To design a directly welded web connection between two channels to AISC 360, you check the fillet welds that join the beam web to the girder web against the beam end reaction. There is no plate and there are no bolts, so the design comes down to two things: a weld group that fits on the flat of the beam web and is at least the minimum size, and a weld that is strong enough once the base metal on both sides of it is accounted for.
Auf dieser Seite wird ein Beispiel von Anfang bis Ende durchgearbeitet: a C10x20 beam framing into the back of a C15x50 girder channel, mit einem 25 kip LRFD reaction carried by 1/4 in E70XX fillet welds on both sides of the beam web, Entwickelt für AISC 360-16 und das AISC-Handbuch, 15. Auflage. Jede Gleichung wird mit ihren Zahlen ausgeschrieben, in der gleichen Reihenfolge wie das AISC-Berechnungsblatt SkyCiv Connection Design Modul produziert dafür.
What is a channel to channel directly welded web connection?
It is a shear connection in which the end of a channel beam is welded straight to a channel girder, with no connecting element in between. The beam web butts against the girder and a fillet weld runs down each side of the beam web. It suits shop-assembled frames, platforms and secondary framing where channels are used for both members and a bolted field joint is not needed.
In diesem Beispiel wird die BBC-Ausrichtung verwendet, Strahl zur Rückseite des Kanals. The beam frames to the flat back of the girder’s web, auf der von den Flanschen abgewandten Seite, so the beam needs no cope to clear them. Die andere Ausrichtung, BFC (Strahl zur Vorderseite des Kanals), legt den Balken zwischen die Flansche des Trägers.

Höhe aus dem Berechnungsbericht: C10x20 beam welded to the back of a C15x50 girder channel

3D-Ansicht der Verbindung im SkyCiv Connection Design
Direkt verschweißte Stegverbindungskonstruktion: Die Schritte auf einen Blick
- Detaillierungsgrenzen: check the minimum fillet weld size and that the welded depth fits on the flat of the beam web.
- Schweißfestigkeit: find the largest weld the base metal can develop, the effective weld length, and the design strength of the two fillet welds.
Designeingaben für dieses Beispiel
| Artikel | Symbol | Wert |
|---|---|---|
| Erforderliche Scherfestigkeit (LRFD) | [mathin] V_{u} [mathin] | 25 kip |
| Beam | C10x20, ASTM A36 | |
| Strahltiefe / Bahndicke | [mathin] d_{bm},\ t_{wb} [mathin] | 10 im / 0.379 im |
| Breite des Trägerflansches / Dicke | [mathin] b_{fb},\ t_{fb} [mathin] | 2.74 im / 0.436 im |
| Strahlbereich | [mathin] A_{bm} [mathin] | 10 in² |
| Strahlausbeute / Zugspannung | [mathin] F_{yb},\ F_{ub} [mathin] | 36 ksi / 58 ksi |
| Träger | C15x50, ASTM A36 | |
| Trägertiefe / Bahndicke | [mathin] d_{sup},\ t_{ws} [mathin] | 15 im / 0.716 im |
| Trägerflanschbreite / Dicke | [mathin] b_{fs},\ t_{fs} [mathin] | 3.72 im / 0.65 im |
| Trägerbereich | [mathin] A_{sup} [mathin] | 14.7 in² |
| Trägerausbeute / Zugspannung | [mathin] F_{ys},\ F_{us} [mathin] | 36 ksi / 58 ksi |
| Elastizitätsmodul | [mathin] E [mathin] | 29000 ksi |
| Schweißen | Symbol | Wert |
|---|---|---|
| Elektrode | E70XX | |
| Filler metal classification strength | [mathin] F_{EXX} [mathin] | 70 ksi |
| Fillet weld size, both sides of the beam web | [mathin] W [mathin] | 1/4 im (0.25 im) |
| Welded depth | [mathin] L_{d} [mathin] | 8 im |
Schritt 1: Einschränkungen bei Verbindungsdetails (AISC 360-16 J2.2b)
The weld has to stay on the flat part of the beam web, clear of the flange-to-web fillets. The program takes the web lost at each flange as the larger of the design k distance and the cope depth. This beam has no copes, so each is 1 im.
