To design a bolted flange plate moment connection to a rectangular HSS column to AISC 360-16, you turn the beam moment into a tension and compression force in each flange, Überprüfen Sie die Flanschplatten, bolts and beam flanges for that force, and then check what the force does to the tube: the weld to the HSS face, local yielding of the plate on a flexible wall, and local yielding of the HSS sidewalls. A single plate on the beam web carries the shear.
This page works through one example: a W18x50 beam framing into the 4 in face of an HSS8x4x1/2 column, mit 38 Kip-ft-Moment, 19 Kip-Schere und 66 kip axial under LRFD, 3/4 in Grade 50 flange plates on four 1 jeweils in A490-SC-Schrauben, und ein 3/8 in A36 shear plate. Jede Gleichung wird mit ihren Zahlen ausgeschrieben, in der gleichen Reihenfolge wie das Berechnungsblatt SkyCiv Connection Design Modul produziert dafür.
What is a flange plate moment connection to an HSS column?
A flange plate Momentenanschluss has one plate on the top flange and one on the bottom flange of the beam. Each plate is shop-welded to the column and field-bolted to the beam flange, so the moment passes through the plates as a tension and compression couple. A shear plate on the web takes the beam reaction. For a W-shape column the plates weld to the column flange, as in So entwerfen Sie eine Flanschplatten-Momentverbindung.
On an HSS column the plates weld straight onto the tube wall, which is much more flexible than a column flange. A plate pulling on the middle of a thin wall cannot spread its force evenly across its width, so AISC reduces the plate to an effective width, and the sidewalls of the tube are checked for the force coming in from the corners. Those HSS checks are the part of the design this page adds to the W-shape example.
You can run this connection in the Rechner für Flanschplattenverbindungen.

Höhe der Beispielverbindung. The flange plates are welded to the HSS face and bolted to the beam flanges; the shear plate carries the reaction.

Abschnitt A-A, a plan cut through the top flange plate, showing the four bolts at a 3 5/8 in gage and the plate against the 4 in HSS face.

3D-Ansicht der Verbindung im SkyCiv Connection Design.
How do you design a flange plate moment connection to an HSS column? Die Schritte auf einen Blick
The report has two sections: the flange plates (Schritte 1 zu 14) and the shear plate (Schritte 15 zu 24).
- Detaillierungsgrenzen am Trägerflansch.
- Flange bolts in slip under the flange force.
- Bolt bearing on the flange plate.
- Bolt bearing on the beam flange.
- Blockscherung der Flanschplatte.
- Blockschub des Trägerflansches.
- Spannungsnachgeben und Bruch der Flanschplatte.
- Tension rupture of the beam flange.
- Biegebruch des Trägers an den Flanschschraubenlöchern.
- Compression of the flange plate.
- Detailing limit at the HSS face.
- Fillet weld from the flange plate to the HSS face.
- Local yielding of the flange plate on the HSS wall.
- Local yielding of the HSS sidewalls.
- Detailing limits of the shear plate at the beam.
- Shear plate bolt group.
- Bearing on the shear plate.
- Auflage auf dem Balkensteg.
- Effektive Stärke der Stegbolzengruppe.
- Block shear of the shear plate.
- Shear yielding and rupture of the shear plate.
- Detailing limits of the shear plate at the HSS wall.
- Weld from the shear plate to the HSS wall.
- HSS-Wandstanzung.
Designeingaben für dieses Beispiel
Der Designcode ist AISC 360-16 LRFD. Abschnittseigenschaften stammen aus dem AISC-Handbuch. How the loads are entered is explained in Lasten und Lastkombinationen.
