NBCC 2015 Seismic Load Calculations

SkyCiv Load Generator calculates NBCC 2015 seismic loads for buildings with the Equivalent Static Force Procedure of the National Building Code of Canada 2015. It gets the seismic hazard values for your site in Canada, then gives you the design spectral acceleration, the specified lateral earthquake force (base shear), the vertical distribution of seismic forces and the overturning moments. This page explains each input of the seismic workflow and how the calculation uses it.

Free accounts can try the workflow for up to 3 solves per week. With a Professional Account or the standalone Load Generator module, you get unlimited solves, the full seismic results and the detailed seismic calculation report.

Workflow Overview

The NBCC 2015 seismic workflow follows the same top-to-bottom order as the rest of the SkyCiv Load Generator:

  1. Select NBCC 2015 as the design code.
  2. In Site Data, select the Importance Category and, under For Seismic Load, the Site Class, then enter an address in Canada.
  3. Review the Seismic Hazard Values returned for the site.
  4. In Structure Data, select the Building structure and enter its dimensions.
  5. Open Seismic Load, define the seismic parameters and the floor weights, and confirm them.
  6. Click Calculate Loads and review the results.

For NBCC 2015, the seismic calculation is available for the Building structure only. NBCC 2015 seismic calculations are done in metric units (m, kN). If you design to the newer edition, see NBCC 2020 Seismic Load Calculations.

Site Data: NBCC 2015 Seismic Hazard Values

Importance Category

The Importance Category (Low, Normal, High or Post Disaster) is selected in Site Data and is shared with the wind and snow calculations. For the seismic calculation, it sets the earthquake importance factor \(I_{E}\) of Table 4.1.8.5, used at the ultimate limit state:

Importance Category \(I_{E}\)
Low 0.8
Normal 1.0
High 1.3
Post Disaster 1.5

Site Class

Open For Seismic Load in Site Data and select the Site Class (Table 4.1.8.4-A of NBCC 2015):

  • A – Hard rock
  • B – Rock
  • C – Very dense soil and soft rock
  • D – Stiff soil
  • E – Soft soil

Site Class F (soils that need a site-specific evaluation) is not available. Selecting a Site Class looks up the seismic data for the address you entered and enables the Seismic Load button for buildings. NBCC 2015 seismic hazard values are given for a 2% probability of exceedance in 50 years (2475-year return period), so there is no probability to select.

Seismic Hazard Values

Once the location and Site Class are set, the Load Generator fills in the Seismic Hazard Values for the site:

Input What it is
\(S_{a}(0.2)\), \(S_{a}(0.5)\), \(S_{a}(1.0)\), \(S_{a}(2.0)\), \(S_{a}(5.0)\), \(S_{a}(10.0)\) 5% damped spectral response acceleration at periods of 0.2, 0.5, 1.0, 2.0, 5.0 and 10.0 s, in g
PGA Peak ground acceleration, in g
PGV Peak ground velocity, in m/s

All eight values are required. You can edit them, for example to use the values of the NBCC 2015 seismic hazard calculator for your site. The map pop-up also shows the values and the source they come from.

How the Site Data Is Used

The calculation turns the site hazard into the design spectral acceleration \(S(T)\) of Article 4.1.8.4:

  1. It sets the reference peak ground acceleration: \(PGA_{ref} = 0.8\,PGA\) when \(S_{a}(0.2)/PGA < 2.0\), and \(PGA_{ref} = PGA\) otherwise.
  2. It reads the site coefficients \(F(T)\), \(F(PGA)\) and \(F(PGV)\) for the selected Site Class and \(PGA_{ref}\) from Tables 4.1.8.4-B to 4.1.8.4-I, interpolating between table values.
  3. It calculates \(S(T)\) at each period from \(F(T)\) and \(S_{a}(T)\), as in Article 4.1.8.4(9).

Get started

Want to try it for yourself?

Try SkyCiv today for free!

Sign Up Free

Structure Data

Select Building in Structure Data and enter its dimensions. The height from the ground to the top of the roof is used as the structure height \(h_{n}\) in the approximate fundamental period.

SkyCiv Load Generator Structure Data for a building

Figure 1. Structure Data for a building.

NBCC 2015 Seismic Load Parameters

Click the Seismic Load button to define the seismic parameters. When you confirm them with Confirm Seismic Parameters, the checkbox beside the button is ticked and the seismic load is included in the calculation:

SkyCiv Load Generator Seismic Load button and checkbox

Figure 2. Seismic Load button and checkbox.

The seismic parameters for NBCC 2015 are:

Input Default How it is used
Structure System Concrete Moment-Resisting Frame Sets the formula for the approximate period \(T_{a}\) and the type of system used for the higher mode factor \(M_{v}\) and the overturning moment reduction factor \(J\) (Table 4.1.8.11). It also selects the minimum base shear: at \(T = 4.0\,\text{s}\) for coupled walls and wall/wall-frame systems, at \(T = 2.0\,\text{s}\) for the others.
\(T_{a}\) (or \(T_{s}\)) Filled in from the Structure System Fundamental lateral period of vibration of the building (Article 4.1.8.1(7)), in seconds. Must be between 0 and 10.
\(R_{d}\) 4.0 Ductility-related force modification factor (Table 4.1.8.9). Must be between 0 and 10.
\(R_{o}\) 1.0 Overstrength-related force modification factor (Table 4.1.8.9). Must be between 0 and 10.
Floor Weights None Level, Elevation and Weight of each floor, used for the seismic weight \(W\), the vertical distribution of the base shear and the overturning moments.