[math] D_{max} = d_{det\_bm} – c_{t} – c_{b} = (10\ \text{in}) – (1\ \text{in}) – (1\ \text{in}) = 8\ \text{in} [math]
The welded depth of 8 in uses the full flat depth. The minimum fillet weld size of 3/16 in is the AISC 360-16 Table J2.4 value for the thinner part joined, der 0.379 im Balkensteg. Das 4 in minimum connection depth is the software’s limit.
| Detaillierungslimit | Limit (im) | Tatsächlich (im) | DCR | Ergebnis |
|---|---|---|---|---|
| Mindestgröße der Kehlnaht | 0.188 | 0.250 | 0.750 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Mindestverbindungstiefe | 4.000 | 8.000 | 0.500 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Maximale Verbindungstiefe | 8.000 | 8.000 | 1.000 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
DCR = 8 / 8 = 1.000 ≤ 1.0, in Ordnung
Schritt 2: Design capacity of the weld (AISC 360-16 J2.4)
Grundmetallbeschränkung für die Schweißnahtgröße (AISC-Handbuch Gl. 9-2)
A fillet weld can be no stronger than the metal it is fused to. On the girder side the weld sits on the 0.716 im Trägersteg. On the beam side the beam web carries a weld on each face, so each weld gets half of the 0.379 im Web, 0.1895 im. The smaller of the two products governs, expressed as a weld size in sixteenths of an inch:
[math] D_{max} = \frac{\min\left(t_{ws} F_{us},\ \frac{t_{wb}}{2} F_{ub}\right)}{3.09\ \text{kip/in} \times F_{EXX}/F_{E70XX}} = \frac{\min\left((0.716\ \text{in})(58\ \text{ksi}),\ (0.1895\ \text{in})(58\ \text{ksi})\right)}{(3.09\ \text{kip/in}) \times (1)} = 3.557 [math]
The beam web governs. A weld of 3.557 sixteenths is [mathin] 3.557/16 = 0.222 [mathin] im, which is smaller than the 1/4 in Schweißnaht, so the strength equation below uses the 0.222 in size the beam web can develop.
Effektive Schweißnahtlänge (AISC-Handbuch Teil 10)
Each of the two welds runs the 8 in welded depth, less two weld sizes for the ends:
[math] L_{w} = 2 \left[ L_{d} – 2W \right] = 2 \times \left[ (8\ \text{in}) – 2 \times (0.25\ \text{in}) \right] = 15\ \text{in} [math]
Schweißfestigkeit (Gl. J2-4)
Mit [mathin] \phi = 0.75 [mathin] and the load parallel to the welds ([mathin] \theta_{u} = 0 [mathin]):
[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left(W,\ \frac{D_{max}}{16}\right) \left[1 + 0.5 \left(\sin \theta_{u}\right)^{1.5}\right] L_{w} [math]
[math] \phi R_{n} = (0.75) \times 0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left(0.25\ \text{in},\ \frac{3.557}{16}\right) \times \left[1 + 0.5 \times (\sin 0)^{1.5}\right] \times (15\ \text{in}) = 74.275\ \text{kip} [math]
[math] V_{u} = 25\ \text{kip} \le \phi R_{n} = 74.275\ \text{kip} [math]
DCR = 25 kip / 74.275 kip = 0.337 ≤ 1.0, in Ordnung
Zusammenfassung der Schecks
| Überprüfen | Nachfrage | Die SkyCiv Foundation umfasst das Design von isolierten Fundamenten, die den australischen Standards¹ entsprechen | DCR | Ergebnis |
|---|---|---|---|---|
| Einschränkungen bei Verbindungsdetails | 8 im | 8 im | 1.000 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| **Design capacity of weld** | **25 pennen** | **74.275 pennen** | **0.337** | **PASSIEREN** |
The connection passes both checks. Das Detaillierungsverhältnis von 1.000 is not a strength ratio: it shows that the 8 in weld uses the whole flat of the C10x20 web, which is the most this beam allows. The weld is the governing strength check at 0.337, and its strength is limited by the thin beam web rather than by the 1/4 in weld itself.