| Artikel | Symbol | Wert |
|---|---|---|
| Factored moment (starke Achse) | [mathin] M_{ux} [mathin] | 38 kip-ft |
| Faktorisierte Scherung | [mathin] V_{u} [mathin] | 19 kip |
| Faktorisierte Axialspannung / Druck- | [mathin] T_{u},\ C_{u} [mathin] | 66 kip / 66 kip |
| Beam | B18x50, ASTM A992 | |
| Strahltiefe / Bahndicke | [mathin] d_{bm},\ t_{wb} [mathin] | 18 im / 0.355 im |
| Breite des Trägerflansches / Dicke | [mathin] b_{fb},\ t_{fb} [mathin] | 7.5 im / 0.57 im |
| Strahlbereich / Ertrag / Zugfestigkeit | [mathin] A,\ F_{yb},\ F_{ub} [mathin] | 14.7 in² / 50 ksi / 65 ksi |
| Spalte | HSS8x4x1/2, ASTM A500 Gr. C. | |
| Width of the HSS face the plates weld to | [mathin] b [mathin] | 4 im |
| HSS-Tiefe / Designwandstärke | [mathin] h,\ t [mathin] | 8 im / 0.465 im |
| Workable flat of the face | [mathin] W_{flat} [mathin] | 2.875 im |
| Säulenertrag / Zugfestigkeit | [mathin] F_{ys},\ F_{us} [mathin] | 50 ksi / 62 ksi |
| Flange plate item | Symbol | Wert |
|---|---|---|
| Flanschplatten | PL 3/4 x 6 1/2 x 6 1/2, ASTM A572 Gr. 50 (50 / 65 ksi) | |
| Plattenbreite / Länge / Dicke | [mathin] b_{fp},\ L_{fp},\ t_{fp} [mathin] | 6.5 im / 6.5 im / 0.75 im |
| Flanschschrauben | 1 im A490-SC, Klasse a, 1 Scherebene | |
| Löcher | Flanschplatte: übergroß (OVS). Trägerflansch: Standard (STD) | |
| Bolzenlinien / Messgerät | [mathin] n_{r},\ g_{a} [mathin] | 2 / 3.625 im |
| Bolts per line / Abstand | [mathin] n_{c},\ s_{c} [mathin] | 2 / 3 im |
| Plattenrandabstände, über / entlang des Balkens | [mathin] L_{ev\_fp},\ L_{eh\_fp} [mathin] | 1.4375 im / 1.5 im |
| Beam flange edge distances, über / along | [mathin] L_{ev\_bf},\ L_{eh\_bf} [mathin] | 1.9375 im / 1.5 im |
| Erection gap | 1/4 im | |
| Weld to HSS face | 1/2 im Filet, E70XX |
| Shear plate item | Symbol | Wert |
|---|---|---|
| Shear plate | PL 3/8 x 3 1/2 x 9, ASTM A36 (36 / 58 ksi) | |
| Stegbolzen | 1 im A490-N, Threads enthalten | |
| Löcher | Teller: horizontal kurzgeschlitzt (HSSL). Balkennetz: Standard (STD) | |
| Bolzenreihen / Abstand / Stützen | [mathin] n_{r},\ s_{r},\ n_{c} [mathin] | 3 / 3 im / 1 |
| Edge distances / weld to bolt line | [mathin] L_{e},\ a [mathin] | 1.5 im / 2 im |
| Weld to HSS face | 3/16 beidseitig filetieren, E70XX |
Flange plate section
Schritt 1: Detaillierungsgrenzen am Trägerflansch (AISC 360-16 J3.3, J3.4)
The bolt gage across the flange, the spacing along it and the edge distances on both the plate and the beam flange are checked against the J3.3 and Table J3.4 limits for a 1 im Bolzen, with the oversized-hole increment on the plate.
