When a beam framing into an HSS column also carries an axial force, for a drag strut, a collector or a braced bay, the single plate has to pass that force into the tube wall as well as the end shear. To AISC 360-16 this adds a set of checks to the shear tab design: bearing and tear-out in the axial direction, block shear under axial load, trazione e compressione della piastra, combined interaction, beam web block shear and beam tension rupture, e, most important, the strength of the HSS wall under a force pulling or pushing straight on it.

This page works through one example: a W18x35 beam into the 6 nella parete di una colonna HSS8x6x1/2, con 32 kip taglio e 93 kip assiale (tensione e compressione) under LRFD, dieci 1 in A490-SC bolts in two columns and a 3/4 in Grade 50 piastra. The shear-only version of this connection is covered in Single Plate to HSS Column Connection Design, so here the shear checks are kept short and the page concentrates on what the axial force adds. Every number comes from the SkyCiv Connection Design calc sheet.

What does the axial force change in a single plate to HSS connection?

A shear tab on its own is a simple connessione a taglio and the HSS wall only sees an eccentric vertical load. An axial force acts at right angles to the wall. In tension it pulls the plate away from the tube and the wall bends like a plate between the corners; in compression it pushes the plate in. Because a tube wall is thin and flexible out of its plane, this is usually where a shear and axial tab on an HSS runs out of strength, long before the bolts or plate do.

The axial force also changes which way the bolts bear. In tension they bear toward the free ends, the end of the plate and the end of the beam; in compression they bear toward the support and the span. The software checks both directions and combines each with the shear. You can run the connection in the calcolatore di connessione a piastra singola.

Elevazione: W18x35 beam on a 3/4 in single plate welded to an HSS8x6x1/2 wall, two columns of five 1 nei bulloni A490-SC

Elevazione della connessione di esempio, with the shear and the axial tension and compression acting at the bolt group.

Sezione A-A attraverso il 3/4 in x 6 1/2 in x 15 in Grade 50 single plate with 1/2 nella E70XX la saldatura d'angolo avviene su entrambi i lati

Sezione A-A. La piastra presenta fori orizzontali ad asola corta e a 1/2 saldatura d'angolo su entrambi i lati.

3D view of the shear and axial single plate connection: W18x35 beam framing into a rectangular HSS8x6x1/2 column

3Vista D della connessione in SkyCiv Connection Design.

I passaggi in breve

The report runs 28 verifiche. The ones in bold are added, or changed, by the axial force:

  1. Detailing limits at the beam.
  2. Bolt group in slip, under the resultant of shear and axial.
  3. Duttilità della piastra.
  4. Bearing and tear-out on the plate, taglio.
  5. Bearing and tear-out on the plate, tensione assiale.
  6. Bearing and tear-out on the plate, compressione assiale.
  7. Shear and axial interaction, cuscinetto della piastra.
  8. Bearing and tear-out on the beam web, taglio.
  9. Bearing and tear-out on the beam web, tensione assiale.
  10. Bearing and tear-out on the beam web, compressione assiale.
  11. Shear and axial interaction, beam web bearing.
  12. Block shear of the plate, taglio.
  13. Block shear of the plate, assiali.
  14. Shear and axial interaction, plate block shear.
  15. Shear yielding and rupture of the plate.
  16. Flessione della piastra.
  17. Plate tension yielding and rupture.
  18. Taglio, tension and flexure interaction, snervamento.
  19. Taglio, tension and flexure interaction, rottura.
  20. Compressione della placca.
  21. Taglio, compression and flexure interaction.
  22. Taglio a blocco dell'anima della trave, assiali.
  23. Rottura della tensione della trave.
  24. Limiti di dettaglio sulla parete HSS.
  25. Saldare per sviluppare la piastra.
  26. Weld to the HSS wall, under the resultant.
  27. Punzonatura per pareti HSS.
  28. HSS wall under the axial force.

Input di progettazione per questo esempio

Il codice di progettazione è AISC 360-16 LRFD. The beam and column are the same as in the shear-only example; i bulloni, plate and weld are larger to carry the axial force. How the loads are entered is explained in carichi e combinazioni di carico.

