When a directly welded web connection carries an axial force as well as the end shear, two things change in the design to AISC 360. The welds now see a resultant force at an angle to their axis, which is larger than the shear alone but also earns the directional strength increase of Eq. J2-5. And the axial force is delivered to the column flange as a concentrated force, so the column has to be checked for flange local bending, web local yielding and, in Kompression, web local crippling.
This page works the same connection as the shear-only directly welded web example, a W18x50 beam web welded to the flange of a W14x90 column with 3/16 in E70XX-Kehlnähten 15.5 in long on both sides of the web, and adds an axial force of 132 kip in tension or compression to the 38 kip end shear (LRFD). Das Design ist AISC 360-16 und das AISC-Handbuch, 15. Auflage. Jede Gleichung wird mit ihren Zahlen ausgeschrieben, in der gleichen Reihenfolge wie das Berechnungsblatt, das die SkyCiv Connection Design Modul erzeugt für diese Verbindung.
What the axial force adds to a directly welded web connection
A beam in a braced frame or a diaphragm chord often carries an axial force along with its end reaction, for example as a strut or collector. With a directly welded web, that force has no plate or bolts to pass through: it goes straight from the web into the two fillet welds and from them into the column flange.
The member sizes, weld and the checks of the minimum weld size and the beam web in shear are the same as in the shear-only example, and give the same results. This page focuses on the weld under combined load and on the two support checks the axial force adds. The other shear connection types are on the Scherverbindungen seite.

Höhe der Beispielverbindung, mit dem 38 Kip-Schere und die 132 kip tension or compression at the beam end.

Die gleiche Verbindung im SkyCiv Connection Design, mit der Konfiguration „Directly Welded Web“ auf der Registerkarte „Assembly“..
Directly welded web shear and axial design: Die Schritte auf einen Blick
- Überprüfen Sie die Mindestgröße der Kehlnaht.
- Check the welds for the resultant of the shear and the axial force.
- Überprüfen Sie den Balkensteg auf Scherung.
- Check the column for the axial tension: flange local bending and web local yielding.
- Check the column for the axial compression: web local crippling and web local yielding.
Designeingaben für dieses Beispiel
Der Designcode ist AISC 360-16 LRFD. Abschnittseigenschaften stammen aus dem AISC-Handbuch. Die KDEs der Spalte, Wird im lokalen Web-Yielding verwendet, ist 1.31 im.
| Artikel | Symbol | Wert |
|---|---|---|
| Faktorisierte Scherung | [mathin] V_{u} [mathin] | 38 kip |
| Faktorisierte Axialspannung | [mathin] T_{u} [mathin] | 132 kip |
| Faktorisierte axiale Kompression | [mathin] C_{u} [mathin] | 132 kip |
| Beam | B18x50, A992 | |
| Strahltiefe / Bahndicke | [mathin] d_{bm},\ t_{wb} [mathin] | 18 im / 0.355 im |
| Spalte | B14x90, A992 | |
| Spaltentiefe / Bahndicke | [mathin] d_{sup},\ t_{ws} [mathin] | 14 im / 0.44 im |
| Breite des Stützenflansches / Dicke | [mathin] b_{fs},\ t_{fs} [mathin] | 14.5 im / 0.71 im |
| Spalte kdes | [mathin] k_{des} [mathin] | 1.31 im |
| Balken- und Stützenausbeute / Zugspannung | [mathin] F_{y},\ F_{u} [mathin] | 50 ksi / 65 ksi |
| Elastizitätsmodul | [mathin] E [mathin] | 29000 ksi |
| Schweißen | E70XX-Filet, beide Seiten des Webs | |
| Schweißnahtgröße / length on each side | [mathin] W,\ L_{wv} [mathin] | 0.1875 im / 15.5 im |
Schritt 1: Mindestgröße der Kehlnaht (AISC 360-16 J2.2b, Tabelle J2.4)
The axial force does not change this check. The thinner part joined is the 0.355 im Balkensteg, so the Table J2.4 minimum is 3/16 im, and the weld is 3/16 im.