| Detaillierungslimit | Limit (im) | Tatsächlich (im) | DCR | Ergebnis |
|---|---|---|---|---|
| Mindeststärke | 3.625 | 3.625 | 1.000 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Mindestabstand der Bolzensäulen | 2.667 | 3.000 | 0.889 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Maximaler Schraubenspaltenabstand | 6.000 | 3.000 | 0.500 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Minimaler vertikaler Randabstand der Platte | 1.375 | 1.438 | 0.956 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Minimaler horizontaler Randabstand der Platte | 1.375 | 1.500 | 0.917 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Minimaler vertikaler Randabstand des Trägerflansches | 1.250 | 1.938 | 0.645 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Minimaler horizontaler Randabstand des Trägerflansches | 1.250 | 1.500 | 0.833 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
The gage equals the module’s minimum gage, so that row sits at exactly 1.000:
[math] DCR = \frac{3.625\,in}{3.625\,in} = 1.000 [math]
DCR = 1.000, in Ordnung
Schritt 2: Flange bolts in slip under the flange force (AISC 360-16 J3.8)
The moment becomes a force in each flange over the distance between flange centers, and half the axial force is added to it:
[math] P_{uF} = \frac{M_{ux}}{d_{bm} – t_{fb}} + \frac{P_{u}}{2} = \frac{38\,kip\text{-}ft}{18\,in – 0.57\,in} + \frac{66\,kip}{2} = 59.162\,kip [math]
This flange force is the demand for every check in the flange plate section. The four bolts are slip-critical, Gl. J3-4, with the report’s filler factor of 0.85:
[math] \phi R_{n} = \phi\, \mu\, D_{u}\, h_{f}\, T_{b}\, N_{s}\, n_{r}\, n_{c} = (0.85) \times (0.3) \times (1.13) \times (0.85) \times (64\,kip) \times (1) \times (2) \times (2) = 62.701\,kip [math]
DCR = 59.162 kip / 62.701 kip = 0.944 < 1.0, in Ordnung
Schritt 3: Bolt bearing on the flange plate (AISC 360-16 J3.10)
The force runs along the beam, so the bolts bear toward the plate end. Mit dem 1.25 in oversized hole:
[math] l_{c1} = 1.5 – \frac{1.25}{2} = 0.875\,in, \qquad l_{c2} = 3 – 1.25 = 1.75\,in [math]
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.875, 2.4) \times 0.75 \times 65 \times 2 + \min(1.2 \times 1.75, 2.4) \times 0.75 \times 65 \times 2 \times 1 \right] = 230.34\,kip [math]
DCR = 59.162 kip / 230.34 kip = 0.257 < 1.0, in Ordnung
Schritt 4: Bolt bearing on the beam flange (AISC 360-16 J3.10)
[math] l_{c1} = 1.5 – \frac{1.125}{2} = 0.9375\,in, \qquad l_{c2} = 1.875\,in [math]
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.57 \times 65 \times 2 + \min(1.2 \times 1.875, 2.4) \times 0.57 \times 65 \times 2 \times 1 \right] = 187.57\,kip [math]
DCR = 59.162 kip / 187.57 kip = 0.315 < 1.0, in Ordnung
Schritt 5: Blockscherung der Flanschplatte (AISC 360-16 J4.3)
Three tear-out shapes are checked, all with [mathin] U_{bs} = 1 [mathin] und Gl. J4-5:
[math] \phi R_{n} = \phi \left( 0.6 F_{up} A_{nv} + U_{bs} F_{up} A_{nt} \le 0.6 F_{yp} A_{gv} + U_{bs} F_{up} A_{nt} \right) [math]
| Muster | Agv (in²) | Anv (in²) | Ant (in²) | phi Rn (kip) |