ArticoloSimboloValore
Taglio fattorizzato[mathin] V_{u} [mathin]32 kip
Tensione assiale fattorizzata[mathin] T_{u} [mathin]93 kip
Compressione assiale fattorizzata[mathin] C_{u} [mathin]93 kip
BeamL18x35, ASTM A992 (d = 17.7 pollici, tw = 0.3 pollici, A = 10.3 pollici², Fy / Fu = 50 / 65 ksi)
ColonnaHSS8x6x1/2, ASTM A500 gr. C (Fy / Fu = 50 / 62 ksi)
HSS wall width / design thickness / workable flat[mathin] b,\ t,\ W_{flat} [mathin]6 pollici / 0.465 pollici / 4.875 pollici
ArticoloSimboloValore
Piatto unicoPL 3/4 x 6 1/2 x 15, ASTM A572 gr. 50 (Fy / Fu = 50 / 65 ksi)
bulloni1 nell'A490-SC, Superficie di facciata in classe A
Bolt shear stress / sollecitazione di trazione[mathin] F_{nv},\ F_{nt} [mathin]68 ksi / 113 ksi
BuchiPiatto: orizzontale a fessura corta (HSSL). Rete del fascio: standard (malattie sessualmente trasmissibili)
Saldare alla parete HSS1/2 a filetto su entrambi i lati, E70XX
Righe di bulloni / spaziatura delle file[mathin] n_{r},\ s_{r} [mathin]5 / 3 pollici
Colonne di bulloni / spaziatura delle colonne[mathin] n_{c},\ s_{c} [mathin]2 / 3 pollici
Weld line to first bolt line[mathin] a [mathin]2 pollici
Edge distances, plate and beam1.5 pollici
Eccentricità progettuale (Tabella manuale 10-9)[mathin] e [mathin]3.5 pollici

Step 1: Limiti di dettaglio sul lato della trave (AISC 360-16 J3.3, J3.4)

The same limits as for the shear-only connection, now for a 1 nel bullone: 2.667 in minimum spacing, 1.25 in minimum edge from Table J3.4, e 1.375 in at the plate’s slotted horizontal edge.

Limite di dettaglioLimite (pollici)Effettivo (pollici)DCRRisultato
Minimum bolt row / spaziatura delle colonne2.6673.0000.889Metà dell'altezza del muro dal fondo della base per il caso del
Maximum bolt row / spaziatura delle colonne6.0003.0000.500Metà dell'altezza del muro dal fondo della base per il caso del
Distanza minima dal bordo verticale della piastra1.2501.5000.833Metà dell'altezza del muro dal fondo della base per il caso del
Distanza minima dal bordo orizzontale della piastra1.3751.5000.917Metà dell'altezza del muro dal fondo della base per il caso del
Distanza minima dal bordo orizzontale della trave1.2501.5000.833Metà dell'altezza del muro dal fondo della base per il caso del
Profondità minima di connessione7.75015.0000.517Metà dell'altezza del muro dal fondo della base per il caso del
Profondità massima di connessione16.00015.0000.938Metà dell'altezza del muro dal fondo della base per il caso del

[math] DCR = \frac{15\,in}{16\,in} = 0.938 [math]

DCR = 0.938 < 1.0, ok

Step 2: Bolt group in slip under shear and axial (AISC 360-16 J3.8)

With slip-critical bolts the group is designed against slip, Eq. J3-4, for the resultant of the shear and the axial force. L'eccentricità è 3.5 in from Manual Table 10-9, and the ICOR coefficient for the inclined load on the 2 x 5 group is C = 8.41 (the IC converges at x = -0.78739 pollici, y = 13.997 pollici).

BulloneR (kip)Trova la distribuzione delle sollecitazioni in una piastra quadrata a causa degli effetti di un foro circolare al centro sotto un carico lineare uniforme nel piano (kip)Ry (kip)Mn (pollo-in)
118.0618.031.01253.19
217.6617.621.26194.75
316.8416.761.65135.35
415.0914.912.3576.35
511.0710.304.0623.76
618.1017.474.73262.47
717.7716.805.79206.67
817.1315.487.33151.58
915.9712.739.65100.15
1014.356.6912.6961.43

[math] R_{u} = \sqrt{V_{u}^{2} + T_{u}^{2}} = \sqrt{32^{2} + 93^{2}} = 98.351\,kip [math]