Auto Design is available for the channel to channel directly welded web connection. Es ändert die Entwurfsvariablen der Verbindung, bis jede Prüfung erfolgreich ist, und behält Ihre Mitglieder und Lasten wie eingegeben bei. Siehe die Autodesign Seite für die Einstellungen, mit denen es funktioniert.
Was ist zu ändern, wenn eine Prüfung fehlschlägt?
- Maximale Verbindungstiefe: the welded depth cannot be more than the flat of the beam web, Hier 8 im. If you need more weld, use a deeper beam or a connection with a plate or angles.
- Mindestgröße der Kehlnaht: use at least the Table J2.4 minimum for the thinner part joined, Hier 3/16 im.
- Schweißfestigkeit: lengthen the weld up to the maximum depth first. A larger weld only helps until it reaches the base metal limit. In this example the beam web already limits the effective size to 0.222 im, also ein 5/16 in weld would add no strength. Past that point, use a beam with a thicker web or a connection with a plate or angles.
Häufig gestellte Fragen
Why is the effective weld size 0.222 in when the weld is 1/4 im?
AISC-Handbuch Gl. 9-2 limits the weld to what the base metal can develop in shear. Das Balkennetz ist 0.379 in thick and has a weld on each face, so each weld is matched against half of it. That half-web can only develop a weld of 3.557 Sechzehntel, 0.222 im, and the extra size of the 1/4 in weld is not counted.
Why is the weld length 15 in when the welded depth is 8 im?
There are two welds, eine auf jeder Seite des Balkenstegs. Each is 8 in long less two weld sizes for the ends, 7.5 im, so the total effective length is 15 im.
Was bedeutet BBC??
BBC wird hinter dem Kanal ausgestrahlt. The beam frames to the flat back of the girder channel’s web, weg von seinen Flanschen. Im BFC, Strahl zur Vorderseite des Kanals, die Balkenrahmen zwischen den Trägerflanschen.
Is the girder web checked?
The girder web enters the design through the base metal check of Step 2, where its 0.716 in thickness is compared with the beam web’s half thickness. In this example the beam web is the weaker of the two, so it sets the weld strength.
Wie würde sich dies für ASD anstelle von LRFD ändern??
Die Gleichungen sind die gleichen. The program uses the ASD safety factor in place of the LRFD resistance factor and compares the result with the ASD required strength.
Entwerfen Sie kostenlos eine direkt geschweißte Stegverbindung
Jede Zahl auf dieser Seite stammt aus einer Lösung. Pick the channel to channel category and the directly welded web configuration, Betreten Sie Ihren Strahl, Träger, Schweißen und Reaktion, und sehen Sie sich jede dieser Prüfungen in Ihrem Browser an. Es gibt nichts zu installieren.
Das SkyCiv Connection Design-Modul ist die Verbindungsdesign-Software hinter diesem Beispiel. Sie erhalten den vollständigen Berechnungsbericht mit jeder Gleichung und Ihren darin enthaltenen Zahlen, wie die Schritte oben, plus jede Kapazität und DCR, für AISC 360-22 und AISC 360-16 (LRFD und ASD) und AS 4100:2020. Das Schweißrechner covers the weld checks on their own.
Quellen
- AISC 360-16, Spezifikation für Baustahlgebäude: J2.2b (Tabelle J2.4), J2.4 (Gl. J2-4).
- AISC-Stahlkonstruktionshandbuch, 15th Edition: Teil 9, Gl. 9-2; Teil 10, effektive Schweißlänge.
- Entwurf von Stahlverbindungen mit AISC 360-16
- Schweißnähte im SkyCiv Connection Design
Harold Munalem
Produktmanager, Connection Design
10+ Jahre in der Stahlanschlussbemessung
LinkedIn