|---|---|---|---|---|
| L.: eine Scherebene, Spannung über die Schrauben bis zu einer Kante | 3.375 | 1.8984 | 2.3203 | 168.64 |
| U.: zwei Scherebenen, Spannung zwischen den Bolzenlinien | 6.75 | 3.7969 | 1.7344 | 195.61 |
| 2L.: zwei Scherebenen, Spannung von jeder Schraubenlinie bis zum Rand | 6.75 | 3.7969 | 1.1719 | 168.19 |
For the governing 2L pattern:
[math] A_{nt} = 2 \times 0.75 \left[ 1.4375 – 0.5 \times (1.25 + 0.0625) \right] = 1.1719\,in^{2} [math]
[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.7969 + 65 \times 1.1719 \le 0.6 \times 50 \times 6.75 + 65 \times 1.1719 \right) = 168.19\,kip [math]
DCR = 59.162 kip / 168.19 kip = 0.352 < 1.0, in Ordnung
Schritt 6: Blockschub des Trägerflansches (AISC 360-16 J4.3)
The beam flange tears out as two outer strips:
[math] A_{nt} = 0.57 \left[ 7.5 – 3.625 – 1 \times (1.1875) \right] = 1.5319\,in^{2} [math]
[math] A_{gv} = 2 \times 0.57 \left[ 1.5 + 3 \right] = 5.13\,in^{2}, \qquad A_{nv} = 2 \times 0.57 \left( 4.5 – 1.5 \times 1.1875 \right) = 3.0994\,in^{2} [math]
[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.0994 + 65 \times 1.5319 \le 0.6 \times 50 \times 5.13 + 65 \times 1.5319 \right) = 165.34\,kip [math]
DCR = 59.162 kip / 165.34 kip = 0.358 < 1.0, in Ordnung
Schritt 7: Spannungsnachgeben und Bruch der Flanschplatte (AISC 360-16 J4.1)
[math] \phi R_{n\_ty} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]
[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.75 \left[ 6.5 – 2 \times (1.3125) \right] = 141.68\,kip [math]
DCR = 59.162 kip / 141.68 kip = 0.418 < 1.0, in Ordnung
Schritt 8: Tension rupture of the beam flange (AISC 360-16 D3, J4.1)
The flange force is taken by half the beam’s area, less the two flange holes, with the shear lag factor U = 0.283 from Table D3.1 case 2:
[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.283 \left[ 0.5 \times 14.7 – 2 \times (1.1875) \times 0.57 \right] = 82.726\,kip [math]
DCR = 59.162 kip / 82.726 kip = 0.715 < 1.0, in Ordnung
Schritt 9: Biegebruch des Trägers an den Flanschschraubenlöchern (AISC 360-16 F13.1)
[math] A_{fg} = 7.5 \times 0.57 = 4.275\,in^{2}, \qquad A_{fn} = 4.275 – 2 \times (1.1875) \times 0.57 = 2.9213\,in^{2} [math]
With Fy / Fu = 0.76923, nicht mehr als 0.8, Yt = 1. Dann:
[math] F_{u} A_{fn} = 189.88\,kip \lt Y_{t} F_{y} A_{fg} = 213.75\,kip [math]
so the holes reduce the flexural strength and Eq. F13-1 applies, with the beam’s elastic modulus of 89.005 in³:
[math] M_{n} = \frac{F_{ub} A_{fn}}{A_{fg}}\, S_{x} = \frac{65 \times 2.9213}{4.275} \times 89.005 = 329.44\,kip\text{-}ft [math]
[math] \phi R_{n} = \frac{0.9\, M_{n}}{d_{bm} – t_{fb}} = \frac{0.9 \times 329.44\,kip\text{-}ft}{18\,in – 0.57\,in} = 204.13\,kip [math]
DCR = 59.162 kip / 204.13 kip = 0.290 < 1.0, in Ordnung
Schritt 10: Compression of the flange plate (AISC 360-16 J4.4)
KL/r of the plate is no more than 25, also Gl. J4-6 applies with no buckling reduction:
[math] \phi R_{n} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]
