SkyCiv-Dokumentation

Ihr Leitfaden zur SkyCiv-Software – Tutorials, Anleitungen und technische Artikel

Flanschplatten-Momentverbindung zur HSS-Säulenkonstruktion

To design a bolted flange plate moment connection to a rectangular HSS column to AISC 360-16, you turn the beam moment into a tension and compression force in each flange, Überprüfen Sie die Flanschplatten, bolts and beam flanges for that force, and then check what the force does to the tube: the weld to the HSS face, local yielding of the plate on a flexible wall, and local yielding of the HSS sidewalls. A single plate on the beam web carries the shear.

This page works through one example: a W18x50 beam framing into the 4 in face of an HSS8x4x1/2 column, mit 38 Kip-ft-Moment, 19 Kip-Schere und 66 kip axial under LRFD, 3/4 in Grade 50 flange plates on four 1 jeweils in A490-SC-Schrauben, und ein 3/8 in A36 shear plate. Jede Gleichung wird mit ihren Zahlen ausgeschrieben, in der gleichen Reihenfolge wie das Berechnungsblatt SkyCiv Connection Design Modul produziert dafür.

What is a flange plate moment connection to an HSS column?

A flange plate Momentenanschluss has one plate on the top flange and one on the bottom flange of the beam. Each plate is shop-welded to the column and field-bolted to the beam flange, so the moment passes through the plates as a tension and compression couple. A shear plate on the web takes the beam reaction. For a W-shape column the plates weld to the column flange, as in So entwerfen Sie eine Flanschplatten-Momentverbindung.

On an HSS column the plates weld straight onto the tube wall, which is much more flexible than a column flange. A plate pulling on the middle of a thin wall cannot spread its force evenly across its width, so AISC reduces the plate to an effective width, and the sidewalls of the tube are checked for the force coming in from the corners. Those HSS checks are the part of the design this page adds to the W-shape example.

You can run this connection in the Rechner für Flanschplattenverbindungen.

Elevation: W18x50 beam with bolted top and bottom flange plates and a shear plate, welded to an HSS8x4x1/2 column

Höhe der Beispielverbindung. The flange plates are welded to the HSS face and bolted to the beam flanges; the shear plate carries the reaction.

Plan section A-A of the 3/4 in x 6 1/2 in flange plate with four 1 in A490-SC-Schrauben, welded to the 4 in HSS face

Abschnitt A-A, a plan cut through the top flange plate, showing the four bolts at a 3 5/8 in gage and the plate against the 4 in HSS face.

3D view of the flange plate moment connection: W18x50 beam framing into a rectangular HSS8x4x1/2 column

3D-Ansicht der Verbindung im SkyCiv Connection Design.

How do you design a flange plate moment connection to an HSS column? Die Schritte auf einen Blick

The report has two sections: the flange plates (Schritte 1 zu 14) and the shear plate (Schritte 15 zu 24).

  1. Detaillierungsgrenzen am Trägerflansch.
  2. Flange bolts in slip under the flange force.
  3. Bolt bearing on the flange plate.
  4. Bolt bearing on the beam flange.
  5. Blockscherung der Flanschplatte.
  6. Blockschub des Trägerflansches.
  7. Spannungsnachgeben und Bruch der Flanschplatte.
  8. Tension rupture of the beam flange.
  9. Biegebruch des Trägers an den Flanschschraubenlöchern.
  10. Compression of the flange plate.
  11. Detailing limit at the HSS face.
  12. Fillet weld from the flange plate to the HSS face.
  13. Local yielding of the flange plate on the HSS wall.
  14. Local yielding of the HSS sidewalls.
  15. Detailing limits of the shear plate at the beam.
  16. Shear plate bolt group.
  17. Bearing on the shear plate.
  18. Auflage auf dem Balkensteg.
  19. Effektive Stärke der Stegbolzengruppe.
  20. Block shear of the shear plate.
  21. Shear yielding and rupture of the shear plate.
  22. Detailing limits of the shear plate at the HSS wall.
  23. Weld from the shear plate to the HSS wall.
  24. HSS-Wandstanzung.

Designeingaben für dieses Beispiel

Der Designcode ist AISC 360-16 LRFD. Abschnittseigenschaften stammen aus dem AISC-Handbuch. How the loads are entered is explained in Lasten und Lastkombinationen.

