yielding.
- Check the column for the axial compression: web local crippling and web local yielding.
Input di progettazione per questo esempio
Il codice di progettazione è AISC 360-16 LRFD. Le proprietà della sezione provengono dal Manuale AISC. La colonna è kdes, utilizzato nella resa locale web, è 1.31 pollici.
| Articolo | Simbolo | Valore |
|---|---|---|
| Taglio fattorizzato | [mathin] V_{u} [mathin] | 38 kip |
| Tensione assiale fattorizzata | [mathin] T_{u} [mathin] | 132 kip |
| Compressione assiale fattorizzata | [mathin] C_{u} [mathin] | 132 kip |
| Beam | W18x50, A992 | |
| Profondità del fascio / spessore del nastro | [mathin] d_{bm},\ t_{wb} [mathin] | 18 pollici / 0.355 pollici |
| Colonna | L14x90, A992 | |
| Profondità della colonna / spessore del nastro | [mathin] d_{sup},\ t_{ws} [mathin] | 14 pollici / 0.44 pollici |
| Larghezza della flangia della colonna / spessore | [mathin] b_{fs},\ t_{fs} [mathin] | 14.5 pollici / 0.71 pollici |
| Colonna kdes | [mathin] k_{des} [mathin] | 1.31 pollici |
| Snervamento di travi e pilastri / sollecitazione di trazione | [mathin] F_{y},\ F_{u} [mathin] | 50 ksi / 65 ksi |
| Modulo di elasticità | [mathin] E [mathin] | 29000 ksi |
| saldare | Filetto E70XX, entrambi i lati della rete | |
| Dimensione della saldatura / length on each side | [mathin] W,\ L_{wv} [mathin] | 0.1875 pollici / 15.5 pollici |
Step 1: Dimensione minima della saldatura d'angolo (AISC 360-16 J2.2b, Tabella J2.4)
The axial force does not change this check. The thinner part joined is the 0.355 nell'anima della trave, so the Table J2.4 minimum is 3/16 pollici, and the weld is 3/16 pollici.
DCR = 0.1875 pollici / 0.1875 in = 1.000 ≤ 1.0, ok
Step 2: Welds under the resultant of shear and axial force (AISC 360-16 J2.4)
The base metal limit and the effective length are the same as for shear alone, half the web thickness against the column flange, and twice the weld size off each end:
[math] D_{max} = \frac{\min\left( t_{fs} F_{us},\ \frac{t_{wb}}{2} F_{ub} \right)}{3.09\ \text{kip/in}} = \frac{\min\left( (0.71\ \text{in})(65\ \text{ksi}),\ (0.1775\ \text{in})(65\ \text{ksi}) \right)}{3.09\ \text{kip/in}} = 3.7338 [math]
[math] L_{w} = 2\left[ L_{wv} – 2W \right] = 2 \times \left[ 15.5\ \text{in} – 2 \times 0.1875\ \text{in} \right] = 30.25\ \text{in} [math]
What changes is the load. The welds now carry the vertical shear along their axis and the axial force across it. The demand is the resultant of the two, at an angle to the weld axis:
[math] R_{u} = \sqrt{V_{u}^{2} + T_{u}^{2}} = \sqrt{(38\ \text{kip})^{2} + (132\ \text{kip})^{2}} = 137.36\ \text{kip} [math]
[math] \theta_{u} = \tan^{-1}\left( \frac{T_{u}}{V_{u}} \right) = \tan^{-1}\left( \frac{132}{38} \right) = 73.94^{\circ} [math]
A fillet weld loaded across its axis is stronger than one loaded along it, ed Eq. J2-5 rewards that with the directional term:
[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left( W,\ \frac{D_{max}}{16} \right) \left[ 1 + 0.5 \left( \sin\theta_{u} \right)^{1.5} \right] L_{w} [math]
[math] \phi R_{n} = (0.75) \times 0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left( 0.1875\ \text{in},\ \frac{3.7338}{16} \right) \times \left[ 1 + 0.5 \left( \sin 73.94^{\circ} \right)^{1.5} \right] \times (30.25\ \text{in}) = 185.84\ \text{kip} [math]
DCR = 137.36 kip / 185.84 kip = 0.739 < 1.0, ok
Questo è il controllo governativo. The same welds are good for 126.33 kip under shear alone, so the load angle adds about 47% to their strength. The demand grows faster, Anche se, a partire dal 38 kip to 137.36 kip, and the ratio rises from 0.301 per 0.739. The tension and compression cases have the same resultant, so one weld check covers both.