[math] \phi R_{n} = \phi\, \mu\, D_{u}\, h_{f}\, T_{b}\, N_{s}\, C = (0.85) \times (0.3) \times (1.13) \times (1) \times (64\,kip) \times (1) \times (8.41) = 155.09\,kip [math]

DCR = 98.351 kip / 155.09 kip = 0.634 < 1.0, ok

Step 3: Duttilità della piastra (Pagina Manuale AISC 10-89)

Unlike the shear-only example, this layout does need the check. The moment coefficient of the group is C’ = 38.669 pollici:

[math] M_{max} = \frac{F_{nv}}{0.9}\, \frac{\pi}{4} d_{b}^{2}\, C’ = \frac{68\,ksi}{0.9} \times \frac{\pi}{4} (1\,in)^{2} \times (38.669\,in) = 191.22\,kip\text{-}ft [math]

[math] t_{max} = \frac{6 M_{max}}{F_{yp} d_{p}^{2}} = \frac{6 \times (191.22\,kip\text{-}ft)}{(50\,ksi) \times (15\,in)^{2}} = 1.2238\,in [math]

DCR = 0.75 pollici / 1.2238 in = 0.613 < 1.0, ok

Step 4: Plate bearing and tear-out under shear (AISC 360-16 J3.10)

As in the shear-only example, con [mathin] d_{h} = 1.125\,in [mathin], an edge clear distance of 0.9375 dentro e 1.875 in between bolts, scaled by C over the five bolts in a line:

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.75 \times 65 + \min(1.2 \times 1.875, 2.4) \times 0.75 \times 65 \times 4 \right] \times \frac{8.41}{5} = 622.67\,kip [math]

DCR = 32 kip / 622.67 kip = 0.051 < 1.0, ok

Step 5: Plate bearing and tear-out under axial tension (AISC 360-16 J3.10)

Under tension the bolts bear on the plate toward its free end. The hole dimension along the slot is [mathin] d_{h} = 1.3125\,in [mathin], quindi le distanze chiare sono:

[math] l_{c1} = L_{eh\_pl} – \frac{d_{h}}{2} = 1.5 – 0.65625 = 0.84375\,in, \qquad l_{c2} = s_{c} – d_{h} = 1.6875\,in [math]

Along the axial direction there are two bolts in each row, the outer one at the edge and the inner one behind it. The sum is scaled by C over the two bolt columns:

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.84375, 2.4) \times 0.75 \times 65 + \min(1.2 \times 1.6875, 2.4) \times 0.75 \times 65 \times (2 – 1) \right] \times \frac{8.41}{2} = 467\,kip [math]

DCR = 93 kip / 467 kip = 0.199 < 1.0, ok

Step 6: Plate bearing and tear-out under axial compression (AISC 360-16 J3.10)

Under compression the bolts bear on the plate toward the support. The edge distance for the bolt nearest the wall is the 2 nella distanza saldatura-bullone:

[math] l_{c1} = a – \frac{d_{h}}{2} = 2 – 0.65625 = 1.3438\,in, \qquad l_{c2} = 1.6875\,in [math]

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 1.3438, 2.4) \times 0.75 \times 65 + \min(1.2 \times 1.6875, 2.4) \times 0.75 \times 65 \times (2 – 1) \right] \times \frac{8.41}{2} = 559.25\,kip [math]

DCR = 93 kip / 559.25 kip = 0.166 < 1.0, ok

Step 7: Shear and axial interaction of plate bearing

The axial direction with the larger ratio of load to bearing strength is used, here tension:

[math] \left( \frac{V_{u}}{\phi R_{n,V}} \right)^{2} + \left( \frac{T_{u}}{\phi R_{n,T}} \right)^{2} = \left( \frac{32}{622.67} \right)^{2} + \left( \frac{93}{467} \right)^{2} = 0.042299 [math]

DCR = 0.042 < 1.0, ok

Step 8: Beam web bearing and tear-out under shear (AISC 360-16 J3.10)

[math] \phi R_{n} = (0.75) \times \min(1.2 \times 1.875, 2.4) \times (0.3\,in) \times (65\,ksi) \times (8.41) = 276.74\,kip [math]

DCR = 32 kip / 276.74 kip = 0.116 < 1.0, ok

Step 9: Beam web bearing and tear-out under axial tension (AISC 360-16 J3.10)

