Steel Frame: Überblick
The purpose of this test case is to validate some of the unit conversion for imperial units. In diesem Beispiel, the following units were changed:
- Moment (kip-ft to lb-in)
- Macht (kip to lb)
- Druck (ksi to psi)
The results are compared internally due to the concern of the verification only limited in the unit conversion of results and not necessarily the analysis.
Modelleinrichtung
The structure is a 123-node, 276-Elementrahmenstruktur, die von festen Stützen getragen wird. The building consists of general section beams made from steel.
Bewertungspunkte: 10
Typ lösen: Lineare Analyse

Analyseergebnisse
Ergebnis | Ort | SkyCiv Default | SkyCiv Converted Units | Conversion Equivalent |
---|---|---|---|---|
Moment Z. | Mitglied 183, Knoten starten | 11.531 kip-ft | 138368.621 lb-in | 11.531 kip-ft |
Moment Y. | Mitglied 62, Knoten beenden | -0.044 kip-ft | -522.878 lb-in | -0.044 kip-ft |
Schere Y. | Mitglied 58, Knoten beenden | -0.450 pennen | -449.583 Pfund | -0.450 pennen |
Schere Z. | Mitglied 101, Knoten beenden | -0.226 pennen | -225.988 Pfund | -0.226 pennen |
Reaktion Y. | Knoten 93 | 4.597 pennen | 4597.272 Pfund | 4.597 pennen |
Reaktion Y. | Knoten 64 | 2.638 pennen | 2638.141 Pfund | 2.638 pennen |
Axial | Mitglied 110 | 0.215 pennen | 214.907 Pfund | 0.215 pennen |
Axial | Mitglied 168 | 5.409 pennen | 5408.611 Pfund | 5.409 pennen |
Top Biegespannung Z. | Mitglied 207, Knoten starten | 327.075 KSI | 327074.571 psi | 327.075 KSI |
Top Biegespannung Y. | Mitglied 252, Knoten beenden | 2073.306 KSI | 2073305.516 psi | 2073.306 KSI |