DCR = 59.162 kip / 219.38 kip = 0.270 < 1.0, in Ordnung
Schritt 11: Detailing limit at the HSS face
| Detaillierungslimit | Limit (im) | Tatsächlich (im) | DCR | Ergebnis |
|---|---|---|---|---|
| Maximale Kehlnahtgröße pro Trägerabstand | 0.500 | 0.500 | 1.000 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
Das 1/2 in weld exactly fills the available clearance, was erlaubt ist:
DCR = 1.000, in Ordnung
Schritt 12: Fillet weld from the flange plate to the HSS face (AISC 360-16 K1, K5, J2.4)
This is where the HSS changes the design. The base metal limit first, from Manual Eq. 9-2:
[math] D_{max} = \frac{(0.375)(65) \le (0.465)(62)}{3.09} = 7.8883 [math]
Das 6.5 in der Platte ist breiter als die 4 in HSS face. The report allows that, but only the width over the face delivers load into it:
[math] B_{p,eff} = b_{fp} \le b = \min(6.5\,in, 4\,in) = 4\,in [math]
Gl. K1-1 then reduces it to the effective width:
[math] B_{e} = \left( \frac{10 t}{b} \right) \left( \frac{F_{ys}\, t}{F_{yp}\, t_{fp}} \right) B_{p,eff} \le B_{p,eff} = \left( \frac{10 \times 0.465}{4} \right) \left( \frac{50 \times 0.465}{50 \times 0.75} \right) \times 4 = 2.883\,in [math]
Per K5 the effective weld length is 2Be, and the report also caps Be at the workable flat:
[math] L_{w} = 2 \left( B_{e} \le W_{flat} \right) = 2 \times \min(2.883, 2.875) = 5.75\,in [math]
[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.5, \frac{7.8883}{16}\right) \times 5.75 = 63.144\,kip [math]
DCR = 59.162 kip / 63.144 kip = 0.937 < 1.0, in Ordnung
Schritt 13: Local yielding of the flange plate on the HSS wall (AISC 360-16 K1, Bemessungsleitfaden 24)
The same effective width idea limits the force the plate can deliver into the wall. The report uses φ = 0.95 from AISC Design Guide 24, Tabelle 7-2:
[math] \phi R_{n} = \phi \left( \frac{10\, t^{2}\, F_{ys}\, B_{p,eff}}{b} \le F_{yp}\, t_{fp}\, B_{p,eff} \right) = 0.95 \times \min\left( \frac{10 \times 0.465^{2} \times 50 \times 4}{4},\; 50 \times 0.75 \times 4 \right) = 102.71\,kip [math]
DCR = 59.162 kip / 102.71 kip = 0.576 < 1.0, in Ordnung
Schritt 14: Local yielding of the HSS sidewalls
The flange force also reaches the two sidewalls of the tube through the corners. The report checks them with the expression below and φ = 1.0, without citing a clause, so it is the software’s limit for this check:
[math] \phi R_{n} = \phi \times 2 F_{ys}\, t \left[ 5 (1.5 t) + t_{fp} \right] = 1.0 \times 2 \times 50 \times 0.465 \left[ 5 \times (1.5 \times 0.465) + 0.75 \right] = 197.04\,kip [math]
DCR = 59.162 kip / 197.04 kip = 0.300 < 1.0, in Ordnung
Shear plate section
The shear plate is a conventional single plate welded to the HSS face and carries the 19 Kippreaktion. Its checks follow the shear tab procedure, worked in full in So entwerfen Sie eine Einzelplatten-Scherverbindung, with the HSS face checks added.
Schritt 15: Detailing limits of the shear plate at the beam (AISC 360-16 J3.3, J3.4)
| Detaillierungslimit | Limit (im) | Tatsächlich (im) | DCR | Ergebnis |
|---|---|---|---|---|