DCR = 0.1875 im / 0.1875 im = 1.000 ≤ 1.0, in Ordnung
Schritt 2: Welds under the resultant of shear and axial force (AISC 360-16 J2.4)
The base metal limit and the effective length are the same as for shear alone, half the web thickness against the column flange, and twice the weld size off each end:
[math] D_{max} = \frac{\min\left( t_{fs} F_{us},\ \frac{t_{wb}}{2} F_{ub} \right)}{3.09\ \text{kip/in}} = \frac{\min\left( (0.71\ \text{in})(65\ \text{ksi}),\ (0.1775\ \text{in})(65\ \text{ksi}) \right)}{3.09\ \text{kip/in}} = 3.7338 [math]
[math] L_{w} = 2\left[ L_{wv} – 2W \right] = 2 \times \left[ 15.5\ \text{in} – 2 \times 0.1875\ \text{in} \right] = 30.25\ \text{in} [math]
What changes is the load. The welds now carry the vertical shear along their axis and the axial force across it. The demand is the resultant of the two, at an angle to the weld axis:
[math] R_{u} = \sqrt{V_{u}^{2} + T_{u}^{2}} = \sqrt{(38\ \text{kip})^{2} + (132\ \text{kip})^{2}} = 137.36\ \text{kip} [math]
[math] \theta_{u} = \tan^{-1}\left( \frac{T_{u}}{V_{u}} \right) = \tan^{-1}\left( \frac{132}{38} \right) = 73.94^{\circ} [math]
A fillet weld loaded across its axis is stronger than one loaded along it, und Gl. J2-5 rewards that with the directional term:
[math] \phi R_{n} = \phi\, 0.6\, F_{EXX} \frac{\sqrt{2}}{2} \min\left( W,\ \frac{D_{max}}{16} \right) \left[ 1 + 0.5 \left( \sin\theta_{u} \right)^{1.5} \right] L_{w} [math]
[math] \phi R_{n} = (0.75) \times 0.6 \times (70\ \text{ksi}) \times \frac{\sqrt{2}}{2} \times \min\left( 0.1875\ \text{in},\ \frac{3.7338}{16} \right) \times \left[ 1 + 0.5 \left( \sin 73.94^{\circ} \right)^{1.5} \right] \times (30.25\ \text{in}) = 185.84\ \text{kip} [math]
DCR = 137.36 kip / 185.84 kip = 0.739 < 1.0, in Ordnung
Dies ist die maßgebliche Prüfung. The same welds are good for 126.33 kip under shear alone, so the load angle adds about 47% to their strength. The demand grows faster, obwohl, von 38 kip to 137.36 kip, and the ratio rises from 0.301 zu 0.739. The tension and compression cases have the same resultant, so one weld check covers both.
Schritt 3: Balkensteg in Scherung (AISC 360-16 J4.2)
The beam web still carries only the 38 kip Querkraft, over its full depth:
[math] \phi R_{n} = \phi\, 0.6\, F_{yb}\, d_{bm}\, t_{wb} = (1) \times 0.6 \times (50\ \text{ksi}) \times (18\ \text{in})(0.355\ \text{in}) = 191.7\ \text{kip} [math]
DCR = 38 kip / 191.7 kip = 0.198 < 1.0, in Ordnung
Schritt 4: Säule unter axialer Spannung (AISC 360-16 J10.1, J10.2)
The axial tension pulls on the column flange along the line of the weld. AISC 360-16 J10 covers this as a concentrated force on the flange: lokales Biegen des Flansches (J10.1), where it applies, und Web-Local-Yield (J10.2). Lokale Verkrüppelung des Webs (J10.3) is for compressive forces only.