Under tension the bolts bear on the beam web toward the end of the beam, so the edge bolt uses the 1.5 in beam horizontal edge distance:

[math] l_{c1} = 1.5 – \frac{1.125}{2} = 0.9375\,in, \qquad l_{c2} = 3 – 1.125 = 1.875\,in [math]

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.3 \times 65 + \min(1.2 \times 1.875, 2.4) \times 0.3 \times 65 \times (2 – 1) \right] \times \frac{8.41}{2} = 207.56\,kip [math]

DCR = 93 kip / 207.56 kip = 0.448 < 1.0, ok

Step 10: Beam web bearing and tear-out under axial compression (AISC 360-16 J3.10)

Under compression the bolts bear toward the span, dove la rete è continua. Il fulmine più lontano non ha alcun bordo oltre, so it takes full bearing, 2.4 d t Fu:

[math] \phi R_{n} = (0.75) \left[ 2.4 \times 1 \times 0.3 \times 65 + \min(1.2 \times 1.875, 2.4) \times 0.3 \times 65 \times (2 – 1) \right] \times \frac{8.41}{2} = 285.97\,kip [math]

DCR = 93 kip / 285.97 kip = 0.325 < 1.0, ok

Step 11: Shear and axial interaction of beam web bearing

Tension governs again:

[math] \left( \frac{32}{276.74} \right)^{2} + \left( \frac{93}{207.56} \right)^{2} = 0.21414 [math]

DCR = 0.214 < 1.0, ok

Step 12: Plate block shear under shear (AISC 360-16 J4.3)

The block runs down the two bolt lines and out to the free edge. The report takes [mathin] U_{bs} = 0.5 [mathin] for this two-column layout:

[math] A_{nt} = 1.8281\,in^{2}, \quad A_{gv} = 10.125\,in^{2}, \quad A_{nv} = 6.1172\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 6.1172 + 0.5 \times 65 \times 1.8281 \le 0.6 \times 50 \times 10.125 + 0.5 \times 65 \times 1.8281 \right) = 223.49\,kip [math]

DCR = 32 kip / 223.49 kip = 0.143 < 1.0, ok

Step 13: Plate block shear under axial load (AISC 360-16 J4.3)

Under the axial force the block tears out in the other direction: tension across the bolt rows to one plate edge, and shear along the outer bolt row to the plate end.

[math] A_{nt} = 0.75 \left[ (5 – 1) \times 3 + 1.5 – 4.5 \times (1.1875) \right] = 6.1172\,in^{2} [math]

[math] A_{gv} = 0.75 \left[ 1.5 + (2 – 1) \times 3 \right] = 3.375\,in^{2} [math]

[math] A_{nv} = 0.75 \left[ 6.5 – 2 – 1.5 \times (1.3125 + 0.0625) \right] = 1.8281\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 1.8281 + 65 \times 6.1172 \le 0.6 \times 50 \times 3.375 + 65 \times 6.1172 \right) = 351.69\,kip [math]

DCR = 93 kip / 351.69 kip = 0.264 < 1.0, ok

Step 14: Shear and axial interaction of plate block shear

[math] \left( \frac{32}{223.49} \right)^{2} + \left( \frac{93}{351.69} \right)^{2} = 0.090431 [math]

DCR = 0.090 < 1.0, ok

Step 15: Plate shear yielding and rupture (AISC 360-16 J4.2)

[math] \phi R_{n\_sy} = 1.0 \times 0.6 \times 50 \times 11.25 = 337.5\,kip, \qquad \phi R_{n\_sr} = 0.75 \times 0.6 \times 65 \times 6.7969 = 198.81\,kip [math]

DCR = 32 kip / 198.81 kip = 0.161 < 1.0, ok

Step 16: Flessione della placca utilizzando la procedura della trave a doppia copiglia (AISC 360-16 F11.2)

The same procedure as the shear-only example, sopra il 2 dalla saldatura alla linea dei bulloni. With Lb d / t² = 53.333, fra 46.4 e 1102, Eq. F11-2 applies and the plate reaches its plastic moment:

[math] \phi M_{n} = 0.9 \times \min\left[ C_{b} \left( 1.52 – 0.274 \times 53.333 \times \frac{50}{29000} \right) \times 50 \times 28.125,\; 50 \times 42.188 \right] = 158.2\,kip\text{-}ft \;\Rightarrow\; \phi V_{n} = 949.22\,kip [math]

[math] Z_{net} = 25.892\,in^{3}, \qquad \phi M_{n} = 0.75 \times 65 \times 25.892 = 105.19\,kip\text{-}ft \;\Rightarrow\; \phi V_{n} = 631.11\,kip [math]

DCR = 32 kip / 631.11 kip = 0.051 < 1.0, ok

Step 17: Plate tension yielding and rupture (AISC 360-16 J4.1)

The plate is a tension member for the axial force, checked on its full 15 in profondità:

[math] \phi R_{n\_ty} = 0.9 \times F_{yp}\, t_{p}\, d_{p} = 0.9 \times 50 \times 0.75 \times 15 = 506.25\,kip [math]

[math] \phi R_{n\_tr} = 0.75 \times F_{up}\, t_{p} \left[ d_{p} – n_{r} (d_{h} + 0.0625) \right] = 0.75 \times 65 \times 0.75 \left[ 15 – 5 \times (1.1875) \right] = 331.35\,kip [math]

DCR = 93 kip / 331.35 kip = 0.281 < 1.0, ok

Step 18: Taglio, tension and flexure interaction, snervamento (Manuale AISC Parte 10)

[math] \left( \frac{T_{u}}{2 \phi R_{n\_ty}} + \frac{V_{u}}{\phi V_{n}} \right)^{2} + \left( \frac{V_{u}}{\phi R_{n\_sy}} \right)^{2} = \left( \frac{93}{2 \times 506.25} + \frac{32}{949.22} \right)^{2} + \left( \frac{32}{337.5} \right)^{2} = 0.024756 [math]

DCR = 0.025 < 1.0, ok

Step 19: Taglio, tension and flexure interaction, rottura (Manuale AISC Parte 10)

[math] \left( \frac{T_{u}}{\phi R_{n\_tr}} + \frac{8 V_{u}}{9 \phi V_{n}} \right)^{2} + \left( \frac{V_{u}}{\phi R_{n\_sr}} \right)^{2} = \left( \frac{93}{331.35} + \frac{8 \times 32}{9 \times 631.11} \right)^{2} + \left( \frac{32}{198.81} \right)^{2} = 0.13202 [math]

DCR = 0.132 < 1.0, ok

Step 20: Compressione della placca (AISC 360-16 J4.4)

KL/r of the plate is no more than 25, quindi l'Eq. J4-6 applies with no buckling reduction:

[math] \phi R_{n} = 0.9\, F_{yp}\, t_{p}\, d_{p} = 0.9 \times 50 \times 0.75 \times 15 = 506.25\,kip [math]

DCR = 93 kip / 506.25 kip = 0.184 < 1.0, ok

Step 21: Taglio, compression and flexure interaction (Manuale AISC Parte 10)

[math] \left( \frac{C_{u}}{2 \phi R_{n}} + \frac{V_{u}}{\phi V_{n}} \right)^{2} + \left( \frac{V_{u}}{\phi R_{n\_sy}} \right)^{2} = \left( \frac{93}{2 \times 506.25} + \frac{32}{949.22} \right)^{2} + \left( \frac{32}{337.5} \right)^{2} = 0.024756 [math]

DCR = 0.025 < 1.0, ok

Step 22: Beam web block shear under axial load (AISC 360-16 J4.3)

The tension force can also tear a block out of the beam web: tension across the five bolt rows and shear along the top and bottom rows to the beam end.