ArtikelSymbolWert
Factored moment (starke Achse)[mathin] M_{ux} [mathin]38 kip-ft
Faktorisierte Scherung[mathin] V_{u} [mathin]19 kip
Faktorisierte Axialspannung / Druck-[mathin] T_{u},\ C_{u} [mathin]66 kip / 66 kip
BeamB18x50, ASTM A992
Strahltiefe / Bahndicke[mathin] d_{bm},\ t_{wb} [mathin]18 im / 0.355 im
Breite des Trägerflansches / Dicke[mathin] b_{fb},\ t_{fb} [mathin]7.5 im / 0.57 im
Strahlbereich / Ertrag / Zugfestigkeit[mathin] A,\ F_{yb},\ F_{ub} [mathin]14.7 in² / 50 ksi / 65 ksi
SpalteHSS8x4x1/2, ASTM A500 Gr. C.
Width of the HSS face the plates weld to[mathin] b [mathin]4 im
HSS-Tiefe / Designwandstärke[mathin] h,\ t [mathin]8 im / 0.465 im
Workable flat of the face[mathin] W_{flat} [mathin]2.875 im
Säulenertrag / Zugfestigkeit[mathin] F_{ys},\ F_{us} [mathin]50 ksi / 62 ksi
Flange plate itemSymbolWert
FlanschplattenPL 3/4 x 6 1/2 x 6 1/2, ASTM A572 Gr. 50 (50 / 65 ksi)
Plattenbreite / Länge / Dicke[mathin] b_{fp},\ L_{fp},\ t_{fp} [mathin]6.5 im / 6.5 im / 0.75 im
Flanschschrauben1 im A490-SC, Klasse a, 1 Scherebene
LöcherFlanschplatte: übergroß (OVS). Trägerflansch: Standard (STD)
Bolzenlinien / Messgerät[mathin] n_{r},\ g_{a} [mathin]2 / 3.625 im
Bolts per line / Abstand[mathin] n_{c},\ s_{c} [mathin]2 / 3 im
Plattenrandabstände, über / entlang des Balkens[mathin] L_{ev\_fp},\ L_{eh\_fp} [mathin]1.4375 im / 1.5 im
Beam flange edge distances, über / along[mathin] L_{ev\_bf},\ L_{eh\_bf} [mathin]1.9375 im / 1.5 im
Erection gap1/4 im
Weld to HSS face1/2 im Filet, E70XX
Shear plate itemSymbolWert
Shear platePL 3/8 x 3 1/2 x 9, ASTM A36 (36 / 58 ksi)
Stegbolzen1 im A490-N, Threads enthalten
LöcherTeller: horizontal kurzgeschlitzt (HSSL). Balkennetz: Standard (STD)
Bolzenreihen / Abstand / Stützen[mathin] n_{r},\ s_{r},\ n_{c} [mathin]3 / 3 im / 1
Edge distances / weld to bolt line[mathin] L_{e},\ a [mathin]1.5 im / 2 im
Weld to HSS face3/16 beidseitig filetieren, E70XX

Flange plate section

Schritt 1: Detaillierungsgrenzen am Trägerflansch (AISC 360-16 J3.3, J3.4)

The bolt gage across the flange, the spacing along it and the edge distances on both the plate and the beam flange are checked against the J3.3 and Table J3.4 limits for a 1 im Bolzen, with the oversized-hole increment on the plate.

DetaillierungslimitLimit (im)Tatsächlich (im)DCRErgebnis
Mindeststärke3.6253.6251.000Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Mindestabstand der Bolzensäulen2.6673.0000.889Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Maximaler Schraubenspaltenabstand6.0003.0000.500Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Minimaler vertikaler Randabstand der Platte1.3751.4380.956Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Minimaler horizontaler Randabstand der Platte1.3751.5000.917Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Minimaler vertikaler Randabstand des Trägerflansches1.2501.9380.645Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Minimaler horizontaler Randabstand des Trägerflansches1.2501.5000.833Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des

The gage equals the module’s minimum gage, so that row sits at exactly 1.000:

[math] DCR = \frac{3.625\,in}{3.625\,in} = 1.000 [math]

DCR = 1.000, in Ordnung

Schritt 2: Flange bolts in slip under the flange force (AISC 360-16 J3.8)

The moment becomes a force in each flange over the distance between flange centers, and half the axial force is added to it:

[math] P_{uF} = \frac{M_{ux}}{d_{bm} – t_{fb}} + \frac{P_{u}}{2} = \frac{38\,kip\text{-}ft}{18\,in – 0.57\,in} + \frac{66\,kip}{2} = 59.162\,kip [math]

This flange force is the demand for every check in the flange plate section. The four bolts are slip-critical, Gl. J3-4, with the report’s filler factor of 0.85:

[math] \phi R_{n} = \phi\, \mu\, D_{u}\, h_{f}\, T_{b}\, N_{s}\, n_{r}\, n_{c} = (0.85) \times (0.3) \times (1.13) \times (0.85) \times (64\,kip) \times (1) \times (2) \times (2) = 62.701\,kip [math]

DCR = 59.162 kip / 62.701 kip = 0.944 < 1.0, in Ordnung

Schritt 3: Bolt bearing on the flange plate (AISC 360-16 J3.10)

The force runs along the beam, so the bolts bear toward the plate end. Mit dem 1.25 in oversized hole:

[math] l_{c1} = 1.5 – \frac{1.25}{2} = 0.875\,in, \qquad l_{c2} = 3 – 1.25 = 1.75\,in [math]

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.875, 2.4) \times 0.75 \times 65 \times 2 + \min(1.2 \times 1.75, 2.4) \times 0.75 \times 65 \times 2 \times 1 \right] = 230.34\,kip [math]

DCR = 59.162 kip / 230.34 kip = 0.257 < 1.0, in Ordnung

Schritt 4: Bolt bearing on the beam flange (AISC 360-16 J3.10)

[math] l_{c1} = 1.5 – \frac{1.125}{2} = 0.9375\,in, \qquad l_{c2} = 1.875\,in [math]

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.57 \times 65 \times 2 + \min(1.2 \times 1.875, 2.4) \times 0.57 \times 65 \times 2 \times 1 \right] = 187.57\,kip [math]

DCR = 59.162 kip / 187.57 kip = 0.315 < 1.0, in Ordnung

Schritt 5: Blockscherung der Flanschplatte (AISC 360-16 J4.3)

Three tear-out shapes are checked, all with [mathin] U_{bs} = 1 [mathin] und Gl. J4-5:

[math] \phi R_{n} = \phi \left( 0.6 F_{up} A_{nv} + U_{bs} F_{up} A_{nt} \le 0.6 F_{yp} A_{gv} + U_{bs} F_{up} A_{nt} \right) [math]

MusterAgv (in²)Anv (in²)Ant (in²)phi Rn (kip)
L.: eine Scherebene, Spannung über die Schrauben bis zu einer Kante3.3751.89842.3203168.64
U.: zwei Scherebenen, Spannung zwischen den Bolzenlinien6.753.79691.7344195.61
2L.: zwei Scherebenen, Spannung von jeder Schraubenlinie bis zum Rand6.753.79691.1719168.19

For the governing 2L pattern:

[math] A_{nt} = 2 \times 0.75 \left[ 1.4375 – 0.5 \times (1.25 + 0.0625) \right] = 1.1719\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.7969 + 65 \times 1.1719 \le 0.6 \times 50 \times 6.75 + 65 \times 1.1719 \right) = 168.19\,kip [math]

DCR = 59.162 kip / 168.19 kip = 0.352 < 1.0, in Ordnung

Schritt 6: Blockschub des Trägerflansches (AISC 360-16 J4.3)

The beam flange tears out as two outer strips:

[math] A_{nt} = 0.57 \left[ 7.5 – 3.625 – 1 \times (1.1875) \right] = 1.5319\,in^{2} [math]

[math] A_{gv} = 2 \times 0.57 \left[ 1.5 + 3 \right] = 5.13\,in^{2}, \qquad A_{nv} = 2 \times 0.57 \left( 4.5 – 1.5 \times 1.1875 \right) = 3.0994\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 65 \times 3.0994 + 65 \times 1.5319 \le 0.6 \times 50 \times 5.13 + 65 \times 1.5319 \right) = 165.34\,kip [math]

DCR = 59.162 kip / 165.34 kip = 0.358 < 1.0, in Ordnung

Schritt 7: Spannungsnachgeben und Bruch der Flanschplatte (AISC 360-16 J4.1)

[math] \phi R_{n\_ty} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]

[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.75 \left[ 6.5 – 2 \times (1.3125) \right] = 141.68\,kip [math]