| Mindestabstand der Schraubenreihen | 2.667 | 3.000 | 0.889 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Maximaler Schraubenreihenabstand | 6.000 | 3.000 | 0.500 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Minimaler vertikaler Randabstand der Platte | 1.250 | 1.500 | 0.833 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Minimaler horizontaler Randabstand der Platte | 1.375 | 1.500 | 0.917 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Minimaler horizontaler Randabstand des Strahls | 1.250 | 1.500 | 0.833 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Mindestverbindungstiefe | 7.750 | 9.000 | 0.861 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Maximale Verbindungstiefe | 16.000 | 9.000 | 0.563 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
[math] DCR = \frac{1.375\,in}{1.5\,in} = 0.917 [math]
DCR = 0.917 < 1.0, in Ordnung
Schritt 16: Shear plate bolt group (AISC 360-16 J3.6)
No fillers, Also [mathin] h_{f} = 1 [mathin] by J5.2(ein). The report uses C = 3 for the three web bolts:
[math] \phi R_{n} = 0.75 \times 68 \times \frac{\pi}{4} (1\,in)^{2} \times (1) \times (3) \times (1) = 120.17\,kip [math]
DCR = 19 kip / 120.17 kip = 0.158 < 1.0, in Ordnung
Schritt 17: Bearing and tear-out on the shear plate (AISC 360-16 J3.10)
[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.375 \times 58 + \min(1.2 \times 1.875, 2.4) \times 0.375 \times 58 \times 2 \right] \times \frac{3}{3} = 91.758\,kip [math]
DCR = 19 kip / 91.758 kip = 0.207 < 1.0, in Ordnung
Schritt 18: Bearing and tear-out on the beam web (AISC 360-16 J3.10)
[math] \phi R_{n} = (0.75) \times \min(1.2 \times 1.875, 2.4) \times (0.355\,in) \times (65\,ksi) \times (3) = 116.82\,kip [math]
DCR = 19 kip / 116.82 kip = 0.163 < 1.0, in Ordnung
Schritt 19: Effektive Stärke der Stegbolzengruppe (AISC 360-16 J3.6 Kommentar)
Pro Bolzen: Schub- 40.055 kip, plate edge bolt 18.352 kip, plate inner bolt 36.703 kip and beam web 38.939 kip. Schrauben 1 und 2 take the inner-bolt value and bolt 3 the edge value:
[math] \Sigma \phi r_{eff} = 2 \times (36.703\,kip) + 18.352\,kip = 91.758\,kip, \qquad \phi R_{n,eff} = 91.758 \times \frac{3}{3} = 91.758\,kip [math]
DCR = 19 kip / 91.758 kip = 0.207 < 1.0, in Ordnung
Schritt 20: Block shear of the shear plate (AISC 360-16 J4.3)
[math] A_{nt} = 0.30469\,in^{2}, \quad A_{gv} = 2.8125\,in^{2}, \quad A_{nv} = 1.6992\,in^{2} [math]
[math] \phi R_{n} = 0.75 \left( 0.6 \times 58 \times 1.6992 + 58 \times 0.30469 \le 0.6 \times 36 \times 2.8125 + 58 \times 0.30469 \right) = 57.604\,kip [math]
DCR = 19 kip / 57.604 kip = 0.330 < 1.0, in Ordnung
Schritt 21: Shear yielding and rupture of the shear plate (AISC 360-16 J4.2)
[math] \phi R_{n\_sy} = 1.0 \times 0.6 \times 36 \times 3.375 = 72.9\,kip, \qquad \phi R_{n\_sr} = 0.75 \times 0.6 \times 58 \times 2.0391 = 53.22\,kip [math]
DCR = 19 kip / 53.22 kip = 0.357 < 1.0, in Ordnung
Schritt 22: Detailing limits of the shear plate at the HSS wall
Die Bearbeitbarkeits- und Schlankheitswerte sind die Modulgrenzen für eine einzelne Platte an einer HSS-Wand.