[math] A_{nt} = 0.3 \left[ (5 – 1) \times 3 – (5 – 1) \times (1.1875) \right] = 2.175\,in^{2} [math]

[math] A_{gv} = 2 \times 0.3 \left[ 1.5 + 3 \right] = 2.7\,in^{2}, \qquad A_{nv} = 2 \times 0.3 \left[ 3 + 1.5 – 1.5 \times (1.1875) \right] = 1.6313\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 1.6313 + 65 \times 2.175 \le 0.6 \times 50 \times 2.7 + 65 \times 2.175 \right) = 153.75\,kip [math]

DCR = 93 kip / 153.75 kip = 0.605 < 1.0, ok

Step 23: Rottura della tensione della trave (AISC 360-16 D3, J4.1)

Solo la rete è imbullonata, so shear lag reduces the effective net area of the beam. The report uses U = 0.73655 from Table D3.1 case 2:

[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.73655 \left[ 10.3 – 5 \times (1.125 + 0.0625) \times 0.3 \right] = 305.88\,kip [math]

DCR = 93 kip / 305.88 kip = 0.304 < 1.0, ok

Step 24: Limiti di dettaglio sulla parete HSS

The weld-on-flat and slenderness values are the module’s limits for a single plate on an HSS wall.

Limite di dettaglioLimite (pollici)Effettivo (pollici)DCRRisultato
Dimensione massima della saldatura d'angolo per spazio trave0.5000.5001.000Metà dell'altezza del muro dal fondo della base per il caso del
Dimensione massima della saldatura d'angolo per piano lavorabile in HSS1.5380.5000.325Metà dell'altezza del muro dal fondo della base per il caso del
Massima snellezza della parete HSS b/t33.7169.9030.294Metà dell'altezza del muro dal fondo della base per il caso del

Il 1/2 in weld exactly fills the 1/2 nella distanza del raggio, che è consentito:

[math] DCR = \frac{0.5\,in}{0.5\,in} = 1.000 [math]

DCR = 1.000, ok

Step 25: Saldatura necessaria per sviluppare la piastra unica (Pagina Manuale AISC 10-87)

[math] W_{duc} = \frac{5}{8} \times (0.75\,in) = 0.46875\,in [math]

DCR = 0.46875 pollici / 0.5 in = 0.938 < 1.0, ok

Step 26: Fillet weld strength to the HSS wall under the resultant (AISC 360-16 J2.4)

The weld now carries the resultant of the shear and the axial force, at an angle to its axis. That angle earns the directional strength increase of Eq. J2-5, which a pure shear load on a vertical weld does not get:

[math] \theta = 71.012^{\circ}, \qquad D_{max} = \frac{(0.375)(65) \le (0.465)(62)}{3.09} = 7.8883, \qquad L_{w} = 2 \left[ 15 – 2 \times 0.5 \right] = 28\,in [math]

[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.5, \frac{7.8883}{16}\right) \times \left[ 1 + 0.5 \sin^{1.5}(71.012) \right] \times 28 = 448.85\,kip [math]

DCR = 98.351 kip / 448.85 kip = 0.219 < 1.0, ok

Step 27: Punzonatura per pareti HSS (AISC Manuale Eq. 10-7b, . 10-153)

[math] \phi R_{n} = \frac{0.75 \times 62 \times 0.465 \times 15^{2}}{5 \times 3.5} = 278\,kip [math]

DCR = 32 kip / 278 kip = 0.115 < 1.0, ok

Step 28: HSS wall under the axial force

This is the check the axial force exists for. The plate pulls (or pushes) on the middle of the tube wall, and the wall resists by forming a yield line pattern across its workable flat. The report uses the yield line expression it attributes to R. Kapp, which is the software’s method for this limit state:

[math] \phi R_{n} = 0.75 \left[ \frac{F_{ys}\, t^{2}\, d_{p}}{0.5 (W_{flat} – t_{p})} + 4 F_{ys}\, t^{2} \sqrt{1 + \frac{t_{p}}{W_{flat} – t_{p}}} \right] [math]

[math] \phi R_{n} = 0.75 \left[ \frac{50 \times 0.465^{2} \times 15}{0.5 \times (4.875 – 0.75)} + 4 \times 50 \times 0.465^{2} \times \sqrt{1 + \frac{0.75}{4.875 – 0.75}} \right] = 94.23\,kip [math]

DCR = 93 kip / 94.23 kip = 0.987 < 1.0, ok

The first term grows with the plate depth and falls as the workable flat gets wider, and both terms grow with the square of the wall thickness. That is why the wall, not the bolts or the plate, sets the axial capacity of this connection.