DCR = 59.162 kip / 141.68 kip = 0.418 < 1.0, in Ordnung

Schritt 8: Tension rupture of the beam flange (AISC 360-16 D3, J4.1)

The flange force is taken by half the beam’s area, less the two flange holes, with the shear lag factor U = 0.283 from Table D3.1 case 2:

[math] \phi R_{n\_tr} = 0.75 \times 65 \times 0.283 \left[ 0.5 \times 14.7 – 2 \times (1.1875) \times 0.57 \right] = 82.726\,kip [math]

DCR = 59.162 kip / 82.726 kip = 0.715 < 1.0, in Ordnung

Schritt 9: Biegebruch des Trägers an den Flanschschraubenlöchern (AISC 360-16 F13.1)

[math] A_{fg} = 7.5 \times 0.57 = 4.275\,in^{2}, \qquad A_{fn} = 4.275 – 2 \times (1.1875) \times 0.57 = 2.9213\,in^{2} [math]

With Fy / Fu = 0.76923, nicht mehr als 0.8, Yt = 1. Dann:

[math] F_{u} A_{fn} = 189.88\,kip \lt Y_{t} F_{y} A_{fg} = 213.75\,kip [math]

so the holes reduce the flexural strength and Eq. F13-1 applies, with the beam’s elastic modulus of 89.005 in³:

[math] M_{n} = \frac{F_{ub} A_{fn}}{A_{fg}}\, S_{x} = \frac{65 \times 2.9213}{4.275} \times 89.005 = 329.44\,kip\text{-}ft [math]

[math] \phi R_{n} = \frac{0.9\, M_{n}}{d_{bm} – t_{fb}} = \frac{0.9 \times 329.44\,kip\text{-}ft}{18\,in – 0.57\,in} = 204.13\,kip [math]

DCR = 59.162 kip / 204.13 kip = 0.290 < 1.0, in Ordnung

Schritt 10: Compression of the flange plate (AISC 360-16 J4.4)

KL/r of the plate is no more than 25, also Gl. J4-6 applies with no buckling reduction:

[math] \phi R_{n} = 0.9 \times 50 \times 0.75 \times 6.5 = 219.38\,kip [math]

DCR = 59.162 kip / 219.38 kip = 0.270 < 1.0, in Ordnung

Schritt 11: Detailing limit at the HSS face

DetaillierungslimitLimit (im)Tatsächlich (im)DCRErgebnis
Maximale Kehlnahtgröße pro Trägerabstand0.5000.5001.000Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des

Das 1/2 in weld exactly fills the available clearance, was erlaubt ist:

DCR = 1.000, in Ordnung

Schritt 12: Fillet weld from the flange plate to the HSS face (AISC 360-16 K1, K5, J2.4)

This is where the HSS changes the design. The base metal limit first, from Manual Eq. 9-2:

[math] D_{max} = \frac{(0.375)(65) \le (0.465)(62)}{3.09} = 7.8883 [math]

Das 6.5 in der Platte ist breiter als die 4 in HSS face. The report allows that, but only the width over the face delivers load into it:

[math] B_{p,eff} = b_{fp} \le b = \min(6.5\,in, 4\,in) = 4\,in [math]

Gl. K1-1 then reduces it to the effective width:

[math] B_{e} = \left( \frac{10 t}{b} \right) \left( \frac{F_{ys}\, t}{F_{yp}\, t_{fp}} \right) B_{p,eff} \le B_{p,eff} = \left( \frac{10 \times 0.465}{4} \right) \left( \frac{50 \times 0.465}{50 \times 0.75} \right) \times 4 = 2.883\,in [math]

Per K5 the effective weld length is 2Be, and the report also caps Be at the workable flat:

[math] L_{w} = 2 \left( B_{e} \le W_{flat} \right) = 2 \times \min(2.883, 2.875) = 5.75\,in [math]

[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.5, \frac{7.8883}{16}\right) \times 5.75 = 63.144\,kip [math]

DCR = 59.162 kip / 63.144 kip = 0.937 < 1.0, in Ordnung

Schritt 13: Local yielding of the flange plate on the HSS wall (AISC 360-16 K1, Bemessungsleitfaden 24)

The same effective width idea limits the force the plate can deliver into the wall. The report uses φ = 0.95 from AISC Design Guide 24, Tabelle 7-2:

[math] \phi R_{n} = \phi \left( \frac{10\, t^{2}\, F_{ys}\, B_{p,eff}}{b} \le F_{yp}\, t_{fp}\, B_{p,eff} \right) = 0.95 \times \min\left( \frac{10 \times 0.465^{2} \times 50 \times 4}{4},\; 50 \times 0.75 \times 4 \right) = 102.71\,kip [math]

DCR = 59.162 kip / 102.71 kip = 0.576 < 1.0, in Ordnung

Schritt 14: Local yielding of the HSS sidewalls

The flange force also reaches the two sidewalls of the tube through the corners. The report checks them with the expression below and φ = 1.0, without citing a clause, so it is the software’s limit for this check:

[math] \phi R_{n} = \phi \times 2 F_{ys}\, t \left[ 5 (1.5 t) + t_{fp} \right] = 1.0 \times 2 \times 50 \times 0.465 \left[ 5 \times (1.5 \times 0.465) + 0.75 \right] = 197.04\,kip [math]

DCR = 59.162 kip / 197.04 kip = 0.300 < 1.0, in Ordnung

Shear plate section

The shear plate is a conventional single plate welded to the HSS face and carries the 19 Kippreaktion. Its checks follow the shear tab procedure, worked in full in So entwerfen Sie eine Einzelplatten-Scherverbindung, with the HSS face checks added.

Schritt 15: Detailing limits of the shear plate at the beam (AISC 360-16 J3.3, J3.4)

DetaillierungslimitLimit (im)Tatsächlich (im)DCRErgebnis
Mindestabstand der Schraubenreihen2.6673.0000.889Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Maximaler Schraubenreihenabstand6.0003.0000.500Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Minimaler vertikaler Randabstand der Platte1.2501.5000.833Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Minimaler horizontaler Randabstand der Platte1.3751.5000.917Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Minimaler horizontaler Randabstand des Strahls1.2501.5000.833Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Mindestverbindungstiefe7.7509.0000.861Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Maximale Verbindungstiefe16.0009.0000.563Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des

[math] DCR = \frac{1.375\,in}{1.5\,in} = 0.917 [math]

DCR = 0.917 < 1.0, in Ordnung

Schritt 16: Shear plate bolt group (AISC 360-16 J3.6)

No fillers, Also [mathin] h_{f} = 1 [mathin] by J5.2(ein). The report uses C = 3 for the three web bolts:

[math] \phi R_{n} = 0.75 \times 68 \times \frac{\pi}{4} (1\,in)^{2} \times (1) \times (3) \times (1) = 120.17\,kip [math]

DCR = 19 kip / 120.17 kip = 0.158 < 1.0, in Ordnung

Schritt 17: Bearing and tear-out on the shear plate (AISC 360-16 J3.10)

[math] \phi R_{n} = (0.75) \left[ \min(1.2 \times 0.9375, 2.4) \times 0.375 \times 58 + \min(1.2 \times 1.875, 2.4) \times 0.375 \times 58 \times 2 \right] \times \frac{3}{3} = 91.758\,kip [math]

DCR = 19 kip / 91.758 kip = 0.207 < 1.0, in Ordnung

Schritt 18: Bearing and tear-out on the beam web (AISC 360-16 J3.10)

[math] \phi R_{n} = (0.75) \times \min(1.2 \times 1.875, 2.4) \times (0.355\,in) \times (65\,ksi) \times (3) = 116.82\,kip [math]

DCR = 19 kip / 116.82 kip = 0.163 < 1.0, in Ordnung

Schritt 19: Effektive Stärke der Stegbolzengruppe (AISC 360-16 J3.6 Kommentar)

Pro Bolzen: Schub- 40.055 kip, plate edge bolt 18.352 kip, plate inner bolt 36.703 kip and beam web 38.939 kip. Schrauben 1 und 2 take the inner-bolt value and bolt 3 the edge value:

[math] \Sigma \phi r_{eff} = 2 \times (36.703\,kip) + 18.352\,kip = 91.758\,kip, \qquad \phi R_{n,eff} = 91.758 \times \frac{3}{3} = 91.758\,kip [math]

DCR = 19 kip / 91.758 kip = 0.207 < 1.0, in Ordnung

Schritt 20: Block shear of the shear plate (AISC 360-16 J4.3)

[math] A_{nt} = 0.30469\,in^{2}, \quad A_{gv} = 2.8125\,in^{2}, \quad A_{nv} = 1.6992\,in^{2} [math]