Step 3: Anima della trave a taglio (AISC 360-16 J4.2)
The beam web still carries only the 38 kip di taglio, over its full depth:
[math] \phi R_{n} = \phi\, 0.6\, F_{yb}\, d_{bm}\, t_{wb} = (1) \times 0.6 \times (50\ \text{ksi}) \times (18\ \text{in})(0.355\ \text{in}) = 191.7\ \text{kip} [math]
DCR = 38 kip / 191.7 kip = 0.198 < 1.0, ok
Step 4: Colonna sotto la tensione assiale (AISC 360-16 J10.1, J10.2)
The axial tension pulls on the column flange along the line of the weld. AISC 360-16 J10 covers this as a concentrated force on the flange: flessione locale della flangia (J10.1), where it applies, e rendimento web locale (J10.2). Web locale paralizzante (J10.3) is for compressive forces only.
Flessione locale dell'ala
J10.1 does not require a flange local bending check when the length of loading measured across the member flange is less than 0.15 times the flange width:
[math] 0.15\, b_{f} = 0.15\, b_{fs} = 0.15 \times (14.5\ \text{in}) = 2.175\ \text{in} [math]
The load is delivered by the beam web, so the loaded length across the column flange is the web thickness, [mathin] t_{wb} = 0.355\ \text{in} [mathin]. That is less than 2.175 pollici, so flange local bending need not be checked.
Snervamento locale dell'anima
The force spreads through the column flange into the web over the weld length plus [mathin] 5k [mathin] (Eq. J10-2):
[math] \phi R_{n} = \phi\, F_{ys}\, t_{ws} \left( 5 k_{des} + L_{wv} \right) = (1) \times (50\ \text{ksi}) \times (0.44\ \text{in}) \times \left( 5 \times 1.31\ \text{in} + 15.5\ \text{in} \right) = 485.1\ \text{kip} [math]
DCR = 132 kip / 485.1 kip = 0.272 < 1.0, ok
Step 5: Colonna sotto compressione assiale (AISC 360-16 J10.2, J10.3)
In compression the beam pushes on the column flange, so web local crippling joins web local yielding. Web locale paralizzante, Eq. J10-4, with the weld length as the bearing length:
[math] \phi R_{n,wlc} = \phi\, 0.8\, t_{ws}^{2} \left[ 1 + 3\left( \frac{L_{wv}}{d_{sup}} \right) \left( \frac{t_{ws}}{t_{fs}} \right)^{1.5} \right] \sqrt{\frac{E F_{ys} t_{fs}}{t_{ws}}}\, Q_{f} [math]
[math] \phi R_{n,wlc} = (0.75) \times 0.8 \times (0.44\ \text{in})^{2} \left[ 1 + 3\left( \frac{15.5}{14} \right) \left( \frac{0.44}{0.71} \right)^{1.5} \right] \sqrt{\frac{(29000\ \text{ksi})(50\ \text{ksi})(0.71\ \text{in})}{0.44\ \text{in}}} \times (1) = 465.59\ \text{kip} [math]
Web local yielding is the same as in tension, 485.1 kip. The lower of the two governs:
[math] \phi R_{n} = \min\left( 465.59\ \text{kip},\ 485.1\ \text{kip} \right) = 465.59\ \text{kip} [math]
DCR = 132 kip / 465.59 kip = 0.284 < 1.0, ok
Both column checks pass with room to spare, so this W14x90 needs no stiffeners or web doubler for these limit states.
Riepilogo dei controlli
| Verifica della progettazione | Richiesta | Capacità | DCR | Risultato |
|---|---|---|---|---|
| Dimensione minima della saldatura d'angolo | 0.1875 pollici | 0.1875 pollici | 1.000 | Metà dell'altezza del muro dal fondo della base per il caso del |
| Welds under shear and axial force | 137.36 kip | 185.84 kip | 0.739 | Metà dell'altezza del muro dal fondo della base per il caso del |
| Anima della trave a taglio | 38 kip | 191.7 kip | 0.198 | Metà dell'altezza del muro dal fondo della base per il caso del |
| Colonna sotto tensione assiale | 132 kip | 485.1 kip | 0.272 | Metà dell'altezza del muro dal fondo della base per il caso del |
| Colonna sottoposta a compressione assiale | 132 kip | 465.59 kip | 0.284 | Metà dell'altezza del muro dal fondo della base per il caso del |
Every check in this directly welded web shear and axial connection design passes. Il 1.000 il rapporto è la dimensione minima della saldatura d'angolo, quale il 3/16 nella saldatura incontra esattamente. Dei controlli di forza, le saldature governano a 0.739 sotto il 137.36 kip resultant, contro 0.301 for the same welds under shear alone. The column checks for the axial force come next, with web local crippling in compression at 0.284.