Lokales Biegen des Flansches
J10.1 does not require a flange local bending check when the length of loading measured across the member flange is less than 0.15 times the flange width:
[math] 0.15\, b_{f} = 0.15\, b_{fs} = 0.15 \times (14.5\ \text{in}) = 2.175\ \text{in} [math]
The load is delivered by the beam web, so the loaded length across the column flange is the web thickness, [mathin] t_{wb} = 0.355\ \text{in} [mathin]. That is less than 2.175 im, so flange local bending need not be checked.
Lokales Fließen des Stegs
The force spreads through the column flange into the web over the weld length plus [mathin] 5k [mathin] (Gl. J10-2):
[math] \phi R_{n} = \phi\, F_{ys}\, t_{ws} \left( 5 k_{des} + L_{wv} \right) = (1) \times (50\ \text{ksi}) \times (0.44\ \text{in}) \times \left( 5 \times 1.31\ \text{in} + 15.5\ \text{in} \right) = 485.1\ \text{kip} [math]
DCR = 132 kip / 485.1 kip = 0.272 < 1.0, in Ordnung
Schritt 5: Spalte unter der axialen Kompression (AISC 360-16 J10.2, J10.3)
In compression the beam pushes on the column flange, so web local crippling joins web local yielding. Lokale Verkrüppelung des Webs, Gl. J10-4, with the weld length as the bearing length:
[math] \phi R_{n,wlc} = \phi\, 0.8\, t_{ws}^{2} \left[ 1 + 3\left( \frac{L_{wv}}{d_{sup}} \right) \left( \frac{t_{ws}}{t_{fs}} \right)^{1.5} \right] \sqrt{\frac{E F_{ys} t_{fs}}{t_{ws}}}\, Q_{f} [math]
[math] \phi R_{n,wlc} = (0.75) \times 0.8 \times (0.44\ \text{in})^{2} \left[ 1 + 3\left( \frac{15.5}{14} \right) \left( \frac{0.44}{0.71} \right)^{1.5} \right] \sqrt{\frac{(29000\ \text{ksi})(50\ \text{ksi})(0.71\ \text{in})}{0.44\ \text{in}}} \times (1) = 465.59\ \text{kip} [math]
Web local yielding is the same as in tension, 485.1 kip. The lower of the two governs:
[math] \phi R_{n} = \min\left( 465.59\ \text{kip},\ 485.1\ \text{kip} \right) = 465.59\ \text{kip} [math]
DCR = 132 kip / 465.59 kip = 0.284 < 1.0, in Ordnung
Both column checks pass with room to spare, so this W14x90 needs no stiffeners or web doubler for these limit states.
Zusammenfassung der Schecks
| Design-Check | Nachfrage | Die SkyCiv Foundation umfasst das Design von isolierten Fundamenten, die den australischen Standards¹ entsprechen | DCR | Ergebnis |
|---|---|---|---|---|
| Mindestgröße der Kehlnaht | 0.1875 im | 0.1875 im | 1.000 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Welds under shear and axial force | 137.36 kip | 185.84 kip | 0.739 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Balkensteg in Scherung | 38 kip | 191.7 kip | 0.198 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Säule unter axialer Spannung | 132 kip | 485.1 kip | 0.272 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
| Säule unter axialer Kompression | 132 kip | 465.59 kip | 0.284 | Die Hälfte der Wandhöhe von der Unterseite der Basis für den Fall des |
Every check in this directly welded web shear and axial connection design passes. Das 1.000 Das Verhältnis ist die minimale Kehlnahtgröße, ARBEITSABLAUFPROZESS ENTWERFEN In Abbildung 3/16 in Schweißnaht trifft genau. Von den Festigkeitskontrollen, Die Schweißnähte regeln bei 0.739 unter dem 137.36 kip resultant, gegen 0.301 for the same welds under shear alone. The column checks for the axial force come next, with web local crippling in compression at 0.284.
Auto Design is available for the directly welded web connection with shear and axial load to a column flange. Es ändert die Entwurfsvariablen der Verbindung, bis jede Prüfung erfolgreich ist, und behält Ihre Mitglieder und Lasten wie eingegeben bei. Siehe die Autodesign Seite für die Einstellungen, mit denen es funktioniert.