[math] \phi R_{n} = 0.75 \left( 0.6 \times 58 \times 1.6992 + 58 \times 0.30469 \le 0.6 \times 36 \times 2.8125 + 58 \times 0.30469 \right) = 57.604\,kip [math]

DCR = 19 kip / 57.604 kip = 0.330 < 1.0, in Ordnung

Schritt 21: Shear yielding and rupture of the shear plate (AISC 360-16 J4.2)

[math] \phi R_{n\_sy} = 1.0 \times 0.6 \times 36 \times 3.375 = 72.9\,kip, \qquad \phi R_{n\_sr} = 0.75 \times 0.6 \times 58 \times 2.0391 = 53.22\,kip [math]

DCR = 19 kip / 53.22 kip = 0.357 < 1.0, in Ordnung

Schritt 22: Detailing limits of the shear plate at the HSS wall

Die Bearbeitbarkeits- und Schlankheitswerte sind die Modulgrenzen für eine einzelne Platte an einer HSS-Wand.

DetaillierungslimitLimit (im)Tatsächlich (im)DCRErgebnis
Maximale Kehlnahtgröße pro Trägerabstand0.5000.1880.376Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Maximale Kehlnahtgröße pro HSS-bearbeitbarer Fläche0.8850.1880.212Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Maximale HSS-Wandschlankheit b/t33.7165.6020.166Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des

DCR = 0.376 < 1.0, in Ordnung

Schritt 23: Weld from the shear plate to the HSS wall (AISC 360-16 J2.4)

[math] D_{max} = \frac{(0.1875)(58) \le (0.465)(62)}{3.09} = 3.5194, \qquad L_{w} = 2 \left[ 9 – 2 \times 0.1875 \right] = 17.25\,in [math]

[math] \phi R_{n} = 0.75 \times 0.6 \times 70 \times \frac{\sqrt{2}}{2} \times \min\left(0.1875, \frac{3.5194}{16}\right) \times \left[ 1 + 0.5 \sin^{1.5}(0) \right] \times 17.25 = 72.042\,kip [math]

DCR = 19 kip / 72.042 kip = 0.264 < 1.0, in Ordnung

Schritt 24: HSS-Wandstanzung (AISC-Handbuch Gl. 10-7b, seite 10-153)

[math] \phi R_{n} = \frac{0.75 \times 62 \times 0.465 \times 9^{2}}{5 \times 2} = 175.14\,kip [math]

DCR = 19 kip / 175.14 kip = 0.108 < 1.0, in Ordnung

Zusammenfassung der Designprüfungen

Design-CheckNachfrageDie SkyCiv Foundation umfasst das Design von isolierten Fundamenten, die den australischen Standards¹ entsprechenDCRErgebnis
Flansch: detailing at beam3.625 im Messgerät3.625 in min1.000Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Flange bolts in slip59.162 kip62.701 kip0.944Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Lager auf Flanschplatte59.162 kip230.34 kip0.257Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Lager am Trägerflansch59.162 kip187.57 kip0.315Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Blockschere, Flanschplatte59.162 kip168.19 kip0.352Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Blockschere, Trägerflansch59.162 kip165.34 kip0.358Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Spannung der Flanschplatte59.162 kip141.68 kip0.418Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Beam flange tension rupture59.162 kip82.726 kip0.715Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Beam flexural rupture at holes59.162 kip204.13 kip0.290Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Kompression der Flanschplatte59.162 kip219.38 kip0.270Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Flansch: detailing at HSS face0.5 in Schweißnaht0.5 in max1.000Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Flange plate weld to HSS59.162 kip63.144 kip0.937Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Flange plate local yielding59.162 kip102.71 kip0.576Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
HSS sidewall local yielding59.162 kip197.04 kip0.300Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Shear plate: detailing at beam1.375 in min1.5 in edge0.917Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Shear plate bolt group19 kip120.17 kip0.158Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Bearing on shear plate19 kip91.758 kip0.207Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Lager am Trägersteg19 kip116.82 kip0.163Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Effective web bolt group strength19 kip91.758 kip0.207Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Blockschere, shear plate19 kip57.604 kip0.330Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Schernachgeben und Bruch, shear plate19 kip53.22 kip0.357Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Shear plate: detailing at HSS wall0.188 in Schweißnaht0.5 in max0.376Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
Shear plate weld to HSS19 kip72.042 kip0.264Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des
HSS-Wandstanzung19 kip175.14 kip0.108Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des

Die Verbindung besteht jede Prüfung. The two ratios at 1.000 are detailing limits that the layout meets exactly. Von den Festigkeitskontrollen, the flange bolts in slip govern at 0.944, followed closely by the flange plate weld to the HSS face at 0.937. The weld is limited by the HSS: nur 2.883 in der 6.5 in plate counts as effective width, and the weld length is capped at the 2.875 in workable flat of the 4 in face.