NBCC seismic load parameters in SkyCiv Load Generator

Figure 3. Seismic Load parameters (shared by NBCC 2015 and NBCC 2020).

Structure System and Approximate Period

When you select a Structure System, the Load Generator fills in \(T_{a}\) from the ground to top of roof height \(h_{n}\) (in m):

Structure System Approximate period
Steel Moment-Resisting Frame \(T_{a} = 0.085\,h_{n}^{0.75}\)
Concrete Moment-Resisting Frame \(T_{a} = 0.075\,h_{n}^{0.75}\)
Moment-Resisting Frame (Others) \(T_{a} = 0.1N\)
Braced Frame \(T_{a} = 0.025\,h_{n}\)
Coupled Wall \(T_{a} = 0.05\,h_{n}^{0.75}\)
Wall/Wall-Frame \(T_{a} = 0.05\,h_{n}^{0.75}\)
All other structural systems \(T_{a} = 0.05\,h_{n}^{0.75}\)

For Moment-Resisting Frame (Others), \(T_{a}\) is not filled in: enter it yourself, with \(N\) the number of storeys above ground level. If the field is left empty, the calculation uses the number of rows in the Floor Weights table as \(N\). You can replace \(T_{a}\) with a period from a dynamic analysis within the limits of Article 4.1.8.11(3): it changes \(S(T_{a})\) and the base shear.

Floor Weights

Click Add Floor Weights Data to add a row per level, and Clear to empty the table. Each row needs a Level name, an Elevation above the base and a Weight, both greater than 0. The sum of the weights is the seismic weight \(W\) of the building (Article 4.1.4.1). At least one row is required to calculate.

Get started

Want to try it for yourself?

Try SkyCiv today for free!

Sign Up Free

Equivalent Static Force Procedure

The Load Generator calculates the specified lateral earthquake force \(V\) with the Equivalent Static Force Procedure of Article 4.1.8.11:

[math] V = \frac{S(T_{a})\,M_{v}\,I_{E}\,W}{R_{d}\,R_{o}} [math]

\(V\) is taken not less than the minimum base shear:

[math] V_{min} = \frac{S(2.0)\,M_{v}\,I_{E}\,W}{R_{d}\,R_{o}} [math]

for moment-resisting frames, braced frames and other systems (with \(S(4.0)\) and \(M_{v}\) at 4.0 s for walls, coupled walls and wall-frame systems). For an \(R_{d}\) of 1.5 or more, \(V\) need not be more than:

[math] V_{max} = \max\left(\frac{2}{3}\,\frac{S(0.2)\,I_{E}\,W}{R_{d}\,R_{o}},\ \frac{S(0.5)\,I_{E}\,W}{R_{d}\,R_{o}}\right) [math]

\(S(T_{a})\) is interpolated from the design spectrum, and \(M_{v}\) and \(J\) come from Table 4.1.8.11 with the ratio \(S(0.2)/S(5.0)\), \(T_{a}\) and the Structure System. The base shear is then distributed over the height of the building (Article 4.1.8.11(7)):

[math] F_{x} = \frac{(V – F_{t})\,W_{x}h_{x}}{\sum W_{i}h_{i}} [math]

where \(F_{t} = 0.07\,T_{a}V \le 0.25V\) is a concentrated force added at the top level, and \(F_{t} = 0\) when \(T_{a} < 0.7\,\text{s}\). The overturning moment at each level, \(M_{x}\), is reduced by the factor \(J_{x}\) of Article 4.1.8.11(8).

Results

Click Calculate Loads in the menu bar to run the calculation. The results show:

  • The summary of the seismic parameters, including \(I_{E}\), \(T_{a}\), \(M_{v}\), \(J\) and the base shear \(V\).
  • The vertical distribution of seismic forces, \(F_{x}\) per level.
  • The overturning moments, \(M_{x}\) per level.
  • The design spectral acceleration \(S(T)\) table and chart, with \(S(T_{a})\) marked.

Free users see the seismic parameters only. The forces, overturning moments and design spectral acceleration are shown to Professional account users and to users of the standalone Load Generator module. Click Download Report beside Calculate Loads for a summary report of the inputs and results.

Detailed Seismic Calculation Report

The Detailed Seismic Calculation Report button in the results opens a step-by-step NBCC 2015 calculation, available to Professional account users and to users of the standalone Load Generator module. It shows every parameter, formula and code reference used: the site seismic parameters, the \(F(T)\) and \(S(T)\) table, \(M_{v}\) and \(J\), the base shear checks, the vertical distribution of forces with a diagram, the overturning moments and the design spectral acceleration chart. It is ready to attach to your design calculations.