Riepilogo delle verifiche di progettazione

Verifica della progettazioneRichiestaCapacitàDCRRisultato
Dettagli sul lato della trave15 in profondità16 al massimo0.938Metà dell'altezza del muro dal fondo della base per il caso del
Bolt group in slip (risultante)98.351 kip155.09 kip0.634Metà dell'altezza del muro dal fondo della base per il caso del
Duttilità della piastra0.75 pollici1.2238 pollici0.613Metà dell'altezza del muro dal fondo della base per il caso del
Cuscinetto a piastra, taglio32 kip622.67 kip0.051Metà dell'altezza del muro dal fondo della base per il caso del
Cuscinetto a piastra, tensione assiale93 kip467 kip0.199Metà dell'altezza del muro dal fondo della base per il caso del
Cuscinetto a piastra, compressione assiale93 kip559.25 kip0.166Metà dell'altezza del muro dal fondo della base per il caso del
Plate bearing interaction0.042Metà dell'altezza del muro dal fondo della base per il caso del
Cuscinetto dell'anima della trave, taglio32 kip276.74 kip0.116Metà dell'altezza del muro dal fondo della base per il caso del
Cuscinetto dell'anima della trave, tensione assiale93 kip207.56 kip0.448Metà dell'altezza del muro dal fondo della base per il caso del
Cuscinetto dell'anima della trave, compressione assiale93 kip285.97 kip0.325Metà dell'altezza del muro dal fondo della base per il caso del
Beam web bearing interaction0.214Metà dell'altezza del muro dal fondo della base per il caso del
Cesoia per blocchi di piastre, taglio32 kip223.49 kip0.143Metà dell'altezza del muro dal fondo della base per il caso del
Cesoia per blocchi di piastre, assiali93 kip351.69 kip0.264Metà dell'altezza del muro dal fondo della base per il caso del
Interazione a taglio del blocco piastra0.090Metà dell'altezza del muro dal fondo della base per il caso del
Plate shear yielding and rupture32 kip198.81 kip0.161Metà dell'altezza del muro dal fondo della base per il caso del
Flessione della piastra32 kip631.11 kip0.051Metà dell'altezza del muro dal fondo della base per il caso del
Plate tension93 kip331.35 kip0.281Metà dell'altezza del muro dal fondo della base per il caso del
Interazione, tension yielding0.025Metà dell'altezza del muro dal fondo della base per il caso del
Interazione, tension rupture0.132Metà dell'altezza del muro dal fondo della base per il caso del
Compressione della placca93 kip506.25 kip0.184Metà dell'altezza del muro dal fondo della base per il caso del
Interazione, compressione0.025Metà dell'altezza del muro dal fondo della base per il caso del
Taglio del blocco d'anima della trave, assiali93 kip153.75 kip0.605Metà dell'altezza del muro dal fondo della base per il caso del
Rottura della tensione della trave93 kip305.88 kip0.304Metà dell'altezza del muro dal fondo della base per il caso del
Dettagli sulla parete HSS0.5 nella saldatura0.5 al massimo1.000Metà dell'altezza del muro dal fondo della base per il caso del
Saldare per sviluppare la piastra0.46875 pollici0.5 pollici0.938Metà dell'altezza del muro dal fondo della base per il caso del
Saldare alla parete HSS (risultante)98.351 kip448.85 kip0.219Metà dell'altezza del muro dal fondo della base per il caso del
Punzonatura per pareti HSS32 kip278 kip0.115Metà dell'altezza del muro dal fondo della base per il caso del
HSS wall under axial93 kip94.23 kip0.987Metà dell'altezza del muro dal fondo della base per il caso del

La connessione supera ogni controllo. The HSS wall under the 93 kip axial force governs at 0.987, and the next strength checks are the bolt group in slip (0.634) and block shear of the beam web (0.605). Everything in the plate is lightly loaded. The two ratios at 0.938 e 1.000 are detailing and weld sizing rules, not load against capacity.

Cosa cambiare se un controllo fallisce

  • HSS wall under axial: this is the usual limit. A thicker HSS wall helps most, because the strength grows with the square of the wall thickness. A deeper plate also helps. If neither can change, the axial force needs a different connection type.
  • Bolt slip or bearing: add bolt rows or a bolt column, oppure utilizzare un bullone più grande. For bearing under tension, a larger edge distance to the free end helps.
  • Beam web block shear or beam tension rupture: add bolt rows to lengthen the block and raise U, or use a beam with a thicker web.
  • Plate tension, compressione o taglio a blocco: rendere la piastra più profonda o più spessa, while keeping the ductility check below 1.0.
  • saldare: a larger weld, as long as it fits within the beam clearance and on the workable flat.