Auto Design is available for the directly welded web connection with shear and axial load to a column flange. Modifica le variabili di progettazione della connessione finché ogni controllo non viene superato, e mantiene i tuoi membri e i tuoi carichi come inseriti. Vedi il Progettazione automobilistica pagina per le preferenze a cui funziona.
Cosa cambiare se un controllo fallisce
- Forza della saldatura: lengthen the welds, increase the weld size up to the base metal limit of the half web, oppure utilizzare un elettrodo più potente. Past that limit a larger weld adds no strength.
- Column web local yielding or crippling: a longer weld spreads the force over more of the column web and raises both strengths. Otherwise use a column with a thicker web, or add stiffeners or a web doubler.
- Flessione locale dell'ala: with a directly welded web it only applies if the loaded length across the flange reaches 0.15 times the flange width.
- Minimum weld size or beam web shear: as for shear alone, meet the Table J2.4 minimum, o utilizzare una trave più pesante.
Domande frequenti
Why does the weld get stronger when the axial force is added?
The strength of a fillet weld depends on the direction of the load. Under pure shear the load runs along the weld, and the directional term of Eq. J2-5 lo è 1. Con 132 kip of axial force the resultant turns to 73.94 degrees from the weld axis, and the term rises toward its maximum of 1.5 for a load at 90 gradi. Here it lifts the weld strength from 126.33 kip to 185.84 kip.
Why is only one weld check reported for both tension and compression?
The axial force is 132 salta in ogni caso, so the resultant on the welds is the same 137.36 kip at the same angle. The sign of the axial force matters for the column, which is why the support is checked separately for tension and compression.
Why is flange local bending not checked?
J10.1 only requires it when the force is spread across a meaningful width of the column flange. Here the force comes in through a 0.355 nell'anima della trave, which is much less than 0.15 volte il 14.5 nella larghezza della flangia, 2.175 pollici, so J10.1 does not require the check.
Why is web local crippling checked only in compression?
Web local crippling is the buckling of the column web under a compressive force pushed through the flange. A tensile force pulls the web straight, so J10.3 applies to compressive forces only, while web local yielding applies to both.
Come cambierebbe la situazione per AISC ASD invece che per LRFD?
Gli stati limite e le resistenze nominali sono le stesse. Con AISC ASD confronti le forze a livello di servizio con la forza nominale divisa per un fattore di sicurezza: 0.75 for the welds and for web local crippling becomes a safety factor of 2.00, e 1.00 for web shear yielding and web local yielding becomes 1.50.
Progetta gratuitamente una connessione web saldata direttamente
Ogni numero in questa pagina deriva da una soluzione. Pick the directly welded web configuration with shear and axial load, entra nel tuo raggio, supporto, weld and forces, e il calcolatore gratuito esegue ciascuno di questi controlli nel tuo browser senza nulla da installare.
Il modulo SkyCiv Connection Design è il software di progettazione della connessione dietro questo esempio. Ti fornisce il rapporto di calcolo completo con ogni equazione e i tuoi numeri in esso contenuti, come i passaggi precedenti, più ogni capacità e DCR, per AISC 360-22 e AISC 360-16 (LRFD e ASD) e AS 4100:2020. Il calcolatore di saldatura copre da solo i gruppi di saldatura d'angolo.
Riferimenti
- AISC 360-16, Specifiche per edifici in acciaio strutturale: J2.2b (Tabella J2.4), J2.4 (Eq. J2-4, J2-5), J4.2 (Eq. J4-3), J10.1, J10.2 (Eq. J10-2), J10.3 (Eq. J10-4).
- Manuale AISC per le costruzioni in acciaio, 15th Edizione: Parte 9 (Eq. 9-2), Parte 10 (Efficace lunghezza della saldatura).
- Progettazione di connessioni in acciaio mediante AISC 360-16
- Progettazione automobilistica nella progettazione della connessione SkyCiv
Harold Munalem
Responsabile del prodotto, Connection Design
10+ anni nella progettazione di connessioni in acciaio
LinkedIn