Was ist zu ändern, wenn eine Prüfung fehlschlägt?
- Schweißfestigkeit: lengthen the welds, increase the weld size up to the base metal limit of the half web, oder verwenden Sie eine stärkere Elektrode. Past that limit a larger weld adds no strength.
- Column web local yielding or crippling: a longer weld spreads the force over more of the column web and raises both strengths. Otherwise use a column with a thicker web, or add stiffeners or a web doubler.
- Lokales Biegen des Flansches: with a directly welded web it only applies if the loaded length across the flange reaches 0.15 times the flange width.
- Minimum weld size or beam web shear: as for shear alone, meet the Table J2.4 minimum, oder verwenden Sie einen schwereren Balken.
Häufig gestellte Fragen
Why does the weld get stronger when the axial force is added?
The strength of a fillet weld depends on the direction of the load. Under pure shear the load runs along the weld, and the directional term of Eq. J2-5 ist 1. Mit 132 kip of axial force the resultant turns to 73.94 degrees from the weld axis, and the term rises toward its maximum of 1.5 for a load at 90 Grad. Here it lifts the weld strength from 126.33 kip to 185.84 kip.
Why is only one weld check reported for both tension and compression?
The axial force is 132 kipp so oder so, so the resultant on the welds is the same 137.36 kip at the same angle. The sign of the axial force matters for the column, which is why the support is checked separately for tension and compression.
Why is flange local bending not checked?
J10.1 only requires it when the force is spread across a meaningful width of the column flange. Here the force comes in through a 0.355 im Balkensteg, which is much less than 0.15 mal die 14.5 in der Flanschbreite, 2.175 im, so J10.1 does not require the check.
Why is web local crippling checked only in compression?
Web local crippling is the buckling of the column web under a compressive force pushed through the flange. A tensile force pulls the web straight, so J10.3 applies to compressive forces only, while web local yielding applies to both.
Wie würde sich dies für AISC ASD anstelle von LRFD ändern??
Die Grenzzustände und Nennfestigkeiten sind gleich. Mit AISC ASD vergleichen Sie die Kräfte auf Betriebsniveau mit der Nennfestigkeit dividiert durch einen Sicherheitsfaktor: 0.75 for the welds and for web local crippling becomes a safety factor of 2.00, und 1.00 for web shear yielding and web local yielding becomes 1.50.
Entwerfen Sie kostenlos eine direkt geschweißte Stegverbindung
Jede Zahl auf dieser Seite stammt aus einer Lösung. Pick the directly welded web configuration with shear and axial load, Betreten Sie Ihren Strahl, Unterstützung, weld and forces, und der kostenlose Rechner führt jede dieser Prüfungen in Ihrem Browser aus, ohne dass etwas installiert werden muss.
Das SkyCiv Connection Design-Modul ist die Verbindungsdesign-Software hinter diesem Beispiel. Sie erhalten den vollständigen Berechnungsbericht mit jeder Gleichung und Ihren darin enthaltenen Zahlen, wie die Schritte oben, plus jede Kapazität und DCR, für AISC 360-22 und AISC 360-16 (LRFD und ASD) und AS 4100:2020. Das Schweißrechner deckt Kehlnahtgruppen einzeln ab.
Quellen
- AISC 360-16, Spezifikation für Baustahlgebäude: J2.2b (Tabelle J2.4), J2.4 (Gl. J2-4, J2-5), J4.2 (Gl. J4-3), J10.1, J10.2 (Gl. J10-2), J10.3 (Gl. J10-4).
- AISC-Stahlkonstruktionshandbuch, 15th Edition: Teil 9 (Gl. 9-2), Teil 10 (effektive Schweißlänge).
- Entwurf von Stahlverbindungen mit AISC 360-16
- Autodesign im SkyCiv Connection Design
Harold Munalem
Produktmanager, Connection Design
10+ Jahre in der Stahlanschlussbemessung
LinkedIn