Auto Design is available for the single plate connection to an HSS column with shear and axial load. Cambia i bulloni, piastra e salda fino al superamento di ogni controllo, e mantiene i tuoi membri e i tuoi carichi come inseriti. Vedi il Progettazione automobilistica pagina per le preferenze a cui funziona.

Domande frequenti

Why are the bolts slip-critical in this example?

A beam carrying both shear and an axial force that reverses between tension and compression is a typical case for slip-critical bolts, so the joint does not slip back and forth through the hole clearance. The report then checks the group against slip with Eq. J3-4 under the resultant of the two forces.

Why does the report check bearing in two axial directions?

In tension the bolts bear toward the free end of the plate and the end of the beam, where the edge distance is short. In compression they bear toward the support and the span, where the plate edge is the weld line and the beam web is continuous. The two give different tear-out strengths, so both are checked, and the interaction uses the direction with the larger ratio.

Why is the weld stronger under the combined load than under shear alone?

A fillet weld loaded at an angle to its axis is stronger than one loaded along it, dal fattore 1 + 0.5 sin^1.5 of the angle in Eq. J2-5. The resultant here is at 71 degrees to the weld, which raises the weld strength by about 46%.

How does the shear-only connection compare?

The shear-only example, Design di connessione da piastra singola a colonna HSS, uses three 3/4 in bolts and a 3/8 in plate on the same beam and tube, and is governed by bolt shear at 0.660. The axial force here needs ten 1 in bolts and a 3/4 nel piatto, and the tube wall becomes the limit.

Can the axial force be larger with this tube?

Not by much. A 93 kip the HSS wall check is already at 0.987. For a larger axial force, utilizzare un tubo con pareti più spesse o una piastra più profonda.

Design a shear and axial single plate to HSS column connection for free

Ogni numero in questa pagina deriva da una soluzione. Selezionare la connessione a piastra singola ad una colonna HSS, entra nel tuo raggio, tubo, bulloni, taglio e carico assiale, e visualizza ciascuno di questi controlli nel tuo browser. Non c'è niente da installare.

Il modulo SkyCiv Connection Design è il software di progettazione della connessione dietro questo esempio. Ti fornisce il rapporto di calcolo completo con ogni equazione e i tuoi numeri in esso contenuti, come i passaggi precedenti, più ogni capacità e DCR, per AISC 360-22 e AISC 360-16 (LRFD e ASD) e AS 4100:2020. Il calcolatore di bulloni e calcolatore di saldatura coprire il gruppo di bulloni e verificare la saldatura da soli.

Riferimenti

  • AISC 360-16, Specifiche per edifici in acciaio strutturale: D3 (Tabella D3.1), F11.2 (Eq. F11-2), J2.4 (Eq. J2-4, J2-5), J3.3, J3.4 (Tabella J3.4), J3.5 (Tabella J3.5), J3.8 (Eq. J3-4), J3.10 (Eq. J3-6a, J3-6c), J4.1 (Eq. J4-1, J4-2), J4.2 (Eq. J4-3, J4-4), J4.3 (Eq. J4-5), J4.4 (Eq. J4-6).
  • Manuale AISC per le costruzioni in acciaio, 15th Edizione: Parte 9, Eq. 9-2, 9-4 e 9-15; Parte 10, Tabella 10-9, pagine 10-87 e 10-89 (Eq. 10-3, 10-4), Eq. 10-7b (. 10-153); Parte 15, Tabella 15-3.
  • HSS wall under axial load: yield line analysis by R. Kapp, as used in the report.
  • Come progettare una connessione a taglio a piastra singola (Colonna a forma di W)
  • Progettazione di connessioni in acciaio mediante AISC 360-16
Harold Munalem, Responsabile di prodotto per SkyCiv Connection Design

Harold Munalem
Responsabile del prodotto, Connection Design
10+ anni nella progettazione di connessioni in acciaio
LinkedIn

Come possiamo aiutare?

×

Aggiornato novembre 24, 2026

Ha ancora bisogno di aiuto? Ci contatti

Vai all'inizio