| Detaillierungslimit | Limit (im) | Tatsächlich (im) | DCR | Ergebnis |
|---|---|---|---|---|
| Maximale Kehlnahtgröße pro Trägerabstand | 0.500 | 0.188 | 0.376 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Maximale Kehlnahtgröße pro HSS-bearbeitbarer Fläche | 0.885 | 0.188 | 0.212 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Maximale HSS-Wandschlankheit b/t | 33.716 | 5.602 | 0.166 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
DCR = 0.376 < 1.0, in Ordnung
Schritt 23: Weld from the shear plate to the HSS wall (AISC 360-16 J2.4)
[math] D_{max} = \frac{(0.1875)(58) \le (0.465)(62)}{3.09} = 3.5194, \qquad L_{w} = 2 \left[ 9 – 2 \times 0.1875 \right] = 17.25\,in [math]
[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.1875, \frac{3.5194}{16}\right) \times \left[ 1 + 0.5 \sin^{1.5}(0) \right] \times 17.25 = 72.042\,kip [math]
DCR = 19 kip / 72.042 kip = 0.264 < 1.0, in Ordnung
Schritt 24: HSS-Wandstanzung (AISC-Handbuch Gl. 10-7b, seite 10-153)
[math] \phi R_{n} = \frac{0.75 \times 62 \times 0.465 \times 9^{2}}{5 \times 2} = 175.14\,kip [math]
DCR = 19 kip / 175.14 kip = 0.108 < 1.0, in Ordnung
Zusammenfassung der Designprüfungen
| Design-Check | Nachfrage | Die SkyCiv Foundation umfasst das Design von isolierten Fundamenten, die den australischen Standards¹ entsprechen | DCR | Ergebnis |
|---|---|---|---|---|
| Flansch: detailing at beam | 3.625 im Messgerät | 3.625 in min | 1.000 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Flange bolts in slip | 59.162 kip | 62.701 kip | 0.944 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Lager auf Flanschplatte | 59.162 kip | 230.34 kip | 0.257 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Lager am Trägerflansch | 59.162 kip | 187.57 kip | 0.315 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Blockschere, Flanschplatte | 59.162 kip | 168.19 kip | 0.352 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Blockschere, Trägerflansch | 59.162 kip | 165.34 kip | 0.358 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Spannung der Flanschplatte | 59.162 kip | 141.68 kip | 0.418 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Beam flange tension rupture | 59.162 kip | 82.726 kip | 0.715 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Beam flexural rupture at holes | 59.162 kip | 204.13 kip | 0.290 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Kompression der Flanschplatte | 59.162 kip | 219.38 kip | 0.270 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Flansch: detailing at HSS face | 0.5 in Schweißnaht | 0.5 in max | 1.000 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Flange plate weld to HSS | 59.162 kip | 63.144 kip | 0.937 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Flange plate local yielding | 59.162 kip | 102.71 kip | 0.576 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| HSS sidewall local yielding | 59.162 kip | 197.04 kip | 0.300 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Shear plate: detailing at beam | 1.375 in min | 1.5 in edge | 0.917 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Shear plate bolt group | 19 kip | 120.17 kip | 0.158 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Bearing on shear plate | 19 kip | 91.758 kip | 0.207 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Lager am Trägersteg | 19 kip | 116.82 kip | 0.163 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Effective web bolt group strength | 19 kip | 91.758 kip | 0.207 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Blockschere, shear plate | 19 kip | 57.604 kip | 0.330 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Schernachgeben und Bruch, shear plate | 19 kip | 53.22 kip | 0.357 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Shear plate: detailing at HSS wall | 0.188 in Schweißnaht | 0.5 in max | 0.376 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Shear plate weld to HSS | 19 kip | 72.042 kip | 0.264 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| HSS-Wandstanzung | 19 kip | 175.14 kip | 0.108 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
Die Verbindung besteht jede Prüfung. The two ratios at 1.000 are detailing limits that the layout meets exactly. Von den Festigkeitskontrollen, the flange bolts in slip govern at 0.944, followed closely by the flange plate weld to the HSS face at 0.937. The weld is limited by the HSS: nur 2.883 in der 6.5 in plate counts as effective width, and the weld length is capped at the 2.875 in workable flat of the 4 in face.
Was ist zu ändern, wenn eine Prüfung fehlschlägt?
- Flange bolts in slip: add bolts along the beam, Verwenden Sie eine größere Schraube, or a Class B faying surface. A deeper beam lowers the flange force for the same moment.
- Flange plate weld to the HSS: a thicker HSS wall raises Be, since Be grows with the square of the wall thickness, and a wider tube face gives a longer workable flat. A thicker flange plate lowers Be, so do not thicken the plate to fix this check.
- Flange plate local yielding or HSS sidewall yielding: use a thicker-walled tube.
- Beam flange tension rupture or flexural rupture: reduce the holes in the flange or use a heavier beam.
- Block shear or plate tension: increase the edge distances, the bolt spacing or the plate thickness.
- Shear plate checks: as for a shear tab, add a bolt row or make the plate deeper.