Was ist zu ändern, wenn eine Prüfung fehlschlägt?

  • Flange bolts in slip: add bolts along the beam, Verwenden Sie eine größere Schraube, or a Class B faying surface. A deeper beam lowers the flange force for the same moment.
  • Flange plate weld to the HSS: a thicker HSS wall raises Be, since Be grows with the square of the wall thickness, and a wider tube face gives a longer workable flat. A thicker flange plate lowers Be, so do not thicken the plate to fix this check.
  • Flange plate local yielding or HSS sidewall yielding: use a thicker-walled tube.
  • Beam flange tension rupture or flexural rupture: reduce the holes in the flange or use a heavier beam.
  • Block shear or plate tension: increase the edge distances, the bolt spacing or the plate thickness.
  • Shear plate checks: as for a shear tab, add a bolt row or make the plate deeper.

Auto Design is available for the flange plate moment connection to an HSS column. Es wechselt die Schrauben, plates and welds until every check passes, und behält Ihre Mitglieder und Lasten wie eingegeben bei. Siehe die Autodesign Seite für die Einstellungen, mit denen es funktioniert.

Häufig gestellte Fragen

How is this different from a flange plate connection to a W-shape column?

The beam side checks, Schritte 1 zu 10, are the same as in So entwerfen Sie eine Flanschplatten-Momentverbindung. The difference is at the column. On a W-shape column the plates weld to a thick flange backed by the column web. An HSS face is a thin wall between the corners, so the flange plate is reduced to an effective width for the weld and for plate local yielding, and the tube sidewalls are checked for local yielding.

Warum ist das 6.5 in flange plate wider than the 4 in HSS face?

The plate is sized to bolt to the 7.5 in beam flange at a 3.625 im Messgerät, which needs more width than the tube face has. The report allows a plate wider than the face, but only the 4 in over the face counts when the force goes into the HSS.

What is the effective width Be?

Gl. K1-1 reduces a plate welded across an HSS face to the width that is effective in carrying load into the wall. It depends on the wall slenderness b/t and on the ratio of wall to plate strength and thickness. Here Be = 2.883 in der 4 in effective plate width.

Why is the flange force 59.162 kip?

Das 38 kip-ft moment is divided by the distance between flange centers, 17.43 im, geben 26.162 kip, and half of the 66 kip axial force is added to each flange. The report uses this one flange force for every check in the flange plate section.

Does this example follow the AISC 15th or 16th edition Manual?

Es folgt AISC 360-16 with the AISC Manual 15th Edition and AISC Design Guide 24 for the HSS plate local yielding factor. Clause and page references move in the 16th Edition Manual and AISC 360-22, Vergleichen Sie sie daher mit der Edition, die Ihr Projekt verwendet.

Design a flange plate moment connection to an HSS column for free

Jede Zahl auf dieser Seite stammt aus einer Lösung. Pick the flange plate moment connection to an HSS column, Betreten Sie Ihren Strahl, Rohr, Platten, Schrauben und Lasten, und sehen Sie sich jede dieser Prüfungen in Ihrem Browser an. Es gibt nichts zu installieren.

Das SkyCiv Connection Design-Modul ist die Verbindungsdesign-Software hinter diesem Beispiel. Sie erhalten den vollständigen Berechnungsbericht mit jeder Gleichung und Ihren darin enthaltenen Zahlen, wie die Schritte oben, plus jede Kapazität und DCR, für AISC 360-22 und AISC 360-16 (LRFD und ASD) und AS 4100:2020. Das Schraubenrechner und Schweißrechner decken die Schraubengruppe und die Schweißnahtprüfungen selbstständig ab.

Quellen

Harold Munalem, Produktmanager für SkyCiv Connection Design

Harold Munalem
Produktmanager, Connection Design
10+ Jahre in der Stahlanschlussbemessung
LinkedIn

Wie können wir helfen?

×

Nach oben