Auto Design is available for the flange plate moment connection to an HSS column. Es wechselt die Schrauben, plates and welds until every check passes, und behält Ihre Mitglieder und Lasten wie eingegeben bei. Siehe die Autodesign Seite für die Einstellungen, mit denen es funktioniert.
Häufig gestellte Fragen
How is this different from a flange plate connection to a W-shape column?
The beam side checks, Schritte 1 zu 10, are the same as in So entwerfen Sie eine Flanschplatten-Momentverbindung. The difference is at the column. On a W-shape column the plates weld to a thick flange backed by the column web. An HSS face is a thin wall between the corners, so the flange plate is reduced to an effective width for the weld and for plate local yielding, and the tube sidewalls are checked for local yielding.
Warum ist das 6.5 in flange plate wider than the 4 in HSS face?
The plate is sized to bolt to the 7.5 in beam flange at a 3.625 im Messgerät, which needs more width than the tube face has. The report allows a plate wider than the face, but only the 4 in over the face counts when the force goes into the HSS.
What is the effective width Be?
Gl. K1-1 reduces a plate welded across an HSS face to the width that is effective in carrying load into the wall. It depends on the wall slenderness b/t and on the ratio of wall to plate strength and thickness. Here Be = 2.883 in der 4 in effective plate width.
Why is the flange force 59.162 kip?
Das 38 kip-ft moment is divided by the distance between flange centers, 17.43 im, geben 26.162 kip, and half of the 66 kip axial force is added to each flange. The report uses this one flange force for every check in the flange plate section.
Does this example follow the AISC 15th or 16th edition Manual?
Es folgt AISC 360-16 with the AISC Manual 15th Edition and AISC Design Guide 24 for the HSS plate local yielding factor. Clause and page references move in the 16th Edition Manual and AISC 360-22, Vergleichen Sie sie daher mit der Edition, die Ihr Projekt verwendet.
Design a flange plate moment connection to an HSS column for free
Jede Zahl auf dieser Seite stammt aus einer Lösung. Pick the flange plate moment connection to an HSS column, Betreten Sie Ihren Strahl, Rohr, Platten, Schrauben und Lasten, und sehen Sie sich jede dieser Prüfungen in Ihrem Browser an. Es gibt nichts zu installieren.
Das SkyCiv Connection Design-Modul ist die Verbindungsdesign-Software hinter diesem Beispiel. Sie erhalten den vollständigen Berechnungsbericht mit jeder Gleichung und Ihren darin enthaltenen Zahlen, wie die Schritte oben, plus jede Kapazität und DCR, für AISC 360-22 und AISC 360-16 (LRFD und ASD) und AS 4100:2020. Das Schraubenrechner und Schweißrechner decken die Schraubengruppe und die Schweißnahtprüfungen selbstständig ab.
Quellen
- AISC 360-16, Spezifikation für Baustahlgebäude: D3 (Tabelle D3.1), F13.1 (Gl. F13-1), J2.4 (Gl. J2-4), J3.3, J3.4 (Tabelle J3.4), J3.6 (Gl. J3-1) und Kommentar, J3.8 (Gl. J3-4), J3.10 (Gl. J3-6a, J3-6c), J4.1 (Gl. J4-1, J4-2), J4.2 (Gl. J4-3, J4-4), J4.3 (Gl. J4-5), J4.4 (Gl. J4-6), J5.2(ein), K1 (Gl. K1-1, K1-2), K5.
- AISC-Stahlkonstruktionshandbuch, 15th Edition: Teil 9, Gl. 9-2; Teil 10, Gl. 10-7b (seite 10-153).
- AISC Design Guide 24, Hollow Structural Section Connections: Tabelle 7-2.
- So entwerfen Sie eine Flanschplatten-Momentverbindung (W-förmige Säule)
- So entwerfen Sie eine Einzelplatten-Scherverbindung
- Entwurf von Stahlverbindungen mit AISC 360-16
Harold Munalem
Produktmanager, Connection Design
10+ Jahre in der Stahlanschlussbemessung
LinkedIn